Тёмный

Total Load Computation 

Jun Aux TV
Подписаться 131 тыс.
Просмотров 169 тыс.
50% 1

Welcome to Jun Aux TV if you enjoy watching this video don't forget to subscribe, like and hit notification bell thank you!
Also visit my FB pages and group:
JB Handyman Services
✓If you’re looking for the right person to fix the problem your facing in your home you can find it here, License Electrical Practitioner is available here, visit us
Jun Aux TV
✓all about Electrical installation and Electrical devices reviews and safety awareness on Electrical
JB Online Shop
✓you can buy product such as Electrical devices mostly on industrial devices
842821366072...
Electrician For Hire
✓group of Electrician looking for a job and giving and taking ideas in one another
JBLyricsVideo
✓its all about lyric video on popular music now a days
Thanks for Watching hope you enjoy. God bless

Опубликовано:

 

5 сен 2019

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 435   
@leoawag578
@leoawag578 4 года назад
Thank you po sirJun sa maliwanag mong explaination,
@junauxtv
@junauxtv 4 года назад
Salamat din po sir
@AngkolTV1984
@AngkolTV1984 4 года назад
New subcriber here!!!Nice video sir dagdag kaalaman to Lalo na sa Amin mga Tesda graduate lng na electrician..more power sir and god bless...pa shout out sa next video mo..salamat!!!
@junauxtv
@junauxtv 4 года назад
Thank you sir...God bless po..
@ramilyap4501
@ramilyap4501 4 года назад
Sir sana meron kang website or mga screen shot PEC Documents guidelines para sa mga electricians incase na may plano silang mag wiring sa isang dwelling unit para mayroon silang pagbabasihan at para makita kung pasok pa ang computation nila sa Standard requirements ng PEC. Para mas lalong makatulong sir. Maganda po ang ganyang video para ma well inform ang mga less skill sa computations but they know the hard work.👍👍👍
@junauxtv
@junauxtv 4 года назад
Meron po sir sa Facebook page pero hindi po lahat soon magkakaroon po tayo ng complete lahat ng mga ginagawa ko at gagawin ko palang ilalagay ko na din po sa RU-vid kaso need nyo po mag join sa paid membership
@seb1553
@seb1553 4 года назад
@@junauxtv sir e libre muna..hahah
@junauxtv
@junauxtv 4 года назад
Pambili din yan ng materials sir for our tutorial haha
@seb1553
@seb1553 4 года назад
@@junauxtv supportahan po namin mga ads mo dito sa yt sir.😁
@junauxtv
@junauxtv 4 года назад
@@seb1553 malaking bagay yan sir....malay mo sir pag umabot na tayo ng 50k subscriber may paraffle na tayo at modern at high tech na mga gamit ituturo ko sa inyo..sana umabot tayo jan sir...
@aglandcebu
@aglandcebu 4 года назад
Sobrang haba ng video mo pero actually nagbasa ka lang. As a piece of advice, mas maganda rin siguro study your subject matter first before conducting your visual explanation. Lahat ng viewer mo marunong magbasa kaya hindi muna kailangan ipakita paano magbasa ng texts. Mas importante cguro doon ka nakafocus sa expectation ng viewer mo like: paano gagawa ng computation by showing sample computation, ilang load (lightings/convenience outlet) sa bawat breaker, etc, etc. para mas maintindihan masyado kahit sa walng background sa electrical wiring na katulad ko kasi gusto ko lang matuto kahit thru you tube man lang at malaking tulong na rin yon sa akin. But anyway ur effort is much appreciated. hoping this comments here would enlighten or inspire other would be Vlogger to be more concise, accurate and be more detailed in presenting their future videos. Ciao!
@junauxtv
@junauxtv 4 года назад
Thank you sir...noted po
@rodrigomosqueda1525
@rodrigomosqueda1525 4 года назад
Tuloy m lang pag vlog nyo sir, hanga ako sa inyo,, bago p lang ak sa channel nyo, ang linaw po ng explaination,,,
@junauxtv
@junauxtv 4 года назад
Opo sir... hanggang nanjan po kayo handang makinig sakin tuloy2 lng tayo...salamat po
@WREVMSTECH
@WREVMSTECH 4 года назад
Lakasan lang ng loob yan. Gagaling ka rin nyan bro. Ipagpatuloy mo lang yan bro.
@junauxtv
@junauxtv 4 года назад
Sana sir.... salamat sir ah...
@WREVMSTECH
@WREVMSTECH 4 года назад
Walang anuman bro.
@tomasteres8296
@tomasteres8296 4 года назад
General lighting load doesnt include convenince outlets. This class of computation is applicable only for electricians because they dont have the right to design legally.
@era1308
@era1308 4 года назад
interesting po house wiring part 3 ..tamang tama po...salamat mr.electrical
@junauxtv
@junauxtv 4 года назад
Salamat din po sir
@roweldeontoy1094
@roweldeontoy1094 4 года назад
Ayos yan master keep it up
@junauxtv
@junauxtv 4 года назад
Thank you sir...
