Three-Phase Power Explained 

Raritan
Подписаться 22 тыс.
Просмотров 1,4 млн
50% 1

www.raritan.com/
This video will take a close look at three-phase power and explain how it works. Three-phase power can be defined as the common method of alternating current power generation, transmission, and distribution. It is a type of polyphase system, and is the most common method used by electric grids worldwide to transfer power.
To learn more visit: www.raritan.com/

Наука

Опубликовано:

 

14 мар 2018

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 412   
@dane1234abc1
@dane1234abc1 3 года назад
I remember my EE professor from my undergraduate days filling three chalk boards with a beautiful derivation of WHY three phase power, why not 4, 5 or n phase power? Answer: Because three phases was the minimum number of phases whose average power was a constant. Additional phases require additional windings and transformers, so go with THREE phases for the most efficient power grid. Beautiful. How I wish I had a video of his derivation. Even after over forty years as a now semi-retired Electrical Engineer who dealt with RF systems (FM broadcast, TV broadcast, and microwave), it was masterful derivation.
@theachebes5724
@theachebes5724 Год назад
Wow good testimony. Can you mentor someone? I am an electrical engineer
@dane1234abc1
@dane1234abc1 Год назад
@@theachebes5724 Not on 60 Hz AC power. My AC power/motors experience ended with college. My experience is in RF-- its propagation, and also loss/gain calculations for hight power radio and TV stations. Did several 5 MW ERP/60 to 80 kW TPO analog TV designs, but with digital the maximum allowable ERP is just 1 MW, so TPO's are typically in the 40 to 50 kW range. Still, it's 6-inch rigid coax line to handle the power. No more waveguide transmission lines, given that UHF TV now stops at Channel 36 (605 MHz) instead of Channel 69 (803 MHz).
@mcrbyn
@mcrbyn 9 месяцев назад
i'm ee undergrad student, can i get your contact?
@mhlwebs
@mhlwebs Месяц назад
most stupid explanation
@ALM1936
@ALM1936 2 года назад
120V/240V "residential" power comes from a single 240V phase supply line produced from a step-down transformer (secondary side). The primary side of the transformer is fed by one phase (1 of the 3 phases) from the substation (commonly 12kV). The secondary side of the transformer is stepped down to a 240V SINGLE phase output. Because the secondary of the transformer is split into two halves with the neutral (or ground) at the middle of the transformer's secondary winding, two 120V reference-to-ground signals are produced. So there are 3 wires coming from the secondary of that transformer, (2 hot--1 wire on each end of the winding, 1 neutral/ground wire tap at the middle of the winding). Measuring the voltage potential from each hot wire to the neutral wire yields 120V. Measuring the potential difference from one end of the winding to the other end yields 240V (ie. 120V + 120V...actually, 120V minus a negative 120V). This configuration is also called a split-phase system. I added this comment because at 8:00 of this video, it's not clear enough, because it says "it's 2 single phase lines". Technically, it's one phase split into two halves and the waveforms are "out of phase" only because they are referenced to ground at the middle of the transformer winding.
@fuckjewtube69
@fuckjewtube69 3 месяца назад
I understand all that 100%. What I can't understand is how is there not live power on the neutral?
@ALM1936
@ALM1936 3 месяца назад
@@fuckjewtube69 here’s my understanding, take it for educational purposes, not instructional or safety purposes: the neutral wire DOES carry current, specifically the returning current through the home’s loads (ie. lightbulbs, tv’s, appliances, etc…). The neutral wires coming from the loads in a home’s breaker panel are tied to ground and the neutral wire coming from the secondary transformer is also tied to ground at the pole. Because neutrals are tied to ground, the Voltage potential from the neutral wire to ground is minimal. Power can be calculated by multiplying Voltage by the current (Amps). If there is practically 0 volts on a wire, then the power is going to be ~0 as well. **That is why it is possible for a person standing on the ground to touch a home’s bare neutral wire without getting shocked. It is also why the neutral wire coming from the pole transformer into a home is a bare conductor (no insulation). **If there are situations like lost/disconnected neutrals or grounds; ground faults where limbs of a tree touch bare high voltage wires; etc… then this statement may not always be true, it may be possible to get shocked. In summary, it’s about completing a path for current to flow, but also how much force (aka Voltage) behind the current flow; and it depends on exactly what two points in the electrical loop/circuit are being touched/connected in order to cause current to flow.
