Solar Panels & Battery Storage - Prosumer Electrical Installation Tech Tour 

eFIXX ENERGY
Подписаться 7 тыс.
Просмотров 67 тыс.
50% 1

Опубликовано:

 

5 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 183   
@sea-saw2654
@sea-saw2654 2 года назад
Clearly know what your doing and a great job overall but my ocd was wishing you vacuumed that brick dust …
@neilbissett1240
@neilbissett1240 Год назад
Me too 😂
@NikolaGluvakov
@NikolaGluvakov 3 месяца назад
That's exactly what I thought!!!
@PeterTwo-qm3xk
@PeterTwo-qm3xk 2 месяца назад
Yep I'd want the brick dust hovered up before it gets into switches / isolators or any vents in the battery packs.
@Wintersky136
@Wintersky136 2 года назад
3:14 how about a little vacuuming? 🙄
@jeffzuess9149
@jeffzuess9149 2 года назад
Sloppy with not brushing off the brick dust from the bricks and trunking created from drilling the holes. Makes it harder to do with all the equipment in place.
@craigandsummer4057
@craigandsummer4057 Год назад
Not sure about the safe working practices as well when testing the PV voltages
@gbentley8176
@gbentley8176 Год назад
@@craigandsummer4057 Agree dangling wires in loft and cutting both at the same time invites a short circuit. No strain relief gland for battery cables into the trunking?
@roryokeeffe9772
@roryokeeffe9772 Год назад
A lot of positive comments on that install. Quite clear many of them don’t do solar then !!! There are quite a few mistakes here . Suprised Gaz didn’t spot them, being the expert
@rogerwells8822
@rogerwells8822 Год назад
Makes such a difference to clean as you go.
@ludobrevbg
@ludobrevbg Год назад
Why didn't you vacuum the dust off the bricks?
@solarrover9575
@solarrover9575 Год назад
Making off live dc mc4 connectors is so rough. Nearly 300v dc. I’m surprised efixx show this practice. You should terminate into your dc isolator supply side before connecting the last panel. You the check you voltage before coming out of your load side with the correct m/f mc4 connectors.
@sdgelectronics
@sdgelectronics Год назад
Was thinking the same thing. Some serious risks taken here, even holding each stripped PV cable in each hand whilst measuring the voltage!
@sbmorris2k6
@sbmorris2k6 9 месяцев назад
So connect ends into dc isolator then make off the other ends to connect to pre wired panels? What’s the safest way of disconnecting panels, I know you isolate the ac then the inverter/dc isolator, is it then safe enough to pull the mc4 connectors or will you still get arcing ?
@sdgelectronics
@sdgelectronics Год назад
This installer is lethal, surprising you left some of the content in the final edit.
@johndoe2769
@johndoe2769 2 месяца назад
Whats lethal about it. can you explain further
@brucerobson8767
@brucerobson8767 2 года назад
Storage battery capacity is measured in Kw hrs, not Kw! Note electricity meter is an older induction disc type. This will run in reverse when PV generation exceeds customer consumption (including batteries). Although this may seem advantageous, It is not permitted ( illegal) by REC
@Soruk42
@Soruk42 2 года назад
Not always true, my parents' spinning disc meter doesn't go backwards when exporting.
@grahamheath9957
@grahamheath9957 Год назад
@@Soruk42 correct, I had a meter with a ratchet that didn’t go backwards. However in the case of my meter (same style as the one in the video), it had a ratchet symbol on the front face of the meter, which this one seems not to
@solarrover9575
@solarrover9575 Год назад
They don’t always run backwards and it’s not “illegal” ffs. It’s the electricity suppliers equipment so it’s up to them to ensure it’s working as it should.
@mikethemask1525
@mikethemask1525 Год назад
When did we start feed sockets by flexes strange as I'd say a socket is fixed and should have fixed wiring it's not an appliance
@MattGriffin1
@MattGriffin1 Год назад
if there's no load on that 25m dc cable, shouldn't there be no voltage loss? hmmm
@99heinze
@99heinze 2 года назад
Thanks Gaz. This is great. I’ve just got my BPEC qualification and am starting out on my solar journey. Currently working with a local installer learning on the job. More of this would be a great help to others, I’m sure. Thanks again.