@julitocm964
@julitocm964 4 года назад
Sir Maganda yan explanation may natutunan ako
@junauxtv
@junauxtv 4 года назад
salamt po sir
@viajebyahelang4043
@viajebyahelang4043 3 года назад
Nice video thumbs up
@jimdarrendelacruz3732
@jimdarrendelacruz3732 4 года назад
Nasa pec ito, mga examples. Nice video sir! Thanks for sharing to others. Keep it up po 🙂💯
@junauxtv
@junauxtv 4 года назад
Yes sir...pangalawang example yan sir...tnx din po
@rtagactac
@rtagactac 3 года назад
@@junauxtv what page po sa PEC makikita po yung example?
@beberlyngalvez6553
@beberlyngalvez6553 4 года назад
Maraming salamat talaga na nakapunta ako sa bahay mo...dagdag kaalaman po sir..
@ferdinandresuena2269
@ferdinandresuena2269 4 года назад
Salamat sayo sir may natutunan ako
@junauxtv
@junauxtv 4 года назад
Salamat din sir....basta pag may hindi po kayo naintindihan sir... comment lng po kayo... tulungan ko po kayo
@bobbyfrommindanao4184
@bobbyfrommindanao4184 4 года назад
Idol, topic mo naman tungkol sa paano pumili ng tamang power generator size at single & three phase load computation. Thanks
@junauxtv
@junauxtv 4 года назад
soon sir....tnx po sir..
@jetgamez643
@jetgamez643 2 года назад
Sir sa computation ba na ito(Area method), pinagsasama ba talaga ung load ng gen lightning at load ng convenience outlet? at pano po madetermine kung ilang small appliance branch circuits ang kelangan ng isang residential house?
@heroknaderi
@heroknaderi 4 года назад
Thanks for sharing I enjoyed it you explained everything perfectly I understood everything you said thanks 🙏
@junauxtv
@junauxtv 4 года назад
Maraming salamat po sir
@wkk8835
@wkk8835 4 года назад
Same computation ng total load and sub branch ang 30sq.m. na studio type apartment?
@fernandoagapitojr6361
@fernandoagapitojr6361 4 года назад
boos gling thx sa information about sa tinuro nyo
@junauxtv
@junauxtv 4 года назад
Salamat din po sir
@rubenaledia5706
@rubenaledia5706 4 года назад
Sir gumagamit na ba tayo ng GFCI/AFCI CB dito sa atin instead of common CB especially sa mga residential wiring?
@rolanballero228
@rolanballero228 3 года назад
Stepbystep sna boss😊😄
@introvertedsapiophile5255
@introvertedsapiophile5255 4 года назад
Mas maganda kung maturo mo tlaga yung mga actual load hindi yung rule of thumb.. Kasi pag ganyan pag my dag dag at my circumtances na hindi pasok. Dun magkakamali ka. Pero pag alam mo yung talaga yung logical reasoning kung bakit naging ganyan decision ng pec mas madali mo matatandaan. Kaya kahit ikaw na may binabasa na, still cofused ka pa rin. Kasi na memorize lang yung paano eh solve. Kahit sa demand factor. Rule of thumb yan mga ganyan.
@junauxtv
@junauxtv 4 года назад
Noted po sir.... salamat po
@benitadagatan6095
@benitadagatan6095 4 года назад
Thanks sa lessons mo, magagamit ko sa trabaho ko. Puede mag - request? Sana wala ng background music, para madaling mka -concentrate, salamat.
@junauxtv
@junauxtv 4 года назад
Noted po sir
@ryantumangan6573
@ryantumangan6573 4 года назад
Ohms law lang computation yan sir.....madali maintindihan ng manunuod
@roelalintv1421
@roelalintv1421 2 года назад
Good day sir, solid supporter mo ako sa iyong channel, magtanung lang po ako, halimbawa sir iyong floor area Ng bahay nasa 50 square meter lang tapos Ang daming appliances, Sabihin natin na 3 washing machine, 4 na rice cooker, 3 electric fan, Isang Aircon, Ang tanung ko, floor area parin ba Ang pagbasihan? Salamat po sa iyong sagot, God bless
@Automationacademytv
@Automationacademytv 4 года назад
Good
@junauxtv
@junauxtv 4 года назад
Tnx po
@marlonestoya1109
@marlonestoya1109 4 года назад
sir kulang ka last step po..yong total v/a mo i aad mo pa yon sa 25% nang largest motor mo po w/c is aircon...tapos yong sum non divide mo po sa 230v yon na po net v/a mo..tapos computation na po for service entrance..
@junauxtv
@junauxtv 4 года назад
Hiwalay na video sir...main cb computation po
@charlouespaldon8982
@charlouespaldon8982 3 года назад
Boss tanong lng po.pwd ba maki series ng ilaw sa breaker ng aircon? 20 A sya ang gawing kng ilaw tatlo lng.at yung gamit q 2.0 lng po.hnd ba dilikado? Salamat
@neriomorta5865
@neriomorta5865 3 года назад
sir,.,ano poba ang kdalasang main circuit breaker sa residential house wiring.,.yung maliit na bahay lang.,.,like mga sampung ilaw,.,na 10 watts ang isa,7 outlet.,.at saka may isang refrigeretor,.,.,.at ilan po ba ang CB ang ilagay dito ?thankyou
@papajesussaviour102
@papajesussaviour102 4 года назад
Jun...laki ng pakinabang ng PEC hehehe
@bjorn149
@bjorn149 4 года назад
master ask ko lang ano po dpat gamitin ko na breaker pag ang appliances ice cream maker 1.7kw blender (2) - 1500w each ref 78w lights 100w.
