After many more tests and measurements, I have come to the conclusion that I have to upgrade the inverter to one with a proper N to PE link. I read you comments on the Tesla charging video and looked at some options. The Victron path seems to be the best at the moment as it integrates with my existing gear.
I also cannot recommend these solar-charge-inverters-hybrid-solutions enough! They are great devices and ideal for beginners as they have all necessary components already included. Hook up your solar and battery, program the settings and you're ready to go.
Please subscribe and join me on my journey of the Off-Grid Garage!
For more information, please check out my website with links to all materials, devices and products: off-grid-garag...
EVE LF280 LiFePO4 cells 3.2V/280Ah: off-grid-garag...
Solar, Controllers, Inverters and accessories: off-grid-garag...
Batteries, chargers and accessories: off-grid-garag...
Cables, inverters and electronics: off-grid-garag...
Tools, analysers and testers: off-grid-garag...
DISCLAIMER
By watching the video, you agree:
All electrical work must be carried out as per your local laws, rules and regulations. Installations and setups shown in my videos are for test and demonstration purposes only and may not satisfy regulatory requirements. Installation are temporary, for the above purpose and for making these videos. Most electrical work is not for DIY purpose and must be conducted by a trained and qualified person. Please always check your local regulations!
Any liability for conducting your own work, in particular, any consequential damages arising therefrom, shall be excluded.

Опубликовано:

 

16 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 153   
@itsdouetthierry
@itsdouetthierry 2 года назад
The progress you have made when looking at these "older" videos (only 1+ more years now) is incredible. Such a good self learner you are! Bravo
@OffGridGarageAustralia
@OffGridGarageAustralia 2 года назад
Thank you Thierry. I recently had a look at some older videos as well and could not believe how I actually started. What an incredible journey and I'm so glad I can share this all her on the channel. Could not have done it without all of you!
@JeremyAkersInAustin
@JeremyAkersInAustin 3 года назад
The comparison in temperature between the MPPT and inverter is not entirely valid: The MPPT uses it's metal case as a heat sink while the inverter has fans to eject and remove the heat. Try blocking off the fans of the inverter and *then* see how hot it gets. :) Remember that the heat from the MPPT causes the metal case to heat up, while the inverter is ejecting it's heat via fans by blowing the heat out. That's why checking the temperature of the inverter won't predict how hot it'll make your cabinet: It's fans are moving the heat from inside the inverter to the air outside the inverter. From a BTU perspective the inverter is creating way more heat: It's just pushing that heat out rather than letting it build up and cause a temperature increase. Block off those vents and then see what happens. When you mount that MPPT to your metal cabinet that metal cabinet itself will become part of the heat sink for the MPPT, which means it'll shed it's heat directly to the outside via the metal walls of your cabinet. Where-as the inverter is blowing that heat into the interior of the metal enclosure via it's fans which will trap that hot air inside. My motorhome's basement is way bigger than that metal cabinet you have, and they seriously heat it up. A lot. Easily exceeding 40 C and I've had it get as high at 50 C. I would definitely keep the inverter outside the cabinet.
@colinbeckitt9495
@colinbeckitt9495 3 года назад
All too true - to get a reasonable constant output on hot days I had to stop using the small builtin charger on my Multiplus II 48/3k as the extra heat even from only 2000W of PVin pulled the constant output capability to only 1700W on hot days (~40C ambient in metal shed on 36C day).
@jimmysquires5093
@jimmysquires5093 3 года назад
I know it was a hard decision to purchase another inverter, but you made the right choice. Having phandom voltages floating around is just asking for trouble. I think Victron is the best equipment worldwide and they have great support. Even understand English!! I have a 5KW Victron charger/Inverter.
@PeterMilanovski
@PeterMilanovski 3 года назад
5kw! You sir are wealthy LoL...
@jimmysquires5093
@jimmysquires5093 3 года назад
@@PeterMilanovski I have not started yet due some medical problems, but I believe that the system will allow you to program how you want to run it. Grid is attached along with you other sources of power. Then you program it to use battery power as your main source. Solar will charge when available, but when the batteries get low, it will start using grid with no transfer switch. The system will charge your batteries and keep your needs going. Very Smart.
@PeterMilanovski
@PeterMilanovski 3 года назад
@@jimmysquires5093 bloody health problems! I'm not sure if I know exactly what you mean but I have my own health problems, been suffering with anxiety for the last three years, I can do anything but this stops me dead! I and everyone else that I know would understand if it was something visible like a leg or arm missing but this crap is invisible and all that everyone else see's is me being happy like nothing is wrong but it's just me doing whatever I can to keep my sanity... I'm okay so far but I just want it to end! So that I can get busy and start doing everything that has been neglected around the house 🏡. I was just trying to make lite of your equipment! You have what almost everyone else wants but can't because they aren't cheap! As my dad always said, don't ask for what's good, but ask for what's expensive LoL... Well that used to be true rule of thumb for everything but today we have to be a little bit cautious... But definitely can't go wrong with victron! They have a good reputation and more companies need to follow this example! Redback is a great Australian brand and are known for quality products but recently saw them trying to sell one of those cheap Chinese pwm charge controllers re branded as their own for 10 times the price! Mate! I'm Aussie, I'm not stupid...