@jamestaylor3596
@jamestaylor3596 4 года назад
You are a true educator, not only do you make it understandable, you also create the desire to learn more, many thanks
@jakefeisel7348
@jakefeisel7348 5 лет назад
I've was only wondering about 3 phase for about 25 years now, thank you.
@enyakang6950
@enyakang6950 2 года назад
Is there a Grammer error? I have was??? Think you for your advice
@bobsmith3291
@bobsmith3291 2 года назад
Say that again in English
@ianstobie
@ianstobie 2 года назад
@@enyakang6950 Yes. He meant "I was only wondering about 3 phase for about 25 years ..." but another way of saying it would be "I've only been wondering about ...". So he probably started one way then switched to the other without noticing. As you probably noticed, the "only" is ironic, because 25 years is really a very long time to wonder about something. Only been wondering for 25 years! I've been wondering for longer, as I'm probably older and it's a long time since I first heard the term.
@jamesspash5561
@jamesspash5561 2 года назад
Great explanation of three phase. My son is entering the generation field and this will surely help him better understand three phase vs single phase. Me, 30+ years in hydro generation, so sometimes Dads explanations might be a little over whelming. Thanks.
@sdj198801
@sdj198801 3 года назад
Been studying for an upcoming test and needed some refresher material. You explain the material beautifully. Definitely have a knack for explaining complex processes in a simplified manner.
@Sarcastix7
@Sarcastix7 5 лет назад
Super video. The detailed graphics and annotations are really helpful
@jasvirchahal2170
@jasvirchahal2170 5 лет назад
Of all the videos I have watched regarding 3 phase power this is the best one. Thank you.
@wiserdaley6624
@wiserdaley6624 5 лет назад
Thanks for the professional breaking down of information to simple yet informative points. It's great to have instructors like you.
@coloradowilderness3139
@coloradowilderness3139 4 года назад
Simple , Easy , Concise , Thoughtful . Thanks
@janyjozsef
@janyjozsef 4 года назад
The conductors between a voltage source and a load are called lines, and the voltage between any two lines is called line voltage. The voltage measured between any line and neutral is called phase voltage. For example, for a 208/120 volt service, the line voltage is 208 Volts, and the phase voltage is 120 Volts.(9:32) EU: 230VAC => Phase voltage 400VAC => Line voltage.
@niallmcgrath3202
@niallmcgrath3202 5 месяцев назад
This is one of the best descriptions and explanations on the Internet. Thank you
@thomasthoenes3171
@thomasthoenes3171 5 лет назад
Thank you for this very detail video.
@johnkenneally4662
@johnkenneally4662 6 месяцев назад
Best explanation of 3 phase power I have come across. Currently I am an apprentice electrician.
@goedelite
@goedelite 4 года назад
This begins with faulty description of the effect of the north pole of a magnet rotating by a fixed linear conductor. Electrons do not flow towards the north pole of the magnet. According to Lenz's Law, the electrons in the conductor flow in such a direction as to oppose the motion of the passing north pole. That means that as the north pole approaches the end of the linear conductor, the electrons flow in such a way as to create a north pole at its end. As the north pole passes and receded from the conductor, the electron reverse their flow so as to produce a south pole at its end, to attract the receding pole. Lenz's Law is really a consequence of Faraday's Law of Induction, which states in mathematical terms that the direction the induced magnetic field is always opposite to the direction in which the magnetic field is increasing. The electrons in the conduction flow in the direction required to produce that opposing field. In the mathematical expression, the negative sign is what Lenz's Law expresses in words.
@paulfrischknecht3999
@paulfrischknecht3999 3 года назад
Absolutely, good point. I saw the same wrong explanation in other videos about AC...
@GunterPSparks
@GunterPSparks Месяц назад
Boring!
@MdFaiyaz-os2vi
@MdFaiyaz-os2vi 5 лет назад
Super analytical & graphical explanation 👍
@shaggydogg3786
@shaggydogg3786 5 лет назад
At trade school 40 years ago we studied the GM delcotron alternator.. the study materials called it the six sweeps of the alternator... which btw are all three phase... great video!