@junauxtv
@junauxtv 4 года назад
Base don sa binigay mong load sir may total ka na amps na 21.21...kaya na ng 30amps cb 3.5 wire THHN stranded wire Phelps dodge or Philflex
@cyberbeast1789
@cyberbeast1789 2 года назад
Area method malayo sa katutuhanan ata,.. maraming maliit na bahay pro maraming load. marami ding malalaking bahay mas maliit ang load.
@yakult4544
@yakult4544 4 года назад
Thanks sa video mo, very helpful po. Tanong lang po, saan ba ma babasa sa PEC yong not more than 6 lang na circuits ang kailangan i install sa bahay na merong less than 150sqm floor area?
@junauxtv
@junauxtv 4 года назад
Page 1046 sir....2017 edition
@ecks347
@ecks347 3 года назад
@@junauxtv Pano sir kung marami akong ilaw na gusto install sa bahay ko or marami akong loads, it would be more than 6 circuits na. like sa Ref ko, hiwalay ang breaker nyan, motor pump ko, hiwalay, ilaw sa fence lighting, pero nasa 110 sq m lng house ko?
@nyarogaitnas6388
@nyarogaitnas6388 4 года назад
Mga master katanong lng po sa acu isang 1hp at 1.5hp nagkabit ako ng #10 awg wire tapos ang separate branch circuit breaker dalawang 20 ok lng po bayon kahit malaki ang wire ?sana po masagot salamat
@withlovemotovlograndomvide107
@withlovemotovlograndomvide107 4 года назад
Sir magandang hapon! 60Amp Main Breaker Mag jumper po ako ng 30Amp para sa 3 lights,2 Outlet ok lang po ba?
@AweRepublic
@AweRepublic 2 года назад
Hi Sir, Pwedi po bang magpagawa ng load schedule sa inyo? We will pay for your service po.
@29mredwin
@29mredwin 4 года назад
sir jun pwede kaya yung wala ng main breaker? gamit ko ay 20amp circuit breaker para sa convenience outlet at 10 ampher naman po para sa ilaw.
@jay-armendoza7376
@jay-armendoza7376 4 года назад
boss okey lang ba kahit mas malaki ang total computation ng Sub Circuit breakers natin sa panel board kesa sa Main Breaker? atsaka ano maging epekto pag ganyan ang set up? maraming salamat boss.more power sa channel mo.
@ryanjayawitan4551
@ryanjayawitan4551 4 года назад
Master dapat cinasabi modin kung saan naggaling ung ibang VA kc meron naman table or section na pinagbabasehan nyan...nalilito ang manonood nyan!
@junauxtv
@junauxtv 4 года назад
Separate ko nlng yan sir...ng video
@rafaelmejia5505
@rafaelmejia5505 3 года назад
Sir 3rd class BUILDING WIRING ELECTRICIAN po ako. Anong school po kaya na pwede ko pasukan na kaya ng budget ko to be a MASTER ELECTRICIAN?
@isaganimartin3096
@isaganimartin3096 4 года назад
good eve new member po.. nxt tym po question po ako. salamat sa tutorial..
@junauxtv
@junauxtv 4 года назад
Salamat sir....pwd na po kayo magtanong sir no probs po
@montv9612
@montv9612 3 года назад
Correction sir Jun. That is not derating factor. When you derate, you go lower. Please make a correction nalang thru comment kasi mali po talaga sir. Thank you
@jomarcallos7563
@jomarcallos7563 3 года назад
gd pm po sir jun itanung q lng po , panu kung hindi namn umabot ang sq.m ng bahay sa 150 o 145 , lessthan 100 , kailangan po ba i times sa 24 or familu dwelling salamat po more power
@roderickrecimo5069
@roderickrecimo5069 4 года назад
boss saan galing yung sub-total na 6480 va. tsaka bakit po di mo sinama yung sa general lighting and receptacle load sa total load
@danverlangote9760
@danverlangote9760 4 года назад
Sa kakamadali mo ang hirap. Mong intindihin.. Walang klaro turo mo
@danilogo235
@danilogo235 8 месяцев назад
Sir jun dapat ang main breaker, para sa akin ay volt on. Para nka seperate ung 6 branches na plug in.
@aeij91
@aeij91 4 года назад
Sir ask ko po if need pa ba seperate ang breaker para sa ilaw and c.o?in which case pwede nman as one nalang..ricemill man lang nman
@junauxtv
@junauxtv 4 года назад
sa standard po sir dapat po hiwalay..
@unavita8158
@unavita8158 4 года назад
Wag pagsamahin
@daniloperez5067
@daniloperez5067 4 года назад
Sir gud pm halimbawa 100amp sa lima 3 r at sa panel board kung no . 2 na wire ano nman sa outlet at ilaw anong pwedeng wire na iinstall na wire.?
@rolandcadiao3973
@rolandcadiao3973 3 года назад
main line circuit breaker sir ok maba yan sa 2 floor house..
