Тёмный

Transfer Girder with Floating Column 🔥 | Reinforcement Checking at Site | Hosur | Kavin Associates 

Kavin Associates
Подписаться 108 тыс.
Просмотров 21 тыс.
50% 1

#home #homeconstruction #building #kavinassociates
CONTRACTOR:
Name : Er.Nirmal B.E
Company Name : New Tech Construction
Contact No : 9894837129
He is doing building contract work & interior work in and around hosur & bangalore region. Interested can call the above number for more details...
WATCH OUR LATEST VIDEOS:
Nibav Vacuum Lift For Home 🔥 | Make your Home Luxury 😍 | Complete Tour and Customer feedback 😱 | KA - LINK - • Nibav Vacuum Lift For ...
₹2.15கால் லட்சம்னா சும்மாவா🔥| Live Testing at Site ✅ Using Original Schmidt Live Rebound Hammer - LINK - • ₹2.15கால் லட்சம்னா சும...
WATCH OUR LATEST REPAIR SERIES VIDEOS :
1.Column Strengthening Using Carbon Fiber Wrapping | Repair of Fully Corroded Column | Micro Concrete - LINK - • Column Strengthening U...
2.𝗕𝗲𝗮𝗺 𝗦𝘁𝗿𝗲𝗻𝗴𝘁𝗵𝗲𝗻𝗶𝗻𝗴 𝗨𝘀𝗶𝗻𝗴 𝗖𝗮𝗿𝗯𝗼𝗻 𝗙𝗶𝗯𝗲𝗿 𝗪𝗿𝗮𝗽𝗽𝗶𝗻𝗴 😱 | Beam Cracks Problem Solved ✅ | Kavin Associates - LINK - • 𝗕𝗲𝗮𝗺 𝗦𝘁𝗿𝗲𝗻𝗴𝘁𝗵𝗲𝗻𝗶𝗻𝗴 𝗨𝘀𝗶...
3.வீட்டில் வரும் Wall Dampness-ஐ தடுக்கும் முறை 😱 | 100 % Solution | Repair Series | Kavin Associates - LINK - • வீட்டில் வரும் Wall Da...
4.Terrace Floor-ல் வரும் Cracks, Water Leakage-ஐ எப்படித் தீர்ப்பது ? | PU Injection Method | 100% - LINK - • Terrace Floor-ல் வரும்...
For Business Enquiry, Collaboration & Promotion - WhatsApp me - 9994087571
Camera used for shoot - #iphone13promax
App used for editing - #vneditor & #canva
#youtube #youtubechannel
If you like this video - Like, share and subscribe to my RU-vid channel... LINK - / kavinassociates
Share this knowledge to your friends and learn new things everyday and make your skill stronger...
Follow me - / kavinassoci. .
Like me - / kavin1011
FOR QUERIES & DETAILS: Mail us at - kavinprivin5@gmail.com
#housedesign #homeconstruction #homeideas #construction #building #hometips

Наука

Опубликовано:

 