@peterrock2838
@peterrock2838 3 года назад
New Victron inverter? That means another video is coming... Good stuff!
@OffGridGarageAustralia
@OffGridGarageAustralia 3 года назад
Yeah, at least one more is coming :)
@colinbeckitt9495
@colinbeckitt9495 3 года назад
@@OffGridGarageAustralia great decision to get a Pheonix. Victrons run HOT on constant even mediocre loads (2000W or more). I think they suit cooler climates, so no builtin charger may lower overall temps to get you up to the magic 2200-2500W constant output @35C (summer) for Tesla charging. Good luck Andy!
@budmartin3344
@budmartin3344 3 года назад
So you bought the good stuff, glad to hear that. You may want to keep the other inverter for emergency back up or for future project.
@OffGridGarageAustralia
@OffGridGarageAustralia 3 года назад
Yeah, I can even hook up both at the same time and use the Victron only for the vehicle.
@andreiapostolache3487
@andreiapostolache3487 3 года назад
@@OffGridGarageAustralia i think victron for Tesla and other for garage is the BEST u Will see the 3kw is les thean u think u Will ned more
@daviddibley663
@daviddibley663 3 года назад
You will be very happy with the new Victron as I have one it is the best thing.
@geraldgrogan
@geraldgrogan 3 года назад
Which model did you get from Victron?
@jasonbroom7147
@jasonbroom7147 3 года назад
Input and output fans on the electrical cabinet would be a very smart idea.
@w3bb0y
@w3bb0y 3 года назад
Solar engineering RU-vid channel has a great video on making this
@mrzed6597
@mrzed6597 3 года назад
You could bought an MPP Solar 5kW inverter for that price. And you could DC couple them with the Victron MPPT. So Victron charges the battery and the MPP Solar discharges it. Also extra MPPT in it for a new solar string ... for new solar panels. The cabinet will be to small. Yep it will heat up like an oven. But you can drill 2 hole in the side and put 2 fans there (1th blows in, 2nd blows out). To protect the inside from bugs use mosquito net (folded, or 2-3 layer). There are some very strong mosquito nets that can withstand the constant hot airflow. Cheap solution.
@OffGridGarageAustralia
@OffGridGarageAustralia 3 года назад
Yes, as I said in the video. I want to be flexible. Later, down the track I'm probably switching to an MPP 5kW or 8kW but for now, this is far better for me and everyone else to learn and learn and...
@BrazzaB1
@BrazzaB1 3 года назад
🤣 Bit the nail! Mixing your metaphors there! Good that you bit the bullet and ordered the Victron inverter. We will be biting our nails until you bring out the video 👍
@OffGridGarageAustralia
@OffGridGarageAustralia 3 года назад
I knew it sounded wrong 😊
@BrazzaB1
@BrazzaB1 3 года назад
@@OffGridGarageAustralia 😁 Keep up the videos! Will be great to see the Victron hooked up!
@cdkipp
@cdkipp 3 года назад
Love the Victron. I am in the process of rearranging my system with two Magnum inverters. On the sides with vents they need six inch clearance and three inch on the other sides. If you are going to put the voctron in that box you are going to need to cut a vent in the side and probably the top. Ideally you would also have an intake and output fans. I know it doesn’t feel good to have layout plans change but I needed up changing all of my plans because of that exact issue. Even if the inverter doesn’t burn out it does reduce efficiency.
@georgedemean2228
@georgedemean2228 3 года назад
Yes, the more you deviate from the ideal 25C temp the more incementaly worse the efficiency goes...not to mention components degradation.
@OffGridGarageAustralia
@OffGridGarageAustralia 3 года назад
Good feedback. I'm prepared for everything as I constantly changing my plan.
@walterweese2527
@walterweese2527 3 года назад
don't forget the spare place (aprox10cm) around the inverter ! so place the inverter outside the cabinet ! May be on the cabinetdoor.
@jmaus2k
@jmaus2k 3 года назад
Ground wire needs to be 4awg if exposed. If protected(strapped to or inside conduit) it can be much smaller. But you also should have weeb washers between panels and rails and on lugs that ground to the rail. Sometimes the code goes a little crazy here, but for high voltage systems I can see how that would be better.
@dash8brj
@dash8brj 3 года назад
Wow! big upgrade! well done mate. The victron gear is top notch. I have the same charge controller as you, the older model but same capacity 48V inverter, the smart shunt, and 12V 1000W victron. I'm building a 12V test system before I go the whole hog and put together a 48V system in a rack cabinet. If you want a monitoring station, set up a raspberry pi and make your own monitoring system. Saves buying the victron GX units, or the $300 screen.
@OffGridGarageAustralia
@OffGridGarageAustralia 3 года назад
I looked into the raspberry pi situation. it's another project for another channel... I just haven't got enough time for all of that. I probably just buy a GX down the track and sign up for VRM.
@Dirt-Diggler
@Dirt-Diggler 3 года назад
Hopefully the airflow over the fins will cool the charge controler some when it's upright and on a nice conducing metal surface ?