@allstarshotta
@allstarshotta 4 года назад
Good vid. Memories refreshed
@GavinLon
@GavinLon 4 года назад
Brilliantly explained. Thank you!
@raghukancharla6004
@raghukancharla6004 5 лет назад
Most enlightening video
@kevinbutler6475
@kevinbutler6475 6 лет назад
This is one of the best explanations/animations I've seen.
@abdinassirmohammed1230
@abdinassirmohammed1230 6 лет назад
Kevin Butler Woow. This is absolutely superb explanation. But why have you switched off the save button
@raritaninc
@raritaninc 5 лет назад
How do I turn the save button on?
@daniyalahmad9324
@daniyalahmad9324 5 лет назад
Best explanation ever.....Great work
@swingardjr
@swingardjr 5 лет назад
Thanks for the video. First of yours I have seen and subscribed while watching. Very informative.
@josephb6772
@josephb6772 5 лет назад
Very good very clear explanation, l have been looking at this stuff for years and for some reason for me it just takes one mind and l know......yippee....what a life ...does it ever puzzle you why we have to search for so long before we find the right answer ....why can't we get it straight away
@mikeymcmikeface5599
@mikeymcmikeface5599 5 лет назад
4:18 Why did the electrons stop in lines 1 and 2 even with the magnet rotating?
@coolkid9770
@coolkid9770 3 года назад
@@mikeymcmikeface5599 i dont think it does becuz only one line will ever be perpendicular to the magnet every time it rotates while the other two will be parrallel to the magnet
@bemotivated2220
@bemotivated2220 5 лет назад
very simple and very good explanation as i have ever seen.keep going..........
@ZZZZ-zg3zb
@ZZZZ-zg3zb 5 лет назад
as an EE I want this video to be tough in colleges, it explains it perfectly , I want to go back to college, who would not want to be in college -all you have to do i study nothing else lol kids these days have it made with the internet, this is a great video, I watched it twice because its so well done, who ever did the animation I want them to do my power point stuff and make it like this
@five-forty3431
@five-forty3431 4 года назад
An excellent explanation! Thank you!
@Automationacademytv
@Automationacademytv 4 года назад
Thanks for sharing your knowledge very informative, it inspired me to focus more making electrical video
@buddha65281
@buddha65281 5 лет назад
very helpful... always wondered about 3-phase
@badgardener
@badgardener Год назад
Thank you. This is the first explanation that has made it clear to me
@paulfrischknecht3999
@paulfrischknecht3999 3 года назад
Errata: At 0:40, the sine waves are 60 degrees apart, but they should be 120. Magnets do not attract or repulse electrons. Varying magnetic fields cause electrons to experience a perpendicular force, which is why you need coils in a generator and motor, straight wires would not work properly...
@fernandomolina4101
@fernandomolina4101 3 года назад
Thanks for this great explanation.
@Robizitha
@Robizitha 5 лет назад
Very well.explained .thank u
@brightwriter
@brightwriter 5 лет назад
Another, unmentioned, benefit of 3-phase power is that 3-phase AC induction motors are much simpler, not needing a shaded-pole device on the field windings or a special startup motor to get the principal motor started. A 2-phase AC induction motor, like an internal-combustion engine, can keep itself going but needs a separate device to get it started.
@rcadventure44
@rcadventure44 5 лет назад
We don't use 2 phase. We use single phase, with 2 lines 180° apart.
@Bramon83
@Bramon83 5 лет назад
Common misnomer.
@davidjames1684
@davidjames1684 4 года назад
True (sorta). It is actually 2 phases, but they are phase locked 180 degrees apart and we have access to the 2 hots and that center tap. So in reality, it is a combination of both single and double phase. Imagine if someone had 2 lines each 120V and each having a neutral center tapped to the same transformer's secondary winding. Next imagine if they could put say a 45 degree delay in one of those lines. Would it then still be single phase or 2 phase? If 2 phase, then you are saying that when 2 lines are 180 degrees apart it is single phase but is it really? Some people would agree and some would disagree.