@michaelsmallwood6002
@michaelsmallwood6002 8 месяцев назад
Grate video, Shouldn't the EPS socket be rcd protected ?
@Wintersky136
@Wintersky136 2 года назад
5:55 having DC PV cables together with DC Battery cables and AC grid cables in the same trunking is just WRONG!
@deanofakesie8153
@deanofakesie8153 2 года назад
Why don't people ply the wall 🤦🏼‍♂️ So much neater and easier for install
@bramcoteelectrical1088
@bramcoteelectrical1088 2 года назад
I always ply my grow watts where i can costs around £130 extra but makes install tidy as...
@sergiofernandez3725
@sergiofernandez3725 2 года назад
Nice setup. It's a shame the homeowner did not get the wall painted nicely before the kit was put on the wall
@jeffzuess9149
@jeffzuess9149 2 года назад
Agreed I would have painted the wall before hand.
@OriginalNoseBleed
@OriginalNoseBleed 2 года назад
I actually thought the same thing lol
@muso31
@muso31 7 месяцев назад
Brilliant vid, if there's over 200V in the cables why is he able to touch the end without a shock?
@stjernkvistj3666
@stjernkvistj3666 5 месяцев назад
He have to touch both at the same time
@-galaxy5413
@-galaxy5413 6 месяцев назад
Few things picked up on, mc4 in the loft are fitted wrong way round, “male” pin goes in the “female” side of the mc4, no need for labels on installs as of 2nd amendment only label needed is a solar array sticker near point of isolation for fire fighters and the solar array label should never be stuck on a paintable surface, also no need for a generation meter on installs anymore as suppliers will not accept readings from them, only from CT clamp readings at the incomer
@kevinpickett7249
@kevinpickett7249 2 года назад
Great video and great team considering it’s ( in roof system ) 2 days 👍
@fjspicer1
@fjspicer1 Год назад
@eFIXX ENERGY I know every install is different but it would be good to have some idea of the cost of this install
@lunamonkey
@lunamonkey Год назад
I don’t understand why an EPS is extra during a power cut but all the house runs from batteries during normal operation. Why is the grid needed for normal operation?
@matthewmarks6951
@matthewmarks6951 5 месяцев назад
It's grid tied, which means that with the aid of the current transformer it will supply as much as it can to the house, but if the house wants to draw more power than the inverter can supply, it's automatically supplemented by the grid. Grid tied also means that the inverter stops outputting in a power cut to protect people who might be working on the electrical supply, so in that case you must use the isolated EPS output.
@hein_mcleod
@hein_mcleod 2 года назад
You're only supposed to strip the solar cable isolation between 8 to 11mm. Way too much excess inside the mc4 terminal. In South Africa, you're not allowed to have AC and DC in the same trunking run. I'm surprised that it's allowed in the UK of all places.
@Matt-bt7ej
@Matt-bt7ej 2 года назад
14:30 the volt drop statement doesn't make any sense does it? Drop measured by a high input impedance volt meter with no other current being taken from the cable. Ohms law should tell you where you have gone wrong there....
@stevec00ps
@stevec00ps 2 года назад
You can't really compare at two different times either, might have a cloud overhead :)
@matthewmarks6951
@matthewmarks6951 5 месяцев назад
@@stevec00ps That will be entirely responsible for the 1 volt "drop"! (With no load, PV voltage varies only slightly above a certain minimum level of light.)
@Wintersky136
@Wintersky136 2 года назад
9:00 how about installing the PV cables in some fireproof cable ducts or some fireresistent cable trunking?
@Tannerx99
@Tannerx99 2 года назад
Do you want to complain any more?
@bramcoteelectrical1088
@bramcoteelectrical1088 2 года назад
What?? issue is loose connections for most pv fires or poor mc4 connections or junction boxes
@Nicolas-qb3yg
@Nicolas-qb3yg Год назад
@@bramcoteelectrical1088These installation might have been made with MC4 connectors made without a cramping tool!
