Time Stamps For Video:
Grounding 0:42
Battery Communication 2:55
Inverter Paralleling 6:42
Inverter Programming 9:19
Tools purchased for Our Solar Install:
Cable Stripping Knife: amzn.to/3pkWlOO
Klein Wire Stripper: amzn.to/3Ib3tWD
Klein Crimping Tool: amzn.to/3E8gk9P
Large Gauge Hammer Crimper: amzn.to/3ro7rVZ
Large Gauge Wire Cutter: amzn.to/3lqUiI2
Ferrule Crimping Tool with Ferrules: amzn.to/32RgJQj
Copper Lugs: amzn.to/3EfLRGK
1.5" Wrench: amzn.to/3o9gh8c
24" Breaker Bar: amzn.to/3rrMQAk
1.5" Socket: amzn.to/2ZIqnn7
Solar and electrical equipment used in this video:
Growatt SPF 5000 ES Off Grid Inverter (www.signatures...)
PV Disconnect Box (www.signatures... )
SolarEdge Midpoint Transformer (www.signatures... )
12 position electrical sub panel: amzn.to/3DVKZpZ
8 gauge THHN wire: amzn.to/3oUDpaI
6 gauge 6/3 romex wire: amzn.to/3DUMzZi
30-40 amp double pole breakers: amzn.to/3DWV2ej
Safety switch amzn.to/3m5HHdG
conduit as needed
mounting hardware as needed
Hardie backer board
Emergency Items We Own:
Butane Cooking Burner: amzn.to/3rbVmAj
Primus Camp Stove: amzn.to/3sLqvLc
Isobutane: amzn.to/3uLvJsr
Mr. Heater: amzn.to/3bUCLlV
Sunglife Survival Radio: amzn.to/3qbKD7L
Solar Cell Phone Charger: amzn.to/3q8Nezn
Crosscut Saw: amzn.to/3bW3eQc
Scythe/Snath: amzn.to/3bdCTOx amzn.to/2PvDVNr
Items Used To Start Our Seeds:
Jiffy Peat Pods: amzn.to/3rtqaMA
Metal Racks: amzn.to/3oYsU2T
Barrina Grow Lights: amzn.to/3tDW0IA
1020 Grow Trays: amzn.to/2LuMF4v
Heat Mats: amzn.to/36W6lpv
Rack Cover: amzn.to/3cRX2KZ
Humidity Domes: amzn.to/3rzED9S
Pot Labels: amzn.to/36TDm5K
2" Seed Starting Pots: amzn.to/36OZK07
Tools And Products We Own And Recommend For Your Homestead:
Dewalt impact driver: amzn.to/2ptNXBY
Granite Ware water bath canner: amzn.to/2CQquOn
Bear Grease waterproofing compound: amzn.to/2CNDBzO
Greenhouse film: amzn.to/2poM2yn
DB Smith pump sprayer: amzn.to/2Qr9o1m
Marbles small camp axe: amzn.to/2KsbuKT
Cold pressed orange oil: amzn.to/2KvaaXo
Sea-90 organic mineral fertilizer: amzn.to/2rK9cA2
Pure neem oil: amzn.to/33WTmR4
Products We Own And Recommend For Your Garden:
Flame Weeding Torch: amzn.to/2Zf2Is3
Worm Castings: amzn.to/2mboTh8
Neem Oil: amzn.to/2ZgBDka
Rock Phosphate: amzn.to/2TJyE2L
Chapin Garden Sprayer: amzn.to/2KHld06
Garden Ties: amzn.to/2HgYk1H
Professional Weed Barrier: amzn.to/2Hhm7hM
Greenhouse Film: amzn.to/2KG3Ahj
Thanks for stopping by and don't forget to come see us on:
Our Site: countrylivinge...
Facebook: / countrylivingexperience
Pinterest: / pins
Instagram: / countrylivingexperience

Опубликовано:

 

28 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 320   
@CountryLivingExperience
@CountryLivingExperience 2 года назад
ALL OF OUR SOLAR EQUIPMENT...CLICK HERE: www.signaturesolar.com/?ref=countrylivingexperience
@ruwankumara6226
@ruwankumara6226 Год назад
Hi how we keep fan Stand by mode
@ruwankumara6226
@ruwankumara6226 Год назад
It's run all wase
@RoarPowerNZ-tt6ud
@RoarPowerNZ-tt6ud Месяц назад
Great video, really appreciated. Just a correction: at 6:19, "36" is not a protocol number, its a setting number. To run through your process ... You are at setting #5 (the battery type). You press enter, and the value of that setting is set to US2 (which you correctly say is the User #2 setting, used for dumb lithium batteries, where the battery is controlled by voltage only, not by comms). You press the down arrow and change the setting to LI (Lithium). When you press enter again, you are not looking at a setting of "protocol 36", you are have been jumped to SETTING #36, which is "Protocol" (the left side shows a cryptic "Ptcl" which means PROTOCOL). Here, you are setting the protocol number, in your case to "01". Protocol numbers (for Growatt and a number of similar all-in-ones) 01, 02, etc up to 49 are variations of the RS485 protocols. This protocol is a request-response protocol (ie the Growatt asks for data, and the battery answers) Protocols 51, 52, etc up to 99, are variations of the CAN protocol. The CAN protocol is a broadcast protocol, ie the Growatt just listens, and the battery repeatedly broadcasts its requested charge voltage, SOC, requested current, etc etc, and doesn't care if nobody or everybody is listening. For other readers: If you BMS is a fairly typical BMS of the current era, its likely to have a CAN port, an RS485 port, then an RS232 port (6pin), then a pair of RS485 ports. If so, you can use the BMS port on the Growatt, the CAN port on the battery, and protocol 51 or 52. If your battery only has RS485, or if you want to use RS485, or if your battery/BMS is more reliable over RS485, you can use the BMS port on the Growatt, the RS485 port on the battery, and protocol 01 or 02. One other correction - you say that older Growatt SPF5000ES used the RS485 port. This is correct, but "which port on the Growatt will work" is comms-board and firmware dependent. Older versions of the comms board and firmware had a limitation where every parallel inverter had to have a cable, and a MODBUS hub did the job of making sure all units saw the same data. Newer comms and firmware, as you correctly mention, share that data over the grey serial cable, so only the master Growatt needs a cable to the battery. The red/black is the cable that allows the inverters to sync their (output) sine wave. It might be more correct to call them frequency sync cables, rather than communication cables. An important note is that you can't really stuff up the grey cables, as they are gendered. You can stuff up the red/black cables, but I don't know the result of this. At 8:58 you enter setting 23 (in standby mode) and change to PAL . This is correct, but you are not correct that you "can just esc out" - your setting was not saved, and at 9:01 you can see that the settings have changed back to SIG (inverter in "Single Inverter" mode). This probably worked out OK for you, because (at least with modern firmwares) when the units power up again, and see the grey serial cable is connected, they will know they are in parallel mode and default to PAL. With all settings, the setting is not saved (and also not checked for compatibility with other settings) until you press enter. Note: If you setting is NOT accepted (lets say the value you set is outside the acceptable range, or conflicts), at the point you press ENTER, the setting will change back. Another note: If the setting is READ ONLY (ie setting #2 for a comms battery), when you press ENTER to jump into the value and change it, you will instead end up on the next setting down, in this case setting #3. This is how you know the setting is read only. Also, with newer firmwares, some settings in the manual that say "This setting is only available when the inverter is in standby mode" are actually settable in both modes. One example is the output voltage; we regularly change the output voltage (setting 08) without turning off the inverter switch - you will get a ~2 sec outage where the inverter stops, then restarts, but you do not need to turn off the switch. DIS is Disabled, not disconnected, but same same really. "Setting #11 is only for lead acid batteries" - No, setting 11 is not relevant in your setup, but not because its for lead, its because you don't have a generator or grid backup. Setting #11 is how you control how fast the batteries charge from UTI (utility, aka grid or gen). This enables you to limit how much your Growatt pulls from the generator for recharging (vs running the house). Setting #12, you are mostly correct, this controls when the grid or generator kicks in, but it *wont* prevent your battery discharging past X percent - the Growatt is still drawing 80w, and the house is still drawing power. Once you get to setting #12's percentage, the dry contact will change over (potentially starting a gen), and if power is then available on the input terminals, it will start to be used. *Now* your SOC will rise, but only if gen/grid continues to be present. Its moot, but important: at this point, the battery is STILL being used to run the overhead of the Growatt (~80w per inverter), so if (as in your case) you have no grid and no generator, even if you disconnect the house, you will be slowly dropping in SOC. This might seem like nitpicking, but its important; if you hit #12 at say 6pm in winter, with no grid/gen and a disconnected house, you might need to handle 160w of draw (2 growatts) for another 16 hours until the sun hits your panels again. You can prove this by setting #11 to zero amps, turn off your solar breaker (simulating night) and see that when the battery gets down to #12's set point, the battery is still being drawn down. Setting #13 is nothing like you describe. This setting is where the generator will stop (the dry contact will be switched back to "normal"), or the grid will stop being used. If you reach as low as setting #21 (probably the setting you were thinking of), the inverter will stop powering the house, and grid/gen will power the house (in bypass mode) and optionally recharge (at the rate of setting #11). If grid/gen is not available, the inverter will still power the house (and the batteries will therefore continue to drop). Once you get some incoming power (solar or grid or gen), its something like 5% (seems to be firmware dependent) above setting #21 that power comes back on (ie the inverter starts inverting again). I don't understand why you say charging the batteries from grid is not good for them. We charge from grid all the time, also from generator (which is almost the same except the power is not as clean). The SPF5000ES has no dedicated grid-to-battery charger - the grid/gen powers the DC bus, as does the solar, and this bus can handle from 150v to 450v, and DCDC this power down to Vbatt (the specific voltage depends on the battery type, SOC, charge algorithm, and settings 19/20). There is no problem running the system without PV - this occurs all night, and any time the PV disconnectors are off. We also tell customers not to run without PV but only because it could be weeks before they finish the PV part of the install, and recovering a battery from protection mode (when the voltage is so low the BMS disconnects the cells from the terminals to protect itself) is a pain, so i expect that SS are also saying that to avoid support calls from people leaving the SPF5000ES dragging 80w all day and night, and eventually causing a low battery issue. Great video, its awesome to hear good quality audio, steady and in focus video, and clearly enunciated words, well done.
