Тёмный

TIA Portal: S7 Routing / Accessing Devices through two networks 

Hegamurl
Подписаться 78 тыс.
Просмотров 71 тыс.
50% 1

Almost every S7 component supports S7 routing. What does that mean and how does it work? Find out here!
Link to my GoFundMe: www.gofundme.com/f/let039s-fi...
Link to the Website where you can download the software: hegamurl.wixsite.com/automation
Thanks for watching and stay safe!

Наука

Опубликовано:

 

20 апр 2020

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 104   
@acth90
@acth90 4 года назад
Thank you. This is something new even for many advanced TIA users.
@renegadeflower575
@renegadeflower575 4 года назад
I absolutely appreciate everything you put on here. Thanks for sharing your knowledge.
@11rmax95
@11rmax95 2 года назад
I hope you start making TIA videos again. You’re the best channel I have yet to find!
@piterNovy
@piterNovy 4 года назад
Excellent!! It's so simple and so, so handy in a real plant.. Thank you!!
@jorgematassanz5169
@jorgematassanz5169 4 года назад
Great video like always. Looking forward to seeing more videos related with industrial communications.
@phucvu5124
@phucvu5124 3 года назад
Always put a million likes on your tutorial before watching, it's always useful & skillful
@hegamurl7434
@hegamurl7434 3 года назад
Thank you!
@GabrielAlves-or1sn
@GabrielAlves-or1sn 3 года назад
Hi Hegamurl! Your tips are the best! I'm really appreciate it 😊!
@rodrigoromero3112
@rodrigoromero3112 3 года назад
Perfect video! I really would appreciate a series about OSI and network!
@mortedeus1992
@mortedeus1992 Год назад
thanks hegamurl. i hope you share more about TIA PORTAL topics
@mohamadfaizalromli2235
@mohamadfaizalromli2235 3 года назад
Cant wait to try this with router module!.Great video
@sourav_majumder
@sourav_majumder 3 года назад
Thank you so much......this is what I need to do very soon in my work place......connecting two different CPUs running in two different networks & accessing both from my Service PC......
@hegamurl7434
@hegamurl7434 3 года назад
Happy I could help!
@sicilykid91
@sicilykid91 3 года назад
Thank you so much! Siemens support said this wasn't possible!!
@X400DYL
@X400DYL 2 года назад
Spot on and its easy to enter the IP directly on a 1500 Screen, to get you going
@mohamedzouina9794
@mohamedzouina9794 4 года назад
Danke für Ihre Mühe 🙏🙏🙏
@framos9991
@framos9991 Год назад
Thank You!!! Great explanation! Very helpful for learning!
@MrMouais
@MrMouais 2 года назад
Always some good advices Philip ;-)
@sivas5823
@sivas5823 2 года назад
Oh my god... that last tip, where you said changing the IP address requires first time downloading to be done directly. This one issue might have probably caused me hours of issues already in my first few months on PLC programming ! I mean, I have lost a lot of days trying to find the cause of this error more than once. Thank you.
@alexandrumoise1511
@alexandrumoise1511 2 года назад
Great video, just what I needed. Thank you!
@hegamurl7434
@hegamurl7434 2 года назад
You are very welcome!
@alexandrumoise1511
@alexandrumoise1511 2 года назад
@@hegamurl7434 i have a question: Is there a way to use a PLC as a gateway between two subnetwork generally, not just for TIA? For ex, i have a 2PN 1500 with a LAN for devices and a second LAN for an IPC traceability system. Can I connect to a device on the first LAN from the second one through the PLC as a gateway/router?
@amirhosseini4292
@amirhosseini4292 2 года назад
It was very helpful You're the best
@claudio1371
@claudio1371 Год назад
Great video. Thanks for your work.
@sudhindrasukumar2605
@sudhindrasukumar2605 3 года назад
Thank you for sharing this. It was very useful
@hegamurl7434
@hegamurl7434 3 года назад
Cool! Glad it helped!
@michagoralczyk2140
@michagoralczyk2140 3 года назад
Very interesting advice and tips.
@franklintest3769
@franklintest3769 3 года назад
Thank you very much for your explanation.
@aamirawan7998
@aamirawan7998 Год назад
Very cool video!
@hocinebenk4795
@hocinebenk4795 3 года назад
Thank you it's really useful topic
@mohammadhosseinzadeh9012
@mohammadhosseinzadeh9012 Год назад
Thanks my friend for this video
@derina.maleek9408
@derina.maleek9408 4 года назад
Whata topic I loved good job
@MicroBitz
@MicroBitz 4 года назад
Gracias compa! eres lo maximo!
@Sergnavin
@Sergnavin 9 месяцев назад
Дякую за цінну інформацію! ))
@P.J16
@P.J16 Год назад
👏👏👏👏👏👏👏👏👏 Congratulation. Well explained
@sudarsangiri4887
@sudarsangiri4887 4 года назад
