Welcome to our RU-vid channel, where we dive into the fascinating world of gas turbines! In today's video, we're taking you through the intricate process of starting up a gas turbine from the ground up. below are few steps, however it may change from machine to machine based on their types.
Once you ensure all Safety systems are acknowledged.
All sub support utilities are online and ready (Compressed Air, Water for Cooling or NOx Reduction, Power Supplies).
Press the Start button.
Hydraulic Pumps turns the Hydraulic Motor to bring Gas Turbine up to speed. After 66% Engine Speed the Turbine Bleed Valve closes equalizing all Stages of the Compressor and Exhaust Stages and the Turbine can sustain itself...if not it will go into Stall and Fail start-up.
Before reaching 100% Turbine Engine Speed the Generator Field is Flashed to energize the Electrical Field.
The Sprague clutch is over ridden and the Turbine reaches 100% Engine Speed.
Once the Turbine reaches 100% the Heat Recovery diverters slowly adjust open to direct Heat to the Boiler Section. Once the Boiler Pressure increases past 25% Load the Main Generator Breaker can be Closed and provide Power to your Facility.
It is now safe to establish Water Injection to the Gas Turbine for NOx Reduction because it will not Flameout as long as the Turbine is running at 100% Engine Speed.
You should now be burning Fuel to sustain the Gas Turbine which is providing Electrical Power. And building Steam Pressure to sustain the Steam Turbine for either Electrical Generation, Building Heating and Cooling or Compressor Operation.
Gas turbines are the heart of many industries, from aviation to power generation, and understanding how they come to life is crucial. Our expert host will walk you through each step, breaking down the complexities into easily digestible segments, making this topic accessible for all levels of knowledge.
for base load and peak load power plants

Опубликовано:

 