@hatchiretchistudio5148
@hatchiretchistudio5148 4 года назад
tanong ko lang po idol pwede po ba yun ' yung load service entrance sa meter na 5.5 mm dudugtungan ko ng #6 na wire papuntang main circuit breaker? Kasi yun po idol ang nkalagay sa load service entrance eh 5.5mm 🙏 sana matulungan nyo po ako idol ,maraming salamat po🙏
@cristinemae3073
@cristinemae3073 3 года назад
Sir! Good evening, pwede po bang mag kabit ako ng mas mataas na ampere kesa sa main breaker?
@xtinct1716
@xtinct1716 4 года назад
Sir ask ko lng over ba 30 amp na circuit breaker sa isang floor ng bahay?
@junauxtv
@junauxtv 4 года назад
Depende po sa magiging load nyo sir...if hindi po lumalampas ng 16amps ang load nyo at walang mga special purpose outlet pinapayag po ng PEC na isang breaker lng po...
@sheilaygot4324
@sheilaygot4324 4 года назад
.master yong sa small appliances na 20amps breaker na may 1500VA nasa pec ba yun?? Or standard naba yun master?? Tanong lng po, salamat master.
@junauxtv
@junauxtv 4 года назад
As per PEC mam for small appliance 180VA per outlet mam..
@errikempio9107
@errikempio9107 4 года назад
Sir, how about assumptions po? may iba kasi na nag aassume ng wattage ng load. For example, 180W per socket, and if 3 gang po sya magiging 540W, at ito na rin ang dinidivide ng 230V. Ito na rin nagiging basehan nila sa wire size at breakers na ginagamit. ano po opinion ninyo regarding dito? advisable po ba sya? TIA po.
@junauxtv
@junauxtv 4 года назад
Sa code book kasi sir 180va ang per outlet sa mga small load appliance...take note sir small load appliance..
@errikempio9107
@errikempio9107 4 года назад
Thanks for answering sir. More power po sa channel ninyo.
@shupingyao3885
@shupingyao3885 4 года назад
Master magkaiba po ba ng circuit breaker ang ref, washing mashine, at outlet ng pra sa oven?
@junauxtv
@junauxtv 4 года назад
Yes sir as per PEC iba ang sa ranges at laundry mo sir
@shupingyao3885
@shupingyao3885 4 года назад
Salamat po master sunod yun na gagawin ko😁,, mag ksma kc sa compute ko na 200watts per co ang ref at oven,,, ung aircoin lng nabubukod ko
@nielgab2731
@nielgab2731 4 года назад
alin po ba yung mas updated or latest revision, yung "24 VA/sq.m or 33 VA/sq.m"?
@junauxtv
@junauxtv 4 года назад
24VA sir
@nielgab2731
@nielgab2731 4 года назад
salamat
@coachpepz777
@coachpepz777 4 года назад
Sir, pwede po bang gamitin na lang yung wattage imbes na va sa total load? Kasi kpag total load e watts ang computation ko o ang ibig sabihin, nalilito kasi ako kapag puro va. Tama po ba ako? Paki correct din ako, thnk you sir.
@junauxtv
@junauxtv 4 года назад
Volt x ampere= VA sir
@dwanedavid4997
@dwanedavid4997 4 года назад
Va=watts
@junauxtv
@junauxtv 4 года назад
May nagsabi sakin sir VA is not equal to watts Watts=VIPf
@doods4301
@doods4301 4 года назад
@@junauxtv just use watts instead of VA.mga ordinaryong electricians lang ang mga nagtatanong parang madaling maintindihan.
@GameOP890
@GameOP890 2 года назад
sir ilan flloor area kapag 2-storey? times 2 ba ng ground floor area?
@ljcrudz4269
@ljcrudz4269 4 года назад
boss, yung One branch circuit of "20-ampere", sa video you change it to 15 ampere.. mali po ba yung PEC?
@junauxtv
@junauxtv 4 года назад
Ako mali jan sir....20 po dapat yan sir...
@ljcrudz4269
@ljcrudz4269 4 года назад
@@junauxtv ngwonder lang po. . . sana may tutorial using actual na design. kahit isang floor lang. anyways, thank you sa video. malaking tulong po.
@junauxtv
@junauxtv 4 года назад
Salamat din po sir....
@twilightzone2651
@twilightzone2651 4 года назад
Ayos lakay!
@sannylozada2114
@sannylozada2114 4 года назад
Hello sir Good morning. Advice lng sir nakabili q ng panel board s riyadh ang main switch 100 ampere ang circuit breaker 30 ampere tapos nakabili din q ng wire N.H ang size 12 pwede b gamitin s aircon at iba p ang size 14 naman pwede s lahat n ilaw.thanks
@junauxtv
@junauxtv 4 года назад
Ilang hp ba sir ang aircon mo sir?
@torcrame4183
@torcrame4183 4 года назад
Mahirapan ata ang vlogger sagutin ang tanong mo dahil kulang ang detalye na binigay mo. Main 100A, at tama dapat malaman muna kung ilan at anong rating ng aircon ang gagamitin mo. Ang mga wire kasi na ginagamit natin at may ampacity rating depende kung anong size ng aircon gagamitin mo.. kung 1HP na WAC ay possible ang nabili mo na 12AWG sa abroad. Isa akong RME.
@junauxtv
@junauxtv 4 года назад
Salamat sir....
