Тёмный

Trial Mix Design of M40 Concrete on Site | Live From Site | Walk through 

Civil Engineer Deepak Kumar
Подписаться 1,4 млн
Просмотров 26 тыс.
50% 1

Trial Mix Design of M40 Concrete on Site
Share, Support, Subscribe!!!
Twitter: / erdeepak4kumar5
Facebook: / er.deepak4kumar5
Facebook page: / er3deepak4kumar5
Instagram: / er.deepak4kumar5
Pinterest: / erdeepak4kumar5
Tumblr: www.tumblr.com...
StumbleUpon: www.stumbleupo...
RU-vid: / erdeepakkumar
#TrialMix #DesignMixM40 #SlumpTest

Опубликовано:

 

6 окт 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 34   
@bvsnagababu7954
@bvsnagababu7954 3 года назад
Sir How we know that how much amount of admixture is replaced with water
@animeshbhattacharyya2073
@animeshbhattacharyya2073 Год назад
did you check the flakei material % of your coarse aggregate Please chek and maintain the limit, you will get the workibility benefit /water reduction benifit/ strength criteria benifit thanks
@chhayakantanaik9468
@chhayakantanaik9468 5 лет назад
Sir Can u please make a video on difference between Nominal mix and design mix...
@CivilEngineerDeepakKumar
@CivilEngineerDeepakKumar 5 лет назад
ok I will make video on this topic
@CivilEngineerDeepakKumar
@CivilEngineerDeepakKumar 5 лет назад
thanks for watching
@chhayakantanaik9468
@chhayakantanaik9468 5 лет назад
Thank you sir!!!
@padmeshjain1778
@padmeshjain1778 5 лет назад
Mr. Deepak, 20 kg cement is right quantity for 0.03 M³ concrete.
@shashankshekhar8419
@shashankshekhar8419 4 года назад
Galat h
@sunilkumarchaursiya4295
@sunilkumarchaursiya4295 4 года назад
Sir trail mix karne ke lie 0.025 cum material lete hai ye kaise lia jata hai aur kaise pata karenge ki sand agg and cement kitna kg lena hai
@creativepk0526
@creativepk0526 5 лет назад
Sir base slab k liye 40 mm aggregate k sath base concrete ka mixture ky hoga
@CivilEngineerDeepakKumar
@CivilEngineerDeepakKumar 5 лет назад
10mm & 20mm
@ashishtrivedi6426
@ashishtrivedi6426 3 года назад
Deepak. My Contractor prefers 1:3:3 for column fitting 1:2:3 for colum which grade will it fall in
@Bijoy4
@Bijoy4 3 года назад
For column use 1:1.5:3 mix
@pranavkumar9785
@pranavkumar9785 4 года назад
Sir , Plz reply to my comment , My question is , yeh 160mm slump requirement me 105 aaya phir toh pumpable concrete nahi bana , admixture use krte hue v , av is situation me kaise kaam kiye phir aap?
@moizsalah4963
@moizsalah4963 3 года назад
Where it is mentioned 160 mm slump for M40 grade..IS code book???
@sivajikodali8759
@sivajikodali8759 2 года назад
The concrete looks like coarser and there we can observe surface bleeding and there is no flow in it soo.
@bijoypal1088
@bijoypal1088 4 года назад
Sir mixer ko kitne time tak ghumana hey ?
@erhardikmistri
@erhardikmistri 4 года назад
Sir can u help me plz u have available this mix design full calculation ?
@vishwajitsen8440
@vishwajitsen8440 5 лет назад
आपने इसमें अगर desired compressive strength तथा slump नहीं आया तो क्या करना चाहिए नही बताया
@CivilEngineerDeepakKumar
@CivilEngineerDeepakKumar 5 лет назад
watch my this video for this ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-ScjYqv2p3Ac.html
@faizanalam3313
@faizanalam3313 4 года назад
Sir isme two size ka aggregate kiyo use kiya gya h M20&M10
@pranavkumar9785
@pranavkumar9785 4 года назад
Aggregate ka size mm me hota hai aur maximun size ko leke mix design hota and usse kam size walo ko kam ratio me rakh k use kara jaata , avi is case me 60% 20mm agg use kiye h toh 40% 10 mm ka .
@alizeeshanhashmi4355
@alizeeshanhashmi4355 4 года назад
Which admixture is used ??
@CivilEngineerDeepakKumar
@CivilEngineerDeepakKumar 4 года назад
cryso
@CivilEngineerDeepakKumar
@CivilEngineerDeepakKumar 4 года назад
rapid hardening
@shiten7617
@shiten7617 4 года назад
Many segregation found in mix. not acceptable
@DEEPAKkumar-rd6ey
@DEEPAKkumar-rd6ey 5 лет назад
Sir,if I want to do project in this topic.could you please suggest me how to do project???
@CivilEngineerDeepakKumar
@CivilEngineerDeepakKumar 5 лет назад
yes email me
@DEEPAKkumar-rd6ey
@DEEPAKkumar-rd6ey 5 лет назад
Plz suggest me sir
@DEEPAKkumar-rd6ey
@DEEPAKkumar-rd6ey 5 лет назад
Sir suggest me for project on concrete mix design
@creativepk0526
@creativepk0526 5 лет назад
Sir aapne 40 mm aggregate to liya hi nahi
@CivilEngineerDeepakKumar
@CivilEngineerDeepakKumar 5 лет назад
40 mm use nahi karna hai this design is for Slab
@palashjana9647
@palashjana9647 4 года назад
Mix cohesive nahi tha
@9030391964
@9030391964 Год назад
Mix is having saggregation I think.. workability is low.
Далее
CONCRETE MIX RATIO 1:3:3 JOB MIX
6:26
Просмотров 101 тыс.
Bro's Using 3 Weapons
00:36
Просмотров 3,8 млн
This mother's baby is too unreliable.
00:13
Просмотров 23 млн
Concrete Mix Design | Part-01 | Technical Civil
11:59
Просмотров 296 тыс.
Does Rebar Rust?
7:49
Просмотров 4,6 млн