@hellwithit
@hellwithit 4 года назад
Brightwriter also you can reverse direction on it
@junkdeal
@junkdeal 4 года назад
If the starter winding is out or the centrifugal switch is non-functional, you can hand-spin a single-phase motor and it will run both ways. We had a bench grinder with a failed "cent" switch that would have sent power to the start winding. I put a momentary-contact switch in the start circuit, and then at the moment I would turn on the grinder I would push the added switch until it got up to speed, and then let that switch go and all was well! It we didn't hit that switch the motor would howl and not turn. If I hand-spun the grinder wheel backward and then did the other steps before it stopped drifting backward it would run in the wrong direction! Also, if I am not mistaken, the 3-pase motor was invented first, and it was supposedly a battle to make an effective single-phase motor after that.
@Exceltrainingvideos
@Exceltrainingvideos 5 лет назад
Great video!
@markmiller3516
@markmiller3516 5 лет назад
Great explaination!
@garysinghsidhu6390
@garysinghsidhu6390 3 года назад
this is the best explanation I have watched so far
@MystiqWisdom
@MystiqWisdom 2 года назад
Engineering Mindset is perhaps the best channel for this kind of stuff. This is also a good explanation.
@professorvargasp4861
@professorvargasp4861 3 года назад
Thank you about explanation on Three phase. It's really good. Congratulations!
@NickDe39
@NickDe39 4 года назад
Practically all automotive alternators are three phase, when rectified, the ripple voltage was less that 8%, single phase is 100%, no need for huge capacitors. Ideal in plants when AC had to be converted to DC. Three phase motors were very efficient. Three phases 120 degrees apart inherently generated a rotating field, without capacitors so motors could be made much smaller. Wish we had three phase in our homes especially for air and refrigeration compressors and fans.
@marty2872
@marty2872 5 лет назад
I've always been curious where 208v came from and this helped. Where does the sqrt(3) come from?
@benjaminotettey6315
@benjaminotettey6315 5 лет назад
Very good explanation
@sayyidtawaqal1754
@sayyidtawaqal1754 4 года назад
Thanks brother I appreciate your help with this knowledge I'm said from Zanziber in Tanzania how can you please help me with this knowledge
@jefftilghman9059
@jefftilghman9059 4 года назад
That's exactly what I was taught in the apprenticeship classes at Davis Electric. We didn't have animated video available to us.
@kenmichael2888
@kenmichael2888 3 года назад
S
@robbenmitchell7949
@robbenmitchell7949 3 года назад
Did you ride dinosaurs to school?
@spark1545
@spark1545 5 лет назад
Outstanding!
@tarikovictariko9123
@tarikovictariko9123 5 лет назад
Awesome very instructive all the confusing that i had for my whole life was cleared in your 10 minutes video Thanks a lot!
@user-qv6jz4mi6m
@user-qv6jz4mi6m 4 года назад
ΑΡΣΕΝΗΚΟΛΗΘΗΛΑ ΠΡΟΣΟΧΗ ΤΗΣ ΔΙΑΣΤΑΡΟΣΗΣ
@alielmesawi9200
@alielmesawi9200 5 лет назад
You have made it so easy to understand. You're such great teacher 👍👍👍👍
@askarzadeh
@askarzadeh 4 года назад
By far one of the best videos explaining three phase power.
@LSF315
@LSF315 5 лет назад
Nice quality video. Let’s see what else you’ve got.
@JoshxDude92
@JoshxDude92 4 года назад
Good video! Dude sounds like a calm Ray Romano
@petramanuel2510
@petramanuel2510 4 года назад
Great job, keep up
@johng.6129
@johng.6129 3 года назад
thanks for this. I'm a recruiter and working with construction and 3 phase power is a huge plus for what I'm hiring for. Your videos do a great job explaining this to a layperson w/o the background.
@mikenewtonninja9379
@mikenewtonninja9379 2 года назад
you don't want a lay person without the background working on 3 phase, lol, lmfao, pmsl and ha ha. not unless you have a good Hoover to clean up the little pile of dust that will be left where he once stood 💥😵🌬💨👋
@sisir22
@sisir22 Год назад
सर आपका वीडियो बहुत बढ़िया और शिक्षाप्रद है. 3 फेज एसी को आपने अच्छी तरह से समझाया है.