@ronelrayos3720
@ronelrayos3720 4 года назад
Sir pag nag install kaba ng outlet ng aircon kailangan may sariling circuit breaker yun?? Tnx
@junauxtv
@junauxtv 4 года назад
Dapat po sir
@ronelrayos3720
@ronelrayos3720 4 года назад
Ilang amp. Pwede gamitin sa 1.5hp na aircon sir? Tnx!!
@junauxtv
@junauxtv 4 года назад
@@ronelrayos3720 20amps po sir
@dondonracingpigeonlofttv7463
@dondonracingpigeonlofttv7463 4 года назад
@@junauxtv ilang aircon na 1.5hp ang Kaya ng 20ams sir?
@junauxtv
@junauxtv 4 года назад
1:1 po pag aircon sir....1aircon 1 cb
@TreasureSign2023
@TreasureSign2023 3 года назад
Gud evening sir Wala po ba kaung vlog about sa mga malalaking wire tulad nang THHN na 250mm or 150mm or 300mm na kapag mabawas ang wire ay Alam mo rin Kung ilang mtrs and natira, salamat po
@papajesussaviour102
@papajesussaviour102 4 года назад
Jun....ito ung example sa last part...PEC part1.
@junauxtv
@junauxtv 4 года назад
Opo sir....ulitin ko ung video na yan sir....hindi maganda pagkadeliver ko jan sir...haha
@papajesussaviour102
@papajesussaviour102 4 года назад
@@junauxtv bro....total load computation...gawin mong Total Computed Load.baka dyan sila naguluhan.hahahaha
@johnwalterjeminez7856
@johnwalterjeminez7856 4 года назад
Sir sa PEC sir ung ilaw para sa braeker talagang 20 amphere na ? Binago na ba sir hindi na 15 amp breaker
@junauxtv
@junauxtv 4 года назад
Either 15amps or 20amps depende sa floor area ng bahay sir...
@dariusbactol4776
@dariusbactol4776 4 года назад
20amps na po ung updated
@nevermind1681
@nevermind1681 4 года назад
Naguguluhan k din s paliwanag mo eh ...haha
@junauxtv
@junauxtv 4 года назад
Ano po ba ang hindi mo naintindihan sir?
@totobob2607
@totobob2607 4 года назад
ok po sir paliwanag ninyo po hnd magulo madali po kau magpaliwanag salamat sa vlog ninyo po
@junauxtv
@junauxtv 4 года назад
Kaso sir hindi po lahat nakacath up anyway maraming salamat sir
@jeffdelarosa9960
@jeffdelarosa9960 4 года назад
Master lodi tanung kulang po sana my videos kyu kung gnu kadaming autet at swecsh ang kyng dalhin nang bawat breaker at ung wiring na gagamitin .. bguhan lng po kc ako ..slmat po
@junauxtv
@junauxtv 4 года назад
Meron na po sir....check mo sir ung ibang video natin...
@observeronly
@observeronly 3 года назад
pwede po magtanong? sobra po taas ng electric bill namin. kalilipat lang po namin dito. dati po konsumo namin hindi tumataas ng 900 pero ngayon po umabot kami ng 3k. ang appliances namin, basic lang. isang 7 cu ft na ref, dalawang computer, 2 electric fan and isang rice cooker na bihira namin gamitin, washing machine na 2x a month lang gamitin. dalawa lang po maliit na kwarto. isang electric water heater na once a week gamitin. wala po kami aircon. dalawa lang po kami sa bahay. wala naman po naka jumper kasi pag pinatay namin yung main switch, patay naman po lahat. hindi po kaya dahil yung wire na naka connect papunta sa metro ay dugtong dugtong at luma na? ano po kaya dapat gawin? 4 months pa lang po kami dito pero umabot na mahigit 10k binabayaran namin. help naman po. salamat
@cristinemae3073
@cristinemae3073 3 года назад
💟
@roelalintv1421
@roelalintv1421 3 года назад
Ask Lang po ako sir, saan po ninyo kinuha iyon 35 percent?
@tristan3281
@tristan3281 4 года назад
Sir jun, ilang amp po ba na circuit breaker para sa 1hp na aircon?
@torcrame4183
@torcrame4183 4 года назад
1HP @ 230V use 20AT. Why I said it. FLA or Full Load Ampere of 1HP is 8 Amp only, then add the starting current so 20AT is enough.
@junauxtv
@junauxtv 4 года назад
20AT sir
@xtinct1716
@xtinct1716 4 года назад
Kaya ko natanong ung 30 amp un ung common na ginamit sa mga small houses, ask ko na rin ilang air-conditioning ang kaya ma hold ng 30 amp na circuit breaker kac ung ibang ng electrian 1 / 1 ang set up nila, mali ba un sir?
@junauxtv
@junauxtv 4 года назад
Pag aircon po sir 1:1 po talaga tayo jan sir as standard depende sa rated ampre ng aircon para don sa ampacity ng breaker na ikakabit sir
@BordzAbyanJumong
@BordzAbyanJumong 4 года назад
Ganun din napanood ko bro, kay maharlikan channel.. 60 main 30 at 15 ang sub... Sabi nya di dw dapat lalagpas ang sub sa main
@junauxtv
@junauxtv 4 года назад
@@BordzAbyanJumong iba ung skin sir standard po tayo from PEC 60 main 5 20amps na cb...
