The Trouble With Tone - DMM Continuity Test Mode Limitations 

Taking Measure
Подписаться 1,4 тыс.
Просмотров 364
50% 1

Mitch uses a Fluke 117 and Klein mm1000 to demonstrate the features and limitations of using the tone setting on a multimeter.
Check out the Taking Measure website and Mitch's book at takingmeasure.net - www.takingmeasure.net/
Mitch's Beginner's Guide to Electrical Test Instruments - 3+ hours of step-by-step electrical circuit and test instrument basics for students and novices is available to review and purchase through Taking Measures' Udemy link - www.udemy.com/course/the-begi...

Опубликовано:

 

12 авг 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 10   
@alejandrogalarza3147
@alejandrogalarza3147 10 месяцев назад
Another value that manufacturers do not usually show in their data is the voltage between the tips in diode mode, normally fluke has around 7V, klein uses 5V, but most generic multimeters use very little like 1.5 to 3V and that can be a problem measuring IGBT transistors as they do not have enough voltage to switch them.
@takingmeasure
@takingmeasure 10 месяцев назад
Thank you for sharing this comment. Even in DMMs constructed to accepted and adopted standards, the differences in underlying manufacturing parameters for each instrument can be problematic.
@williamsnipes7608
@williamsnipes7608 11 месяцев назад
Great information
@takingmeasure
@takingmeasure 11 месяцев назад
Thank you for watching and commenting. I didn't understand the limitations of continuity test until someone showed me. I am suspect a lot of DMM users are unaware of this.
@williamsnipes7608
@williamsnipes7608 11 месяцев назад
@@takingmeasure I wasn't.
@petersage5157
@petersage5157 11 месяцев назад
Just to show that it *was* a Fluke, Mitch misnamed it twice. Thanks, LockPickingLawyer!
@takingmeasure
@takingmeasure 11 месяцев назад
I sure did! Had a brain cramp there.
@garypoplin4599
@garypoplin4599 6 месяцев назад
3:56 - What does it mean on the Fluke when it gives a pulsating tone in the continuity setting?
@takingmeasure
@takingmeasure 6 месяцев назад
If it does so while simply holding the probes together, the DMM may need servicing. If it does so while connected to a circuit, it could indicate intermittent continuity. You may want to see if the display is also giving a fluctuating ohm reading (if you are within the range of indication).
@waynegram8907
@waynegram8907 11 месяцев назад
Continuity Mode doesn't measure the conductance value of various components or wire gauges plus most DVM meters give false readings when measuring below 2 ohms to milliohms. Example if you're measure Fan motor windings or compressor motor windings which are low ohms but various DVM meters will give false measurements because the range is not designed for low ohms. The DVM meter will measurement 2 ohms or 1.2 ohms for the compressor motor windings but is it really 2 ohms or 1.2 ohms? The DVM meters test voltage and test current might not be strong enough to get the correct measurement of certain motor windings that are designed that operate at a high voltage and high current.
Далее
Ghost Voltages - Interesting and Confounding!
14:14
Просмотров 3,9 тыс.
Losing or "Dropping" a Neutral on a 120/240V System
10:28
кукинг с Даниилом 🥸
01:00
Просмотров 848 тыс.
Comparing a Digital and Analog Multimeter (Updated)
12:29
What is a OPEN Neutral?
3:21
Просмотров 2,7 тыс.
Fluke Automotive 2010 DMM Tutorial F233 and others
27:43
Testing Continuity of a Ring Final Circuit
10:13
Просмотров 77 тыс.