Thank you, Have good health`
@vladislavjurasko6504
@vladislavjurasko6504 2 года назад
Great video...
@iran_siemens
@iran_siemens 4 года назад
hi mr plc thank you for this video .
@freemanguess8634
@freemanguess8634 16 дней назад
Great info thanks
@alejandrovr2000
@alejandrovr2000 3 года назад
Great explanation, thank you for the information. Do you know how could I download the same project at once to multiple PLC in the same network? Thank you
@2004michacz
@2004michacz 4 года назад
Awesome, I've never known it's possible
@scodorov
@scodorov 4 года назад
Thanks, useful video
@romangemo8103
@romangemo8103 4 года назад
Good job, thanks
@romeojr.fiecas4952
@romeojr.fiecas4952 4 года назад
Thank you Very Much !!! :)
@user-vt2uc2ew6p
@user-vt2uc2ew6p 4 года назад
Could you also cover the indirect addressing in TIA? Thanks in advance
@irridi5656
@irridi5656 4 года назад
thank you master ;)
@ATOMACH
@ATOMACH 3 года назад
Thank u very much
@yeremiahangi
@yeremiahangi 3 года назад
thanks i enjoy you video. QUESTION: is it possible to make a connection between wincc profesional and et200s, noting that the two are on difference IP range, but both share a S7 1500PLC
@marcinsoboda8499
@marcinsoboda8499 2 года назад
Hegamurl is a maister !!!
@mubarishussain3696
@mubarishussain3696 4 года назад
Thanks you so much
@leebeavers6912
@leebeavers6912 3 года назад
First, thank you for the tutorials! brand new to Siemens Simatic manager, and TIA portal. I have run across an interesting problem. SFC14. The LADDR input is W#16#nnn . what does the W# and the 16# stand for? Where is it getting the information to record it into the ouput? Thanks in advance, and keep these coming. they have been the most helpful and easy to understand tutorials I have seen.
@vandelgog3934
@vandelgog3934 3 года назад
W stands for Word and 16 stands for number of bits (16 in case of word). So output is a 'word of 16 bits'. Word is a datatype.
@nicolasrygaert2789
@nicolasrygaert2789 2 года назад
Great video. Thank you for the content that you provide. I was wondering if you could help me regarding communication between CPU's via routing. My 2 CPU are not connected on the same network but there is a VPN linking them 2. Is it possible to make them exchange ?
@genantamtam9364
@genantamtam9364 3 года назад
Did you activate "Use router" in the properties of the X2 port?
@furkanyarkan1629
@furkanyarkan1629 4 года назад
Hi Hegamurl, Do yu think make videos abaut WinCC V16 lectures(especially scripts vs.)
@mohamadbalkasem1298
@mohamadbalkasem1298 4 года назад
thank you we need you to explain Modbus tcp/ip modbus rs485 in tia we really need it bro
@umairhayatkhan4700
@umairhayatkhan4700 3 года назад
Thanks really informative video
@mounirmohamed8644
@mounirmohamed8644 3 года назад
Thank you very much hegamurl. I'm just wondering if it possible to change the IP address for PLC_1 and PC so it matches the PLC_2 IP address for exemple 192.168.1.3 for PLC_1 and 192.168.1.4 for the PC.
@user-ch1ep4hi7q
@user-ch1ep4hi7q Год назад
hi thx for everything please tell how can I Ritch my encoder connected to plc1 by profibus interface from another plc connected by profinet like you done with HMI but from my user program not from pc
@hungary140795
@hungary140795 4 года назад
Hi, could you make a video of network configuration in tia portal when you have multiple PLCs and and HMIs using a switch (any other switch than what can be found in siemens' repertory? Thank you in advance.
@karoliczanwojtylanu
@karoliczanwojtylanu 4 года назад
17:54 We can not download to PLC 2, because IP adress has been changed. What should we do in this situation? Delete PL_PLC_Network and make it one more time? Then it should work again, right? Thank you for another avesome video!
@abhinetpandey5792
@abhinetpandey5792 3 года назад
Please make video on dprd an dpwr block used for profinet communication for drive
@mdeena20
@mdeena20 4 месяца назад
hi, you are really doing great. Could you make a video on How to Remote access (configuration)of Siemens PLC(s7-1500),HMI(comfort panels) using Suitable Siemens product??? Please.....
@ijasmuhammed7222
@ijasmuhammed7222 Год назад
In this example, suppose the HMI is connected to Profibus port of PLC 2, still is it possible to communicate PC(Connected to PLC 1) with HMI(Connected to PLC 2) ?
@ali-md3th
@ali-md3th 4 года назад
Hi can i put the two profinet interface for plc1 on the same subnet. Second how to manually configure the IP address for plc2
@altabaie
