Solar (PV) Disconnects & How To EASILY INSTALL ONE from DIHOOL Electric 

The Juice Box
Подписаться 1,9 тыс.
Просмотров 20 тыс.
50% 1

🔗 Small Disconnect Box (new model): amzn.to/3EosOMh 🔗 TONS of other Boxes and Switches: amzn.to/45URcRl 🔗 The Juice Box Website: the-juice-box.com ⬇️ MORE LINKS BELOW ⬇️
🔗 Multimeter: amzn.to/448HVE9
🔗 Klein USB Multimeter: amzn.to/45q2SvK
🔗 Sound Meter: amzn.to/3YG8QWG
⚡ Welcome to The Juice Box! ⚡
In today's video I bring you along for the complete installation of a solar disconnect or PV disconnect with 100 amp breaker. What is a solar disconnect? When do you need a disconnect? How to install a solar disconnect? All these questions and more will be answered today; in The Juice Box!
🔷 VIDEO CHAPTERS 🔷
0:00 - Intro
🔷 INFO FROM THE MANUFACTURER 🔷
#solarpower #solarenergy #thejuicebox
DISCLAIMER*
This video and description contains affiliate links, which means that if you click on one of the product links, we may receive a small commission at no extra cost to you. As an Amazon Associate I earn from qualifying purchases

Наука

Опубликовано:

 