@charlsnorveescrupolo1182
@charlsnorveescrupolo1182 4 года назад
Nkaka CONFUSED yung ganito..may naririnig ako na di dapat lumagpas total load ng sub breaker sa main breaker..pero sa nakikita ko na mga panel lagpas ang total load ng sub breaker sa main breaker...hope this issue will tackle...
@junauxtv
@junauxtv 4 года назад
Confused ka pa rin ba sir?ang sample na yan sir from PEC Electrical Code...ang Philippine Electrical Code po sir yan po ang sinusunod ng mga PEE,REE at RME...kung sino man nagsabi sa inyo sir tanongin nyo po kung ano or sino reference nya?saan nya nakuha ang computation nya?
@robertjrsitjar3133
@robertjrsitjar3133 4 года назад
wala ba magiging poblema sir kung mas malaki ang total ampherage ng mga sub CB kumpara sa main breaker? many thanks po. God bless! and more power.
@junauxtv
@junauxtv 4 года назад
Wala po sir....tnx din po sir
@jerryjavier5899
@jerryjavier5899 4 года назад
Sir jun ask ko lang, kung ilang amp na cb ang gagamitin sa welding machine
@junauxtv
@junauxtv 4 года назад
ilang amps welding machine mo sir..
@jerryjavier5899
@jerryjavier5899 4 года назад
@@junauxtv 300 amps po
@richardmatuguinas2898
@richardmatuguinas2898 4 года назад
nice sir...napakinabangan mo din...maganda na topic yan...dapat inayos mo ung paliwanag mo.....good job pa din...hehehehehehe
@junauxtv
@junauxtv 4 года назад
Yan lng kinayanan sir...hahaha.... salamat po sir
@seb1553
@seb1553 4 года назад
Sir gusto ko makita full installation mo sa buong bahay at ang computation mo yung nasa 2 storey sana sir..thank you po.😊
@junauxtv
@junauxtv 4 года назад
Matagal pa ung two story sir...hehe... installation muna tayo pero sa wiring board lang ididisccuss lng natin mga important guildlines sa installation ng mga devices and equipment
@seb1553
@seb1553 4 года назад
@@junauxtv ok po sir, thank you po.
@ryg9522
@ryg9522 4 года назад
Kung more than 6-circuits ba ay iba na ang magiging process ng computation? Do you mean kung above 150-square meter na ang area ay mababago ang computation considering residential pa rin or dwelling unit pa rin peru larger lang ang floor area? Sana masagot to avoid confusion Sir
@junauxtv
@junauxtv 4 года назад
Opo sir kung ang pagbabasihan natin sa computation is total square meter po ng bahay sir..para mas madali sir...total load nlng sir ng mga appliances
@ryg9522
@ryg9522 4 года назад
Jun Aux TV Sir, if ever mayrun pa akong idagdag na electric range...pwede ko bang idagdag dito as Other Loads? Para masama ko sa pag sum-up sa pagkuha ng Net Total Computed Loads for Main CB and wire sizing for Service Entrance. Yung computation ko ba sa Electric range ay the same sa video niyo about electric range?
@ericksonserviano5821
@ericksonserviano5821 4 года назад
Pwd po sir. Sna un mas malinaw n paliwanag. Ska sna paki actual n lng paano m nakuha sna may calcutalor. Slamat sir.mganda sna kaso diko ma gets maigi slamat sir
@junauxtv
@junauxtv 4 года назад
Noted po yan sir.... salamat po
@emersonulpindorn9725
@emersonulpindorn9725 4 года назад
Napakagandang video neto sir! Medyu nalito lng aq sa panel board, mei napanood kc aq na nagsabing hindi dapat lumagpas ang total ng sub-breaker sa main breaker. Sa inyu po sir 60 amp ang main nyu na mei limang 20 amp sub na base sa total load computation. So meaning ba neto i can still use a 100 amp main, basta hindi aq lalagpas sa total of 6 circuits? Please enlighten me sir! Thank you in adcance!
@junauxtv
@junauxtv 4 года назад
Ganto yan sir...may computation para sa main breaker.yan ung kasunod natin na video....hindi ko po alam san nya nakuha ung sinabi nyo po..ang reference ko sir PEC Philippine Electrical Code which is yan yong sinusunod ng mga Electrical Practitioner throughout the Philippines, standard kumbaga.... taposin lng natin ung mga video natin sir...jan malalaman mo sir kung nasa standard ba ang panel board nyo sir
@emersonulpindorn9725
@emersonulpindorn9725 4 года назад
Ayun! Maraming salamat sir! Malaking tulong talaga eto, at aabangan q series ninyu all the way! Responsibility din kc nating malaman ang tama hindi yung asuming pra sa safety ng lahat. Sir kung pwd sana if mei pag kakataon gawa din kayu video about how to install manual transfer switch para sa backup generator to safely connect sa selected circuit sa bahay. More videos to come po!
@junauxtv
@junauxtv 4 года назад
@@emersonulpindorn9725 cg sir pag nakabili po ako ng mts sir...ang meron palang tayo sir ATS...ayaw mo ba ng ATS sir?
@junauxtv
@junauxtv 4 года назад
@@emersonulpindorn9725 salamat sir ah sa pagsupport sa channel natin....tnx tnx
@emersonulpindorn9725
@emersonulpindorn9725 4 года назад
Jun Aux TV ang nabili ko po kc n generator portable lng which is yung bosco 2300 watts inverter from handyman. Typically designed sa small load lng kaya q namention MTS. Ang nasa isip ko is by using DPDT knife switch to prevent backfeed. I got this idea from this blog myphilippinelife.com/philippine-electrical-wiring/. Cguro pag nakabili nq ng generator that can suport the entire house i will go for ATS.