6 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 42   
@gustavomarcelo7250
@gustavomarcelo7250 11 месяцев назад
Sir. How to join the weekend session?
@powerplantguru007
@powerplantguru007 11 месяцев назад
Hello Mr. Gustavo Can you please write to us (dgna.creator@gmail.com)-what you want to discuss, so that we keep engaged related experts. We will reply to your email with details.
@gustavomarcelo7250
@gustavomarcelo7250 11 месяцев назад
@@powerplantguru007 How does the shutting down process works, does it follow any curve and sequences?
@powerplantguru007
@powerplantguru007 11 месяцев назад
It follows a curve, there are two types of shutdown normal shutdown and emergency shutdown, and both follow different curves
@gustavomarcelo7250
@gustavomarcelo7250 11 месяцев назад
@@powerplantguru007 possible to make a wonderful video of it?
@powerplantguru007
@powerplantguru007 11 месяцев назад
Sure 😊
@shababahmed5017
@shababahmed5017 11 месяцев назад
Please describe on a video, about LCI and Excitation system, how they work.
@powerplantguru007
@powerplantguru007 11 месяцев назад
Sure 😊
@450vinod
@450vinod 6 месяцев назад
Nice sir doing good to the upcoming engineers
@powerplantguru007
@powerplantguru007 6 месяцев назад
Thank you for watching my videos
@abdusaidelshalwe2211
@abdusaidelshalwe2211 4 месяца назад
at this speed temp dcreasing because all blow off valves closed tha combustion air increases and air cooling of combuation basket quantity inceased also
@promiseokoi2936
@promiseokoi2936 11 месяцев назад
Your explanations are the best. Can you explain this while showing us on a HMI screen, it would help a lot, thank you.
@powerplantguru007
@powerplantguru007 11 месяцев назад
Thank you for watching my videos, please subscribe to the channel. Using HMI screen may violate organisation data security policies.
@promiseokoi2936
@promiseokoi2936 11 месяцев назад
Okay, already subscribed. How can I join the weekend doubt clearing session?@@powerplantguru007
@powerplantguru007
@powerplantguru007 11 месяцев назад
Please email us at dgna.creator@gmail.com With mentioning What you want to understand. We will revert back
@kedardixit8622
@kedardixit8622 8 месяцев назад
I was not knowing the significance of the deep in the speed after purge. Thabls for reasoning
@ramyakrishna7662
@ramyakrishna7662 11 месяцев назад
Good job bro,, and can you do video on especially on 9H gas turbine startup (gas & Liquid fuel) discuss DLN 2.6+
@powerplantguru007
@powerplantguru007 11 месяцев назад
Thanks for watching my videos, please subscribe 😊
@abhishekkumarupadhyay1385
@abhishekkumarupadhyay1385 Месяц назад
What is coast down time?
@powerplantguru007
@powerplantguru007 Месяц назад
Coating down time is the taken to reach barring/ratcheting operation from normal running condition of machine
@user-el4zx4ys6o
@user-el4zx4ys6o 10 месяцев назад
Dear sir Please make video for gas turbine starting motor how is it working
@powerplantguru007
@powerplantguru007 9 месяцев назад
Hello Thank you for watching my videos. Sure i will create that video
@user-el4zx4ys6o
@user-el4zx4ys6o 10 месяцев назад
Dear sir, Please make video for gas turbine starting motor and hydraulic converter how it is working
@powerplantguru007
@powerplantguru007 9 месяцев назад
Hello Dharma Thank you for watching my videos. Sure we will make those videos
@178airil
@178airil 9 месяцев назад
Hi thank you for the explanation. I am kind of wonder, when the turbine is running at no load speed, let say 6000 rpm, how the load (for example process compressor / generator) can be introduced since the load at this moment is at standstill? Will the load increases the speed from 0 rpm to 6000 rpm (assuming gear ratio of 1) instantenously?
@powerplantguru007
@powerplantguru007 9 месяцев назад
Thank you for watching my videos. Please watch my video on droop .
@powerplantguru007
@powerplantguru007 9 месяцев назад
While we introduce the load, the initial load is low and machine control system allows speed reduction upto 4-5% of full speed. Although the actual variation is very less, that is the beauty of the GT control system. To understand this please read on droop and watch my video on droop.
@mohammedalzahrani5071
@mohammedalzahrani5071 5 месяцев назад
Sir you didn’t explain when the starter motor is disengaged? Is it disengaged immediately after the coast down is completed or when exactly?
@powerplantguru007
@powerplantguru007 4 месяца назад
Hello what I could understand from your question is 1. There is no role of starting the motor while coasting down, machine RPM reduces on its own, and one its speed reaches near to barring RPM then barring motor cuts in and maintains the machine on barring speed. 2. Role cracking motor is startup: when the machine is in acceleration mode and the machine RPM increases above 60% the rated speed, then the cranking motor disengages and the turbine is on self-sustaining speed.
@kedardixit8622
@kedardixit8622 8 месяцев назад
Is their questior on the gas turbine functining so that we i can think and learning. Also any paid training classes?
@powerplantguru007
@powerplantguru007 8 месяцев назад
Hello Kedar Thanks for watching our videos. We have sessions on Sunday, you can join those sessions. You need to tell us what is the questions you want to cover so that we can group other viewers & relevant expert in the session. Please provide your email id or send us a mail at dgna.creator@gmail.com
@450vinod
@450vinod 8 месяцев назад
Nice
@powerplantguru007
@powerplantguru007 8 месяцев назад
Thank you for watching my videos please subscribe
@velayuthammurugan2769
@velayuthammurugan2769 11 месяцев назад
Please explain exhaust speard alarm & trip
@powerplantguru007
@powerplantguru007 11 месяцев назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-4rklhRA6hmk.html
@powerplantguru007
@powerplantguru007 11 месяцев назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-YQKKmVvswns.html
@powerplantguru007
@powerplantguru007 11 месяцев назад
Hello, Thank you for watching my videos. I am sharing link for my videos on the topic you requested. Please watch and let me know if there are any questions
@Thunder_317
@Thunder_317 8 месяцев назад
Maybe the temperature does not increase because 88Tk starting
@powerplantguru007
@powerplantguru007 8 месяцев назад
I didn't understand your point, please explain what you want to convey
@Thunder_317
@Thunder_317 8 месяцев назад
@@powerplantguru007 at 2800 rpm the 88TK Turbine exhaust frame cooling blower start.
Далее
Pre Start up checks in Gas Turbine, Gas Turbine startup
19:00
How to get Spongebob El Primo FOR FREE!
01:36
Просмотров 15 млн
The Problem with Wind Energy
16:47
Просмотров 2,4 млн
The Clever Engineering Of Piston Rings
23:12
Просмотров 680 тыс.
GAS TURBINES
16:45
Просмотров 11 тыс.
GE Gas turbine components and operation
59:15
Просмотров 7 тыс.
The Big Engine - the GE LM2500
10:51
Просмотров 308 тыс.
Automated Hydrogen Generator
17:21
Просмотров 1,4 млн
Why Thorium will be a Game-Changer in Energy
32:00
Просмотров 231 тыс.