In this video, we tackle the issue of a blown switching IC and bad resistors on the PCB of Sharp and Gree air conditioners. We diagnose the problem step-by-step using a multimeter in diode mode to check the resistors and diodes, including the short-circuited D126 diode. Learn how high voltage and faulty capacitors can cause voltage fluctuations that damage your PCB. Watch as we replace critical components like resistors, capacitors, and diodes to restore power to the indoor and outdoor units. Whether you have a Sharp or Gree AC, this video will help you troubleshoot and fix common PCB issues.
💡 Support Us On Patreon 👉 bit.ly/3vMga6S
💡Subscribe to The Channel 👉 bit.ly/3vNT7s3
Social Links
💡Facebook 👉 / forevertech3
💡Instagram 👉 / forever_tech11
💡Twitter 👉 / forevertech3
#ac #pcb #repair #diode #resistor #capacitor #voltage #sharp #gree #ic #outdoorunit #multimeter #troubleshooting #fix #acrepair #pcbrepair #acpcb #electronics #airconditioner

Опубликовано:

 

27 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 4   
@rolanddejesus8685
@rolanddejesus8685 6 дней назад
thank you very much sir.
@dariuszgo9685
@dariuszgo9685 5 дней назад
Super tnx😊
@forevertechenglish
@forevertechenglish 5 дней назад
Thanks
@edwardlacson2592
@edwardlacson2592 7 дней назад
Capasistor explodead in lafftop brandead too ic c in volt
Далее
История Hamster Kombat ⚡️ Hamster Academy
04:14
Avaz Oxun - Yangisidan bor
14:29
Просмотров 388 тыс.
Новый вид животных Supertype
00:59
Просмотров 138 тыс.
Can Dangerous Saw Blades Cut Wood?
25:34
Просмотров 10 тыс.
They fooled so many: Fake cache chips!
28:58
Просмотров 21 тыс.
How 3 Phase Power works: why 3 phases?
14:41
Просмотров 1,1 млн
История Hamster Kombat ⚡️ Hamster Academy
04:14