@shilks8773
@shilks8773 Год назад
It would have been far safer to fit each socket on the end of each solar panel cable as they are cut to length (09:13) rather than have lots of live ends dangling about. He needs to think a little more about safe working practice(s). Also having identified the polarity of the cables - a bit of Brown & Blue sleeving over the Solar Panel cable ends would be useful if any future maintenance becomes necessary - or using the appropriate coloured ferules on the cable ends. Are the cables pairs also identified as to which panel they belong to ?. I see far too many installs done that do not document the cables / items that they belong to - so the next guy that comes to do any work on the cables/item knows what is going on.
@hannesviljoen8434
@hannesviljoen8434 Год назад
As an amateur I thought the same. Would you add fuses while adding the MC4 connector (even if it's not a legal requirement)? Is there a downside to adding fuses apart from costs? Same with the absence of T-fuse between battery and inverter. Looking for a professional opinion on fuses. TIA!
@sdgelectronics
@sdgelectronics Год назад
@@hannesviljoen8434 Yes, should install fuses between battery and inverter. Also surge protection is a requirement.
@Nicolas-qb3yg
@Nicolas-qb3yg Год назад
The easier : buy black and red DC cables : no confusion!
@matthewmarks6951
@matthewmarks6951 5 месяцев назад
@@Nicolas-qb3yg I was just going to say it would be rather odd to put brown and blue sleeving on DC cables!
@synthwave7
@synthwave7 2 года назад
Wow - what a great video. This was super useful. Thanks for taking the time to do this.
@_a.z
@_a.z Год назад
14:10 Voltage drop? Without a load? .. I think the light level might have changed slightly! Any losses will be within the panel, not the cable!
@kevanswift7797
@kevanswift7797 4 месяца назад
That voltage drop of 1 volt was on no load so will be a lot more when powered up to inverter
@nathanledden3892
@nathanledden3892 2 года назад
Surely this would be better on a automated contactor to change over on event of a power cut for the whole system? Like a back up generator change over switch.
@Iansproat-MJEphotography
@Iansproat-MJEphotography 5 месяцев назад
300mm to the nib? No fuses to DC cable from inverter to battery as there no isolation?
@RayonWhittaker
@RayonWhittaker Год назад
Awesome video... We really appreciate the questions and the explanations during the setup. GREAT JOB!!!
@EenNx
@EenNx Год назад
Great Video on the electric system, very informative and fun to watch
@WizardNumberNext
@WizardNumberNext 10 месяцев назад
I haven't seen earthing for EPS EPS socket have to be earthed separately. In event of neutral loss in PME (TN-C-S) you lose earth too, leaving EPS socket without earth
@ianandrew7010
@ianandrew7010 Год назад
Cool setup all the customer needs now is a Smart Meter before he can go on Octopus Agile or Go Tariff 🤔
@stjernkvistj3666
@stjernkvistj3666 5 месяцев назад
Why is the dc cables not protected all the way from the rails on the roof down to the inverter in a flex pipe? This installation would fail standars in sweden
@barrietranter7316
@barrietranter7316 Год назад
Hi can you tell me if it's possible to site all the electrical equipment and batterys in the loft, I live in a detached bungalow many thanks 👍
@blow0me
@blow0me 2 года назад
surely in the event of a power failure, part of the point of having a battery system is so you have power ? Not just one external socket you need to plug leads into ? Why are the battery systems/inverters not set up more like a UPS ? And is it a 12v system ? 24 ? other ?
@Soruk42
@Soruk42 2 года назад
The Growatt batteries are likely about 50V. A grid tie inverter will shut down if there is no power detected on the grid. The EPS outlet is a separate output from the inverter which will be switched in when the grid supply is out.
@blow0me
@blow0me 2 года назад
@@Soruk42 All those batteries and you still end up powerless in a power cut....just seems all wrong and a bad design ?