@And1Mell
@And1Mell 2 года назад
I have enjoyed all of the videos I have seen from you so far, great info and well articulated. We, that's my wife, young adult son and I, are about to embark on a similar journey in central Mexico. We are about to take possession of a little 38 acre ranch at an altitude of 8000 feet. Out of the 38 acres, 10 acres is a pond. The pond is 25 acres in total but our geographic boundaries include 10 acres and our neighbors owns the rest. The property is on a main road and has access to electricity, but it was never run in. Instead of going through that process, we have decided to go with an off grid solar system, which is similar in installation cost, but offers us complete independence. I have looked at many different solar systems, but the Growatt All In One system appeals to me the most, as it is cost effectively distributed here in Mexico. I also like the MPP Solar units, but they would have to come from Taiwan. I really like how you can string the units together, as it makes it easy to increase the system output size and if one unit breaks down you can at least function on reduced capacity. I'm looking at 2 or maybe 3x 3000 watt units, with 8000 watts solar and 20000 watts battery back up. Not requiring heating and air conditioning, makes life easy in regards to energy requirements.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Very cool. Blessings on your adventure. Not needing heating or air conditioning will be a huge energy savings.
@lamarkanagy6741
@lamarkanagy6741 2 года назад
My understanding of the whole grounding/bonding discussion is that an electrical system will work okay in most cases with various configurations of grounding/bonding, but where it becomes an issue is IF there is either a lightning strike or a fault in the system caused by a short in a load. In the case of a lightning strike the ground rods are the primary resolution. However, if I’m correct in interpreting NEC guidelines, there should only be one earth grounding point (rod or rod sets) for the same building even it has multiple sub panels due to the fact that voltage potentials could be different with a rod on each panel which could create an arc across something in the building. Regarding a system fault from a load short, since the voltage always looks for way back to its source, the neutral plays a big part in clearing a fault via the breaker in the panel. If sub panels are bonded (neutral to earth ground) where they should not be, the voltage doesn’t have a clear path back to its source to clear the fault. Again, if I understand correctly, that means the panel that combines the AC from the inverters as well as the mid-point transformer that creates the neutral for the 120v loads should be the point at which the neutral bus is bonded to earth ground on an off-grid system.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
I appreciate your insight. There are so many varied interpretations and opinions on this. i am part of the diy solar forum and most on there cannot agree. There are professional electricians, electrical engineers, solar companies, etc on that forum.
@MichaelBrown-xb6pp
@MichaelBrown-xb6pp 8 месяцев назад
Mike Holt has excellent informational videos. He has definitely convinced me that there absolutely should only be 1 earth ground point in a building or structure. You do not want a nearby lightning strike to ride in at one point through your house and equipment and out the other point. Very Bad. Power always looks to get back to source, not the ground. Everything inside should be bonded together, leave at 1 point, and multiple rods outside should be bonded together. Good luck and stay safe. @@CountryLivingExperience
@GrowingUpGoudie
@GrowingUpGoudie 2 года назад
Down Arrow and Enter at the same time will remove the beep temporary so you don't have to listen to the beep when you are adjusting settings.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Thank you for the tip.
@johncollins6639
@johncollins6639 2 года назад
I bought a two LFP system from system solar with case with out doors and top. I am trying to build a moveable system. I will send pictures. I put the GroWatt system on one side. I plan to charge from the house ( solar ) to the two batteries. And use the GroWatt to go from DC to AC. I Plan to use extension cords to power the items in the home.
@chriszbodula1894
@chriszbodula1894 2 года назад
In my area they require 2 ground rods. The second needs to be at least 6 apart from the first
@CountryLivingExperience
@CountryLivingExperience 2 года назад
I understand that is for the power grid.
@Masteradamant
@Masteradamant 2 года назад
Top quality gear there sir; I’m frugal and agree a Grow-watt is worth it
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Very cool. Thank you!
@DeadUgly1
@DeadUgly1 14 дней назад
Earthing is only recommended if you are attached to the grid. Earthing has been done for stability of the voltage, (Look up MEN,Multiple Earthing Neutral) of the Power Stations. You are less likely to be electrocuted if you are not earthed.
@cannfamtube
@cannfamtube 2 года назад
Thank You for explaining clearly . However, I have a buddy who has worked for the utilities for 40 years . He tells me you should never ground a battery . The ground will draw from the battery quickly ! If you do try it, please check your levels every few hours . GOOD LUCK
@echopapa819
@echopapa819 2 года назад
LiFePO4 battery systems function very differently than Lead Acid batteries. The electronics in the battery case need to be grounded.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Thank you.
@timbensing1075
@timbensing1075 2 года назад
Don't, ground the battery positive or negative. Do, ground the metal case that is surrounding the battery.
@timbensing1075
@timbensing1075 2 года назад
Also, the mounting screws between the battery case and the rack are not rated for grounding. You need to make the ground connection separately from the mounting.
@benjones8977
@benjones8977 2 года назад
What I heard was to ground your bus bars instead. All your equipment goes through your bus bars and you can ground everything from there. You only ground the negative side.
@cowboymcq6711
@cowboymcq6711 Год назад
Great video I’m replacing my EG4 6kw with these units Thanks for the amazing setup help dude 👍🏼👍🏼👍🏼👍🏼❕❕❕
@CountryLivingExperience
@CountryLivingExperience Год назад
You're welcome. Why replace the EG4?
@cowboymcq6711
@cowboymcq6711 Год назад
@@CountryLivingExperience I’ve had nothing but bad luck with the EG4 6000’s error and fault codes non stop 😢. Been dealing with a customer service for three months now trying to figure everything out
@CountryLivingExperience
@CountryLivingExperience Год назад
@@cowboymcq6711 Yikes. That's not good.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
I just got off the phone with Sig Solar as well. The are going to provide schematics for proper grounding, are working on them as fast as possible, and will post them soon. We run the 5000es as a completely off-grid system and the model we have has the bonding screw removed so I am not that worried. Additionally, the Growatt transformer they are selling now is different than the SolarEdge. They will provide further info on this soon as well.
