Тёмный

Step by Step Adding a Pressure Regulating Filter to An Irrigation Valve and Replacing a Valve 

Waterwise Community Center
Подписаться 2,6 тыс.
Просмотров 54 тыс.
50% 1

Опубликовано:

 

1 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 34   
@bizboomer
@bizboomer 2 месяца назад
What is the irrigation gray pipe? Is that the same thing as PVC EMT pipe? Thanks.
@CBWCD
@CBWCD 2 месяца назад
The gray pipe going to and from the valves are irrigation risers (also know as nipples), similar to schedule 80 irrigation pipe, but not technically schedule 80. We like using the risers because they come threaded, so at each connection into the valve there is one fewer glued joint, which is one fewer place to potentially leak. Schedule 80 pipe works well for this purpose as well. Both of these gray irrigation pipes are considered to be UV stable, meaning they will not degrade in sunlight and become weak and brittle like white PVC will, which is technically only for use in applications where it is buried / not exposed to sunlight. Schedule 80 might only be available from speciality landscape supply stores, but 3/4" risers / nipples of varying lengths are usually available at both landscape supply stores and big box hardware stores. THIS IS VERY DIFFERENT THAN PVC EMT pipe!! EMT pipe is meant to protect electrical wires and is MUCH THINNER than irrigation pipe which must stand up to being under pressure and deal with pressure fluctuations without leaking. Electrical conduit pipe should never be used for conveying water.
@AndyChengHD
@AndyChengHD Год назад
Amazingly clear, thank you so much for a thorough and easy to follow guide
@machiavellian18
@machiavellian18 3 года назад
Very well done and clear. Easy to understand and see.
@frankflores4083
@frankflores4083 4 месяца назад
I installed mine. Doesn’t seem to regulate. What’s the white button for?
@crazyjesse11
@crazyjesse11 Год назад
Hi I just put bubblers in the front of my house and I got one vavle watering the backyard and the front but when I go to turn one the vavle the front hardly has any water pressure and suggestions
@aldoroman3931
@aldoroman3931 2 месяца назад
Good video. I do have a question, though. Why not use a union anywhere so that if a valve replacement is ever required, it would make it easier?
@CBWCD
@CBWCD 2 месяца назад
Great comment. You are absolutely correct, it would make future replacements easier. When installing a manifold from scratch, I'd definitely use a union. For this one, we were trying to keep the already long video as simple as possible. Also, for those just getting into plumbing, installing a union into a retrofit creates multiple other potential spots for leaks if all is not aligned and tightened correctly. If we do another valve installation or swap video in the future we will add that step! Thanks for they input!
@ranaparker4825
@ranaparker4825 Год назад
Thank you for the detailed video. Now I want to try this myself. One question about at 11:30 mark: why do you need to make two cuts, particularly I’m not understanding why the cut on the horizontal pipe is needed? Couldn’t you connect the new gray riser to the existing vertical pvc connection? Thanks!
@CBWCD
@CBWCD Год назад
Hi! You could do that, however, since white PVC is not UV stable, and over time will degrade and become brittle when exposed to sunlight, this is the perfect chance to connect the pressure regulating filter, then attach a grey PVC nipple (also called a riser). The grey pipe is considered "UV stable" and will not weaken in the sun like white PVC.
@terrireyes295
@terrireyes295 Год назад
Your video is outstanding. I now feel like I can take this project on myself. I have a similar antisiphon valve set up. Will I need to use backflow preventers at each sprinkler riser on the zone or does the antisiphon valve for the zone prevent backflow? This is something that seldom is addressed in all of the great info out there about converting to a drip system.
@CBWCD
@CBWCD Год назад
Hello. If installed at the right height, the antiphon valve will prevent back flow. If for some reason, you cannot install as designed with the height of the valve at least 6" above the highest sprinkler when in operation, a back flow preventer somewhere else in the zone could be an option.
@brianhankins9992
@brianhankins9992 2 года назад
Great video. What would you have done if there were any leaks? That is my current problem.
@wilkinson949
@wilkinson949 3 года назад
Thank you for posting this very informative video. I know what I'm doing this weekend.
@SteveWebb777
@SteveWebb777 3 года назад
Excellent video. Thanks.
@alirE2904
@alirE2904 9 месяцев назад
Great, now I will do mine.
@ranchoelbamboo4068
@ranchoelbamboo4068 3 месяца назад
Thank you
@AlexMurilloh23
@AlexMurilloh23 Год назад
His Gluing technique gives me anxiety.
@CBWCD
@CBWCD Год назад
Hi Alex. We'd love to know more details. While the video does not show wiping up the pipe to make a "pretty" looking finish, we believe the glueing to be perfectly functional. However, there is always more to learn. Might you be willing to take a moment to let us know how you would have done it differently and what about it makes you anxious? Thanks!
@randomvideos3674
@randomvideos3674 2 года назад
You could see it running?
@joec632
@joec632 6 месяцев назад
Very informative . A little Mr. Rogers-esque but still very good info. thank you.
@williamnewman8850
@williamnewman8850 Год назад