@Soruk42
@Soruk42 2 года назад
@@blow0me I see where you're coming from but it makes the whole system that much more complicated and a higher risk of failure to have some kind of grid monitor that completely isolates the house electrics from the grid in the event of an outage, then rejoins it upon restoration of supply. I have personally never seen such a setup. The system has to shut down in the event of an outage else you risk electrocuting a linesman who believes he is working on a disconnected line when a solar installation has energised it.
@blow0me
@blow0me 2 года назад
@@Soruk42 They way I see it though....it should be just a giant UPS ? so mains typically passes through the inverters, but on mains loss, there is still continuous uninterrupted supply. It does seem they do not work like that though. But yes it would mean the inverters would need to be quite capable, but most seem to be only 4-5kw at most ? which is pretty low, although would see a lot of current of only 12v. If at 48v, it would be easier on the invertors to offer a good 230v AC supply with decent current capacity, but still with caution. And with a UPS, there is no backfeed to the grid. So surely it should be easy ? Just like a UPS ?
@bramcoteelectrical1088
@bramcoteelectrical1088 2 года назад
Makes things complex without a physical.change over switch. Most installs i put in rcd socket as the inverter becomes an IT earthing system ups. so make sure you do earth your grow watt batteries incase of faults and a rod TT setu setup if you do go full change over setup
@digitalfm10
@digitalfm10 3 месяца назад
How did you get the battery cover to fit on with the growatt cables. Mine just simply won’t screw into place. The cables are just too thick.
@Soruk42
@Soruk42 2 года назад
Very nice. I have the same (or very similar) inverter but only 3.6kWh storage. When I win the lottery I would like to seriously extend the storage if that is possible.
@eFIXXENERGY
@eFIXXENERGY 2 года назад
Good luck 🤞
@bramcoteelectrical1088
@bramcoteelectrical1088 2 года назад
Upto 8 batteries...but max i would have is 4 with testing ive done on all my grow watt systems
@MichaelGreenhalgh
@MichaelGreenhalgh 2 года назад
band 1&2 segregation? surge protection? are fire rated clips in the loft needed? I'm not currently doing pv installs but looking at going into it.
@hein_mcleod
@hein_mcleod 2 года назад
If the cable run is less than 10m from panel to inverter then the built in SPD is sufficient. Longer runs need an external SPD at or near the array.
@colingoode3702
@colingoode3702 Год назад
Interesting. I have just ordered a solar battery system & wondered about the location of the inverter & batteries. I definitely don't want them outside the house so I have a choice of in the loft or, making some room in my rather cramped single garage. The loft would be easier in some ways but I've read some reports that the hot / cold temperature cycles in loft spaces are detrimental to inverter & battery reliability. Any thoughts or advice would be appreciated.
@WizardNumberNext
@WizardNumberNext 10 месяцев назад
That is actually truth I have been on repair where inverter reported bad insulation caused by moisture (usually after rain or in morning due to dew). It doesn't happen often, but it does happen. This stops generation till fault is clear. Batteries have another set of problems if installed in loft. Weight is one, (very remote) possibility of chemical sp is another. Electrical equipment in loft would force you to install ionisation smoke detector interlinked with rest of your fire alarm system. If you don't have interlinked fire alarm, then you would have to fit it. That is for most locations of Inverter.
@colingoode3702
@colingoode3702 10 месяцев назад
@@WizardNumberNext 👍In the end I decided to have the inverter, battery, solar diverter & other ancillaries fitted in my garage. The installers were very grateful because it meant they didn't have to carry the 110kg battery up into the loft space & I didn't need any additional fire / smoke detectors. The system is working well but the 3.6kW Hybrid inverter is not really big enough for everything we run at the same time. I now wish I had got a larger inverter & more battery storage. I'm looking at extra batteries & possibly a new inverter.