@taulli1
@taulli1 2 года назад
Great videos, I agree with your sentiments... Can you provide a link to the grounding update from SS please? These videos are super helpful. Thanks!
@CountryLivingExperience
@CountryLivingExperience 2 года назад
@@taulli1 They have told me that the method I showed in the video is correct. I have had other electricians contact me to still say it is wrong. I am leaving it as I showed it in the video but will continue to research it. There is no link from them at this time.
@taulli1
@taulli1 2 года назад
@@CountryLivingExperience Thank you for the quick reply! Are you up and running yet? Do you think the various methods (opinions?) of grounding are esoteric, have pros/cons, or do you think there is a day to day advantage, or is this a catastrophe avoidance issue? This has been a troubling setback.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
@@taulli1 Don't be troubled, it will work out. I have found that varying opinions come from varying experiences. I trust the solar company. I am still doing my research as well. I am not an electrician. My electrician said it looked fine and some others said it didn't. My system operates flawlessly.
@aungthuta5022
@aungthuta5022 2 года назад
Thz for sharing step by step programing
@CountryLivingExperience
@CountryLivingExperience 2 года назад
You’re welcome
@waynewilliamson4212
@waynewilliamson4212 2 года назад
another cool video...disappointed to see all the cables between the inverters. seems like rj45(ethernet) could have handled all of that. kind of silly to have the rs232 cables as well as the twisted pair set. They probably could have just connected them with usb. Its not like there would be gigbits of info flowing there.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Thank you. Once I get everything running smoothly like I want, I will clean up the cabling.
@johnschnee3934
@johnschnee3934 2 года назад
We are Saved by Grace Through FAITH NOT WORKS. Salvation is a free gift from GOD given to those all who will believe LORD JESUS CHRIST DIED AS A SALVATION LAMB for our sins by the BLOOD OF LORD JESUS CHRIST HIS BLOOD CLEANSES Our SINS
@johncollins4888
@johncollins4888 2 года назад
Where I live in Florida I can get 15 volt differential between grounds!
@abusam1
@abusam1 8 месяцев назад
great informative video but opens up a box of questions😁. *1* on t=4:27 how would I know I have the older or the newer version (visually or screen info)? *2* on t=10:10 if the setting was SBU or SUB (if the inverter was connected to utility), this means the solar will provide power but for some reason solar power was not enough (excessive load, not enough panels), will it compensate from the next selection or will it switch 100% to the next selection? *3* on t=13:12 why charging the battery is better-off to be charged by solar if I have utility (clean and steady) connected? *4* on t=15:30 why it is important that I have battery before I power the system, is that because I may not be generating enough voltage (nominal operating voltage) from solar and this will result in error (auto-restart)? I was thinking to go battery-less and have only solar and utility🤔. fyi: I have 230v/50hz utility
@CountryLivingExperience
@CountryLivingExperience 8 месяцев назад
Thanks. 1. There is no way to tell. You will have to try both ports. 2. It will compensate and share power sources with the loads. 3. For this brand, solar input is recommended for best results and battery stability. 4. I was advised of this issue by the distributor. I am not sure of the technical details. This specific Growatt inverter was modified by the manufacturer per the distributors technical specifications for the American grid. If you buy these outside of North America, the internal configuration of the Growatt 5000es will be different. These are technically Growatt 5000es-US models.
@jakejoeep23
@jakejoeep23 Год назад
Thank you so much. Your videos are so helpful. You say to not charge from the grid. But SS has said I can do that and it will work fine. Why do you say it is not good for the health of the system? What happens if your batteries get too low and you don't have enough power for your home?
@CountryLivingExperience
@CountryLivingExperience Год назад
You're welcome. It will wear the inverters out quicker. If I don't have enough battery then I don't have power. I will have to wait until the sun recharges. My system is technically off-grid anyway.
@hedibenoug6981
@hedibenoug6981 6 месяцев назад
BONJOUR MERCI POUR CETTE VIDÉO
@CountryLivingExperience
@CountryLivingExperience 6 месяцев назад
je vous en prie
@ruwankumara6226
@ruwankumara6226 Год назад
It's working all wase
@Wrensspeedshop
@Wrensspeedshop 10 месяцев назад
Hey there again. I w finally got my Growatt Grid Tie setup in place and running great. It’s now time to start looking at batteries and was curious as to how much life each day you get out of your batteries? I know the larger draw you put in them the quicker they’ll run down, I’m just trying to get a general idea how they do. I’ll most likely be buying one at a time, slowly adding more capacity as time goes on. As usual great video(s) and very informative.
@CountryLivingExperience
@CountryLivingExperience 10 месяцев назад
Glad you got your system up. It is hard to say. There are so many variables. How long are you running each load and how much sun do you have that particular day. It is honestly hard to nail down. I keep adding batteries as well.
@rayebel4430
@rayebel4430 2 года назад
Be nice to see a dc disconnect wiring video
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Noted!
@hendersonsobers396
@hendersonsobers396 2 года назад
Great video. Thanks for taking the time to make this. Learnt alot.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
You’re welcome
@Bylliedekid
@Bylliedekid 2 года назад
Excellent explanation my friend. What about the reliability of this model? My project is exactly as yours. I’m gonna buy 2 inverters, 12 550w solar modules and 30Kw of lithium batteries.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
They are very reliable but with any electronics something can happen. I will get another as a backup just in case. Signature Solar has been great to work with too.
@stamperbrian
@stamperbrian 2 года назад
This grounding thing is killing me in my setup. I like you have watched so many videos, researched so many documents..tried to understand NEC code, etc. On the 5000ES the AC in and AC grounds are connected and they are also connected to the case (verified with ohm meter). In my setup the AC in from grid comes off my main panel which is obviously grounded (bonded neutral). If I were to connect the AC in ground to my utility panel. Then connect the AC out ground to my Feeder panel for solar. And lastly the ground on the inverter to the Feeder panel ground. In my mind, this leaves one path to ground. All the breakers, the Transformer up through the inverter, back to the main panel ground and that just doesn't seem "right" to me. My thought is. Run a ground only from my utility panel ground to my feeder panel ground. Then run all grounds as part of this system (AC IN, AC OUT, Inverter) to the feeder panel ground. In this case every ground goes direct and doesn't flow through the inverter. I don't know if its right....but it feels right with having a single ground and a most direct path to it. I could see having a separate ground on the DC side that would ground the batteries and solar panels themselves but couldn't argue why you wouldn't just use the same ground.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
I hear you. I have gone around and around with the solar company and electricians. Not all of them agree with each other. Since I am an off-grid system I am not sure I can respond to your thoughts directly. There is a diagram from Sig Solar on the DIY Solar Power Forum. They did some testing, etc for it and their engineer came up drew it. Not everyone on the forum even agrees with it. Here it is for reference diysolarforum.com/threads/safe-grid-use-of-the-5000es-and-transformer.34121/page-2 P.S. I did a drawing of my exact system and sent it to their engineer. He said it looked fine. P.S.S. I am still a bit unsure, however.
@stamperbrian
@stamperbrian 2 года назад
@@CountryLivingExperience HAHA with all this its funny the one thing confusing everyone is the ground. However, looking at that diagram in the post it appears to be exactly what I suggested The ground of the Utility Panel, Growatt's, Transformer, and panels is all tied in one. This is very helpful! I appreciate it and the reply!!
@MrGintas11
@MrGintas11 Год назад
Labas. Geras video. Ar galėtumėt paaiskinti,kas netaip mano Growatt? Išanksto dėkoju.
@PaulNelsonphotography
@PaulNelsonphotography 2 года назад
I'm a supervisor electrician here in Oregon and that ground rod is not going to do crap other than cause some earthworms to come up if there's a fault.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
So you are saying my electrician and the solar company are wrong. Separately derived system? They instead of throwing stones, give a solution.
@PaulNelsonphotography
@PaulNelsonphotography 2 года назад
@@CountryLivingExperience you have to tie it back into the main EGC system
@CountryLivingExperience
@CountryLivingExperience 2 года назад
@@PaulNelsonphotography It is an off grid system. The main power is cut via an interlock kit. It is a separate power generation station like a generator. Factoring those things in with the addition of my electrician and the solar company saying the opposite, do you still say this is wrong and why?