@atomatman3104
@atomatman3104 4 года назад
LOVE THE CHANNEL YESS.
@triggeral
@triggeral 5 лет назад
LoVE It!! Thank you for sharing you knowledge and explaining it well
@mikeymcmikeface5599
@mikeymcmikeface5599 5 лет назад
Would have been better without the crappy distracting music!
@-danR
@-danR 4 года назад
I gave up at 1:44. He doesn't have a clue how fluctuating magnetic fields induce an electric current.
@thedeterminater8757
@thedeterminater8757 4 года назад
@@-danR could you explain what's wrong? I'm not be facetious, I'd genuinely like to know what was wrong.
@simflier8298
@simflier8298 5 лет назад
One of the best explaination and illustration ive heard. Very clear. Thanks a bunch!
@tonydyer5073
@tonydyer5073 2 года назад
Best explanation of 3 phase.
@joshuafrank9084
@joshuafrank9084 5 лет назад
you talked about other videos to watch but they don't seem to be available on the website or youtube , how do you get access to these ?
@MZMA85
@MZMA85 2 года назад
I hope that you can make a video using three phase graph to educate rookie electricians about the danger of letting the phase wires to touch each other in electrical wiring, as three phase wiring nowadays is more popular for domestic electrical wiring compared to single phase
@mauricelaidler4789
@mauricelaidler4789 2 года назад
Fascinating. Thank you.
@deepin2urheart
@deepin2urheart Год назад
Sir any video on phase sequence and detailed discussion on Star and delta connection in Power Transformer
@australianjames1114
@australianjames1114 4 года назад
I had trouble understanding 3 phase but i instantly understood what you were saying & why ac asalates
@rolandmousaa3110
@rolandmousaa3110 2 года назад
GREAT Explaining in simply terms. (inventor)
@Dz-pn7bk
@Dz-pn7bk 3 года назад
thank you so much i loved everything yet i still have a question, how does the delta 3 phases works? and what is the diffrence between these two ?
@Dragon-Slay3r
@Dragon-Slay3r Год назад
Two is clean
@federicomaisch6812
@federicomaisch6812 2 года назад
Excellent video
@jsmcguireIII
@jsmcguireIII 3 года назад
so is the combined output modulating or are the phases so closely synchronized it remains steady?
@jpo1056
@jpo1056 4 года назад
Nice job. Working as an EE in the power field for 40+ years its always been easy for me to understand but difficult to explain to laymen....especially on a napkin with a pen. 😊
@robertkattner1997
@robertkattner1997 5 лет назад
Please explain 12 phase used in electroplating.
@alexcoble8819
@alexcoble8819 4 месяца назад
What about 3 lines carrying 120 Volts each? Is there more than 208 Volts being supplied in that circuit?
@Rick-tb4so
@Rick-tb4so 5 лет назад
Great Video..
@etg9080
@etg9080 2 года назад
Great analysis
@namae190
@namae190 Год назад
Can someone explain the residential 208v, 3-wire setup? It has two 120v legs (that are spaced 120 degrees) plus neutral. Where is the third phase? And wouldn't running a powerful appliance that has a spinning wheel (maybe a power saw) with only two of the three phases cause wobbly performance?
@andrew3234
@andrew3234 4 года назад
best explanation ever
@madhucp6586
@madhucp6586 5 лет назад
i get some knowledge about 3 phase.tq
@seshachary5580
@seshachary5580 Год назад
very educative. Thank you regards
@timelesstrance3720
@timelesstrance3720 5 лет назад
So the odd number is essential for continuous current?
@peteralleyman1945
@peteralleyman1945 5 лет назад
You suggest that electrons are attracted / distracted by a magnetic field. That's wrong. It's the changing magnetic field that causes an electric voltage in the coils.
@yaz2928
@yaz2928 5 лет назад
Lenz law, basic electromagnetism.
@mikeymcmikeface5599
@mikeymcmikeface5599 5 лет назад
The waveforms at 4:50 and 5:25 look totally different. Why is the first one asymmetrical, as if the waves are grouped together? Just a crappy animation?
@-danR
@-danR 4 года назад
9 out of 10 comments are praising this video's claptrap. Unbelievable.
