Basis of Bid purposes only.

Опубликовано:

 

10 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 13   
@jovanpajic3554
@jovanpajic3554 9 лет назад
It is important to let the first flow of water out because of muddy water. This gadget tests both static and dynamic pressure, seems very practical.
@danielgaytan7074
@danielgaytan7074 6 лет назад
Make sure you stand on the opposite side of that 5 inch cap, just in case it's loose while your opening the hydrant cause that pressure will shoot that cap out and that'll be the end of your knee.
@SXViperFanatic
@SXViperFanatic 11 лет назад
It would only have to be per NFPA 13 if the flow test data was being used to design a sprinkler system. I should actually retract the statement above after watching the video a 2nd time. We use a pito tube to measure discharge pressure, which I didn't see and lead me to question the test. On second view, a pito tube is not necessary since the apparatus has a built in gauge. I would like to know where to get one, those are nice. Must have a calculated chart for pito pressure to GPM.
@idahohuntfish79
@idahohuntfish79 11 лет назад
why does it have to be per nfpa 13? I run a lot of fire flows that have nothing to do with sprinkler installs and design. if my test indicates adequate flow and dependent on the building type/size/design/use/materials/etc, i'll have my engineer issue an ability to provide fire flow and no sprinklers will be required.
@SXViperFanatic
@SXViperFanatic 11 лет назад
I don't understand how you can perform a true flow test per NFPA 13 using this equipment? Where was this purchased from?
@AteebGamingg
@AteebGamingg 6 лет назад
eBay
@SMSexe
@SMSexe 11 лет назад
that is alot of flow
@bgiesecke
@bgiesecke 11 лет назад
a pitot of 55 should be about 1250 gpm
@wlyounce375
@wlyounce375 7 лет назад
Could be using a different Discharge Coefficient for the hydrant. If using a Coefficient of 0.85, average between the smooth transition and a sharp transition, the results for 55 psi would be approx. 1,175 gpm. Not sure how that gauge is reading though...guys are saying the gauge converts into flow on the readout....hmm....
@firesafetysecuritycommunit7028
@firesafetysecuritycommunit7028 10 лет назад
nice :)
@danielflores-xk2iy
@danielflores-xk2iy 2 года назад
residual pressure = pitot pressure?
@jmr6041
@jmr6041 4 месяца назад
No
@amarsongshar7130
@amarsongshar7130 3 года назад
Yt
Далее
Hydrant Flow Testing
6:04
Просмотров 61 тыс.
Самый БОЛЬШОЙ iPhone в МИРЕ!
00:52
Новый уровень твоей сосиски
00:33
Hydrant Inspection and Flushing
6:00
Просмотров 42 тыс.
Hydrant Flow Testing
5:45
Просмотров 39 тыс.
Laying 8" C900 waterline, closeup of the crew tasks
6:08
Fire Flow Test
3:27
Просмотров 19 тыс.
Fire Flow Testing
3:22
Просмотров 1 тыс.
Hydrant Testing
6:27
Просмотров 12 тыс.
How to Pressure Test a Fire Hydrant
4:50
Просмотров 17 тыс.