@altabaie 3 года назад
I have a simple network, a PLC, a Comfort panel and a servo drive where each is connected to a Ethernet switch. I can ping each device individually from my latop (where it is also connected to the Ethernet switch). Having said that, I created a network by dragging PLC port to HMI and then to the servo drive. I can't get online with either HMI or the servo drive. Assigning name (update list in dialup screen) returns 0 device found. I can not figure out why TIA can not detect devices.
@SolSwitcher
@SolSwitcher 4 года назад
Huh, ist the routing only available for downloading to hardware? Because every time I plan a robot cell I have to put the HMIs into the warehouse-network-layer just for the sake of reaching it (and watching it via smartserver) with VPN. Great videos by the way, weiter so ^^
@nithinnirmalyam
@nithinnirmalyam 3 года назад
Hi, Excellent simple explanation. Thanks. One question, if the Profibus HMI was connected to PLC_2 , any method to access it via routing through PLC_1?
@hegamurl7434
@hegamurl7434 3 года назад
Pretty much the same way... but have not tried it, so no guarantee😅
@Hamza-zz3zc
@Hamza-zz3zc Год назад
A question : what if you download the changed IP address configuration to the second PLC first and then download to the first PLC ? Would that work to be able to change the IP address via PLC routing ?
@abhishekthakur6139
@abhishekthakur6139 Год назад
Is it possible to show topology network status of plc in HMI screen? in Siemens
@alikhansadykov97
@alikhansadykov97 4 года назад
Great job! Please may u reveal ethernet connection!
@tajindersingh6785
@tajindersingh6785 2 года назад
Please make video on multi-project
@abd_al_monamghanem2718
@abd_al_monamghanem2718 9 месяцев назад
what is the CP communicatin processor to connect winccv7.5 (PC) to 100 RTU VIA PRIVATE APN TCP\IP
@joost9522
@joost9522 2 года назад
Hi! I want to make a connection between a Phoenix AXC 1050 PLC and WinCC Professional Scada. So I downloaded the GSD-File from the phoenix and added it in Tia Portal. But the Phoenix PLC is connected with a ethernet cable to a modem (with M2M Internet SD-Card). Which (HMI?)connection could I use. I do also want to use OPC UA as protocol but I am not sure how to ':). Last question, if this above could work. Should I use IP Adress of the modem or the PLC. Hope you can help me! Joost
@MukeshKumar-ox7uz
@MukeshKumar-ox7uz Год назад
Can you tell how to communicate a profinet device with two PLC both PLCs are in different pn/ie
@younessouberri8612
@younessouberri8612 4 года назад
thanks for the valuable video and, i have one question: i have 2xS7-1215C and 1x KTP700..... the 1215C also has 2 Ethernet ports but the hardware in TIA shows actually only X1. and in topology view there are 2 ports and in network view there is one port, does that mean that both ports has the same addresses?….it is a little bit confusing thanks in advance
@celisgonzalez7867
@celisgonzalez7867 Год назад
FYI, this ports act like a switch, they share the same IP address.
@LaMontanaCompany
@LaMontanaCompany 3 года назад
Hi brother!. I needle to connect to a remote plc s7-1200 from my office. What is the better way? And cheaper!. Thanks
@felixm8788
@felixm8788 2 года назад
hello. how to add equipment library to tia portal for example cpu et-200 im- 155
@dylanj.pozuelocampo5683
@dylanj.pozuelocampo5683 Год назад
This Routing only works for SIEMENS Components? I mean, if Ihave a Modbus TCP device that I need to communicate with a PLC in a connection like the second PLC in your exaple, can I define the first PLC as a default gateway?
@TrungNguyen-dl6rr
@TrungNguyen-dl6rr 4 года назад
If i want to connect my PC to PLC and Internet at the same time (in case i do not have wireless adapter on my PC), what do i need to do?
@danhoigle
@danhoigle Год назад
Thanksa lot! And how can I remotely get to a PLC by using Tia Portal? There is an Ewon connected to the PLC. From Tia Portal I am having troubles to find the decive through the VPN. is there any especial setting? ( I can PING properly the PLC though) Regards!
@vivekbohra7251
@vivekbohra7251 2 года назад
Hi can you Please Configuration of SCALANCE W788-1 RR and SCALANCE W 747-1 RR. Thankyou
@parthaproteemroy9742
@parthaproteemroy9742 2 года назад
Hello Hegamurl I am struggling to connect two S7 400 CPU and one HMI TP1900 comfort panel. S7 400 CPUs are in different subnets
@faithprayer2792
@faithprayer2792 2 года назад