@domsrequino3865
@domsrequino3865 3 года назад
boss yung SMALL APPLIANCE LOAD para san yun at anu mga sample na appliances nyan boo...thank you po nag aaral palang ako boss gus2 ko atuto..slamat po
@BISDAK370
@BISDAK370 4 года назад
Sir pwd papasa ng general lighting load by occupancy at c.o ?
@junauxtv
@junauxtv 4 года назад
Hindi ko pa napasa sa cp ko sir..pag open ko uli ng pc sir pasa ko sau
@BISDAK370
@BISDAK370 4 года назад
Ok sir salamat ng marami
@ruelabanid479
@ruelabanid479 4 года назад
May vedio kba sir pano malaman na overload na ang isang circuit breaker anu mga test ang gagawin?anu dapat ang mga pamamaraan pra hnd mag overloading..
@junauxtv
@junauxtv 4 года назад
Wala pa sir...eh...try ko dagdag sa topic na pwd nating gawan ng video sir
@ruelabanid479
@ruelabanid479 4 года назад
Thank you sir
@joelitojrdelacruz978
@joelitojrdelacruz978 4 года назад
Sir kung 20 amp CB ang gamitin pati Sa mga ilaw it means number 12 na wire gagamitin po?.
@junauxtv
@junauxtv 4 года назад
Yes sir tama po
@judynarmordeno6455
@judynarmordeno6455 4 года назад
hirap mong intindihin sir hehe
@junauxtv
@junauxtv 4 года назад
Thank you sir...God bless
@rolanballero228
@rolanballero228 3 года назад
Boss pwed pkilinaw,bagohan pa ako eh😊
@Elmaintenancetv08
@Elmaintenancetv08 4 года назад
Master tanong ko lang. May isang circuit para sa ilaw, may para sa convenience outlet, sa laundry, at sa air-conditioning? Tama po ba?
@junauxtv
@junauxtv 4 года назад
Add mo pa sir small appliance
@thomaslapas6250
@thomaslapas6250 4 года назад
sir alam ko makasabot ka bisaya,sir mangutana lang ko makapalit ba ko og libro bahin sa electrical para kung naa ko e install motan.aw nalang ko sa libro unsaon pag calculate,sa TESDA man gud sir dile man e tudlo tanan step by step theory lang pila ka minutes then actual na dayon mas ganahan ko dile pataka og taod nga walay sakto nga computation sa mga branch circuit og main breaker
@junauxtv
@junauxtv 4 года назад
Sir PEC ang magandang book na dapat magkaroon tayo...kaso limited lng sa member...i think....pero my ongoing akong ginagawa sir na sa RU-vid kayo magbayad din maaccess nyo ang mga ginagawa kong table, picture, at video na base sa PEC
@jubeleoluspo184
@jubeleoluspo184 4 года назад
Sir paano pag ang size ng Bahay is 25'x21' lang pede naba yan iapply or meron pang another computation?
@junauxtv
@junauxtv 4 года назад
inches ba to sir?
@jubeleoluspo184
@jubeleoluspo184 4 года назад
Ft' po yan sir 21×25ft'
@jadigumera3110
@jadigumera3110 4 года назад
Sir ask ko lng 2hp ng ac lan po ba amps dapat na breaker?
@junauxtv
@junauxtv 4 года назад
20 amps 3.5mm wire sir
@charlesaugust9219
@charlesaugust9219 4 года назад
30A using 5.5mm². Refer to pec table sa power rating ng mga motor load.
@charlesaugust9219
@charlesaugust9219 4 года назад
30A @ 5.5mm² Cu wire.
@mhackytario1335
@mhackytario1335 4 года назад
Sir kapag 2 or 3 story residential, 24 parin ba ang multiplier???
@junauxtv
@junauxtv 4 года назад
Yes sir basta dwelling sir...
@mhackytario1335
@mhackytario1335 4 года назад
Okie po tnx
@leinx8024
@leinx8024 4 года назад
Sir, puede bang malaman kung ano table yun 100% para sa 3000 volt-amps, at yun excess ay para sa naman sa 35%..? salamat at God bless.
@junauxtv
@junauxtv 4 года назад
Demand factor po sir....
@israelvillar3510
@israelvillar3510 4 года назад
kua jun saan po galing ung 1500va ,bat sya naging computed load nito.
@junauxtv
@junauxtv 4 года назад
for small load appliance sir 1500va as per PEC
@ricoasi859
@ricoasi859 3 года назад
THANKS FOR THE VIDEO BOSS. MAY TANONG LANG AKO, BAKIT HINDI MUNA KINUHA ANG TOTAL LOADS BAGO NAG APPLY NG DF? KASI KUNG ANG REMAINDER AY IMUMULTIPLY 35%DF, MAPAPASAMA ANG LOAD NG ACU SA REMAINDER. PERO SA VIDEO MO, SA 100%DF SYA NAMULTIPLY. TIA
@blankex6087
@blankex6087 3 года назад
yung 1st 3000VA @100% DF and remainder @35%DF ay applicable lang po sa lighting load, C.O./ small appliances load/ laudry circuit. Yung ACU po fixed appliance po siya kaya separate po yung computation niya. sana po makatulong :)
@rogertrimuchaofficial9532
@rogertrimuchaofficial9532 3 года назад
pati ikaw nalilito ahh pag explain
@lucitolabayog2713
@lucitolabayog2713 4 года назад
Ang Labo!