@joshbachman7706
@joshbachman7706 4 года назад
I was thinking the same thing. Anyways, most modern three phase industrial motors are induction and controlled by some kind of VFD.
@dogwalker666
@dogwalker666 4 года назад
@@joshbachman7706 indeed Industrial inverter drives are brilliant for matching speed matching ramps or current limit I have fitted thousands from 0.05kW up to 3000kW fun days.
@sudhakarkhindkar1870
@sudhakarkhindkar1870 3 года назад
Nice explains. Thanks regards
@jonfredidogopia5448
@jonfredidogopia5448 4 года назад
I'm Very Pleased To Watch This Video And That I Can More Understand Its Explanation With The Writing if, My Advice.
@donpixote3321
@donpixote3321 4 года назад
good video the way the narrator tries to go slowly through the material to make sure it gels and gets absorbed. Sadly at this point in time there are 333 dislikes meaning there are 333 confused people out there still scratching their heads with a bewildered look on their faces.
@pkstock372
@pkstock372 3 года назад
If we count the postiive portion of the sine curve , only can see the 2 phase add together , Right ?
@KamranMushtaq
@KamranMushtaq 5 лет назад
Explanation is quite good enough but the rotating magnetic field is generated after current passes we should not place magnet before to understand this that makes it complicated.
@electricalcontractor6944
@electricalcontractor6944 4 года назад
Data centers, and other commercial and industrial buildings don't necessarily use 3 phase power because of less amperes; it is because 3 phase power provides a "more balanced system". Such buildings demand more power than dwellings even though dwellings are served with lower voltage power.
@aymanantoun8898
@aymanantoun8898 5 лет назад
Mr.Raritan Thank you so much Your video is one of the most excellent explanation animation videos again I greatly appreciate your video I would like to upload animation videos Of synchronize rotating machines induction motors, Generators I hope so look forward to hearing from you Thanks again
@scottj4462
@scottj4462 5 лет назад
Unfortunately this doesn't show a very good representation or explanation of how an AC generator moves electrons around, but there are a number of other good concepts in the video that help explain the basics of AC power. Electrons need a loop of wire to move around, and if that were shown (and it has to be in a specific orientation), we'd see that electrons move both towards and away from a magnetic pole in an AC circuit. If it were as simple as saying electrons were attracted to a "+" or "-" as in a DC circuit, they wouldn't be able to move around the loop at all. A better explanation is that the magnetic forces of a north pole push electrons in one direction around a loop and a south pole pushes them in the other direction. In between poles the magnetic forces are near zero so the electrons stop. Further, electrons only move in a changing magnetic field so the magnetic poles have to always be moving or the wires themselves have to be moving. In a large generator magnets rotate (spin) horizontally inside stationary coils made of copper bars that run vertically and the electrons move up or down in the bars depending on whether a north or south pole is acting on them. They also move perpendicular to both the magnetic field and direction of rotation (see Flemings Right Hand Rule for Generators).
@bryanst.martin7134
@bryanst.martin7134 5 лет назад
Scott J Electrons do not necessarily need a wire to move about. Electrostatic charge is one example. Electron beam is another. Old CRT TVs used the steered electron beam for half a century. There are scan converters that still use them today. Then there is always radio. Electrons are not pushed anywhere. They are lured to an electron depleted field through what ever means they can. Open space requires very high potential levels, metal conductors very little. This is a small sample of what you left out of your educated reply.
@terjeoseberg990
@terjeoseberg990 5 лет назад
Bryan St.Martin, Although everything you've said is true, it's irrelevant to the understanding of 3-phase power and the functioning of electric motors. The current in an antenna is negligible compared to the current in an electric motor, generator, or transformer where the electrical circuit is complete. I do agree with Scott J that the pictures in this video demonstrating the magnet and the current in the wire are a bit wonky. The video makes it appear that electrons are attracted to the north pole of a magnet, and repelled from the south pole. If this were true, we could obtain free energy by using magnets instead of batteries. Rather it's the moving magnetic field that induces a force on the electrons. Neither the pictures, nor the explanation in this video explain this, and in fact imply that this is not true. For someone who doesn't understand these things and who is trying to learn, this is going to cause a lot of confusion.