@user-vr8sq5gi2c
@user-vr8sq5gi2c Год назад
Hi, just wondering, why haven't you fitted protection between the battery and invertor, regs and the growatt installtion guide state a 2 pole MCB must be fitted in case of battery fault. Also, regs and the installation manual also say the invertor must be protected by an RCD but you installed it in the consumer unit before the RCD. I'm confused, can you clarify why you've installed it like you have? Cheers
@tusdardcart
@tusdardcart Год назад
Is the CT measuring import or export? It looks like it's to measure export but to have the arrow pointing at the sun is a new one for me! 😂
@darrenbanton8929
@darrenbanton8929 9 месяцев назад
Great video ! It’s clear and explains a lot!
@afnankhokhar5578
@afnankhokhar5578 7 месяцев назад
One thing I've never understood is; what happens to the electricity generated by solar panels when they're not wired up. Like where does that energy go? And why did the installer not get an electric shock when he touched the live wire coming from the solar panel?
@eFIXXENERGY
@eFIXXENERGY 7 месяцев назад
If not connected energy dissipates in the panels as heat.
@matthewmarks6951
@matthewmarks6951 5 месяцев назад
To get a shock you need to complete a circuit, so if the panel outputs are floating (not connected to the earth), the only way you can complete the circuit is to touch both connections at once. Not a good idea to do it in case there's leakage to earth occurring somewhere - including making sure you know where the end of the other wire is.
@roundoakfarmbutchersshop3649
Nice install - Is the EPS socket earthed and RCD protected inside the inverter? Also where do you get the inverters from? I cant find a UK supplier
@johnsimonson7206
@johnsimonson7206 Год назад
Didn't show how it connects to the DB
@matthewmarks6951
@matthewmarks6951 5 месяцев назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-CRYnracqRjM.html
@Keithdaniels479
@Keithdaniels479 Год назад
Great install however I’ve copied this and connected a zappi charger as part of an upgrade for my EV. How do I identify the battery away from the inverter on the my energy app ?
@ianmoss20102010
@ianmoss20102010 4 месяца назад
nice old meter switch will run backward with the solar
@radiotowers1159
@radiotowers1159 Год назад
Great video, I am considering a very similar system. What is the weight of the inverter and battery as my internal walls are all plaster board. Can the battery sit on the floor , held by a bracket upright ?
@CastleKnight7
@CastleKnight7 Год назад
My garage internal walls are plasterboard. A mounting board was fitted onto a wooden frame which attaches to the plasterboard. The inverter was hung on the mounting board and the battery sits underneath on the concrete floor, though there are mounting brackets to prevent it from tipping over just in case. The 3.6kW inverter weighs 27.5kg and the 9.5kW battery weighs 110kg. Both are GivEnergy.
@radiotowers1159
@radiotowers1159 Год назад
@@CastleKnight7 Thanks at 110 kg its good to know it can sit on the floor.
@CastleKnight7
@CastleKnight7 Год назад
@@radiotowers1159No problem. It’s a neat system and takes up much less space than the small Beko feeezer I have in the garage.
@chrisbirch6557
@chrisbirch6557 Год назад
Shouldn't there be a DC breaker between the battery and inverter? Growatt suggests that there should be?
@EXFElectrician
@EXFElectrician 2 года назад
Very interesting my have to up skill in to PV and batterie storage.
@bramcoteelectrical1088
@bramcoteelectrical1088 2 года назад
Looking to set up training on all solax and grow watt for just that in nottingham working on it as we speak
@cliffkitheka9559
@cliffkitheka9559 Год назад
Very,very good job!
@manofvalor3679
@manofvalor3679 Год назад
@2:50 Is this a typical install method for 2 batteries rather than using specific 2 battery cable set?
@mickmorrison
@mickmorrison Год назад
All that technology and there’s still an old analogue mains meter, I thought they had all been replaced with digital meters.
@Nicolas-qb3yg
@Nicolas-qb3yg Год назад
Analogue would work forever. The smart meters would have to be replace now on then …. Or fault for any reason !
@gbelectricks
@gbelectricks 2 года назад
Great video chaps 😎
@jcf828
@jcf828 Год назад
Hi, are spas not required on the solar strings?