@defjamsgreen
@defjamsgreen 3 года назад
Might can have a big screen caged inverter to keep the insects out as long as no wires bon’t make contact to the screen but it might still catch dust .If installed in cabinet,make sure there’s a strong fan to draw in fresh air and expell the hot inverter out the cabinet .May the solar be with you .
@OffGridGarageAustralia
@OffGridGarageAustralia 3 года назад
If I put fans in the cabinet, I will have the same dust problem just inside. Yeah, filters... see where this all leads to...
@howardadams4072
@howardadams4072 3 года назад
The Victron MPPT charge controller would run cooler if mounted on the wall so the air can flow up across the heat sink and away. Putting all your goodies in a air tight box when ambient temp is already 35 degrees C is not a good idea.
@henvan8737
@henvan8737 3 года назад
With time you will realize mounting the inverter inside another box with out additional fans is a bad idea.
@millzee60
@millzee60 3 года назад
Almost certainly he will need forced air ventilation for the enclosure. Fortunately the Victron supports the connection of an external temperature controlled fan.
@james10739
@james10739 3 года назад
You can try playing with some small resistors like 1/4 watt or something Since there should not be any current flowing through it but I don't know how high resistance you can get away with but still of anything happen it would blow the resistor out I guess you could also just use a like 1 amp fuse or less I have never looked for any fuses that low or lower
@GehirnfaschingDD
@GehirnfaschingDD 3 года назад
For grounding use one size less then the normal cables. In Most cases that’s ok. So if your solar array works with 6mm2 ... 4mm2 should be fine. Make sure your new victron device will have enough space around itself ... it dont needs exactly 10cm ! I install these units in much tighter spaces and everything works good but keep this place ventilated with some temperature-controlled fans. That’s easy to do for you.
@PeterMilanovski
@PeterMilanovski 3 года назад
Those all in one thing's, you really need to look closely at what all the components inside are! There's many different models available and they all offer something different. How do I know? I have one sitting on my bench which blew up, apparently they don't like having the battery disconnected while the solar panels are connected and providing power! The one that I have is the 12V battery version which also needs 12V solar panels, it can accept 24V panels but the charge controller module is PWM and it doesn't make use of the higher input voltage! The inverter on mine is only 800W which was plenty when I got it to run a file server in the garage but I have since upgraded to a blade server which used to run a hospital here in Melbourne and the inverter just doesn't have the capacity to support it. Also I should mention that the PWM Charge controller module is really slow to respond especially during changing weather conditions, clouds passing overhead cause it to ramp down while it thinks about what it wants to do, then when it finally decided to ramp up, another cloud comes over and we are back to thinking about it!!! It's really annoying! I have since switched over to cheap eBay $10Au MPPT charge Controllers which are rated for 100W for each 12V battery bank so for a 48V string I'm using 4 of them, one each for each 12v bank, that's a total of 400W, they can be paralleled for more current but they are incredibly fast to react! Even without direct sunlight, as soon as it lights up first thing in the morning, they are already begining to work till the last bit of light late in the afternoon! Seriously impressive performance! I can't speak for all of the other all in one models but I wouldn't recommend my one! As you mentioned it can switch from solar to battery to grid AC input which can also Charge the battery with the built in battery charger! There's also a connection to activate a standby generator as well! But for me, I don't want to use the grid or a generator either, the idea of it is great but it's slow, oh and if you introduce an extra load on the battery, like a 12v light for example, the solar charging stops so it can think about what just happened and the same thing happens when you turn off the light... Really annoying 😲... It's fan's sound like a F11 fighter jet is hiding in my garage to.. I hope that this helps 😊
@henvan8737
@henvan8737 3 года назад
Most of of the MPP solar inverters have a synchronized transfer switch, so clocks, computers are not affected if a switch back to grid mains occurs. They are a good product.
@PeterMilanovski
@PeterMilanovski 3 года назад
Do you have one?
@henvan8737
@henvan8737 3 года назад
@@PeterMilanovski Yes a MPP PIP 5048GK. And 5kw of solar panels. It interfaces with a number of Lithium battery suppliers including Pylontech model US3000. I have 3 of these battery packs and have been running as an Off Grid inverter for everything in my house except washer dryer and AirCon, Since june 2020 in Melbourne and have not had to go back to Grid for power. I'm doing what Andy is doing and will be charging an EV as well.
