Switching NB HMI Screens Using PLC 

Omron Automation - Americas
Подписаться 17 тыс.
Просмотров 51 тыс.
50% 1

Omron Quick Tip - How to use PLC Control to switch screens from a PLC

Наука

Опубликовано:

 

4 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 15   
@TanapongPonghanat
@TanapongPonghanat 5 лет назад
Nice training vdo clip ,Thank you
@atifbrema4971
@atifbrema4971 6 лет назад
I want to now how to make alarms on HMI cx desinger and how to apply the alarms with cx program...... please
@HITCHHIKERS1
@HITCHHIKERS1 11 месяцев назад
Hi im using Sysmac PLC how can i address it to change screen?thanks
@JoaoHenrique-qj3ke
@JoaoHenrique-qj3ke 6 лет назад
In my program, It only shows either "Switch Screens" or "Change screen (ignoring screen 0)". There's no "Change Window", and neither of those other 2 are working, and I've done everything acording to the video
@MYNGUYEN-kn3tf
@MYNGUYEN-kn3tf 5 лет назад
help me, hmi kinco gl100e conection plc s7 -1200 , on display only show button but isn't show lamp, and message on hmi is " (1) PLC response error," i hope you help me, thanks.
@PardeepLabVIEW
@PardeepLabVIEW 4 года назад
🔥🔥🔥🔥thanks a lot sir🔥🔥🔥🔥🔥
@OmronAutomationAmericas
@OmronAutomationAmericas 3 года назад
All the best
@PardeepLabVIEW
@PardeepLabVIEW 3 года назад
@@OmronAutomationAmericas 🥰❣️
@user-je8he7ox6p
@user-je8he7ox6p 7 лет назад
How to set the change screen command word to W50? I cannot find it in manual?
@OmronAutomationAmericas
@OmronAutomationAmericas 7 лет назад
Please look at the manual NB-Series Start-up guide V109-E1 Page 4-25 Here is a link to the manual: www.fa.omron.com.cn/data_pdf/mnu/v109-e1-08_nb3q_nb5q_nb7w_nb10w.pdf?id=3110
@rfc4
@rfc4 7 лет назад
That link goes to a blank webpage.
@ParmodKumar-jp6gz
@ParmodKumar-jp6gz 4 года назад
Safety passive key show on HMI no function working
@abdelwahebgharbi9256
@abdelwahebgharbi9256 7 лет назад
I have downloaded a program into the PLC, downloaded a program in the HMI terminal, and connected my PLC to the HMI via a custom made RS232 cable. When I turn them on, the correct screens appear on the HMI terminal, but no data is coming through from the PLC. After a few seconds, a pop-up appears saying "[2]PLC No Response 00-00-1". Does anyone know the meaning of this message, or what I might be doing wrong or missing out? CPU used: CP1L-M60DT1-D (with a CP1W-CIF01 serial adapter) HMI terminal used: NB3Q-TW00B Details for the RS232 cable: NB pin 2 (SD) to CP1L (CP1W-CIF01) pin 3 (RD) NB pin 3 (RD) to CP1L (CP1W-CIF01) pin 2 (SD) NB pin 9 (SG) to CP1L (CP1W-CIF01) pin 9 (SG) CP1W-CIF01 Bridge between pin 4 (RS) and pin 5 (CS)
@Jankalo2
@Jankalo2 7 лет назад
Just check the node of the PLC , and HMI, or check there is a connection between them.
@cssdatalabs7867
@cssdatalabs7867 6 лет назад
You must select "Host Link" in PLC settings. And be sure that plc com port settings (7E1, 7E2, 8E1 etc.) and HMI com port settings are the same.
Далее
🎸РОК-СТРИМ без ФАНЕРЫ🤘
3:12:10
Просмотров 1,4 млн
E5 Temperature Controller to NB HMI Setup
12:24
Просмотров 14 тыс.
Omron CP1H PLC Numbering Systems and Addressing
17:17
ALARM VIEW NB DESIGNER OMRON
4:37
Просмотров 41 тыс.
Setup NJ PLC with NB HMI From Omron
17:06
Просмотров 1,5 тыс.
ALARM AND EVENT  CONFIGURATION NB Designer
11:03
Просмотров 21 тыс.
NB-Designer User Graphics
2:26
Просмотров 35 тыс.
Копия iPhone с WildBerries
1:00
Просмотров 8 млн