@PaulNelsonphotography
@PaulNelsonphotography 2 года назад
@@CountryLivingExperience Even if you take off the utility you have to establish a main EGC. You Can have issues with the electronics with different potentials. I would need to see the system. You need ( 250.25 article 705 ) 1 single electrical grounding electrode system. 250.4 and 250.6
@PaulNelsonphotography
@PaulNelsonphotography 2 года назад
@@CountryLivingExperience are the Ungrounded conductors the only ones that are cut?
@marknktown2642
@marknktown2642 2 года назад
What size lugs for the inverter and what battery cable size is that? tried to find when you hooked up your batteries but missed it somehow. Thanks for your videos. You explain things well.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Glad we could help. 2awg batt cable and 5/16" lugs. I just got the battery cable from the auto parts store.
@mnl8965
@mnl8965 2 года назад
Hi. I have one unit of SPF5000ES working good with pylontech Li batteries by can BMS port for 3 months. Now I just buy the second unit for paralleling. Both inverters will work with the same 14kw Li bateries. Do I have to buy the hub rs485/can growatt 8 ports ? Or not Please explain me. Thanks/Barcelona
@CountryLivingExperience
@CountryLivingExperience 2 года назад
They changed the inverters over time and I don't know how old your first SPF5000 is. You may need a hub to communicate with with newer inverter.
@jacvanderspuy5618
@jacvanderspuy5618 Год назад
Great series. Why is it not a good thing to charge the batteries from the grid? I want to run my system without solar.
@CountryLivingExperience
@CountryLivingExperience Год назад
Thank you. The equipment is not made exclusively to charge batteries from the grid. It is made for solar.
@echopapa819
@echopapa819 2 года назад
Are you considering using Generator AC input to charge batteries when PV is not available? I found the RS485 vs BSM jack swap in the new units the hard way. I fully expect to use the system without PV connected as a stand alone battery backup.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Yes, I am going to buy a small 1k or 2k watt dual fuel generator to use with the dedicated battery charger. Sig Solar did a video about why it was not practical to hook a large generator into the inverters to charge the battery.
@user-ti9ck5mc6m
@user-ti9ck5mc6m 2 года назад
It's a great video, thanks to you
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Thank you
@AS-cd5wf
@AS-cd5wf Год назад
Hi there! Just saw your video today after installing two of the very same Growatt Inverters. Following the manual in setting up the PAL setting, I‘m unable to access the menu point 23. I‘d very much appreciate if you could write down the step by step procedure on how to enter into the stand by mode and set the menu point 23 to PAL and safe that setting. Many thanks for your great helpful videos and your effort. Greeting from Hungary!!
@CountryLivingExperience
@CountryLivingExperience Год назад
You have to enter in to the menu when it is in standby mode with the inverter switched off.
@yasasjayasuriya1258
@yasasjayasuriya1258 Год назад
@CountryLivingExperience First of all thanks for the video, and it's help me a lot. I live in area where lightening would be happened a lot. So I initially planned to disconnect my PV array when there will be high lightning, in order to protect my system. My solar panels were installed on roof (little bit high point) and my house located in kind of valley. So what will happen, if I disconnect my PV array, without switch off the growatt inverter and battery pack?
@CountryLivingExperience
@CountryLivingExperience Год назад
If everything is grounded properly and has the correct isolation breakers installed, it should not be a problem. If you have them on the roof, they should be installed with some sort of DC breaker for overcurrent protection.
@dalethefarmer
@dalethefarmer 2 года назад
You were told not to run power to the AC out if solar is not connected? That doesn't make sense, can you not run these overnight when the PV system is creating zero power?
@CountryLivingExperience
@CountryLivingExperience 2 года назад
I was surprised also. There was a technical reason I was given by SIg Solar. (I don't fully understand it). Give them a ring, I am just relaying the info.
@timbensing1075
@timbensing1075 2 года назад
You can power up the inverter, as long as you have at least one power source available. ( grid/solar/ or battery) I currently have my growatt spf5000es connected to grid only. It's powering my loads through my sub panel. My solar panels are arriving tomorrow and the batteries are stuck on a ship waiting to be unloaded. I powered up by grid only, so that I could figure out how much I could put on it. And, to get my loads balanced while I waited for the solar panels and batteries. It's working fine and I have everything powered and waiting for the rest of my system.
@nhattruong322
@nhattruong322 2 года назад
Thank you for the video. This is the information I am looking for. Never thought I will be interested in solar until I see David poz and your video, so I know the system is really work. I already bought the same system that I saw in your video just not install yet. I am really enjoying your channel because I love doing garden too. Are you using your solar power every day or just for back up? I already have a transfer switch installed and used it when the power is out now, I can use it for those chosen breakers every day by solar power if it goes well, I will expand later as you mentioned in the video. Great videos thank you!
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Thank you, I appreciate it. I am using it on most days. I am currently adding some batteries and cleaning up the wiring so the system is down at the moment.
@Starkchris
@Starkchris 2 года назад
As a lifer electrician and professional solar installer. I’m very curious if there’s a fault in your house panel/critical loads panel and it travels through your input or output wires without be bonded how will it clear the fault and not fry your inverters. Putting a ground to a ground rod will do nothing.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
I had an electrician look at this and they had no issues. This is also how Signature Solar recommended. Before they opened the business, they were professional installers for 10 years. So, whom do I believe? If I have a fault on the AC side, will it not just travel to ground through my main panel which also has a ground rod?
@Starkchris
@Starkchris 2 года назад
@@CountryLivingExperience if a fault happens on your ac side of inverter it has nowhere to go. The ground rod is useless it’s for lightning strikes not clearing fault currents. All metal parts need to be bounded
@Starkchris
@Starkchris 2 года назад
I would love to hear how and why from signature solar and or grow watt why you would put there system on it’s on ground rod for fault current and how it will work.
@Starkchris
@Starkchris 2 года назад
@@CountryLivingExperience at this time your ground rod is acting as a auxiliary electrode 250.54 in addition to bonding 250.30. Your videos are great. I just like info that can be deadly to be accurate. A lot of electricians have no idea what they are’s looking at and don’t know proper wiring methods for a safe and effective equipment. The inverter company is giving false info and I might have to start calling them on it.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
I appreciate everything you have said but you have not given me your solution.
@JayDee25895
@JayDee25895 2 года назад
yup
@a.t.7279
@a.t.7279 Год назад
Good video, thanks
@CountryLivingExperience
@CountryLivingExperience Год назад
You're welcome
@912ruckus2
@912ruckus2 2 года назад
talked me out of growatt before even half way through. Thanks!
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Why?
@giollaliddy5817
@giollaliddy5817 10 месяцев назад
13:08 you mention you that charging batteries form the grid is not a good thing to do for the health of entire system. Why is that? I thought this is common if you want to charge batteries for during cheap night rates. you can restrict amps in another settings. I just cannot see a reason why this would be bad
@damaha5
@damaha5 2 года назад
I find your videos really informative and do enjoy the presentation. I see each inverter has a battery connection but can’t see how you’ve connected them up. Do both inverters go back to the same battery bank and if so how do they connect to the same bank. Cheers David from NZ
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Thank you. The battery rack has integrated buss bars. All batteries and inverters are connected to them. I did a video on the rack and connections here......ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-SrCSSc9JYSo.html
@damaha5
@damaha5 2 года назад
@@CountryLivingExperience thanks Eric I watched the battery set up and again a brilliant presentation. Also your “is solar worth it” really lays it on the line well done. So just to be clear on the 2 inverter battery connection. Each inverter connects via the buss bar to the same battery bank? But the communication goes from the master battery to the master inverter right? Cheers David from NZ
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Thank you, I appreciate it. Yes, each inverter connects to the buss bar. The comms go from master battery to master inverter.
@lifewithlonsi
@lifewithlonsi 2 года назад
Any update on your grounding setup? I'm setting up two 3k 24v Growatts in split phase and have questions around proper grounding. Right now my plan is to bond the AC out grounds and neutrals to the off grid panel which will have it's own ground rod(s). I'm also wondering if I can ground the battery chassis and solar panels to the same rods.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
No update, it is setup as Sig Solar instructed and my electrician confirmed. If you purchased it from them, they should be able to help you with your particular setup. I don't know all the ins and outs of your system so I can't really say. Sorry, I am not more help.