@thoughtful_criticiser
@thoughtful_criticiser Год назад
Forgive the stupid question, it's more than ten years since I did any work at the domestic level. As an electrical engineer I was surprised that only one socket with EPS, I understand the protected circuits. If I was going for this type of installation I would expect, in the case of power failure of the grid, for my home to still operate as normal. Is that possible? Or, do you have to design an off grid installation with a grid backup? I think I need to update my level 3 qualifications, or is there an alternative? Regarding the panels, should they not come with a plastic film that light doesn't penetrate to enable safe installation without having to worry about live wires?
@persona250
@persona250 Год назад
Yes of course you can rig the whole house on backup but if the customer hasn’t paid for that then he’s not going to set up an ATS earth rod etc .
@arnyczful
@arnyczful Год назад
can someone help me there how to install switch that is operated by electric provider and its need to use drm 0 or whatever is it to stop the production if they need to stop it remotely i cant figure out how to connect the pins and cables its inverter mod10ktl3-xh
@GregNow
@GregNow 2 года назад
0:59 I don't know when they will run those cables, but it looks like someone is running hoover on that gas meter! 🤣😉
@crineljurj2084
@crineljurj2084 Год назад
the inverter can be used with lead batteries
@_pikachu_6378
@_pikachu_6378 Год назад
What are the contract sockets and how to wire setup
@solarrover9575
@solarrover9575 Год назад
Where does the earth come from for that eps socket if the pme earth is lost? Should have rod surely??
@matthewmarks6951
@matthewmarks6951 5 месяцев назад
Not shown in the video: there's a pair of wellies and a warning notice hooked on to the socket.
@Kentprepper
@Kentprepper 2 года назад
Any idea why he didn't use a parallel cable kit ? Also if you add a second battery to existing then i read it needs to be checked/balanced with multi meter.. any idea how to balance ??? I want to add a second battery and thought i needed a parallel cable and not sure about balancing :)
@bramcoteelectrical1088
@bramcoteelectrical1088 2 года назад
Stuff like that has been in short supply.. Charge one battery up full using solar or mains...then take out and do same for new battery...then add them both...easy way to do it or just check with therw 10v of each other max...
@Nicolas-qb3yg
@Nicolas-qb3yg Год назад
These batteries are brand new, so balanced in factory. Also note that the battery cables seems to be both the same length to ensure an equal load !
@sundog486
@sundog486 2 года назад
17:14 There is no direction with a CT clamp with regard to a AC current reading.
@bramcoteelectrical1088
@bramcoteelectrical1088 2 года назад
Yes the correct ct direction is critical...
@matthewmarks6951
@matthewmarks6951 5 месяцев назад
I can see why you think that, but the inverter is also looking at the voltage waveform, and if you compare the two (such as by multiplying them together) you will get the opposite result if you turn the CT around.
@OG-dp1kx
@OG-dp1kx Год назад
Are these batteries any good? Went for givenergy but installer is offering these due to delays in givenergy supply
@danielebrahim2336
@danielebrahim2336 Год назад
I've only heard bad things about givenergy, - whereas Growatt is a mid price good choice.
@rogeronslow1498
@rogeronslow1498 Год назад
Do you have regular power cuts or is this to reduce your power bill?
@matthewmarks6951
@matthewmarks6951 5 месяцев назад
Unlike in South Africa, in the UK we don't have regular power cuts.
@TheDrew2022
@TheDrew2022 2 года назад
Curious why they aren't using some sort of dual contact connector? Seem's like a bunch of single contact connectors the potential for mixing them up is greater and if we're dealing with a couple hundred volts per bank, I could see miswiring causing damage and injury. Some systems I've seen here in Canada use Anderson Power Poles which can't be connected backwards once crimped.
