In this lecture, you will learn how to calculate the dead load of staircase and apply it on the mid-landing beams in the form of UDL (in KN/m).
DL of staircase consists of:
1) DL of waist slab
2) DL of steps
3) Floor Finish (in KN/m2)
Watch the complete lecture to see the detailed calculations for our live project. Like, Share and Subscribe the channel to stay updated!

Опубликовано:

 

24 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 18   
@pragatheshwarananbarasan3641
@pragatheshwarananbarasan3641 2 года назад
In calculating steps load.. by multiplying area with unit load ..we will be getting .675 kn/m
@aeena2863
@aeena2863 6 месяцев назад
Best video ever see related to stairs load ❤
@simplystructural8424
@simplystructural8424 6 месяцев назад
Thanks 🙏🏻
@luwembaabbey1020
@luwembaabbey1020 2 года назад
Sir the self weight of the step will be kN/m
@peoplespowerhellyeah8619
@peoplespowerhellyeah8619 Год назад
Steps load's unit is not kn/m2, it would be kn/m. As area is m2 and unit wt unit is kn/m3
@SreyaReyansh
@SreyaReyansh 6 месяцев назад
Since the stair load is divided equally between the mid landing beam and beam at starting point of stair at floor level, as you said, we need to add the load 18.12 to the floor beam also. But that is not assigned. Please clarify…
@sanjaya6178
@sanjaya6178 Месяц назад
Did you get the answer
@DanuwatMaoleethong
@DanuwatMaoleethong 27 дней назад
Yes Agree He only assigned to the mid landing beam, The floor beam al so need to assign the same load as mid landing beam too
@meitei97
@meitei97 14 дней назад
Won’t we apply load on the opposite slab also
@souviksaha6408
@souviksaha6408 2 года назад
Sir, I have a question, on mid landing beam the the udl which you have applied should be double. because on mid landing beam two flights join.
@simplystructural8424
@simplystructural8424 2 года назад
No. This is because Only half of the beam length is loaded with UDL from one flight.
@souviksaha6408
@souviksaha6408 2 года назад
@@simplystructural8424 okay sir thank you
@vasubhadania
@vasubhadania 8 месяцев назад
Can you please make a video for an open well stair case loading....
@ojalessharonkatha.9831
@ojalessharonkatha.9831 Год назад
Where did you get 2kn/m² on FF?
@ExplainerDido
@ExplainerDido Год назад
Sir please clear the doubt Staircase ka half load other side k beam pe bhi transfer hona chahiye to mid landing k sath hum dusre side k beam pe bhi ye load apply karege?
@suryavardhansinghrathore4421
@suryavardhansinghrathore4421 7 месяцев назад
Same doubt?
@bjg9801
@bjg9801 2 года назад
no need to model the staircase?
@shredder807
@shredder807 2 года назад
Shouldn't the load be applied on the other beam where the main landings will be resting on? You applied the load on the mid landing beams that are towards the outside of the building but not on the beams that are towards the inside of the building.
Далее
повтори звуки животного 😱
00:52
staircase 1
15:19
Просмотров 2,6 млн
Building Design with stair cases in Staad Pro Software
21:08