Тёмный

Soil compaction testing 

Bill Dorf
Подписаться 387
Просмотров 228 тыс.
50% 1

A typical field testing procedure to determine the load bearing capacity of t
he prepared ground....In this instance several feet of a clay loam fill compacted with a sheep's foot rolling vibrator.

Опубликовано:

 

18 июл 2014

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 60   
@Mr6Sinner
@Mr6Sinner 8 месяцев назад
Love how the video ends before the test is complete. Very useful.
@Antix619
@Antix619 2 года назад
5:27 - 5:33. I Love it. Exactly right. Theoretical and Correlations are all well and good for some applications, and gives us limited but some good information. An experienced field inspector is very valuable. Those blow counts mean nothing when you add more water to the equation, and have nothing to do with relative compaction.
@tackanderson4270
@tackanderson4270 3 года назад
Labor rate: 85/Hr. If you watch: 175/Hr. If you ask questions: 250/Hr.
@isabelaguillen5399
@isabelaguillen5399 2 года назад
why isnt he wearing earmuffs tack!
@TokenTombstone
@TokenTombstone Год назад
@@isabelaguillen5399 The real question is why isn't a woman doing that job.
@216inka
@216inka 4 года назад
Don't know why I watched this but right or wrong I never knew this & learned something.
@greatpharoh0303
@greatpharoh0303 5 лет назад
Thank you so much......Big Help!
@ghasanahmed6159
@ghasanahmed6159 9 месяцев назад
Very informative thanks doing mine soon
@jonathangreenawalt5724
@jonathangreenawalt5724 7 лет назад
This is a dynamic cone penetration test. Your not suppose to reverse bang the weight when moving the weight to the top when setting it to drop. That causes the cone to pop out of the hole and mess up the reading. When setting the cone up for the first test the cone has a flanged end which needs to be at ground level or the next increment level down and not driven down like he said which prematurely compacts the soil. That alters the test results.
@urbangangsta
@urbangangsta 7 лет назад
jonathan greenawalt yeah theyre amateurs, my boss would fire them but i would give them two 🖒🖒 because they probably get paid like doo doo
@Archuhi3
@Archuhi3 5 лет назад
I dont really know whats going on but i can tell hes not supposed to let it smack the top in between pounds lol, hes going against what hes trying to do.
@dpblogs1609
@dpblogs1609 5 лет назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-jubbj06bPXE.html
@terrapuraregenerative
@terrapuraregenerative Год назад
What other manual tests can be performed before construction?
@samuelteklebrhan6602
@samuelteklebrhan6602 6 лет назад
We can correlate the relative density (compaction) of the fill to the DCP value. However, the drop of the the hammering should be free fall. I don not think that was free fall.
@marcoflores8004
@marcoflores8004 4 года назад
looks like he was loosely holding it, but also lifting it up a lil too hard and topping it when he swung up so...
@uysoreaksmey7588
@uysoreaksmey7588 8 лет назад
thank
@vatoslocospinkcitrus
@vatoslocospinkcitrus 4 года назад
Poor compaction guy you guys annoyed the shit out of him with all your damm questions
@Totally_not_hated
@Totally_not_hated 2 года назад
I’m curious what the PSF for the dirt was
@sajjadali-hu5ld
@sajjadali-hu5ld 7 лет назад
which standard have this method any standard code?
@sam111880
@sam111880 5 лет назад
Seems a bit crude for penetrometer only usable in this form for residential not for skyscrappers you probably want a more continuous digital penetrometer capable of accurately giving you the kips or N /mm^2 values that you then can uses to know if you have enough compaction to build on.
@gergiskamal1591
@gergiskamal1591 8 лет назад
Hi i need some for determine the compaction
@Brandon-no3vc
@Brandon-no3vc Год назад
how do you know if watter table is 2 high to build a basement?
@jaipersaudsingh5913
@jaipersaudsingh5913 3 года назад
Hello i want to buy this whole equipment can you say where i can get it
@ByNEMeanZ08
@ByNEMeanZ08 2 месяца назад
That very different to a DCP we perform in Australia. I guess the technician here is augering compacted fill out a bit, to lower the resistance of the DCP so it doesnt give false readngs? Please correct me if im wrong.
@dereknoceda7807
@dereknoceda7807 6 лет назад
wow
@ravishrivas2069
@ravishrivas2069 9 лет назад
Thanku
@dpblogs1609
@dpblogs1609 5 лет назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-jubbj06bPXE.html
@sheetmetal3149
@sheetmetal3149 3 года назад
What if the ditch had about 50% clay Will the clay help compact or stop water flow reach lower
@Raph0ne
@Raph0ne 2 года назад