@lifewithlonsi
@lifewithlonsi 2 года назад
@@CountryLivingExperience No worries - thanks. Yes I did purchase from them and have an email out to their support, never a dull moment!
@CountryLivingExperience
@CountryLivingExperience 2 года назад
You might want to try giving them a call. That has always worked quickest for me. I talk to Matt a lot and email him pictures of my equipment questions while we are talking.
@EduardoRodriguezRocks
@EduardoRodriguezRocks Год назад
Are you sure about having two grounds ? I was assuming everything was going into the same ground . Either case you can make a circuit over the ground
@CountryLivingExperience
@CountryLivingExperience Год назад
This is a discussion that has gone on inside the DIY Solar Forum and among many solar companies for a long time. I took the advice of the solar company I purchased from. If you don't feel comfortable doing it this way then do it how you feel is correct.
@troelsmejniche493
@troelsmejniche493 2 года назад
OBS! Connecting the "Current sharing ports" It is NOT korrect what You say in the video: 7:02 - 7:13/16:15 The "Current sharing ports" should NOT be connected left to left and right to right BUT left to right and right to left. Please read the manual ;-) :-)
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Mine works perfectly. I read the manual on camera. You misunderstood.
@andreapiccolo9773
@andreapiccolo9773 Год назад
I have a Off grid system not connected to the grid (no AC in). To have a 10-90% lithium battery discharge/charge what parameters should I set in program 12,13,21? (Inverter is Growatt spf5000es)
@icarus901
@icarus901 2 года назад
around the 13 minute mark, it was mentioned that AC/grid battery charging was a bad idea. Could you restate that point or recommend a resource to query on that aspect? I was surprised by it
@jfree9951
@jfree9951 2 года назад
Me Too. I think I checked with Sig Solar to confirm I don't really need the battery charger.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Watch Signature Solar's video on their 3kw (applies to all the off grid inverters) for generator sizing. @4:26 ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-RyAaR5UpB64.html
@icarus901
@icarus901 2 года назад
@@CountryLivingExperience AHH OK, now I understand -- thank you for referencing that timestamp. It's a voltage droop/frequency stability question for generator AC input. If I'm interpreting this correctly, it's largely non-issue when grid (not gen) supplemented for AC input. I use a dedicated DC charger sized for my generator in line with James' comment in the later moments of that video.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Yep. Sorry if I didn't articulate it properly in the video. I am still learning as I go sometimes.
@d0nt-rump202
@d0nt-rump202 2 года назад
Why not charge batteries via grid?
@Starkchris
@Starkchris 2 года назад
You can put your dc setup to a rod but your ac definitely needs to be bonded to panel.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
This comment seems contradictory to your other statement about the dc side.
@Jobbyhoyker
@Jobbyhoyker 2 года назад
Hi have you ever had An AC leak from the pv in to ground with these units. I copped a bad and unexpected shock from the pv DC in from the grow watt es5000 I own. I fear it is faulty but im just glad im not dead.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Wow, no I have not. That seems like a serious issue. I am not sure how that would happen. I would disconnect immediately and send it in for repair.
@Jobbyhoyker
@Jobbyhoyker 2 года назад
@@CountryLivingExperience thanks for your reply ive contacted the supplier and disconnect the unit.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
@@Jobbyhoyker Glad we could help and that you were not hurt.
@khalilsalam1500
@khalilsalam1500 2 года назад
in Ptcl why L01 ? is right ptcl number of battery or what thank you
@abubakarrdumbuya1405
@abubakarrdumbuya1405 Год назад
The problem I'm faced with, is that i have 4 12v 100amps lithium battery hooked up with my 13kva Growatt system in split unit. The issue is that i didn't hook the batteries on BMS, so i set my battery type to user2...i want to set my dod at 30 %, but the under setting 12, instead of Showing me the percentage, it showing me the voltage...so i want u to tell me which volt should i set it to obtain the 30% depth of discharge
@CountryLivingExperience
@CountryLivingExperience Год назад
I am not sure. I currently do not have these inverters connected because I am going to use them for another project. I am using the EG4 6500ex inverters now.
@TrytoCatch22
@TrytoCatch22 2 года назад
When you show your next video connecting everything. Please show how it is connected to your main panel!
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Hi. It is just wired into a breaker on the main panel. Nothing special. Neutral goes to the neutral buss bar, ground to ground and the 2 hot legs to a 70a breaker.
@TrytoCatch22
@TrytoCatch22 2 года назад
​@@CountryLivingExperience Ok, I guess that is easy enough. Do you think you will be able to supply the whole house with that 70 amp breaker? Even if you needed to run all your large appliances? Thank you for replying
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Yes. If you watch my earlier video I explain what my loads are (no stove, no water heater, no dryer). I am also switching my 3 ton air con to mini-splits.
@Just_An_Idea_For_Consideration
@Just_An_Idea_For_Consideration 2 года назад
Some questions: 1) are both inverters in phase with each other or are they 180 degrees out of phase? 2) i feel like there should be a main breaker between the inverter output and the autotransformer then from autotransformer into the distribution breaker box? opinions? 3) if the inverters are on same phase, do you just connect L1 and L2 together? 4) if the inverters are out of phase, do you consider only L1 from master to main breaker, and only L2 from slave to main breaker, but neutrals and grounds from each go to the main breaker box??? 4) what are the benefits of having the inverters in phase versus 180 degrees out of phase? Thank you for your responses.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
These are all questions beyond my knowledge. Please contact Signature Solar. This is in line with how I was instructed to install the system.
@Just_An_Idea_For_Consideration
@Just_An_Idea_For_Consideration 2 года назад
I was hoping you might ask this questions to Signature Solar the next time you speak with them. It is possible they also may not know the answers, but I think we all need to try and determine the answers. I do not have the equipment to do testing. I was hoping either you or signature would be able to figure it out, since you have access to the equipment. Thank you for your reply.
@timbensing1075
@timbensing1075 2 года назад
The inverters are in phase with each other. They're sharing the load. Mine is feeding a 50 amp 2 pole breaker, in a main lug sub panel. The auto transformer is connected at the main lugs. This way, it is protected by the 50 amp breaker. And if something goes wrong, the 50 amp breaker shuts down all power. If you put the auto transformer on its own breaker. And it trips that breaker. You only lose the neutral. Which can damage your 120 volt appliances.
@timbensing1075
@timbensing1075 2 года назад
Also, this inverters output is 240 volt. The purpose of the auto transformer is to create the neutral. And turn it into a 240/120 split phase.
@jfree9951
@jfree9951 2 года назад
@@CountryLivingExperience Excellent response. Thank you for documenting this!
@DOlalekan
@DOlalekan 2 года назад
Pls I have a question, the inverter AC output is it two phase ? In your last video you make mentioned of two hot line. Thanks
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Technically it is 240v single phase but it it called two phase here in the US. There is two hot lines and a ground.
@Uni12355
@Uni12355 Год назад
i do not know why the New Growatt 5000ES bonded the AC input Ground to The AC Output Neutral . I did openup the inverter trying to unbond the neutral & ground but i cant find where to unbond it . This is because i am using Solar to charge my batteries LIFEPO4 & same time power up my loads , just that when at night i requires the Grid to charge my batteries . Ended up it trips my main power ELCB and not able to get it function . Previously bought all the inverters are not bonded , need help what should i do to unbond the neutral and ground ? Do i need to use the dry contact to trigger the unbond ? thanks
@CountryLivingExperience
@CountryLivingExperience Год назад
Only Growatts sold by Signature Solar are properly modified for the US electrical grid. All others (as far as I know) do not have the bonding screw removed or the connection hole covered with silicone.
@muso31
@muso31 Год назад
Between the batteries and the inverter does it not require a device for over current protection?
@CountryLivingExperience
@CountryLivingExperience Год назад
I have them on my new system. The batteries have some good over current protection. As always, the more the better.
@sudokillall
@sudokillall 2 года назад
Any recommendations for 3 pole (split phase) transfer switch to feed utility's hot lines and neutral on one end and the Inverters' hots and the mid point transformer neutral on the other? That way I can either manually or automatically switch between electrical sources.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Sorry, I don't. Maybe your local electrical supply house.
@SpyTom1776
@SpyTom1776 2 года назад
Manipulating the controls with your hand on top of the positive battery cable looks dangerous. Are they covered normally or always exposed?