@PeterMilanovski
@PeterMilanovski 3 года назад
@@henvan8737 have you ever watched it to see how it behaves as clouds pass overhead? I don't remember the model of mine but it's the 12v 800w inverter version! It was the cheapest at the time when purchased but now I see that more powerful models are available for the same price I paid for mine. The issue I have found with mine is that it tends to do a lot of thinking about what it wants to do when either clouds pass overhead or if any extra load is placed on the battery for example a 12v light! It seems to be able to sense that something has been connected to the battery and stop's charging to work out what it wants to do about it... It also does the same thing when the extra load is disconnected! So basically if you wanted to also power something else directly off the battery like a 12v water pump to feed tank water to the toilet, it just can't be done with my one! A standalone charge controller doesn't suffer from this problem! I wanted to convert all the lights in my Melbourne house to 12v DC and get it directly from the battery and save the inverter for the thing's that need 240v AC but it's not going to happen with my setup! I'm charging my Lifepo4 Batteries with eBay MPPT charge Controllers which are just PCB boards and they are, so far, doing an amazing job 👍, now I want to get a separate inverter with at least 3kw output to drive the fridge. I have to look into an electric stove and an electric water heater for their power consumption figures to make sure that I get the right inverter or inverters to cover everything... If anything, the electric hot water boiler can always be converted to low voltage as there are various heater elements available for them. As for the air-conditioning, I recently learned that 24v aircon compressors are available from the US and can be used to convert normal house type air-conditioning units... Litterely convert the whole house to Electric! Without the need for a grid tie connection! If you are planning on charging a car, you might need another 1.5kw of panels on top of what you already have, unless you already have plenty of spare energy with what you have! The batteries that I'm using are actually intended for use in a UPS so they are those SLA 7Ah type battery cases but have Lifepo4 Batteries inside instead, they have a BMS inside them so they are well protected, they are super light weight, easy to connect and cheap to purchase when I need more capacity, in a 48v series string, 4 of them are a lot less money than 4 of much larger capacity batteries! They only hold 8Ah but I can afford to purchase 4 at a time every two weeks, and with multiple smaller batteries, they share the current when charging or discharging and that extends their lifespan, I'm at a point where I can't fully discharge them, a few more string's and I will only be able to get them to 50% discharge... They should last a very long time! That's the way to go with batteries...
@danfitzpatrick4112
@danfitzpatrick4112 3 года назад
I am setting up 2 of the MPP 6548 inverters myself. That version is good for 120v each at 6500 watts and 48v DC. I ordered 2 because I am needing 240v. They were 1145 US dollars each shipped in 4 days here. (They also have the neutral bond on the output side)
@PeterMilanovski
@PeterMilanovski 3 года назад
Is the charge controller MPPT or the PWM type on your one?
@danfitzpatrick4112
@danfitzpatrick4112 3 года назад
@@PeterMilanovski They are MPPT. My setup will be off grid, but the inverters will transfer and use the grid as needed (This can be set up in the parameters) Batteries/Solar/Grid.
@PeterMilanovski
@PeterMilanovski 3 года назад
@@danfitzpatrick4112 nice 👍 I have the 12v DC version which has the 800W inverter. I got it almost 3 years ago but I have this issue with it not liking it when I put another 12v load on the battery! I have a water pump that feed's tank water to the toilet and it operates automatically via a built in pressure switch in the pump, every time I flush the toilet, the solar charger stops charging to have a think about what just happened to the battery, then eventually starts to ramp up the charge again, and it does the same thing again when the pump stop's... Meanwhile the sun is shining! And it's not doing anything! I find this annoying! I'm sure that they have good intentions behind why it does this but I, for the life of me can't think why? I hope that this has been sorted out in the newer versions, they are pretty good and I wouldn't mind getting a new and more powerful than the 800W which I have outgrown now! But if I can't use the battery directly for other things like lights and pumps, then I'm just going to have to use something else instead... I have yet to speak to someone who has one installed and working! All that it would take to test is to connect a load, even a light bulb directly to the battery while it's being charged from solar and see if the fan's stop spinning! The wattage for solar input on the display screen should also show that the wattage has dropped out, it waits for 30 seconds to a minute and then starts ramping up again... Who knows? Yours might not do it! Mines probably just an early version?
@scantrain5007
@scantrain5007 3 года назад
Moin Andy, congratulation for your new converter. I think you bought the "Mercedes". High price but - all what I read about Victron - very good quality. Can top it only with the Systems from Mr. Piepenbrink. However: In Australia you get much more "from the Roof" as in Germany possible. So I think you paid your price, but in the end of the day it's not wasted.
@DavidLouthan
@DavidLouthan 3 года назад
Another 2 inches of snow here. I'm thinking I need to visit Andy in sunny Australia to stay charged! So here i am warmer already! I didn't think you'd take the plung for Victron price but way to go am sure it'll be great. Still waiting for my cells to arrive from China.. then gonna go for the victron charge controller and smart shunt. I got the 4s model of bms you are using not sure if it will be as good as it is built a bit different but same app thingy. Great day man,, haha in the pool WOW
@SteDenig
@SteDenig 3 года назад
your folding ruler is from Mühlheim an der Ruhr. Are you from Germany? Greetings from NRW ;-) Great channel and I really enjoy your project!
@lornebonnell2007
@lornebonnell2007 3 года назад
All great info, what model Victron inverter did you choose?
@OffGridGarageAustralia
@OffGridGarageAustralia 3 года назад
The Victron Phoenix Smart Inverter 48V/3000VA
@DerKanal
@DerKanal 3 года назад
👍🏻 Greetings from Germany
@OffGridGarageAustralia
@OffGridGarageAustralia 3 года назад
Hello there!
