Test voltage generated by a servo motor, commonly called Ke constant

Опубликовано:

 

11 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 2   
@dhakshanamoorthys1643
@dhakshanamoorthys1643 Месяц назад
M701 AC servo drive is tripped , The alarm is I/O OVERLOAD is showing on display, How to solve this issue , Please guide me .
@_mectel
@_mectel Месяц назад
Hi, The I/O Overload trip indicates that the total current drawn from 24 V user supply or from the digital output has exceeded the limit. A trip is initiated if one or more of the following conditions: • Maximum output current from one digital output is 100 mA. • The combined maximum output current from outputs 1 and 2 is 100 mA • The combined maximum output current from output 3 and +24 V output is 100 mA Recommended actions: • Check total loads on digital outputs • Check control wiring is correct • Check output wiring is undamaged