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Not sure where in the video you are talking about. I am always extremely safe.
@JamesLee-ey2yv
@JamesLee-ey2yv 2 года назад
Right off you got me confused. Your connecting your batteries and inverters on the DC side to it's own ground rod. ?? Do you mean the battery case is connected to the ground rod, also the DC side of the inverter??? The only DC connection on the inverter is the PV in which has a 2 wire connection. + and - . Where is the ground rod connected in the inverter?
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Battery case and AC out on the inverters are connected to ground rod as a separately derived system just like a whole house generator.
@presidentchaung
@presidentchaung 2 года назад
hi , my inverter and battery pack is in 4th floor of 6 stories building , pv wires and grid (ac input) hook up to inverter without grounding please tell me what should i do
@westking7746
@westking7746 2 года назад
So the AC and DC systems have separate grounding systems each with a single ground rod for each system? Is the combiner box a good place to ground the DC system?
@CountryLivingExperience
@CountryLivingExperience 2 года назад
The power from the inverter is AC so there is no DC power accept at the panels, PV wires, and batteries. The inverters are a separate power generation system like a generator in my off-grid configuration.
@c4inkb013
@c4inkb013 2 года назад
hello, thank u so much for this video! what type of ethernet cables do I need to buy?
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Your welcome. Just a regular ethernet cable will work.
@peterarzhenkov4984
@peterarzhenkov4984 Год назад
Sir, do you know the pin of the communication cable between inverter and BMS?
@CountryLivingExperience
@CountryLivingExperience Год назад
Sorry, I don’t know.
@ComputingCode
@ComputingCode Год назад
Quick question, is it OK to connect the inverter to AC IN without PV, Batteries, or AC OUT? Why I ask, I would want to startup the inverter inside the house so I can setup Wifi before moving into it's final spot where the Wifi is weaker.
@CountryLivingExperience
@CountryLivingExperience Год назад
If you have AC in the house already, why not plug the Wi-Fi into the house AC?
@ComputingCode
@ComputingCode Год назад
@@CountryLivingExperience ok, let me clear it up a bit. My growatt has a shine wifi dongle. I want to link that to my router wifi before installing the inverter to its final position. Is it safe to plug the dongle into a 5v source and set it up that way? Or must it be the inverter? My guess is the inverter since it would require a modbus connection to its host.
@CountryLivingExperience
@CountryLivingExperience Год назад
@@ComputingCode Honestly those are questions for the manufacturer. I cannot answer them and I don't use the dongle.
@kirkdis
@kirkdis Год назад
at 9:10 you want to switch to parallel but you quit the action and stick with two single inverters... don´t understand that
@CountryLivingExperience
@CountryLivingExperience Год назад
The setting did not stick in the video. I didn't realize it until I was editing the video. Follow the process that I mentioned and make sure the setting sticks.
@sudokillall
@sudokillall 2 года назад
I thought we don't use master/slave anymore. At least it's gone from the computer industry. I've shared your info in other videos and got some push back on the separate grounding and awaiting response from SS. Thanks for the informative videos
@CountryLivingExperience
@CountryLivingExperience 2 года назад
You're welcome. The inverters are called what they are called within the programming. Everyone has an opinion on grounding. This is how I was told to do it by SS and my electrician.
@sudokillall
@sudokillall 2 года назад
@@CountryLivingExperience ah, thanks for confirming. There's an on going discussion about that here with SS, ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-90O_iGjfm28.html in the comments where I referenced your video. I'm trying to get a collective opinion about this in order to have a flawless setup :)
@uhjyuff2095
@uhjyuff2095 2 года назад
SS is telling you to connect the ground lug on the inverters to a ground rod. I believe you already have a ground rod by your electric meter, so just connect the ground wire to your panel you have next to the inverters and that then goes to your main panel of your house which has the ground rod. I say this because multiple ground rods in different locations is how to make your electrical system less safe when a real lightning event happens. One location ground rod is so the lightning doesn't jump through the walls of your house between the two ground rods and energize all the copper wires in your house in the walls to 1 million volts!
@diysolaradventures7894
@diysolaradventures7894 2 года назад
The grey box with the switch on it is that ur ac 120 output that's where I think I got lost i never seen u actually hook that particular box up
@CountryLivingExperience
@CountryLivingExperience 2 года назад
That small grey box is just a safety switch. It is located on the AC side conductors. It takes the AC power to my main panel. Both 240 and 120.
@diysolaradventures7894
@diysolaradventures7894 2 года назад
@@CountryLivingExperience ohh ok that's the part I really wanted to see u do thanks tho
@diysolaradventures7894
@diysolaradventures7894 2 года назад
@@CountryLivingExperience hey can I use a simple step down transformer with these 240v inverters I was going to wire a simple step down 240v to ac 120v would that work one of those step-down boxes
@shadowmoon7763
@shadowmoon7763 2 года назад
Can you tell me when paralleling, do you have to program the second unit also, or does it get he settings from the primary/master unit?
@CountryLivingExperience
@CountryLivingExperience 2 года назад
You do not. The second inverter will pick up the programming from the master unit.
@fairadvice3639
@fairadvice3639 2 года назад
Why is it bad for the inverter to charge your batteries from the AC grid or generator as you say? Is the a problem with the design? If someone on the grid without solar and wants to use the invertr as a backup unit, you need to charge from the power line!
@CountryLivingExperience
@CountryLivingExperience 2 года назад
No problem with the design, it is just not recommended for the heath of the equipment to do that. The batteries are made to receive charging power from 48v solar or from a 48v battery charger. Additionally, it is not cost effective. You need to purchase the appropriate battery charger for your batteries. The inverters charge via solar most effectively.
@waydeross
@waydeross 2 года назад
Pv voltage incoming can be much higher than 48v.. some inverters up to 450 volts dc. Hybrid inverters are smart enough to charge your system from grid in the event you have no electricity from pv array. If you have poor sunlight in the day and haven't managed to charge your batteries the grid is the only solution to assist.. inverters will regulate battery charge whether from PV or Grid.
@waydeross
@waydeross 2 года назад
From a cost effective point of you YES charge with solar. Personal settings are charge first with solar. In the event pv is unavailable batteries are low and grid is available the grid will assist with charge.
@eddietee6305
@eddietee6305 Год назад
@@CountryLivingExperience I'm wondering why someone on a solar system would want to charge from grid. Why go solar then?
@CountryLivingExperience
@CountryLivingExperience Год назад
@@eddietee6305 True
@armourofgod6310
@armourofgod6310 2 года назад
I have a growatt for off grid and I use a generator, now do I have to hit the switch manually to power my growatt with gas generator or does the unit to automatically?
@CountryLivingExperience
@CountryLivingExperience 2 года назад
It all depends on how you wired it.
@jeffmotes2129
@jeffmotes2129 Год назад
I’ve set mine up like you’ve shown and also with setting 5 to LI and setting 36 to L01. My inverters are limiting charging current to 10A regardless of source and regardless of available solar power. Any idea why?
@CountryLivingExperience
@CountryLivingExperience Год назад
Not sure. I know you cannot adjust it via the settings if you have Lithium. Your BMS should be regulating this. Do you have the BMS communications set up correctly?
@jeffmotes2129
@jeffmotes2129 Год назад
@@CountryLivingExperience I set it up like signature solar’s setup video. I’ve change to USE2 and can charge at higher currents. But only 10A when set to LI / L01. I have reached out to signature solar but they are very slow to respond.
@CountryLivingExperience
@CountryLivingExperience Год назад
@@jeffmotes2129 Not sure why. Leave it on USE2 until you can get hold of them.
@system-4210
@system-4210 2 года назад
Please help: I have a growatt 3000 and it doesn’t recognize my PV input at all. My panels are in series. 8X370 watt panels. I have a pv shut off switch hooked up. Any thoughts?
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Check if you have the correct voltage or if your pv wires are reversed in their polarity.
@BackboneNF
@BackboneNF Год назад
Does the growatt take 9x 550w panels in series with 49V voltage ?
@CountryLivingExperience
@CountryLivingExperience Год назад
It should. Max PV wattage is 6000w for the Growatt. Max voltage in is 450vdc.