@KeigoMoriyama
@KeigoMoriyama 3 года назад
Usually top part needs at least 20cm space to help dissipate Heath. See if you can add a fan or make a hole on top of the enclosure then
@defjamsgreen
@defjamsgreen 3 года назад
The bigger the inverter , the more the heat it produces . might not can keep it inclosed . Best may be installed outside the cabinet to disperse more or most of the heat without overheating .
@OffGridGarageAustralia
@OffGridGarageAustralia 3 года назад
I'm worries about the dust and insects starting a family in there...
@randylenart9674
@randylenart9674 3 года назад
They will love ya for the new house hehe 🤓👍🇺🇸
@crankydavesmylfs4787
@crankydavesmylfs4787 3 года назад
Off-Grid Garage I wouldn’t worry about it Andy. I’ve got mine set up in a small lean to on the side of the garden shed. 1.8m x 2.2m with the north and east sides open. I’ve only had problems with ants in the Colour Controller box Remember Victron has a marine background so their gear is pretty good.
@crankydavesmylfs4787
@crankydavesmylfs4787 3 года назад
Urs Odermatt Maybe. Or they could just go to a cosy house where they also have food. Unless you hermetically seal the cabinet and all cable penetrations you aren’t going to keep anything out.
@crankydavesmylfs4787
@crankydavesmylfs4787 3 года назад
Urs Odermatt It’s catch 22 really. If you have it out in the open insects and reptiles can get in. But also if you have it in an enclosure you may make it more appealing for them to stay. My Multiplus II only has an IP22 rating. So less than finger size and dripping water. But so far so good after more than a year. And nearly 4 years for the Taiwanese all in one I had before that. Which was still going strong when I upgraded it for the Victron. I don’t think you can win either way.
@willrobertson826
@willrobertson826 3 года назад
Victron equipment is good stuff
@jamess1787
@jamess1787 3 года назад
Really happy to see him buy this gear. Much better than that rubbish on the market. Here I am, who can't even afford solar, let alone an inverter: being a keyboard warrior!
@colinbeckitt9495
@colinbeckitt9495 3 года назад
@@jamess1787 OMG - that's like saying you'd buy a Porshe 911Turbo to tow your 2ton 30ft caravan coz you heard they are good cars ... I am very worried he wasted money buying a product that is not big enough for his Tesla charging task ... Brand is not even an issue - its suitability to task here ...
@crankydavesmylfs4787
@crankydavesmylfs4787 3 года назад
Hi Andy. I’m not sure if you’ve picked up on it yet but it’s a 3Kva inverter. Not 3Kw. They are rated for 2.4 kilowatts continuous.
@wingerrrrrrrrr
@wingerrrrrrrrr 3 года назад
Is the claimed rating 3kVA peak vs 3kVA continuous? If the load power factor is 1.0, one VA is the same as a Watt-
@jamess1787
@jamess1787 3 года назад
Grounding is funny business, you can only find the relevant information in the code books... The ones cosigned by the union association securities advisory commission. Haha. Usually common copper grounding is good enough. Itll dissipate any induction to ground quick enough: direct strike means your grounding/bonding-means is a momentary tungsten element.
@NaughtyGoatFarm
@NaughtyGoatFarm 3 года назад
Any idea if the all in one units you mentioned (PIP 8048MAX) have a MEN link (link between neutral and earth)?
@hmsb1
@hmsb1 3 года назад
Greatings from portugal. Very nice videos.
@colinbeckitt9495
@colinbeckitt9495 3 года назад
congrats on the new inverter decision and after $1100 of pocket pain, I hope you get some positives from the imminent Inverter swap. As a Victron ‘victim’, I can’t conceive it an upgrade purchase, rather just as expensive pseudo-bling. You definitely won’t get the performance of this little Xijia 3k unit. I am sure the Pheonix Smart 48/3k will prove too small for your needs, so for now, keep your $300 Xijia just for close circuit car charging and use the new Victron for any general lighter loads. Definitely mount the Pheonix in a well ventilated clear area as it will run very hot at the back with only mediocre (2000W) loads. Unlike the Xijia, in that small cabinet along with the little hot running Victron MPPT unit you will definitely have heat issues on >32C ambient days. Can’t wait to see the Pheonix trying to do >2500W constant for even 1hr - its going to get hot as hell on the back plate. They are great quality but simply won’t go near the Xijia for output and cool running.
@FutureSystem738
@FutureSystem738 3 года назад
Nice one Andy 👍
@mondotv4216
@mondotv4216 3 года назад
The trouble with most all in one units is the standby power is usually quite high.
@Jack2of3
@Jack2of3 3 года назад
I've got two lv5048 in parallel. 10kw out and 8kw in.
@OffGridGarageAustralia
@OffGridGarageAustralia 3 года назад
JEEEZZZ!
@lenfryers2839
@lenfryers2839 3 года назад
Don't put the new inverter in an enclosure they have a big fan for cooling it will overheat in enclosed
@randylenart9674
@randylenart9674 3 года назад
One inverter for the car and one for the beer fridge in the garage
@OffGridGarageAustralia
@OffGridGarageAustralia 3 года назад
YES! 🐸🍺
@lennieadi
@lennieadi 3 года назад
Hi Andy. Hope you're well. Question would I be wrong to calculate that a 10kw array would charge a 50kwh battery from empty in 5 hours in full sun 50/10??