3 сен 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 39   
@Unknownusername1
@Unknownusername1 2 дня назад
I was about to buy PV disconnect, but I decided on watching a RU-vid first and found you (Subscribing!). Your video reassures my research and installation plans. Going to make my purchase now. Thank you! It would be great if you did videos on extension cables and best practices for getting them inside. I have some of the research, but your studio design and presentation skills help prepare people like me.
@victornwaokoro3887
@victornwaokoro3887 3 месяца назад
You ought to have talked about MCB with Polarity.
@Texacate
@Texacate 6 месяцев назад
The polarity is Improntant because we're dealing with high voltage DC currents. By design, the plasma arc, created when the breaker trips, will be drawn into the extinguishing plates by a permanent magnet. Wire it wrong and the arc is repelled, and may not ever extinguish. This could cause a fire. Very important to get it correct.
@steveferguson1232
@steveferguson1232 10 месяцев назад
Love watching this new channel Sam
@richardzicarelli3193
@richardzicarelli3193 7 месяцев назад
OMG you are all over the place! I mean that in a good way meaning you have multiple RU-vid channels covering many topics. Just subscribed to this one too. Great video!
@paulgreenhalgh4790
@paulgreenhalgh4790 9 месяцев назад
Should ferrules have been used on the stripped wires instead of just twisting them before inserting into the breaker?
@michaeldezelar6264
@michaeldezelar6264 2 месяца назад
No
@justanotherperson2761
@justanotherperson2761 6 месяцев назад
I watched your video on the Dihool Solar (PV) Disconnects. I am interested in a Dihool smart mcb to control the current used in my shed. The Dihool product drew me to your channel. Anyway, your video was very clear, concise, and effective. I will watch for your future videos. Thanks.
@jacquesdutron9954
@jacquesdutron9954 10 месяцев назад
Thx a lot for all your efforts. You're absolutely good at what you do. Having said that, let me put in my 2 cents. When you're using the EG4 18K-PV (Hybrid inverter) you do not need a combiner box. Also, many are moving away from it and using instead an isolator. Thx
@dustincashwell31
@dustincashwell31 Месяц назад
Thank you sir. Subscription earned
@cautiouscommenter
@cautiouscommenter 8 месяцев назад
The hardcore reason to connect the positive from the panels to the positive on the breaker is about how the breaker does its job. Internally it has an electromagnet that is used to pull the contact away to open the connection when the breaker senses over-current. If connected in reverse, the over-current will cause this magnet to PUSH the connectors together causing the breaker to cook itself.
@WiSeNhEiMeR-1369
@WiSeNhEiMeR-1369 9 месяцев назад
HOWdy T-J-B, ... Thanks for taking us along ... by the way = those weather / water TIGHT fittings are referred to as: "GLANDS" ... suggestion: when installing / securing STRANDED-WIRE in a screw-down FITTING (like your circuit-breaker) you might want to explore the use of FERRULES ... ... ferrules bind all of your STRANDED Wires together in a bunch to allow for a better contact &
@TheWoodHaven
@TheWoodHaven 6 месяцев назад
Didn't even know these existed. I might have installed one at the cabin. Right now I just have an in-wall SAE socket.
@hing983
@hing983 4 месяца назад
Hi I see u connect red cable on the right side of breaker I have Lange dxpool 47 32 A break should connect red on right side or left or does not matter either way
@shmayazuggot8558
@shmayazuggot8558 7 месяцев назад
I’d advise using ferrules and double insulating the connectors. Postive and negative must be in the correctly poled connectors or Arcing will probably occur.
@robert4027
@robert4027 9 месяцев назад
That's cool I like it. 100 v. 50 amp is what i need
@johnle231
@johnle231 9 месяцев назад
Becareful
@johnnybarnes6780
@johnnybarnes6780 4 месяца назад
Is this just an on/off switch or is it also a breaker and do I still need to use inline fuses with it?
@davejagodzinski7817
@davejagodzinski7817 6 месяцев назад
DC breaker, does it have a polarity ??? Could be important. ???🔥
@JasonBedient
@JasonBedient 10 месяцев назад
So you could do a dedicated battery disconnect box just like that? Battery disconnects are not an easy solution to find online. Most search finds stuff for marine or rv life rather than residential. I need to have a disconnect for 20KWH eg4-LL battery backup. Would something like this work?
@TheWoodHaven
@TheWoodHaven 6 месяцев назад
Never got notivied of this or the next video. Subbed and Belled. Not sure what's going on.
@irfanwaseh
@irfanwaseh 9 месяцев назад
Like ur videos
@homezero
@homezero 10 месяцев назад
If you place a straight 1 x 2 on the bottom you should be able to semi-permanent mount the bottom portion of your breaker box under the French cleat. this keeps the box from raising off the cleat. I hope I was clear on what I said here.
@lakorai2
@lakorai2 8 месяцев назад
You should use a UL listed DC breaker from Westinghouse
@MitchOfCanada
@MitchOfCanada 3 месяца назад
8 Gauge wire on a 100 amp breaker??
@heffe2001
@heffe2001 10 месяцев назад
Keep the french cleat, but put a piece of wood on the lower screws that keeps it pulled down. That'll keep the cleat engauged, but be easily removable.
@heffe2001
@heffe2001 10 месяцев назад
In other words, put a regular piece (not beveled) at the bottom, using the bottom screw holes on the box, that touches the flat bottom part of the cleat board, applying pressure on the top cleat. Still easy to remove (just take that board out), but won't mess up your wall either.
@JR-xw5dk
@JR-xw5dk 9 месяцев назад
I was thinking about a board above cut to fit so it cannot move up. Or a board cut at an angle and use it as a wedge to hold it down.
@Patzilla09
@Patzilla09 9 месяцев назад
Why not just use a light switch? Maybe a stupid question but if it is a small PV system it should be fine. Right?
@hu5116
@hu5116 9 месяцев назад
Other than the polarity signs for avoiding shorting mistakes, is there any difference with an AC breaker? (I can use a sharpie to add +/-)
@cautiouscommenter
@cautiouscommenter 8 месяцев назад
The differences are monumental. AC cycles give the breaker a safe way to break the current at 0v. DC doesn't have that cycle, the current is constant. So, DC breakers need a mechanism to stop the electrical arc that forms when it tries to break the connection. Some people call it an arc-extinguisher.
@topeye4202
@topeye4202 6 месяцев назад
Read my comment...WARNING...
@bartoski-ag
@bartoski-ag 4 месяца назад
2:31 haha
@littlet6220
@littlet6220 10 месяцев назад
Reason it's marked negative and positive. The reasoning is when the switch is on or off it engages the off position on the negative side first before the positive side when you turn it on it does the positive and then adds the negative within the switch so there's no spark. It's like a car battery you always remove the negative 1st.
@topeye4202
@topeye4202 6 месяцев назад
WARNING: If this polarized breakers are connected with the source (solar panels) comming from bellow, the plus pole must be connected on the side where on top the minus symbol is printed on the breaker. There are magnets inside to push the spark into the extinguishing chamber, otherwise the spark is pushed in opposit direction into the mechanism and the breaker catch on fire within seconds! The current flow must go from + to - and of course the + stay a + even he leaves the breaker throught the - terminal. If coming with the source from above as shown in video, the + must be connected on the side where the + symbol is.
@tjmooney4181
@tjmooney4181 3 дня назад
Polarity marks should match the source side
@topeye4202
@topeye4202 3 дня назад
@@tjmooney4181 If there are only polarity marks on the top, but you come with source from below, then plus goes into the minus side.
@woodlandparadise6002
@woodlandparadise6002 10 месяцев назад
A small block of wood below the cleat and screwed to box, But breakers really are not disconnects they are meant for protection of the wiring
@willarddevoe5893
@willarddevoe5893 9 месяцев назад
I don't need that thing. I run off 12 volts and everything is smooth. Connecting your solar to the utilities isn't very bright.
Далее
DC Isolator - Wiring a Solar PV Disconnect Switch
13:18
КТО ЭТО БЫЛ?
25:31
Просмотров 1,1 млн
How to select and install a solar disconnect switch
12:01
Polarity DC Breakers Explained
10:01
Просмотров 5 тыс.
No Room In Electrical Panel - Quick Fix
7:21
Просмотров 1,2 млн
SOLAR ISOLATOR WIRING (for a DIY camper van)
6:35
Просмотров 58 тыс.
How to ensure safe and effective solar grounding
15:56
PV Combinerbox - step by step DIY tutorial
29:01
Просмотров 5 тыс.
PA-RISC рабочая станция HP Visualize
41:27