Training Minutes: Mike Ciampo discusses the many uses of the pressurized water can, a versatile fireground tool, and how it fits into the overall operational mission of the truck company.
These videos are for training demonstration purposes only. When you perform these techniques at emergency scenes and evolutions, be sure to wear full PPE and adhere to your agency's procedures and policies.
#4664323062001

Опубликовано:

 

25 июн 2020

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 41   
@Fredengle
@Fredengle 2 года назад
any way for those that were wondering I was able to make indirect contact with Mike and here is what he said in individual units in the FDNY, they will often fill their cans with a little less water. This enables the can to have more air in it, which can assist a unit while awaiting the engine's hose line. It won't add that more pressure because the can is normally filled to 100psi and the gauge will read overcharged when going past that pressure. The reason for less water and more air, allows us more time inside the apartment or dwelling containing the fire, while the engine is making a long hose stretch to the fire area. As for the exact amount of water, units play it by ear and don't measure the water exactly. Most units may put 2 1/4 gallons in it and leave the 1/4 out, some may just run 2 gallons and leave the half out. We have also been adding some foam to all of our cans so that the mixture adheres to the burning materials better. With today's new plastics, we've seen flare ups when hit with water. So we're hoping the foam saturates the material or cuts off some of the oxygen and smothers the burning plastics. As for measuring, our books say we use 10 ounces of foam in the cans.
@owensweetland342
@owensweetland342 Год назад
This guy's great. Real good stuff.
@Hearthman1159
@Hearthman1159 3 года назад
You didn't mention adding a dash of dish soap as a wetting agent. Do you foresee any problems with this? It's been a standard for years for small fires such as the cigarette in the couch where surface tension beads the water up. Same for small roadside fires. Good stuff Mike. 343 buddy.
@Fredengle
@Fredengle 2 года назад
What I see if you ask me is that dish soap conducts even more than foam so there is no possibility you can use it on an electrical fire
@coltonwolfe4412
@coltonwolfe4412 2 года назад
Probably don't want to know but I'm on the can
@rhoonah5849
@rhoonah5849 Год назад
Let us know how it all came out.
@jlt7793
@jlt7793 3 года назад
Nice tips! We also add about 10cc’s of fire aid to our cans.
@Fredengle
@Fredengle 2 года назад
Hi JLt77 my question to you is I see that in this link its titled water extinguisher on class b I guess that would explain why he is using a misting finger ? ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-91zsCgQQLoo.html ideas please thank you
@jlt7793
@jlt7793 2 года назад
@@Fredengle I don’t see how less water and more air would be beneficial. Not to overstate the obvious but water puts fires out. More pressure may help a bit with reach but you would then need less water since there’s only so much room inside. We use 2 1/2 gallon extinguishers. Water goes in first, usually just to the bottom of the sleeve to leave room for air. Then add in some fire aid. If the fire aid goes in before the water then you’re getting bubbles and it’s a lot messier. Then pressurize to 100psi and you’re good to go. And the ring should only be hand tightened. Hope that helps.
@Fredengle
@Fredengle 2 года назад
heres a question for you would you take a chance with a can that was not currently hydro tested?
@jlt7793
@jlt7793 2 года назад
@@Fredengle no. Water cans aren’t pressurized enough to need hydro testing. They’re only hand tightened.
@Fredengle
@Fredengle 2 года назад
@@jlt7793 Hi JL thank you for your response then you say you dont think a water can needs to be hydro tested so in your opinion than the fact that it may be a requirement would mean they have probably done that intentionally to insure that a refill technnican will make money by requiring the performance of an uncessary test? do you agree than?
@Blazefork
@Blazefork 3 года назад
A1 for a chimney fire...steam from the bottom!
Далее
Multi-Car Pileup in a Tunnel
8:59
Просмотров 1,7 тыс.
All About Water Cans
19:36
Просмотров 31 тыс.
Does size matter? BEACH EDITION
00:32
Просмотров 7 млн
НАМ ВРАЛИ О ПИРАТАХ
52:52
Просмотров 1,8 млн
The Punch Technique
6:29
Просмотров 122 тыс.
Ladder Tips
7:58
Просмотров 112 тыс.
Ground Ladder Tips
10:37
Просмотров 323 тыс.
Drop Bar Forcible Entry " The Irons"
7:21
Просмотров 1,7 млн
Vertical Ventilation - Light Weight Truss (LACoFD)
5:47
Search with the Water Can
7:46
Просмотров 24 тыс.
ALL NEW Halligan Bar!
15:28
Просмотров 17 тыс.
Tips for Single-Firefighter Forcible Entry
3:34
Просмотров 68 тыс.
Does size matter? BEACH EDITION
00:32
Просмотров 7 млн