@henvan8737
@henvan8737 3 года назад
Whats happening with your Lithium battery low voltage during the discharge test issue?
@OffGridGarageAustralia
@OffGridGarageAustralia 3 года назад
Don't know yet. Battery is still charging up. Lots of clouds here..
@henvan8737
@henvan8737 3 года назад
@@OffGridGarageAustralia Nice and sunny in Melbourne
@unliyou
@unliyou 3 года назад
Charge controllers that goes really really hot have efficiency issues (assuming you did not go beyond specs on its input requirements), not a good design and it does not matter what brand it is.
@OffGridGarageAustralia
@OffGridGarageAustralia 3 года назад
I think all MPPTs do that due to the power conversion. Nothing you can do about it.
@wingerrrrrrrrr
@wingerrrrrrrrr 3 года назад
Do own controllers heat up less than mppt controllers? Figured the more efficient they are, the less heat they dissipate.
@mikoserbousek4987
@mikoserbousek4987 3 года назад
Neutral / "Earth" (ground) bonding exists for GFCI devices. Any current over ground would trip the GFCI, stopping power, that is the primary purpose of the N/G bond. The ground rod, or literal connection to the Earth exists to dissipate static discharge voltage. These are two separate concerns- if you have the N/G bond, even without a grounding rod your GFI will function. Static potential between commonly grounded devices will equalize with eachother.
@Sirslayer_X
@Sirslayer_X 3 года назад
The all in one units are cheaper in America but you didn't mention in why your bms having charging issues to a few batteries..!!.. I'm biting my nails!!
@OffGridGarageAustralia
@OffGridGarageAustralia 3 года назад
I don't know yet, battery is still charging....
@Dirt-Diggler
@Dirt-Diggler 3 года назад
@@OffGridGarageAustralia I'm worried too, started drinking and smoking, a LOT, it's like having baby ! (disclaimer) i drink anyway just trying to get the audiance excited LOL
@fezdk
@fezdk 3 года назад
If the charge controller was mounted to the walls, it would have natural convection from the cooling fins, but sideways on a table, there is no ventilation, so I would expect it to be cooler, when mounted.
@trollgarten
@trollgarten 3 года назад
Just something else....do you have a German background? At 0:34 a "Meterstab" is visible from "Mülheim a.d.Ruhr", I expect to buy this in Australia would be a bit difficlut , or? Btw, I love your vIdeos, very cool stuff and has inspired myself to start a similiar project.
@lyfandeth
@lyfandeth 3 года назад
The lack of a real, separate earth ground is a coomon issue in marine setups, well documented with generators and inverters. The US OSHA has some advice on this, and there is an excellent white paper online for cinematographers and other who usually take gensets into the field, and typically don't pound in ground rods. You are not the first person to have this problem. Tesla is simply following safety standards for *fixed* installations.
@martinly1050
@martinly1050 3 года назад
Did u say 3kva victron for 1160 on ebay? Pls share link as i cant find one for that price
@OffGridGarageAustralia
@OffGridGarageAustralia 3 года назад
Not there any more on eBay. I guess they had reduced the price as 48V system are not very common. They now only have smaller ratings as per the links on my website.
@neliosamch3195
@neliosamch3195 3 года назад
932 doolars at invertersupplydotcom VICTRON ENERGY, PIN482300000, PHOENIX INVERTER 48/3000 230V SMART RENEWABLE ENERGY
@martinly1050
@martinly1050 3 года назад
Hi, we were talking in Australian dollars
@colinbeckitt9495
@colinbeckitt9495 3 года назад
@@neliosamch3195 mmm thats US$932 in Florida - Andy would pay AU$1250 + ~$90 postage to Australia that's way too expensive
@neliosamch3195
@neliosamch3195 3 года назад
@@colinbeckitt9495 fancy stuff with unnecessary features always cost too much!
@paial
@paial 3 года назад
More Victron? Another reason to look at Venus distro for the raspberry pi. ;)
@computeification
@computeification 3 года назад
Is it here yet? Is it here yet? Is it here yet? 🐸🐸🐸
@user-jj2bj4mp7c
@user-jj2bj4mp7c 3 года назад
I know, we Germans are cracy on perfection... So I was just waiting until you go for Victron. I am very curious how you handle the voltage drop of the three cells. I was horrified by this incident! Because I plan to build a 48V bank with 32 cells based on your project. (Btw: there are severall offers on Alibaba for 310Ah cells of the same type)
@MrAdolfo2b
@MrAdolfo2b 3 года назад
I'm no expert but there is something VERY wrong with those three cells
@kyba74
@kyba74 3 года назад
Be careful with the 310Ah cells. They have QR codes scratched out and weigh similar to the 280Ah cells I believe. I'm waiting for others to test them first.