@joyescarletbagayan6619
@joyescarletbagayan6619 4 года назад
boss idol ask ko lang sana kung panu ang singilan sa electrical at kung anu anu ang dapat singilin sa electrical sana matulongan mu aq boss idol thanks and godbless
@sannysorianojrbat-ao8935
@sannysorianojrbat-ao8935 4 года назад
Master anung size pvc or rsc gamitin para sa Lo at CO
@junauxtv
@junauxtv 4 года назад
1/2 sir madalas...pero depende din sa no. Of conductor
@sannysorianojrbat-ao8935
@sannysorianojrbat-ao8935 4 года назад
Salamat sa pag sagot master.. Ok lang na Pag samahin sa isang pvc ang LO CO para dina ako gagawa pa ng saring pvc pang outlet
@junauxtv
@junauxtv 4 года назад
@@sannysorianojrbat-ao8935 no problem sir if tingin mo sir hirap ipasok ang wire pwd ka mag 3/4 sir
@hatchiretchistudio5148
@hatchiretchistudio5148 4 года назад
idol pwede po ba 5.5 mm at 60 amp yung ginamit kong main circuit breaker? Yun po kasi yung nakalagay na load service entrance. kaya po ba yun sa second floor na bahay? Salamat po 🙏
@urstillrighthereinmyheartd7521
@urstillrighthereinmyheartd7521 4 года назад
Master not allowable ang 5.5mm sa 60 amp n breaker maxado na syang malaki bka sunog na ung wire mo hnd pa nagtitrip ung cb mo.ang 60amp ay pra sa size na 14mm/#6 Pag 5.5 dpt 30 amp lng ikaw ung main cb mo.dpt tugma ang breaker mo sa wire mo pra iwas sunog master.
@hatchiretchistudio5148
@hatchiretchistudio5148 4 года назад
@@urstillrighthereinmyheartd7521 salamat po idol sa pag advice, tanong ko lang po idol, pwede po ba dugtungan ng #6 wire yung 5.5 mm wire na galing sa metro po? yun po kasi nkalagay papuntang bahay idol hindi din pwede buksan yung metro 🙏 salamat po idol sa pagsagot 🙏
@jojopenaborja9798
@jojopenaborja9798 3 года назад
Tanong ko Lang po Kong ang main breaker 60A,service entrance ay #6 pano po yon eh ang service drop #8 ok Lang ba yon?paki sagot Naman po.tnx
@junauxtv
@junauxtv 3 года назад
Ok lang yan sir...basta from service entrance papuntang bahay yan ang concern natin sir...si power provider na bahala sa service drop
@ryanmuli0331
@ryanmuli0331 4 года назад
Sir sana po masagot nyo po kc po nagpatayo ako maliit na bahay Meron po 4 na bulb at 6 na outlet Sabi po 30amp na breaker ang ilalagay at ung wire dw po #10 lahat,ok lng po ba un sir,salamat
@junauxtv
@junauxtv 4 года назад
20 amps lang sir..mula breaker papunta sa ilaw at saksakan 3.5mm or no. 12, mula sa source mo sir papunta sa breaker 5.5mm or no.10 sir...
@ryanmuli0331
@ryanmuli0331 4 года назад
@@junauxtv ah cge po sir maraming salamat po
@junauxtv
@junauxtv 4 года назад
@@ryanmuli0331 welcome po sir.. salamat din po
@torcrame4183
@torcrame4183 4 года назад
20AT is sufficient to carry the load. 4pcs x 100W = 400VA ( assuming 100w gamit mo ilaw which is malaki na yan) 6pcs x 180VA/outlet = 1,080VA Total = 1480 VA / 230V = 6.43A
@junauxtv
@junauxtv 4 года назад
Tnx for sharing your thoughts sir...
@mototechtv.3774
@mototechtv.3774 4 года назад
Pangit nmn ng DB ng pinas sunog n mga gamit or bahay dipa nag trip..tsaka di mahigpit ang meralco sa mga klase ng wire at pag wawiring ng mga electrician at di electrician...kaya ang systema magulo...hehe real talk po..
Далее
Я ВЕРНУЛСЯ 🔴 | WICSUR #shorts
00:57
Просмотров 2,4 млн
Wait for the BOWLING BALL! 👀
00:38
Просмотров 21 млн
Tamang Size ng Service Entrance Conductor
17:30
Просмотров 151 тыс.
LOAD SCHEDULE & COMPUTATION
14:25
Просмотров 51 тыс.
Wire Sizing and  Circuit Breaker Ampacity
9:18
Просмотров 216 тыс.
Paano Mag Set Up Ng 2 to 3 Rows Na Distribution Box
24:20
BASIC ELECTRICAL LOAD COMPUTATION
14:21
Просмотров 138 тыс.
Я ВЕРНУЛСЯ 🔴 | WICSUR #shorts
00:57
Просмотров 2,4 млн