Assalamualikum Sir my solax inverter is not generating power zero watts after the setting made by electrician And also plz guide how to check its extra generating units will reversed to wapda or not
Yes. But one problem if you are using without wapda and batteries then if you have10 panels or 12 panels. 70 percentage of panels should be attached to PV2 and 30 percent on PV1. BECAUSE INVERTER IS NOT USING PV1 WHEN THERE IS NO WAPDA OR BATTERIES. IT WILL JUST POWER ITSELF ON PV1
@@ArmaghanSaqib sir thank you for your video sir my solax invertor is showing me 370 volt but not taking electricity from solar panel taking it from KE What is the reason
Is inverter ke sath jab wapda ko on karte hain to metre Mein reverse light on ho jaati Hai aur Agar inverter ko bypass kar do to fir on Nahin Hoti aap iska koi HAL bata sakte hain
Dear Sir, need your kind advice please. I have recently installed a 6kw solar system through a vendor in Peshawar. We have installed the same Solax 6kw Hybrid Inverter with 12 N-Type A grade 585w solar panels (which makes it a 7kw). We have not installed a battery yet because there is only 3 hours of loadshedding in my area during the day time (and I ran out of budget as well). It shall be noted that I have only two 1.5 ton Full DC inverter ACs, a normal size fridge, 3 ceiling fans (60w), and some light. The average load of the house is around ~3.5kw. Suppose at 10:56am when the solar system is producing power at peak level, it would be supporting the entire load of the house and even exporting some to the Green Meter as well (which is yet to be installed). Now the problem is that as the grid goes off at 11am (loadshedding), the inverter would trip and would show DCBUS_SW_UVP error on it. It then restarts and immediately trips again and continues unless I manually go and switch off the both ACs and the Fridge. I contacted the vendor many times and they visited many times but could not fix it. Today they shared that it is the nano-second torque of the ACs, and probably the Fridge, that trips the inverter and does not let it the PV's increasing flow to the inverter. They recommended that you should install (min 48v) battery/batteries to help with the torque to have the system running and pass through without tripping. Can you please help? What should I do?
Fahad Brother did you find the solution for the problem you have mentioned? I need your advise as I am also from Peshawar and going to install same as yours solar system with 10 Canadian Top-Con Solar panels and Solax 6KW hybrid inverter.
I am also from Peshawar… looking to install the same inverter with 16 Inverex panels of 575 watt.. but i am so confused regarding inverter as will this inverter work without battery and by cutting off wapda or not..?
If i take a connection for AC load without batteries from inverter, so it will run the ACs load in day time, what if at night will our ACs will work on single source wapda from inverter ? ......did you check it ?
Yes and if you have panels maximum panel should be series in pv 2 because it take pv1 only to start inverter if you dont have wapda. If wapda is there than it is using both string if no wapda it will use only string 2 for load and string 1 for inverter power. For example if you have 10 panels 7 panels should be on pv2 and pv1 3 panels
Maximum string should be on pv2 and pv1 minimum string. For example if you have 12 panels 8 panels should be on pv2 and 4 panels on pv1. Because without wapda pv1 is not using only it will power inverter. If you have 11 panels. 8 panels on pv2 and 3 panels on pv1
Assalaam o alaikum. We have installed this but when wapda turns on solar power completely stops and it shows power is only drawn from wapda. When wpada turns off it starts drawing power from solar.
580 watts should work. I am using Trina 595 watt double glass panels without any problem. I have run a/c with wapda but should run without wapda too. Will test and share results. Also I ran a non-inverter 2 ton a/c and it ran fine.
Assalam o alaikum. I recently have installed Solax 6kva inverter, I tried to install the software from the usb but nothing happened. Do you need to do something to detect it?. Secondly in my Fronus Solax inverter the WiFi does not have the antenna, has it been removed, box was apparently sealed packed.
You have to put Software Usb first than turn on the inverter, system will automatically detect the Usb and for Wifi device it doesn't come with antenna nowadays you can directly connect them to your router..👍
@@GHOSTBOSS212 us se kam he lekin yeh ek ajeeb noise he iska fan neeche se hawa le kr ooper se nikaalta he jis se ajeeb awaaz nikalti jo km to hoti he lekin sar dard karti
Solax is an international brand being used in many countries around the world where as Inverex is a local brand. So far in my experience it is quite robust. And price difference is also really big; around 100k cheaper than nitrox.
Battery zarori nahi hai. But grid should be present for stable operation. It can run on only solar but then load should be about half than the PV output at that time.
Yes but 10 plates should be connected to pv2 and 4 to pv1. Then it will work without wapda and batteries. If you are using battery then 7 on pv1 and 7 on ov2
@@KashifKhan-1760 hona chaye agher nahi ho Raha to software upgrade karwain company ki website site pa ja k complain karain wo online hi upgrade karwain gain ap ki wifi connect honi chahye net k sath
I don't understand why you bought a hybrid inverter. If I'm not mistaken there are also on-grid inverters that can operate off-grid (in island mode); I know for sure that microinverters can do this. On-grid inverters are cheaper than hybrid inverters and more efficient, because the hybrid inverter will first use an MPPT to bring the voltage down to a battery charge range and then the inverter has to modify it up again to grid voltage. This causes additional losses, compared to an on-grid inverter that can transform the voltage from panel DC voltage straight to AC. With microinverters you'd also have AC available when the grid goes down during the day.