Based on what I currently study I can relate to two points.. 1. Having Clay that much won't help because of consistency (Harder to make it compact as the grains have around the same diameter) 2. As I know that Clay it's not really an Aquifer so it can prevent Water from draining deeper like you suggested BUT I think this will cause Liquidification in the soil above it - means that water will reduce the strength of Soil.. OMG it's hard to translate to English 😶
@grahamhanbury9427
@grahamhanbury9427 7 лет назад
okay i do this for a living and ive found this video is gonna educate people to do this incorrectly. no offense to the makers of this but ya the kid tried to do it and thats a valiant thing but ya this is how you get fired at a materials testing/ engineering firm
@abdallahsaad5677
@abdallahsaad5677 6 лет назад
A typical ECS technician I have no clue why he is doing a DCP for an embankment fill I think his project manager asked him to do that so he can have something to bill his client on.
@ivoryboxingnation3563
@ivoryboxingnation3563 4 года назад
He did not perform the test right by not doing a free flow blow, however if an embankment is to be compacted, the compaction has to be tested.
@ConsensusX
@ConsensusX 7 месяцев назад
It's all bullsht man. You can have widly different results by just testing 3 feet away. The whole point is to say soil testing was done and everyone goes about their day. I know project managers who would say "test at a different spot" when there is a failure.
@administrator1112
@administrator1112 8 лет назад
so, your description says just "typical field testing procedure" does it have a proper name ?
@theothertoolbox
@theothertoolbox 8 лет назад
+administrator1112 It is a bearing capacity test. This method describes the test used to evaluate the thickness and bearing capacity of the grade (and sub grade if using a hand boring device) using the Dynamic Cone Penetrometer. I use it to determine footing (column and continuous footings) bearing capacity.
@knowstress1
@knowstress1 5 лет назад
Why not use a nuke
@patriot4757
@patriot4757 Месяц назад
Need a proctor test for that
@The_Hardscape_Nerds
@The_Hardscape_Nerds Год назад
Where can this exact model penetrometer be purchased?
@peavyxs
@peavyxs Год назад
Durham geo slope indicator, this is the S-2000 model. No more pinched fingers
@The_Hardscape_Nerds
@The_Hardscape_Nerds Год назад
@@peavyxs Thank you! I reached out to them.
@sajjadali-hu5ld
@sajjadali-hu5ld 7 лет назад
hi guys i want to test soil compaction on road any body know about aashtoo or astm standard non-disturb way (field density test)NDT
@BracaPhoto
@BracaPhoto 9 лет назад
Where's your troxler dude!
@theothertoolbox
@theothertoolbox 8 лет назад
+branon mitchell That's for compaction...not bearing capacity. I could be wrong, though.
@BracaPhoto
@BracaPhoto 8 лет назад
You are correct... I would have cheated and used a hand held pentrometer and a probe rod... I'm lazy :)
@BracaPhoto
@BracaPhoto 8 лет назад
probably only need 2000 pcf anyway... it seems like fill though which is why I wondered why the he was doing load bearing test... I guess every county has their own requirements
@theothertoolbox
@theothertoolbox 8 лет назад
Yeah...and some of them are much worse than others. LOL
@theothertoolbox
@theothertoolbox 8 лет назад
branon mitchell Oh, I'm as lazy as they get. Small bit of water in a footing...call the CMT manager. Footing inspection CANCELLED. Trip charge.... Just kidding. Maybe. ;-)
@jamesrobertson4035
@jamesrobertson4035 3 года назад
So they said they pretty much know the results even before they do this test. Kind of like the 2020 U.S. Presidential election!
@gar949
@gar949 Год назад
🤣 Its funny because its true
@rahmaninsights
@rahmaninsights 5 лет назад
Can you help me to get a job
@MonoGmc
@MonoGmc 2 года назад
Go to a union hall. Why you asking on RU-vid
@KevanRice
@KevanRice 24 дня назад
I ran s drill rge eith spoon er
@patriot4757
@patriot4757 Месяц назад
That is not how to operate a DCP……☹️
@kappanistei
@kappanistei 4 года назад
This is so stupid!!
@rayhill1855
@rayhill1855 Год назад
The guy doing all the talking needs to shut up and listen to the experts.
Далее
Density Training - Video: In-Place Density
18:52
Просмотров 30 тыс.
КВН 2024 Высшая лига Четвертая 1/4
1:52:57
Proctor Compaction Test
10:35
Просмотров 328 тыс.
Standard Proctor Test
7:47
Просмотров 359 тыс.
Shop Build - Compacting the Ground
4:01
Просмотров 34 тыс.
Tools for Measuring Soil Compaction
5:49
Просмотров 48 тыс.
DCP Soil Testing - Monticello IA
1:01
Просмотров 58 тыс.
Soil Compaction Test
3:17
Просмотров 12 тыс.