@diysolaradventures7894
@diysolaradventures7894 2 года назад
I just watched this video I still don't see no emphasis on the 120ac current wiring coming from the solar edge mid point transformer box you showed how to wire into the box but I never seen you show how to wire out of the box
@CountryLivingExperience
@CountryLivingExperience 2 года назад
There is no 120 coming from anywhere. The mid-point transformer splits the incoming 240 into 120 on the neutral leg. Watch this video from Signature Solar to help....ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-NVnJhFxCFHw.html
@diysolaradventures7894
@diysolaradventures7894 2 года назад
@@CountryLivingExperience that's what I was talking about once u wired the neutral and both inverters and the solar edge to the circuit breaker box u really didn't go in to much detail about the 120 ac I watched the signature solar video and that's how I was able to figure it out all I was saying if you didn't go into too much detail on the 120 AC output which was the whole purpose for the solar edge converter
@gigel99324
@gigel99324 Год назад
Can you use a DIY battery (cells + BMS) with Growatt inverters?
@CountryLivingExperience
@CountryLivingExperience Год назад
Yes
@FraLin
@FraLin Год назад
why you published a video about second hand knowledge from SS?
@CountryLivingExperience
@CountryLivingExperience Год назад
What is your issue?
@MarkSmith-Uzor
@MarkSmith-Uzor 2 года назад
Please why is it a bad idea to charge the batteries using the growatt inverter from the ac grid?..
@CountryLivingExperience
@CountryLivingExperience 2 года назад
It is not a bad idea per say but it is not really efficient or cost effective.
@secondadventmessengerminis3594
@secondadventmessengerminis3594 8 месяцев назад
Hello again. Hope all is well. Question: how can I tell if I have the newer ES5000 or the older one. I purchased them in June 2022. I am running into trouble with my Growatts charging my EgLL’s. Wondering do I need the communication cables. Please advise.
@CountryLivingExperience
@CountryLivingExperience 8 месяцев назад
I'm a little confused. Is the system up and running? If so, it should have comms cables already connected. I just don't know how your system is set up.
@secondadventmessengerminis3594
@secondadventmessengerminis3594 8 месяцев назад
@@CountryLivingExperience Thanks for your response. It is up and running. However, I do not have the gray communications cables. Not sure if they should come with inverters or should I buy them. Wondering if this is my missing link. System works fine, but intermittently the inverters are not charging the batteries.
@CountryLivingExperience
@CountryLivingExperience 8 месяцев назад
@@secondadventmessengerminis3594 I honestly don't understand how it is running without those communication cables. They come in the boxes with the inverters and there are instructions in the manual on how to connect them. This may be the issue with your charging problem or may not be.
@secondadventmessengerminis3594
@secondadventmessengerminis3594 8 месяцев назад
My mistake, my error. It turns out that that isn’t not missing. What I just learned is that I need to update the firmware. Thanks for your raid response. Blessings
@CountryLivingExperience
@CountryLivingExperience 8 месяцев назад
@@secondadventmessengerminis3594 Glad you got it worked out
@planchancho
@planchancho 2 года назад
Have the older model es and a new model es. Cannot get them to parallel. Have you any feedback on that. Signature is no help.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Sorry, I don't know why that would happen. I purchased both of mine together. Not sure why Signature is no help.
@Xxxcappie23
@Xxxcappie23 2 года назад
What wires/cables are connected between the two inverters to parallel the?
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Each inverter comes with special wires for connecting in parallel
@DaxPallotta
@DaxPallotta 2 года назад
Did to come to a decision on whether or not to ground your batteries? Have you grounded your case? I have the exact same setup and I was curious of what you decided?
@CountryLivingExperience
@CountryLivingExperience 2 года назад
I grounded the metal rack that holds the batteries.
@DaxPallotta
@DaxPallotta 2 года назад
@@CountryLivingExperiencecouple questions for you.... Did you use the same guage wire as your + and - ? Did you take the ground that is attached to the case out to the grounding rod you showed in your video?
@CountryLivingExperience
@CountryLivingExperience 2 года назад
I used an 8ga bare copper ground that does go out to my separate grounding rod.
@motoozark4361
@motoozark4361 2 года назад
@@CountryLivingExperience Is that in case lightning hits your batteries some how? As far as I know voltage will always find a way back to its source. I wonder if you wouldn't be better off grounding your batteries to your Inverter case.
@OffGrit
@OffGrit Год назад
Hey! Great video! I guess I missed it but at that subpanel are you neutral bonded there or are these inverters neutral bonded? Just curious on that. Thanks!
@CountryLivingExperience
@CountryLivingExperience Год назад
Hello. No neutral-ground bond in the inverters or sub-panel. Only bond is at the main panel.
@OffGrit
@OffGrit Год назад
@@CountryLivingExperience it's interesting because I actually have a couple of those grow out inverters and from what I've been seeing, there is actually a ground neutral bond inside those inverters and a lot of people break that bond inside the inverters when they're setting up their panels. So there's not two references to ground when they're running specifically off of batteries. At least that's what I've seen
@OffGrit
@OffGrit Год назад
Growatt (speech to text)
@CountryLivingExperience
@CountryLivingExperience Год назад
The Growatts that have a neutral ground bond still in them are not made for the North American grid. The only authorized dealer in the US (that I know about) is Signature Solar. They worked with Growatt directly to modify the inverters for our grid including taking out the internal bond.
@zuzax1656
@zuzax1656 2 года назад
I know you have stated that you are off grid, so no connection at all to your local power company. But, I don't think you've talked about selling power back to the utility, which would require a connection. Does the system you have support that? If so, is it worth it (connection fees vs. income from selling power)?
@echopapa819
@echopapa819 2 года назад
The Grid connection to sell power back is on the output side, not the input side. My opinion is selling back to grid means you have too large an array for your needs or you don't have enough battery storage.
@zuzax1656
@zuzax1656 2 года назад
@@echopapa819 So what do you do when you're out of town for the weekend? Do you think the PV system only makes electricity when you are at home? It is like any other electrical source, the power is there, it just isn't flowing (when the sun shines, that is). If the there is minimal drain, like you are not home, and the batteries are fully charged, the PV system can still create electricity that can be sold back to the utility. Electricity flows in both directions.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
I mentioned in another vid that I had a few friends that were grid tied. They have been attempting to sell power back in our area but have had complications. In our area, even if you are grid tied and selling power back, you must pay a minimum connection fee (usually $20/month). While this is a tiny charge, you will never have a "free" month of power. They have had difficulty getting a proper report from the power company on how much they have sold back and have had a few months where they had to pay a power bill (beyond the $20) even though they had build up a large credit from previous days/months. I purchased the off-grid inverters. If you want to sell back, you will need to buy a grid-tied inverter. More difficult and complicated connections, slightly higher equipment prices. Personally, I did not think it was worth the hassle.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
@Echo Papa Good points
@smccomas01
@smccomas01 2 года назад
@@CountryLivingExperience In the video you mentioned not having a tie to the grid now I understand why thanks.
@eddietee6305
@eddietee6305 Год назад
Your transformer only has 1 conduit - for primary and secondary conductors?
@CountryLivingExperience
@CountryLivingExperience Год назад
That syle of transformer from Solar Edge only used one set of conductors.
@eddietee6305
@eddietee6305 Год назад
@@CountryLivingExperience ok. Most likely it's an auto-transformer.
@CountryLivingExperience
@CountryLivingExperience Год назад
@@eddietee6305 It is.
@JamesLee-ey2yv
@JamesLee-ey2yv 2 года назад
@ 9:00 your setting #23 to PAL, The master and Slave 1 at the same time. I have 4 inverters, Can I set them one at a time starting with the master then S1,2 then 3 or do I have to shut of all 4 and set them at the same time. This probably is a strange question, but I'm at the point that everything is wired up except my PV and I am about to turn them on for the first time and I'm am a little nervous.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Don't be nervous, you can do it. The inverters cannot be set as master, slave, etc internally. It is based on the order in which they are turned on. I didn't see a specific question in your comment....what is it?
@JamesLee-ey2yv
@JamesLee-ey2yv 2 года назад
@@CountryLivingExperience I turned on my inverters with battery power and programed them and All is well. I have 14 more panels to install and wire up and in about 1 or 2 weeks ( depending on the Weather) I should be running on Solar power. Thanks for your videos, they were and are a big help.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
@@JamesLee-ey2yv Awesome!!! Glad we could help.