Bhai agar on grid inverter letay to agar din mien wapda jati to in ka solar setup or 4 ac jo chalany hien inhon ne wo band ho jaty chahaye kitni b bahir dhoop nikli hoti. Isi liye hybrid liya hai bhai ne ta k wapda ho ya na ho din mien solar chalta rhay ac chaltay rhien din mien wapda ho ya na ho. Jab k on grid inverter wapda k baghair nahi kaam krta din mien b usay wapda chaiye hoti hai. Light janey pr wo din mien b band ho jata hai.
@@vitalfarms7534 I think you can buy separate electronic systems to disconnect from the grid automatically when the grid goes down. A hybrid inverter has such a system integrated.
I have to attach batteries after few months so that is why I have purchased hybrid one. In addition, it works without grid too. I could not find any on-grid inverter which could work in what you call 'island' mode. If you know one, let me know. There are solutions with switches and relays to activate an additional hybrid inverter when grid is off but why complicate life?
@@ArmaghanSaqib Yes, if you add a battery later then this is a very good solution. Most micro inverters can operate in island mode. I've seen an on-grid inverter that can operate in island mode, but they are quite rare.
main kal yeh install karvawa hia . solar aur bettry per theek chal raha hia . lekan jab wapda on karte hian yeh bettry or load ko wapis wapda per export kar raha hia . humne export bhi off ki hoi hia . installer ko bhi samaj nhi aa rahi kindly help.
Have you followed these 3 steps? (1) CT installation on wapda live (2) Enable 'No export' setting in inverter (3) Enable CT setting in inverter from None.
Bhai bahut say installer's ko inverters ki settings ka pata hi nahe vo bus wiring waghaira kr letay hain us kay baad bhagnay ki krtay hain, yeh to Allah ka shukar hay hum khud hi inverter ki setting main ja kr aur user manual parh kr kuch na kuch setting kr letay hain otherwise installer to Allah maaf karay ziyada tar non professional hain.
محترم اسلام علیکم اگر سولیکس انورٹر کو بغیر بیٹریوں کے سولر پر چلائیں تو واپڈا کی لوڈشیڈنگ ہو جائے تو کیا اے سی سولر پر چلتا رہے گا یا بند ہو جائے گا. مہربانی فرما کر میرے سوال کا جواب دیجئے.
@@saadhasan6612 Agar apka ke paas panel hai to apkp chahiye ke 70 percent panel pv2 par lagai maximum 550 volt tak lagasakte hain. 30 percent pv1 par kyonke inverter. Pv1 apne power keliye use karta hai or Pv2 load keliye. Agar battery ya wapda ho to phir dono string load keliye use karta hai
Fan is in heat sink and outside main body. It starts running when inverter heats up; usually when you put lot of load or in very warm weather. Otherwise it stays silent. I have Inverex 3.2 and Solax in same room. I can hear the sound of Inverex but Solax stays silent mostly.
Inverex and Solarmax are also good but 100k expensive. I have found Solax much better though as it allows12 kw torque load for upto 10 seconds. Which means all your old A/Cs, fridge and other appliances can work.
Assalam o Alaikum hru sir main Solax power 6kw use kar raha hun 1 week pahlay instal karwaya hai aj 1st tme light gai hai to inverter solar par nai chala har cheez 00 ho gai main nai battrey nai lagai ab kia kiya k direct solar par load uthai jab light jai to @@muhammadafzaal8670
@@AnayaTawanbattery 🔋 lagai apny isky sth? If battery 🔋 fit hai Apke system Mai phir work kryga agar battery 🔋 NAHI hai to KE off Hogi to apka solar system BHI off hojay ga. Ek support lazmi chahiyae Inverter ko working on rakhny KY liyae.
اچھا انکل جی وہ اپ سے ایک بات پوچھنی ہے کہ ہم نے یہاں پر ایک یہ انونٹر لگایا ہے نہ تو اس کی کچھ پرابلم ا رہی ہے کہ وہ ہم نے نیٹ میٹرنگ نہیں کرائی ہوئی تو تو جو ہمارا واپٹا والا میٹر ہے نہ سنگل والا وہ اس کی فالٹ والی لائٹ بھی ان ہو جاتی ہے اور وہ وہ جو اس کے اندر میٹر کے اندر جو لائٹ ہوتی ہے نا وہ فلیشنگ والی وہ بہت جلدی جلدی کر رہی ہے وہ بہت جلدی ان اف ہو رہی ہے تو اس کا کیا پرابلم ہو سکتا ہے ہم نے اس کے ساتھ بیٹریاں نہیں لگائی ہے تو رہنمائی فرما دیں بہت مہربانی ہوگی
@@ArmaghanSaqib Sir, my maximum PV input was 2200 watt and 600 watt was shared from grid. Maybe that's the reason for the fan on. The ventilation condition is almost the same at my site
I am in Lahore. Please search Internet for suppliers. Hopefully you should get it for 270K. Its company/control price is 260K but shops are charging extra.
@@talalakram7 It is better to wait couple of weeks as inverter shipments have started coming in now. Price will automatically go down at dealers too when they will face competition from other brands.
@@ArmaghanSaqib yes of course. I purchased this inverter 2 days before eid. At that time, i approached to SolaxPower Head office by some reasonable source. They clearly informed they are out of stock and restock may take 2 months or more