@neliosamch3195
@neliosamch3195 3 года назад
The frog 🐸 is disappointed because Andy is expending big money on a fancy inverter with unnecessary bells and whistles. Aims LF48v 6kw $1500 is excellent. It run the whole house with a/c and ev at the same time. And it has hause neutral or floating selectable.
@OffGridGarageAustralia
@OffGridGarageAustralia 3 года назад
Yeah, AU$2500 here
@neliosamch3195
@neliosamch3195 3 года назад
@@OffGridGarageAustralia I bought it 3 years ago, price has gone up by more than 300 dollars now.
@SedatedByLife
@SedatedByLife 3 года назад
Geeze - if I wasn't in the US I'd buy any spare anything you have for sale lol. Shipping is insane going overseas
@grahamjones6712
@grahamjones6712 3 года назад
Some victron inverters can also charge your batteries cant they? I dont think its an mppt solar charger though i think it mains charges your batteries with a built in transfer switch that does AC passthrough. Usually used in canal boats/rvs that hookup too EHUs occasionally.
@colinbeckitt9495
@colinbeckitt9495 3 года назад
Hi Graham I had a MultiPlus II 48v/3k inverter with built-in MPPT charger and had to buy a separate MPPT as the inbuilt unit was very power limited (~2400W @ 2yrs running loads that the Victron simply couldn't.
@kheavmady8780
@kheavmady8780 3 года назад
Is it ok to use UPS 1kva (900watt) for solar home system? it is a used UPS but a hight end UPS back in the day.
@kheavmady8780
@kheavmady8780 3 года назад
it is 90% efficiency
@kheavmady8780
@kheavmady8780 3 года назад
Is it a good idea to spend 120$ for 1kw inverter with 94% efficiency. That UPS only cost me 15$ with 90% efficiency
@Gnagnie
@Gnagnie 3 года назад
I dont think that is a good solution. You have no change to customize the battery parameters. Your battery will be handled as a lead acid !!!
@colinhudson7426
@colinhudson7426 3 года назад
Typical ups has limited heatsinking. Usually has to work for a short time in order to allow system to power down successfully. May need to provide additional cooling if used for continuous load.
@surplusdoctor
@surplusdoctor 3 года назад
In the usa 6 guage grounding wire is commonly used
@randylenart9674
@randylenart9674 3 года назад
I'd keep the spair ya never know 😎👍🇺🇸
@ankitrajsingh0404199
@ankitrajsingh0404199 3 года назад
Which thermistor do i use in 3s bms 100A bms
@alexandergunda8916
@alexandergunda8916 3 года назад
with 4mm for ground you should be fine (my PV has also a 4 mm). About the charge controler heating up, I think it was designed to be mounted in the vertical beacause the heat disipation is done at the back. Also, about switching back to the grid when the battery is empty - I'm linking you a YT-video (it's in german) ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-Zr0BXeeuAS4.html where the guy is covering a similar issue (he is covering the blackout situation) - could be interesting for you.
@kevinmills5293
@kevinmills5293 3 года назад
I’ve been using a 5000VA Quattro for more than ten years and it’s been faultless. It’s had a lot of abuse too (arc welder and pressure washers) and has always kept going.
@kevinmills5293
@kevinmills5293 3 года назад
Personally, if you’ve already ordered a new inverter, I would ground the neutral and battery negative and see what happens. You could put, say a 10A fuse in the battery positive just in case but I think it will work fine, be safe and usable for the Tesla. What have you got to lose?
@MrAdolfo2b
@MrAdolfo2b 3 года назад
Yea, that cheap inverter you initially purchased was probably the worst component in your otherwise "quality" system. It wouldn't have made for as many interesting videos BUT an all-in-one (Victron EasySolar-II GX for example) would surely have been the easiest, cheapest, highest quality solution PLUS it features a transfer switch with true ME grounding.
@bobbypearson6258
@bobbypearson6258 3 года назад
Put a computer fan o below your controller
@SigmaWorksSW3D
@SigmaWorksSW3D 3 года назад
great! i would buy one if it wouldnt be so expensive for my income
@OffGridGarageAustralia
@OffGridGarageAustralia 3 года назад
They are expensive. One a really tight budget I would just get an MPP
@walterweese2527
@walterweese2527 3 года назад
Phoenix Inverter Smart kenne ich nur bis 2 KW (1600W Dauerleistung) Prüfe bitte ob Du nicht mit einem 48 /5000 ....er besser fährst!!! (wg. Dauerbelastung unter Temperatur) Gruß walter
@OffGridGarageAustralia
@OffGridGarageAustralia 3 года назад
Too late. Bigger is better, yes, but I have a budget too.
@walterweese2527
@walterweese2527 3 года назад
@@OffGridGarageAustralia dam... (schade) But you would be able to connect both inverters to the same battery. Blue inverter for the car; black inverter for what else ever ;o) You must only take an eye on the "melting fuse" in size inside of the battery. 150A would be fine for 7.2 KW ;o)
@walterweese2527
@walterweese2527 3 года назад
@@OffGridGarageAustralia Your battery is good for 13,44 KW (if full loaded) therefore it mean you have "nightloadpower" for your car for about 4 hours.
@AESJoe
@AESJoe 3 года назад
You need sharper/new drill bits!