@todamnbad
@todamnbad Год назад
Do you know how to turn the annoying beep off when you push buttons
@CountryLivingExperience
@CountryLivingExperience Год назад
Setting 15 should take care of that.
@todamnbad
@todamnbad Год назад
@Country Living Experience: A Homesteading Journey oops, should have deleted my question, I found that a 1 second push of the down & enter button turn it off
@rukundojobson2249
@rukundojobson2249 2 месяца назад
Can I parallel 5kw and 6kw both of 48V rating growatt inverters?
@CountryLivingExperience
@CountryLivingExperience 2 месяца назад
I don’t think so. The communication protocol might be different and they won’t talk to each other
@rukundojobson2249
@rukundojobson2249 2 месяца назад
@@CountryLivingExperience Thank you. I have the two units but I am afraid to try paralleling them.
@momenphone
@momenphone 2 года назад
I have two spf5000es parallel in same phase as your system and i have felicity lifepo4 battery , i tried to connect rs485 cable from battery to master inverter but the communications faild. In my cable i am using pin 1,2 at inverter side and 5,6 at battery side. Can i know what pins are you using in your eathernet cable?
@CountryLivingExperience
@CountryLivingExperience 2 года назад
I am unfamiliar with Felicity batteries and whether they have to ability to communicate with Growatt inverters. If you purchased the Growatt from Sig Solar, please refer to them for assistance.
@momenphone
@momenphone 2 года назад
@@CountryLivingExperience thank you , but how i can check if my inverter old or new model . Also can you please let me know your patched cable pinout direction
@CountryLivingExperience
@CountryLivingExperience 2 года назад
@@momenphone I am not sure what you mean by pinout. The top battery needs to have the DIP switches in a specific configuration but that is only with the EG4-LL batteries. I do not know how the other batteries communicate with the inverters. You need to contact Growatt for information.
@ruwankumara6226
@ruwankumara6226 Год назад
Hi how we keep fan Stand by mode
@CountryLivingExperience
@CountryLivingExperience Год назад
That is not possible.
@Xxxcappie23
@Xxxcappie23 2 года назад
Are the output AC wires for these parallel inverters connected together in a circuit breaker ?
@CountryLivingExperience
@CountryLivingExperience 2 года назад
We have another video on that. They are each on a separate circuit breaker.
@Xxxcappie23
@Xxxcappie23 2 года назад
@@CountryLivingExperience plz put up the link for that plz
@CountryLivingExperience
@CountryLivingExperience 2 года назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-N-d3lCVUeyA.html
@benc1927
@benc1927 2 года назад
How do you make sure you don't push power back to the grid
@CountryLivingExperience
@CountryLivingExperience 2 года назад
The generator interlock kit that is installed on the main service panel. I can never have the main grid breaker on at the same time as the solar system feeder breaker.
@benc1927
@benc1927 2 года назад
@@CountryLivingExperience Figured you could just use those current transformer clips to inhibit the back flow like enphase does
@robertsanchez5279
@robertsanchez5279 2 года назад
Can they work without battery bank just Sun and AC company on night?
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Not this particular model.
@chuxxsss
@chuxxsss 2 года назад
My unit doesn't even turn on without grid power. No display with batteries.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
You may have a defective unit or it is a different type than mine or you don't have any batteries connected.
@chuxxsss
@chuxxsss 2 года назад
@@CountryLivingExperience Batteries connected.
@daviddarnell8898
@daviddarnell8898 2 года назад
Ethernet cables have RJ45 connectors.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
The cable I used works fine.
@bigblockcutlass123
@bigblockcutlass123 2 года назад
Did your batteries come with power cables and the communication cables?
@CountryLivingExperience
@CountryLivingExperience 2 года назад
They come with the small jumper communication cables and the short battery cables for paralleling or connecting to the rack buss bar. The rack comes with long battery cables to run to one inverter. I purchased extra battery cable at my local auto parts store.
@Tuggs
@Tuggs 2 года назад
Local wielding supply is also another good place to source battery cable.
@shermdog6969
@shermdog6969 2 года назад
I'm worried that these new inverters have a lot of controls that it allows for more failures especially when you're off grid. I want something extremely simple.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Even the simplest inverters have delicate electronics.
@shermdog6969
@shermdog6969 2 года назад
@@CountryLivingExperience very true. But my 78 Chevy has less problems than my wife's 01 Toyota. And it's always the electronics.😁
@CountryLivingExperience
@CountryLivingExperience 2 года назад
@@shermdog6969 You can only do your best and find the best you can. My 76 Malibu had more problems than my 03 Honda. My 94 Pontiac was a lemon but my 05 Explorer is bullet proof.
@shermdog6969
@shermdog6969 2 года назад
@@CountryLivingExperience I know I was just making a joke. We just hope for the best.
@omarbarakat61290
@omarbarakat61290 2 года назад
Hi man. A have a problem in my inverter. It shows me 07 error witch mean overload timeout. What is this problem. I don't have a load only 25 %
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Not sure. Did the breaker trip? Try shutting down and taking off the batteries. Then reconnect and start up again.
@omarbarakat61290
@omarbarakat61290 2 года назад
@@CountryLivingExperience when i turn off and then off thr inverter it works fine. This error shows every 2 to 3 days once or twice a day... anw thanks a lot man
@CountryLivingExperience
@CountryLivingExperience 2 года назад
@@omarbarakat61290 Sorry I could not help more.
@martinhrabe9888
@martinhrabe9888 2 года назад
I've noticed in all the videos I've watched on the Growatt 5000 nobody has installed a fuse from the batteries to the inverter? Unless I'm missing something. I'm trying to find out what size I need from the 6 EG4's to the inverter.
@CountryLivingExperience
@CountryLivingExperience 2 года назад
With the breakers on the batteries and Growatt, I didn't think it was necessary. I suppose a 200amp would work but an electrician could size one better for you. I am actually going to be installing some new inverters soon and I will have 200A breakers on the battery cables for those.
@gxmario_13jf94
@gxmario_13jf94 2 года назад
hello sorry if I disturb you or just installed my growatt 5000es or connected the lithium battery 48 volt 100ah with voltage 52.5 volts or tried to turn on and it did not turn on you can help me please thank you.Then or connected the 230volt network and it turned on but at the output it did not give me the 230volt to power the loads, and despite the battery is connected as soon as I remove the 230volt utility
@CountryLivingExperience
@CountryLivingExperience 2 года назад
Sorry, I would talk to the place you purchased it from. I have no idea how you set up your system and wired it.
@gxmario_13jf94
@gxmario_13jf94 2 года назад
A thousand thanks
@gxmario_13jf94
@gxmario_13jf94 2 года назад
hello the problem of turning on the inverter and was solved it was a disconnected plug on the motherboard now it works correctly but still another problem The inverter charges the battery to 50% and then stops charging maybe you have to configure some parameters?
@CountryLivingExperience
@CountryLivingExperience 2 года назад
@@gxmario_13jf94 There is a parameter for that. You should find it in the manual.
@gxmario_13jf94
@gxmario_13jf94 2 года назад
Thanks again
@bigblockcutlass123
@bigblockcutlass123 2 года назад
Does your inverters keep charging the batteries when they're turned off
@CountryLivingExperience
@CountryLivingExperience 2 года назад
No, the inverters are always on.
@chrisloving6647
@chrisloving6647 2 года назад
If I flip the switch on mine it just killed the AC and keeps pulling from the pv
@bigblockcutlass123
@bigblockcutlass123 2 года назад
On my 12K growatt, if I turn the inverter off the charge controllers stay operational. My problem is right now they're only 250 volt PV. I'm thinking about buying one of these 5K just for the charging because of the 450 volt Pv charging. The inverter would be just a plus for a backup. Can't seem to buy just a charger that's more than 250 volts.
Далее
The GOOD and the BAD on the Growatt SPF5000es
10:17
Просмотров 56 тыс.
Growatt WiFi Setup
11:10
Просмотров 141 тыс.
Growatt Settings LiFePO4
9:14
Просмотров 50 тыс.
Beginner Friendly 48V Solar Power System! Step by step!
12:14
Off Grid Earthing & Bonding Made Simple | ØY17
21:44