Thank you, but i have one question,i am using S7-300 Plc (PN/DP) and ET200S which uses PROFIBUS, and IFM module which uses ETHERNET,when i download from my PC i use ethernet,but my PROFIBUS module says UNREACHABLE,how can i solve this?
@wildfox1994
@wildfox1994 2 года назад
I want to do something simillar but with PLC and hmi. I have pc connected to one port of PLC and hmi is connected to The second but i cannot find The hmi through PLC. When i'm choosing "Connection to interface/subnet" between PN/IE_1 and 2, nothing is showing on "1st gateway"... What am I doing wrong?
@lahouaribenamara2927
@lahouaribenamara2927 4 года назад
Danke
@shridharnaidu6657
@shridharnaidu6657 Год назад
Ok we can connect & upload program to pc but how we can upload HMI program connected profibus. Sorry I can't get it. Please explain.
@felixm8788
@felixm8788 2 года назад
and, how add smart panel 700ie to Tia portal?
@ingeniebro6666
@ingeniebro6666 5 месяцев назад
So... what about the subnet mask?
@TheBlackPyre
@TheBlackPyre 2 года назад
Hello Hegamurl, ich have following configuration in my plant: PLC 1513F-1 PN combined with a network card CP1543-1. On the network from the PLC is connected a TP700 Panel. Access to the PLC is over the network from the CP. The network from the PLC and TP700 is a 192.168.X.X. The network from the CP is an 172.18.X.X. All Ethernet-Plugs configured to a Subnet. The Ethernet on the PLC is called "Processbus" and the Subnet from the CP (PG-Interface) called "Systembus". I can acess the PLC over the "Systembus" with no problems. But how can i download the software in my panel over the Systembus to the Processbus ?? Is this possible ? Thanks for your effort :-)
@terza98
@terza98 3 года назад
Few correction. If yor network mask is 192.168.0.0/23 it covers IP addresses from 192.168.0.0 to 192.168.1.255. You need to add subnet mask on your diagrams because its fundamental part of routing, switching and subnetting. To be honest, I would never use such complex network. Having switch makes your life much more easier when all devices are in same network. Connecting management server or PC directly to other host (or PLC) is from 1980s. Even this solution works, I do not recommend it. Have been playing with Valmet, ABB and Honeywell systems
@tajindersingh6785
@tajindersingh6785 2 года назад
How to make multi project in TIA Portal
@alaa14781
@alaa14781 4 года назад
hey man i swear i love u , u help me so much please can u help us with MQTT in tia portal and how it send ti ibm cloud
@omarzedan1261
@omarzedan1261 3 года назад
Hi how can I use web navigator via internet without public IP???
@MartinMartinez-vm2mq
@MartinMartinez-vm2mq 4 года назад
Hi, can I do this process but connecting 2 virtual PLC's with PLC SIM?? I do nota have the posibility if buying a PLC so I want yo practice virtually..... Thankyou!
@hegamurl7434
@hegamurl7434 4 года назад
Hi Martin, with the normal version of "PLCSIM" it is not possible to do so. The version "PLCSIM Advanced" can be used for testing networking/hardware. I have never tested it... but I think there might be a free workaround with the standard version of "PLCSIM" using an additional tool called "NetToPLCSim". Link here: sourceforge.net/projects/nettoplcsim/files/latest/download
@MartinMartinez-vm2mq
@MartinMartinez-vm2mq 4 года назад
@@hegamurl7434 thankyou very much. I Will try it....
@eliellobo12
@eliellobo12 4 года назад
Profibus ihm doesn't work?
@Vozzhd
@Vozzhd 4 года назад
Great. Well, does anybody visit forum today?) It is important to rise up forum members, I think. Because almost all forums that I know are close to death. (Of course Siemens Industry support is immoral)
@DoktorSchaedel
@DoktorSchaedel 5 месяцев назад
Profinet > Profibus
@armchairfreedomfighter
@armchairfreedomfighter 4 года назад
Let me know how to buy you 🍺, ☕ or a 🍕❗❗
@timop1276
@timop1276 2 года назад
Would this still work if you had a CP1543 card attached to the PLC and you would try to connect to the HMI? I am trying to make it work with this method, but i can only simulate the HMI but not download
Далее
Basics of Subnets in Ethernet
16:41
Просмотров 13 тыс.
TIA Portal: IO-Devices / PLC-PLC Communication
15:47
Просмотров 103 тыс.
I Built 100 Houses And Gave Them Away!
09:36
Просмотров 56 млн
TIA Portal: PUT Command / PLC-PLC Communication
15:41
VLAN Siemens Tia Portal
4:15
Просмотров 6 тыс.
HMI Connection to multiple PLCs | KTP700 | TIA Portal
10:19
TIA Portal: Program Backup from Physical PLC
6:14
Просмотров 78 тыс.