@blow0me
@blow0me 2 года назад
battery banks are not operating at hundreds of volts. Pretty sure they are only 12v, although you'd think 48v would make more sense. But potentially they might be handling a lot of current
@TheDrew2022
@TheDrew2022 2 года назад
@@blow0me I was referring to the leads from the solar panels. The measured voltage when he was installing the plugs on the leads in the attic he said the leads were measuring 292 volts DC. Watch around @10:15 his volt meter says 292 and he says 292 minus volts. That's not the 12v you were saying. As for battery banks, it's not uncommon to have voltages higher then 12v. A UPS I recently replaced the batteries on, the nominal voltage per bank was 48v on a 1500w UPS. And older 3000w UPS we pulled from service the battery banks were nominal 192v.
@bramcoteelectrical1088
@bramcoteelectrical1088 2 года назад
48v to 52volt growatt
@TheDrew2022
@TheDrew2022 2 года назад
@@bramcoteelectrical1088 So where did his volt meter get 292 volts from on the solar panels?
@bramcoteelectrical1088
@bramcoteelectrical1088 2 года назад
@@TheDrew2022 the dc voltage from.the array
@danmurphy7338
@danmurphy7338 Год назад
Great video. Where do you run the EPS to and from? Just to the inverter to socket or have you install an ATS? Growatt advised me an ATS is needed and from the consumer unit but I dont see this in your video so was wondering if your set up works without ATS, earth rod, or from consumer unit.
@persona250
@persona250 Год назад
Watch the video . 1 double socket is fed direct from the eps port .
@danmurphy7338
@danmurphy7338 Год назад
@@persona250 that’s not how it’s fed. The feed still needs to come from somewhere via the inverter. Growatt say it requires an ATS and others say they have been able to do it the same way from im the video. However I’m unsure if it requires a seperate CU
@persona250
@persona250 Год назад
@@danmurphy7338 have you watched the video ? . It’s really easy to follow , the eps port is on the inverter , the engineer connects a flex from this port into a double socket .
@danmurphy7338
@danmurphy7338 Год назад
@@persona250 yes I have watched the video. I have also spoken to Growatt who advised this method wouldn’t work without the ATS. I can’t see an ATS. Incase of a powercut the inverter would go into island mode without the ATS even if theres power in the battery unless I have miss understood what Growatt have said. I’m new to solar so excuse the ignorance if I am not making sense.
@persona250
@persona250 Год назад
@@danmurphy7338 you have misunderstood .
@Fritsvrolijk
@Fritsvrolijk Год назад
Whats free energy look a your bil from the instal Enjoy
@arvenjay
@arvenjay 2 года назад
Pardon me for my question. I’m a newbie. I got Growatt sph6000 with 24 lead battery. My question is, does the battery goes with the grid at night? Or the battery serves as a backup power only?
@eFIXXENERGY
@eFIXXENERGY 2 года назад
It can be both depending on how you set up the inverter.
@arvenjay
@arvenjay 2 года назад
@@eFIXXENERGY do you have a video on how? Pls if you have it
@peterconnolly4608
@peterconnolly4608 2 года назад
After power failure what amperage is available from battery /inverter return ,
@bramcoteelectrical1088
@bramcoteelectrical1088 2 года назад
16amp
@bramcoteelectrical1088
@bramcoteelectrical1088 2 года назад
16amp check my istall and eps modes
@neilaaron5733
@neilaaron5733 Год назад
I would have cleaned the brick dust off before installing the kit
@johncockram248
@johncockram248 2 года назад
Well that's shit if there was a power cut I would want the battery to power all the house not just one socket
@eFIXXENERGY
@eFIXXENERGY 2 года назад
You can do that but you are still limited to the power available in the battery - start an electric cooker running to battery won’t last long!
@MatSmithLondon
@MatSmithLondon 2 года назад
Polaritorised?!?!?!!!
@Lordlindef
@Lordlindef 2 года назад
And price was how many 10 of tousens ???
@Lordlindef
@Lordlindef 2 года назад
Too extreme too talk about ore ???
@Bondy1986
@Bondy1986 Год назад
Roughly £15-18k
@arvenjay
@arvenjay 2 года назад
Hi. Can you combine 2 or more EPS in combiner box in Growatt?