Would have been nice if you specify what area you are referring too. This would be unacceptable in area which has freezing temperatures. No mention of each valve requiring check valve to avoid siphoning of water back in to domestic water. Not sure why one antisiphon valve would’ be acceptable for. Entire system ? Also no mention of how all these zones are connected Thur the manifold which is buried underground. Should mention how all these zones are connected The valves are surrounded via a mulch no explanation as to why a mulch is necessary? Great to have a lot detail but. Not giving an over explanation of the basics is also important If you are going to hand tighten all threaded connections would be nice to say why you would not use wrench to do this. Everyone would use a pipe wrench hand tightened seems like you are forgetting without again no explanation. Too much discussion of minor details . Also not mentioning that glue and primer are highly toxic and gac respirator and safety glass and gloves are recommended
@CBWCD
@CBWCD Год назад
Hello William, I'm sorry this video was confusing to you. It was created to provide answers to the most common questions we get when people in our area are transitioning to drip irrigation. Your comments are well taken, and will be used to improve our videos in the future. The anti-siphon valves have the built-in check function which is all that is needed in our area to prevent siphoning issues. Much of this confusion, I believe, is due to regional differences, so thank you. I will add a note to the description that this is intended for areas that do not freeze and where anti-siphon valves are used. We are based in low-elevation southern California, where lines do not freeze, and the vast majority of residential properties do not have back flow preventers for the entire property, so each valve must be an "anti-siphon valve" which must be installed elevated as shown here, and not buried in a valve box. Electrical remains exposed as well (and is very low voltage), so as long as proper outdoor wire nuts are used, as demonstrated, this is proper. We recommend hand tightening threaded connections to begin with because we find that far more homeowners will over tighten and damage connections, cause leaks, and ruin parts if we start with recommending using tools. Filters are not required on all lines. In our area, which gets water supplied though a city or special district water retailer, sprinkler zones generally do not need filters, so this video is specifically created to support people moving from standard sprinkler systems, which would not have a filter in most cases, over to a drip system, which would require a filter like this.
@bradmills01
@bradmills01 3 года назад
This is exactly what I was looking for!
@paradigmnnf
@paradigmnnf 3 года назад
Great video with a detailed description! Thank you
@williamnewman8850
@williamnewman8850 Год назад
Really lacked explanation as to the how system is set up no over where lines run Very confusing! No explanation as why things are done. Filter ? None of other lines have a filters? Also all valves exposed including electrical. I was always told valves need to be in valve boxes. Also the valves no protection for freezing. Also hand tightening lines? Just away to make sure they will leak. Waiting several minutes to look for leaks will not make sure of no leaks need to tighten properly!
@CBWCD
@CBWCD Год назад
Hi William. Sorry this was confusing to you. We have received lots of other good feedback from people fining this video helpful. Much of this confusion, I believe, is due to regional differences, so thank you. I will add a note to the description that this is intended for areas that do not freeze and where anti-siphon valves are used. We are based in low-elevation southern California, where lines do not freeze, and the vast majority of residential properties do not have back flow preventers for the entire property, so each valve must be an "anti-siphon valve" which must be installed elevated as shown here, and not buried in a valve box. Electrical remains exposed as well (and is very low voltage), so as long as proper outdoor wire nuts are used, as demonstrated, this is proper. We recommend hand tightening threaded connections to begin with because we find that far more homeowners will over tighten and damage connections, cause leaks, and ruin parts if we start with recommending using tools. Filters are not required on all lines. In our area, which gets water supplied though a city or special district water retailer, sprinkler zones generally do not need filters, so this video is specifically created to support people moving from standard sprinkler systems, which would not have a filter in most cases, over to a drip system, which would require a filter like this.
@jimrylander9143
@jimrylander9143 Год назад
It’s actually 6” above the highest sprinkler when on. PVB is 12”. Take a backflow prevention class.
@CBWCD
@CBWCD Год назад
Thank you for the comment / correction. I absolutely misspoke when recording the video, and will note the error in the description and eventually re-edit to correct. I appreciate you taking the time to comment!
Далее
Replacing A Lawn Sprinkler Manifold
18:17
Просмотров 452 тыс.
Лиса🦊 УЖЕ НА ВСЕХ ПЛОЩАДКАХ!
00:24
How to Video: Converting Sprinklers to Drip
7:08
Просмотров 191 тыс.
Hunter IIF Training:  Valve and Wiring Installation
10:53
Irrigation Pressure Regulators
18:09
Просмотров 55 тыс.
Anti-Siphon vs Inline Valves
3:08
Просмотров 199 тыс.
Replacing A Irrigation Sprinkler Valve
24:07
Просмотров 52 тыс.