Тёмный

SOLVING the Winnebago FLX Truma Varioheat W 27 H Error code ⚠️ 

Living With Rob
Подписаться 3,1 тыс.
Просмотров 1,1 тыс.
50% 1

In today's Winnebago Wednesday video we will talk about the Varioheat Furnace install by Truma and the W 27 H! error code fix I am trying.⚠️
Here's a Link to the Passive Register Vent cover in the video. amzn.to/49HM4Cs
Purchase One of a Kind Photographic Prints from Us now at livingwithrob.com/prints
💚www.amazon.com/shop/livingwit...
❤️Visit Rob and Joelle online at livingwithrob.com ❤️
📝Read Rob's Blog livingwithrob.com/blog 📝
😎Find Rob and Joelle on Social Media😎
Facebook / livingwithrobert
Instagram instagram/livingwithrobert
X / livingwithrob
📫Connect with Rob and Joelle for any business inquiries through our sites contact page 📫
✍livingwithrob.com/contact ✍
Check out Rob's 2nd Channel on RU-vid @robsreelamerica
Please take special note. This is NOT sponsored. However, we may make a small commission from links from which you may make a purchase.
About: The Winnebago Micro Minnie FLX model campers come with the Truma Varioheat furnace, a highly efficient model with which you can heat your RV. However, the way that Winnebago has chosen to install these furnaces leave a lot lacking.
First, they provide horrible heat dispersement. Second they get very hot at times which will then trigger the W 27 H warning. This warning means the heater is running too hot so it enters into a cool off phase.
In this video, I am going to attempt a fix for the problem by installing a passive air flow vent under the shower wall through the access panel. It's my hope in doing so it will provide ample air flow into the furnace from the RV interior allowing it to get more air hence allowing it to run cooler.
I hope you find this Winnebago Wednesday video helpful if you own a Winnebago FLX model RV trailer.
#fulltimerv #rvliving #winnebagomicrominnie #winnebagoflx #livingwithrob #robertanthony #rvlife #landscapephotography #professionalphotography #robandjoelle #robandjoelleanthony

Опубликовано:

 

5 мар 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 14   
@livingwithrob
@livingwithrob 5 месяцев назад
Since we began using heat in our 2108DS FLX Winnebago, we've been getting the W 27 H! advisory telling us the unit is running hot and has entered into a cool down mode. While Truma says it's alright, but not ideal, I decided to deploy this fix. At this time, we have called for heat a few times in the early morning and since installing the passive vent, we aren't getting any error. Time will tell, but maybe this quick inexpensive attempt made the difference. I guess when/if we get back to super frigid cold we shall see if it still is resolved. ⚠****Update 03-23-2024****⚠ We did in fact fun into colder weather. The W 27 H! Advisory error did return. So, this did not fix the problem. HOWEVER, I have in fact noticed there is a pull of air through the passive vent toward the Truma Vario-heat while it's running. This tells me that while this unit does in fact go into cool down mode still, it is pulling return air out of the rig while heating and is circulating the air better. Still would do this mod based on better air distribution.
@don0fthedead
@don0fthedead 5 месяцев назад
Sound logic and good work, Rob. My wife and I have a 2108 FLX model. Shortly after our purchase of the model in early '22, I had replaced the below shower cover with a vent with thumb screws for easy on/off because we had issues with the shower leaking due to poor seals. Complete happenstance that it probably helped us avert the same error code. This probably isn't an issue for you since you avoid hot areas, but we've run into the issue of the fridge not cooling as well as it should. We don't use the trailer as often as we'd like, but when we do, it's typically in hotter months (and we're in the south). It may take several days for the fridge/freezer to finally reach what I'd call acceptable temperatures. I get the feeling it's due to a similar issue (as far as I can tell, there are no vents to let the heat exchange occur with the fridge on our FLX model). I've of course checked all the usual suspects (e.g., fan issues, venting within the freezer/fridge being blocked, etc.). Interested to hear if you've got any cents on this.
@livingwithrob
@livingwithrob 5 месяцев назад
Thanks for watching. The only issue we have had with our fridge is that it has dead spots and we end up freezing various items when it's set to run cold enough that the milk won't spoil. When I ran the 12V wiring up the wall to fish it to the compartment where my Starlink modifications to 12v are housed, we had to take the fridge out. In doing so, I had considered how that space provides very little air flow for the back end of the fridge, meaning, in my view, that compressor will get hotter than it should. Perhaps this is the reason for premature failure of these 12v style fridges about which I've read. I do think figuring out a way in which to get some fresh air back there would be well advised and in fact, I think I am going to consider how to do so. I am open to suggestions from everyone and would of course produce a video on the project! 🙂
@tombodet7918
@tombodet7918 2 месяца назад
Common sense approach and solution. Crazy that the factory didn't do that, especially when there is an inspection cover available that could be so easily replaced with a register. Good job.
@livingwithrob
@livingwithrob 2 месяца назад
Thanks Tom. After all the work, I do still get the error message, however it's less so now. I will say, though, the unit does draw air through this vent now. I can fell it pulling air in through the vent when the Vario Heat is on. It will pull and hold a tissue against it when running, so...in the end...I maintain...still a poor design, but I get better air flow now.
@user-jn8lb8tf2y
@user-jn8lb8tf2y 5 месяцев назад
I added a circular vent below the refrigerator, beside the propane heater to help with air flow. Hot air from the furnace is basically in the same place like your heater below refrigerator. The furnace also has duct work going into and below floor to help heat that area with the holding tanks. Have tank heating pads as well. Overall I’m very happy with my 1708FB unit. Looking forward to seeing your solar set up. I am currently working on adding additional solar to my trailer.
@user-jn8lb8tf2y
@user-jn8lb8tf2y 5 месяцев назад
Air flow is very important for many reasons. Dry air to help keep humidity down😊
@livingwithrob
@livingwithrob 5 месяцев назад
Yes, the non FLX models do a MUCH better job with heat and dispersing air flow. In particular I do not like how these FLX units have only 1 heat output and nothing going below floor to underbelly.
@user-jn8lb8tf2y
@user-jn8lb8tf2y 5 месяцев назад
@@livingwithrob 👍I didn’t know that. This is another design element that has been revealed between the Winnebago line of Micro Minnies since I purchased mine in 2021. Regardless of which type of heat or size of the trailer, I would think the basic concept for heat and airflow would be integrated into the design to get optimum performance. I enjoy your watching your videos 😊
@livingwithrob
@livingwithrob 5 месяцев назад
@@user-jn8lb8tf2y this is one major difference, yes. Thank you. We appreciate you watching.
@tombodet7918
@tombodet7918 2 месяца назад
Might be a good place to mount a 12v computer style fan to draw the hot air out?
@byronargueta1026
@byronargueta1026 3 месяца назад
Love it!! Subscribed .
@livingwithrob
@livingwithrob 3 месяца назад
Thank you.
Далее
Air Conditioning isn't free... but we're close.
25:45
🎸РОК-СТРИМ без ФАНЕРЫ🤘
3:12:10
Просмотров 1,4 млн
Almost EVERYONE is Wasting Money on Dash Cams.
17:32
Installing Truma air conditioning into our caravan
13:37
Installing your own Mitsubishi AC Unit - SRK series
42:24
Truma Varioheat Installation on Jayco Caravan
6:45
Просмотров 8 тыс.
Truma Varioheat eco AU
3:07
Просмотров 1,3 тыс.
Truma VarioHeat Gas Air Heater 2021