@bramcoteelectrical1088
@bramcoteelectrical1088 2 года назад
No
@bramcoteelectrical1088
@bramcoteelectrical1088 2 года назад
No you cant get 2 hybrids to work off one house tried asking and does work as they fight each other in push and pull
@arvenjay
@arvenjay 2 года назад
Thanks for your reply. My contractor made a mistake. He said it is possible.
@bramcoteelectrical1088
@bramcoteelectrical1088 2 года назад
@@arvenjay all have learn buddy. These systems are new tech
@kathrynwhitby9799
@kathrynwhitby9799 2 года назад
i'd be interested to know if there was similar system for battery storage from off-peak electricity?
@eFIXXENERGY
@eFIXXENERGY 2 года назад
You can use this system ( and others similar) to charge from off-peak.
@kathrynwhitby9799
@kathrynwhitby9799 2 года назад
@@eFIXXENERGY fab
@bramcoteelectrical1088
@bramcoteelectrical1088 2 года назад
This system works great for just ess mode storage fitted over 100 so far
@kathrynwhitby9799
@kathrynwhitby9799 2 года назад
@@bramcoteelectrical1088 do tell! ESS mode is not a term i've heard of.
@bramcoteelectrical1088
@bramcoteelectrical1088 2 года назад
@@kathrynwhitby9799 ess stands for energy storage system look us up if you want off peak storage fitting. Lots of different ways and sytems
@Iam-not-as-grumpy-as-Isound
@Iam-not-as-grumpy-as-Isound 9 месяцев назад
The fibre glass and no gloves, oh no!
@user-fs4dv3ir1k
@user-fs4dv3ir1k Год назад
There is a ridiculous amount of problems with this install and its so untidy!
@furstyferret
@furstyferret 2 года назад
Does anyone recognise the brand / model of panels used?
@jakeholman5315
@jakeholman5315 2 года назад
JA Solar 370W - Probably all black
@bramcoteelectrical1088
@bramcoteelectrical1088 2 года назад
JA 385 black frames common as
@ianmoss20102010
@ianmoss20102010 4 месяца назад
there is no need for this battery storage as the solar will make the meter run backwards when its producing excess energy with this old meter without a ratchet
@jamesseddon-zs5fy
@jamesseddon-zs5fy Год назад
No way should you be testing live strings like that in the loft. Mark them up on install and get plugs on them. Much safer 👍
@amitku1486
@amitku1486 2 года назад
And i want to learn from u .. please help me
@amitku1486
@amitku1486 2 года назад
Hi I'm from India i just want to work.with u
@joshcoupe556
@joshcoupe556 Год назад
Just dont plug one end of the string into the panel the its not live, alot safer than his method
@BillsCountrysideAdventures
@BillsCountrysideAdventures 4 месяца назад
Like how this guy says make it look pretty, but doesn't own £100 henry and dust attachment. Getting dust everywhere is not good practice.
@groMMit1981
@groMMit1981 Год назад
So if the mains power goes out, the batteries don't power the home but you can use those two plugs by the batteries? Great for the UK I suppose with very minimal power outages, but no good for South Africa.
@matthewmarks6951
@matthewmarks6951 5 месяцев назад
Absolutely. The difference in South Africa is that you're not allowed to export, are you? Your sunny country was so far behind when it came to solar PV due to politics, but since your "load shedding" has become chronic it seems that it's coming in behind batteries as the primary focus. Affordable batteries are of course a more recent development than affordable PV. I've had PV since 2011 and get paid for what I generate whether I use it or not.
@crineljurj2084
@crineljurj2084 Год назад
?
Далее
EASIEST Off Grid Solar Power System Battery Bank
29:53
How to Choose SOLAR Wisely and Avoid Costly Mistakes
25:40
Аруси Точики ❤️❤️❤️
00:13
Просмотров 233 тыс.
Самое неинтересное видео
00:32
Просмотров 371 тыс.
Mid install of this SolarEdge PV and battery System!
26:33
5 Reasons To Get A (Bigger) Home Battery
22:07
Просмотров 278 тыс.
Аруси Точики ❤️❤️❤️
00:13
Просмотров 233 тыс.