28 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 97   
@janasanjay1227
@janasanjay1227 Год назад
Very informative sir.... column are cranked opposite to achieve hinge action so that the floating column only allows to transfer axial force and not moment and beams are given sufficient depth to avoid punching failure.
@triaxialcivil1907
@triaxialcivil1907 10 дней назад
Hai sir.. Very interesting topic.. Pls upload a video for eccentric footing
@venkataramananp3915
@venkataramananp3915 4 месяца назад
Excellent, bar bending reinforcement work.
@MrPearllotus
@MrPearllotus Год назад
Very informative and friendly explanation, lovely attitude from engineer. As a civil engineer I feel proud to say your channel is a reference tool for me and your the voice முடியுமே literally sounds energetic and giving confidence towards work 🤝🏼
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
Thank you so much sir 😊 share our videos to your frnds
@MrPearllotus
@MrPearllotus Год назад
@@KavinAssociatesOfficial sure sir 🤝🏼
@SuryaPrakash-tr8yb
@SuryaPrakash-tr8yb 6 месяцев назад
Yes !! Seeing yu both speaking oru spro oduthu mandaikulla😀
@KavinAssociatesOfficial
@KavinAssociatesOfficial 6 месяцев назад
🤗
@gowthamiv2760
@gowthamiv2760 Год назад
அருமை! அருமை!
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
Thank you sir 😊
@arsathayub4890
@arsathayub4890 Год назад
Bro very useful 👍 Please make more like this
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
Thank you sir 😊
@sathiskumars4502
@sathiskumars4502 Год назад
Very Informative video. Thanks for bringing that. Is the building structure also designed for seismic loads along with gravity loads? As per IS1893-part 1-2016, there shouldn't be any vertical irregularities present in the building like floating columns when designing a structure for seismic effect. Please clarify. Thanks
@ilanchezhian7071
@ilanchezhian7071 Год назад
the beam reinforcement is not parallel and its like one end is at the bottom and another end is at the top of transfer girder , can you explain why it was designed in this manner
@ajaymanikaprakash3272
@ajaymanikaprakash3272 Год назад
Transform Girder floting column junction detailing code book and clause number sollunga brother
@srinivasmende-f3i
@srinivasmende-f3i Год назад
Does 2 legged stirrups statisfied for transfer beam
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
Yes it may change as per design
@mohanraj7537
@mohanraj7537 Год назад
🎉 super sir
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
Thank you sir 😊
@eswaransumathi3868
@eswaransumathi3868 Год назад
Subar பிரதர்
@MAHA6690
@MAHA6690 Год назад
super sir
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
Thank you sir 😊
@Pradeep-vl5yf
@Pradeep-vl5yf Год назад
Bro, one doubt. In fixed beam, end and span moments varies but why the reinforcement is same in both top end and mid bottom.
@sonnapuriyaathu
@sonnapuriyaathu Год назад
Thanks bro ❤
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
☺️
@HosurTV
@HosurTV Год назад
nice
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
Thank you sir 😊
@ramajayakumartr8363
@ramajayakumartr8363 Год назад
Hi sir, vaccancy irukkuma sir
@sushmanb2149
@sushmanb2149 10 дней назад
Thank you sir. Show the floating columns on cantilever beam sir
@bharathy8234
@bharathy8234 Год назад
Inspirational video, i never seen practically floating column with transfer girder. Just studied in books. But this video makes lot of sence to me brother. Thank you brother Thank you so much 🎉
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
Thank you sir 😊 share maximum
@jpradeepraj
@jpradeepraj 10 месяцев назад
Hello sir, even in normal columns, joggling is not advisable, but this way of floating column (the X portion) shows extreme joggling, how is this good?
@tejgautham4628
@tejgautham4628 Год назад
Bracket column pathi sonengala bro athu detailed solunga ,,,, torsion design pathi
@karthikrajendran354
@karthikrajendran354 Год назад
(Elevation + plan ) work pannuvingala sir
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
No sir ..we are design company
@karthikrajendran354
@karthikrajendran354 Год назад
tq sir
@venugopalk3276
@venugopalk3276 10 месяцев назад
Very nice 👍
@KavinAssociatesOfficial
@KavinAssociatesOfficial 10 месяцев назад
Thank you sir 😊
@KumarKumar-fo5wt
@KumarKumar-fo5wt Год назад
Super sir
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
Thank you sir 😊
@muruganp6166
@muruganp6166 Год назад
Sir roofla water tank load eppadi kodukkalam
@AjithKumar-sv6kk
@AjithKumar-sv6kk Год назад
Sir BIM concept video make pannunga
@amirthalinkam5104
