Тёмный

Three Phase Induction Motor Star & Delta Electrical Connections & Formula 

Sparky Help
Подписаться 14 тыс.
Просмотров 1 тыс.
50% 1

Star & Delta electrical connections and associated formula. Ip, IL, Vp,& VL how to calculate, what is the square root of 3 and its origin, how do you apply it in the associated formula. All you need to know for the recognition and understanding for all doing electrical principles, electrical qualifications and those just looking to refresh their knowledge. Three phase explained in simple yet easy to understand way.

Наука

Опубликовано:

 

7 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 4   
@ChooseLife.YourLife
@ChooseLife.YourLife 6 месяцев назад
You didnt explain how to get to the conclusion of 17.32 amps on phase current. On a delta winding Its root3(a.k.a.1.732) x 10² =17.32amps
@sparkyhelp3997
@sparkyhelp3997 6 месяцев назад
Il = Ip x 1.732 = 17.32A
@ChooseLife.YourLife
@ChooseLife.YourLife 6 месяцев назад
@@sparkyhelp3997 it took me ages to figure out as im not good at maths. But it looks like both equations bring us to the same result haha
@sparkyhelp3997
@sparkyhelp3997 6 месяцев назад
Well done, as long as you get to the answer. Please Like, Share & Subscribe
Далее
#kikakim
00:23
Просмотров 9 млн
Electrical Motor Connections
6:16
Просмотров 612 тыс.
Calculating an Unknown resistor explained.
9:42
Просмотров 17 тыс.
The Clever Way to Count Tanks - Numberphile
16:45
Просмотров 793 тыс.
Introduction to 3 Phase AC Systems (Full Lecture)
46:29
BREAKER AND CABLE SIZES FOR ELECTRICAL CIRCUITS.
11:39
Просмотров 170 тыс.
Cool Gaming PC Build! #shorts
1:00
Просмотров 5 млн