@jeffwells641
@jeffwells641 5 лет назад
There's a reason he said at the beginning of the video that this video requires an understanding of how AC power works, and that if you don't have such an understanding you should watch the video on AC power first. You're criticising this video for something that was explicitly stated would not be in the video. It's like someone saying they are going to show you how to cook pasta, and you're complaining that they skipped over how stovetops work.
@terjeoseberg990
@terjeoseberg990 5 лет назад
Jeffery Wells, I'm criticizing the video because what he's showing is not only confusing, it's wrong. The north pole of a magnet does NOT attract electrons. The wires have to be moving perpendicular to the magnetic flux lines in order for there to be a force on the electrons. The wire has to be oriented so that force is in a direction that causes current to travel through the wire. What is shown in this video will cause no current at all.
@alparker7686
@alparker7686 5 лет назад
Scott, I'm the creator of the video. If you watch the first video, you'll see and hear where I say that while I SHOULD show a loop of wire (per your comment) BUT in order to keep things simple, I will only show half. The issues with creating these types of 7-10 minute videos are: what do I include and what do i cut; what analogies do I use to explain the basic concepts which are rarely well explained. I decided that showing a looping wire would be harder to visualize and animate. It would also open more esoteric topics. My goal was to explain the topic to people who didn't understand 3 phase.
@jayvinbernardo9861
@jayvinbernardo9861 5 лет назад
Cleared and satisfied
@xierxu
@xierxu 4 года назад
Can anyone recommend a microcontroller that puts out 3 pwm signals with deadtime?
@2LZA3EEM
@2LZA3EEM 5 лет назад
Really one of the best explanation but what is r3 ??
@jovetj
@jovetj 5 лет назад
The _radical symbol_ *√* is NOT an "r"-it is a mathematic symbol. *√3* means _the square root of 3._ Or, _3 to the power of_ ½. *√3 ≈ 1.7320508075688772935274463415059*
@reinaldiarevalo3532
@reinaldiarevalo3532 5 лет назад
Dónde puedo conseguir el vídeo en español?
@ktcd1172
@ktcd1172 5 лет назад
Almost all of my higher voltage "Data Center" equipment (Printers, CISC based CPU and HD Racks) required 240v as standard. When we relocated and the power company could only supply 208v to our facility we had to have the manufacturer come out and make adjustments to operate on the reduced voltage. At least now I think I understand where the 208v came from, but why is 240v 3 phase standard for so much of the older, heavier equipment and household appliances such as stoves and dryers?
@Nunya_Business_
@Nunya_Business_ 5 лет назад
Because there was/is a common configuration that is 120V to ground on 2 legs with a stinger leg which is 208V to ground. They are 240 delta with a center grounded winding, quite common where I live. Your company probably could have bought a transformer.
@galendeig6747
@galendeig6747 4 года назад
Very good, thank you.
@claudiovaldivia868
@claudiovaldivia868 4 года назад
Can you translate your videos to the spanish lenguages? Thanks my friend
@d.c.7101
@d.c.7101 4 года назад
Thank you.
@debo4898
@debo4898 5 лет назад
It's just how the AC power is transmitted, it's 120 degrees out of phase from each other. The magnet is the generator that is generating the power i.e. Hydro-electric Turbine at a Dam.
@javierortiz5137
@javierortiz5137 3 года назад
You are correct, but in most cases the generator is moved with burned fuel.
@RubyRhod
@RubyRhod 5 лет назад
Altough the information in this video is completely correct, still one question was not answered: why 3 phases? why not 2, 4, 5, 6? why 3? And there is ONE major reason why 3 phase power is the way to go and the reason is the same why 1, 2, 4 phase power sucks. 5 phase power supply would have been the next choice. why? because power output over time is constant with 3, 5, 6, 7, 9 and so on phases (uneven numbers and any nmultiples of those)
@ahmadbazzoun7481
@ahmadbazzoun7481 5 лет назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-HqZtptHnC2I.html
@RubyRhod
@RubyRhod 5 лет назад
yeah.. that video doesn't explain anything, because the numbers seem to be chosen arbitrarily. so.. no real background there. again: after 3 phase power the next possible number of phases would have been 5 for the reason of a steady power output. but it can be explained quite easy why 3 phases were the way to go - there is no need for a 4 minute long explaination.