@OffGridGarageAustralia
@OffGridGarageAustralia 3 года назад
Oh, yes...!
@andreiapostolache3487
@andreiapostolache3487 3 года назад
6:22 all in one unit like mppsolar, voltronic hawe same problem with Earth and neutral they work in "island Mode" when u measure in fase and neutral get 230v but when measure fase and Earth is 115 and neutral and Earth is 115. U hawe to join neutral and Earth with tini wire for just keep the neutral referenced to Earth and then u got 230v measuring on fase and Earth , neutral and Earth is zero now
@smde1
@smde1 3 года назад
Mount the new inverter to the inside of the door of the enclosure.
@OffGridGarageAustralia
@OffGridGarageAustralia 3 года назад
What difference would that make?
@smde1
@smde1 3 года назад
@@OffGridGarageAustralia By arranging the inverter to be mounted to the door you would be raising it and moving it further from the back edge of the enclosure. This would free up additional space in the enclosure for other components like meters, etc to remain inside the enclosure - I am assuming that having the inverter mounted to the door would basically make the inverter capable of being moved out of the enclosure when the door was opened and would thus leave room in the enclosure for other things as well as make it a bit easier to work on the components inside . Of course, you would need to use additional wiring , etc - so that when the door was opened the inverter could still be connected to everything. Additionally, mounting the inverter to the door would take advantage of the heat dissipation capability of a large thin plate of metal exposed to moving air ......... see comment below :)
@KD2HJP
@KD2HJP 3 года назад
Checks Latitude, looks out window. Snow. Ugh
@kevinroberts781
@kevinroberts781 3 года назад
The bigger inverters do it for you. Same thing really.
@thenuts133
@thenuts133 3 года назад
Why not get the multiplus for a few more dollar's
@randylenart9674
@randylenart9674 3 года назад
I'd keep the sa
@jjromba
@jjromba 3 года назад
Teste ma bitte den Eigenverbrauch von dem Victron, hab das hier ma bei nem Effekta Hybrid Inverter gecheckt ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-8hzDs__iuTg.html. Mach weiter so 👍.... Greetings from Lower Saxony
@geraldgrogan
@geraldgrogan 3 года назад
I'm really leaning towards getting the "Victron Multiplus 2 48/3000" www.victronenergy.com/inverters-chargers/multiplus-ii
@colinbeckitt9495
@colinbeckitt9495 3 года назад
Hi Gerald I would recommend you go for a 48/5000 as the 48/3k runs really hot when using the built-in charger at only 2000W PVin which lowers its constant load output in warm weather. Also the PV in volts are very low (70V I think) which really restricts you panel options. Go for an external 60-80A MPPT charger with sat 150v Pvin capability. I battled with a MultiPlus II 48/3k inverter for 3months before replacing it due to it struggling to output even a constant 2000W on hot days. They are simply over-rated so go bigger to a 48/5000.
@geraldgrogan
@geraldgrogan 3 года назад
@@colinbeckitt9495 Thanks for the feedback. Yes, I agree that based on my needs I would probably go for the larger unit anyhow. I'm actually looking for feedback on the product design and functionality of this rather new 'MultiPlus 2' units that they are selling. I really like the design and ease of setup that this unit provides.
@colinbeckitt9495
@colinbeckitt9495 3 года назад
@@geraldgrogan Hi Gerald, I first saw the Multiplus II 48/3k at Intersolar 2018 in Munich and bought 1 in Oct 2018 by mid-Jan 2019 I sold it and bought a much better 4000W Power Jack unit for AU$440 on eBay. To be fair, they should be selling the Multiplus II 48/3k unit as a 1700 - 2000W continuous unit if you are using the MPPT at the same time. Victron are very nicely made inverters but I think designed for cooler countries as they just overheat and drop-out constantly during a Australian Summer day. I paid >$1800 for my Multiplus II and I regret ever listening to the BS everyone had hyped the brand up to as they are simply overated and perform poorly. My mate has a Chinese built POWMR MPS-V-5000W-PLUS inverter that cost $765 free delivery, has 80A MPPT charger, 11,000W surge and easily runs 4500W continuously @36C ambient. Victron has a long way to ho before they can compete!
@jmaus2k
@jmaus2k 3 года назад
Next up DC to DC dump charging the Tesla.......
@offgridwanabe
@offgridwanabe 3 года назад
Well you did it and the Frog said nothing so must be good to go.
@OffGridGarageAustralia
@OffGridGarageAustralia 3 года назад
Ah, is that how it works now?
@computeification
@computeification 3 года назад
@@OffGridGarageAustralia 🐸
Далее
Cool Parenting Gadget Against Mosquitos! 🦟👶
00:21
Это было очень близко...
00:10
Просмотров 3,1 млн
ROBLOX TRAND AGAIN. Part 7☠️🗿🙋🏻‍♀️
00:16
Too many issues with the JK BMS? Time to move on?
30:14
JK Inverter BMS Float Mode and 100% SOC reset fixes!
21:20
Off Grid Solar EG4 Final Battery
17:35
Просмотров 793