@amirthalinkam5104 Год назад
Super
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
Thank you 😊
@dhanasekaran3010
@dhanasekaran3010 Год назад
Super Sir👍
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
Thank you sir 😊
@MohamedAlfaiz95
@MohamedAlfaiz95 Год назад
Floating column code Book details
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
IS1893 & IS13920
@hihi-wm9xb
@hihi-wm9xb Год назад
very informataive
@sulochanajeganjegan9655
@sulochanajeganjegan9655 Год назад
🎉 good view
@Prakash_Govindharaji
@Prakash_Govindharaji Год назад
Thank you sir
@chansdcreation
@chansdcreation Год назад
Bro civil engineering student ku design course statt pro, revit course details solluga bro
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
Join our course bro
@chansdcreation
@chansdcreation Год назад
@@KavinAssociatesOfficial details bro
@gowthamiv4841
@gowthamiv4841 Год назад
Haunch bar dia didn't mentioned and as well as secondary beam as well as main beam junction top bars didn't tell the details..
@gowthamiv4841
@gowthamiv4841 Год назад
Can you provide special video in this?
@merrilheysan2089
@merrilheysan2089 Год назад
Very Valuuable information bro........ Thank you so much......
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
Thank you sir 😊
@AlaguVignesh
@AlaguVignesh Год назад
Floating column in transfer grider details - which code book ? Kindly mention
@AjithKumar-sv6kk
@AjithKumar-sv6kk Год назад
Sir which software you use in reinforcement design?
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
Staad & RCDC
@ganapathycivil9872
@ganapathycivil9872 Год назад
Vera level video sur, thanks a lot and post a lot 😅❤
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
Thank you sir 😊
@muruganp6166
@muruganp6166 Год назад
Very useful video for me thank you sir rompa nantri
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
Thank you sir 😊
@sudhakars9222
@sudhakars9222 Год назад
Informative sir. Wondering about 4 floors column load carried by single beam. Need any side face reinforcement above 2 feet depth of beam sir?
@rajubhaibangbang
@rajubhaibangbang Год назад
VIP DHANUS MARRIYE THUMBNAIL
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
☺️ Thank you sir 😊
@mgtech7432
@mgtech7432 Год назад
Very good explanation sir* heartly thanks 👌
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
Thank you sir 😊 share maximum
@PraveenKumar-cc3fs
@PraveenKumar-cc3fs Год назад
Sq.ft evlo sir pandringa intha project😮
@GamingLoozer
@GamingLoozer Год назад
8:45 Minimum & maximum evvalavu Space kulla veikka ealum?? ( Feet )
@prabinjebav3928
@prabinjebav3928 Год назад
Sir, cantilever beam oda rod ku development length neeti vidaama ata end la just 'L' mattum Pani vidurathi recommended method thana
@manjumist2635
@manjumist2635 Год назад
Verum 2L ring mattum potrukanga..?
@davidsahayaraj8811
@davidsahayaraj8811 Год назад
Nice and useful information 🤝
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
Thank you sir 😊 share maximum
@reojoan1546
@reojoan1546 Год назад
Whats IS code for transfer girder sir?
@sakthivels9574
@sakthivels9574 Год назад
👍 super bro
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
Thank you bro ☺️
@ManiGandan
@ManiGandan Год назад
Plan show us
@nvdhamodaranrc8637
@nvdhamodaranrc8637 Год назад
Suprb sir
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
Thank you sir 😊
@shieksspace
@shieksspace Год назад
4:56 is that concept of moment release on secondary beams ?
@atifnawaz7623
@atifnawaz7623 Год назад
No. that is normal detailing when secondary beam meets a main beam.
@larulprakash5952
@larulprakash5952 Год назад
Super sir , good explanation 👍
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
Thank you sir 😊
@mohammedismail-lx2dq
@mohammedismail-lx2dq Год назад
Rombanaal kku apm naala civil channel❤❤❤❤
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
Thank you sir 😊
@chinnappasconstruction0809
@chinnappasconstruction0809 Год назад
hlo Mr.kavin. transfer girder ku pathila an PT beams use pannalaama? athu helpfull ah irukkuma
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
Yes you can
@chinnappasconstruction0809
@chinnappasconstruction0809 Год назад
what the economical difference between both two types?
@saravanan.engineer3630
@saravanan.engineer3630 Год назад
Useful one sir
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
Thank you sir 😊
@srishanmugaconstruction584
@srishanmugaconstruction584 Год назад
Useful information 👍🏻👍🏻👍🏻👍🏻
@KavinAssociatesOfficial
@KavinAssociatesOfficial Год назад
Thank you sir 😊
Далее
Дикий Бармалей разозлил всех!
01:00
FATAL CHASE 😳 😳
00:19
Просмотров 1,1 млн