@D4V1D83FY
@D4V1D83FY 5 лет назад
Hace mas de 100 años, en los inicios de la electricidad, se probaron sistemas de varias fases, pero el sistema que venció a los demás fué el trifásico.
@alparker7686
@alparker7686 5 лет назад
Here's a simple answer - the cost of copper. The detailed answer is a very technical analysis of cost of additional copper for each phase versus the increased "performance" of more phases.
@RubyRhod
@RubyRhod 5 лет назад
the need for an alternating current with constant power output (and not any sin-wave power!) came from electric locomotives. they would slip with a power peak coming for example from a single-phase sin-wave power. when slipping, the friction reduces a lot limiting the capibilities of it! but with a constant power output the trains could be built smaller and more efficient. and again: 3 phases, 5 phases, 6 phases, 7, 9, 10, 11, 12, 13, 14, 15, ..(any uneven and multiples of those uneven numbers mentioned before) have a constant power output over time. and obviously when they all do the trick why use more than 3 phases? wouldn't have made sense in any way (yes, cost, but also complexicity). always think of the histrory of the technical system you have in front of you and electricity wasn't always for wide public use! then tesla and westinghouse had their stupid fight over AC vs DC is was already decided in europe to use 3 phase AC. that's what noone from the north-american continent seems to know and maybe they just don't want to know..?
@jorgecervantes4094
@jorgecervantes4094 5 лет назад
Can it be posible to have 3 phase panel with 220 v in heach line? Can someone help.
@Inflec
@Inflec 5 лет назад
+Jorge Cervantes - Yes, certainly it's possible but it's not a common scheme, at least in America. 220-240 volts 3 phase *is* common in Europe and most other parts of the world. The closest scheme in America to your question is the 277/480 volt 3 phase system used in factories and large installations.
@AminulIslam-we3kd
@AminulIslam-we3kd 3 года назад
Very nice & useful
@rty1955
@rty1955 5 лет назад
Thank you for using kVA instead of Watts! It drives me nuts when I see people trying to use ohms law for DC circuits, in an AC circuit.
@ZZZZ-zg3zb
@ZZZZ-zg3zb 5 лет назад
roy yung- great point but hey at the end its all in "P" ie power
@JusstyteN
@JusstyteN 5 лет назад
You can use ohms law if the load is pure resistive and power factor is 1
@michaels8050
@michaels8050 4 года назад
Id be one of those people but it's hard to avoid the brainwashing terminology of the ac power fans. Hot neutral and earth? Isn't it power, ground, and redundant ground? Also wouldn't a pulsing DC run a transformer just the same? I mean unless ignition coils are some sort of black magic.
@christopherherrick381
@christopherherrick381 4 года назад
There is always a real component (I.e watts) in power calculation of AC circuits. Apparent power includes the real and imaginary vectors in the calculation and units is VA. Most electricians widely misuse these units and how to calculate them.
@louiskatzclay
@louiskatzclay 2 года назад
At 4:48 the wave forms are not 120˚ apart. I thought that you did not understand. Later on you make it clear that you do. I knew that 3 phase had something to do with generator layout. You made that clear.
@naserzia9795
@naserzia9795 5 лет назад
Good job
@zainrana6241
@zainrana6241 6 месяцев назад
Excellent
Далее
СКУФСКИЙ УЖИН С DERZKO69
19:52
Просмотров 417 тыс.
Алмазная мозаика Mini Gems 💎
00:51
Просмотров 304 тыс.
Alternating Current Explained
7:02
Просмотров 198 тыс.
How Do Substations Work?
12:38
Просмотров 3,2 млн
Installing Three Phase Power In A Shop
15:04
Просмотров 73 тыс.
How Does the Power Grid Work?
10:25
Просмотров 1,8 млн
Electrical Wire Color Coding Used By Electricians
16:14
120/240 and 120/208 Volt Transformer Secondaries
14:41
Просмотров 267 тыс.
An intuitive approach for understanding electricity
39:28
POV: Cuando compras una TARJETA GRÁFICA al AZAR 😂
0:16
What’s your charging level??
0:14
Просмотров 1,3 млн
wyłącznik
0:50
Просмотров 8 млн
Индуктивность и дроссель.
1:00