@srbontrager
@srbontrager 5 месяцев назад
This was exactly how my Tripac Evolution APU was behaving. Didn't even bother fiddling around with the computer. Just checked the fuse you pointed out, and yep, that was the problem. Blown fuse for the APU radiator fan. I install a fresh 15 amp fuse from my stash of spare fuses and it works like it's supposed to.
@dell7054
@dell7054 2 года назад
u bet the dealership probally wanted 1k lol
@paule5539
@paule5539 2 года назад
Thank you from my wife and I... I just fixed my apu and saved a ton of money from this video..my fuse was popped
@龙-g3q
@龙-g3q 4 месяца назад
I lost the lid that opens on the box, where can I buy it separately? I looked on ebay and couldn’t find it, can anyone tell me?
@txkid123
@txkid123 2 года назад
You just saved my bacon! Unit would run until hot then cut off. Pulled the fuse cover and found the fuse blown. Will sleep good tonight. Thank you
@Ryanmatthewseltzer
@Ryanmatthewseltzer 2 года назад
I can’t thank you enough I swapped the fan nothing I check this fuse and boys she’s happy now
@salvatorelicata8768
@salvatorelicata8768 3 года назад
Dude you are the shit. No bullshit. You are a life saver man. THANKS
@enochtesfai1600
@enochtesfai1600 2 года назад
You saved me a lot of $$$. Thank you so much!. Same error code on my APC. I did not even check the fan. I looked at the fuse you discussed and there it was. Changed the fuse and APU running as good as new. Thank you!! If you were near me I would have kissed you!
@jamesritter3143
@jamesritter3143 3 года назад
Who doesn't have problem with a tripac ??, am I right huh ? Huh? J/k thanks for the info
@jamesritter3143
@jamesritter3143 3 года назад
How did u make out? Did the fuse blow again? In my experience if a fuse blows it will again . Usually do to a rubbed thru wire somewhere shorting the fuse out. Let me know thanks
@Stevielinguine
@Stevielinguine 3 года назад
I am noticing that i have to smack the fan assembly under the bunk to get air to start blowing again. Once the air starts to blow, its nowhere near as hard and only lasts for around 20 to 30 minutes, as the airflow slowly decreases, until it stops blowing again. Please advise?
@mikekabli817
@mikekabli817 3 года назад
Nice video bro To test the fan you can also supply 12v to it from a small battery to the terminals and it should spin if it's good if bad nothing will happen
@michaelbritton2331
@michaelbritton2331 2 года назад
windows 7 will work with tripac evolution USB to mini b cable
@MrBorri007
@MrBorri007 2 года назад
Hey buddy great video but on that software you can test the two fans I had the same problem it was the temperature sensor on the water pump
@temoaguil1830
@temoaguil1830 5 месяцев назад
Were is the temperature sensor?
@bubzorg
@bubzorg Год назад
Thanks Bro. ✊ This was my problem and now it’s fixed after buying a cheap TA ratchet set and a 15 amp fuse.
@bigbluenationsmith2489
@bigbluenationsmith2489 3 года назад
That’s the same problem I’m having. Let me go check it out now that I have an idea. Thank you for the information. By the way are you a veteran? I have some Army buddies that could be your twin.
@cashdala4163
@cashdala4163 Год назад
❤just fixed mine yup fuse was blown ty brother
@r0adwarri0r90
@r0adwarri0r90 2 года назад
Thanks man. Mine wouldn’t let me see the codes until I found a link to download the file from thermoking from another video
@glackaglack1534
@glackaglack1534 3 года назад
You of to be specific what type of laptop required . Laptop of to have windows 7
@almir7821
@almir7821 2 года назад
But how you connect your thermo king with the laptop then they show you all history you put some unit number or something
@rayon9238
@rayon9238 5 месяцев назад
Lol 😂thanks man it work blue fuse
@sim529
@sim529 3 года назад
Thank you for great video. Where do you get the software?
@truckercamionero846
@truckercamionero846 3 года назад
He said you don't need to have any software, just plug in the cable and the software will come up from the motherboard.
@nickkamaloff5631
@nickkamaloff5631 3 года назад
Mine says no active alarms. Idk what to do now. But i been getting the same code as urs
@J.A_52259
@J.A_52259 Год назад
Thank you Very much brother appreciate you
@yourbestpic2
@yourbestpic2 Год назад
All had to do was open the hood to let it cool down and it works great.
@janiceneal2965
@janiceneal2965 Год назад
Thank you, your video helped me avoid a trip to Thermo King
@wd2862
@wd2862 3 года назад
Thank you for the information, you helped me a lot. Thank you.
@truckercamionero846
@truckercamionero846 3 года назад
Excellent video and better explanation, thanks a lot brother
@PeterTopov
@PeterTopov Год назад
Right on the money!! Thank you!
@erdincyilmaz4688
@erdincyilmaz4688 Год назад
excellent job 👍
@krubruder1121
@krubruder1121 3 года назад
Thanks. That helped.
@odairtaveira5675
@odairtaveira5675 2 года назад
I was looking for this software! Thank you for your information about it !
Далее
Лучше одной, чем с такими
00:54
Просмотров 654 тыс.
Teeth gadget every dentist should have 😬
00:20
Просмотров 1,6 млн
Tripac apu issues
7:17
Просмотров 3 тыс.
Thermoking Tripak Apu Troubleshooting
5:41
Просмотров 71 тыс.
Apu Tripac Evolution Radiator Fan Replacement
21:37
Просмотров 2 тыс.
APU Tri-Pac yellow red triangle
4:32
Просмотров 7 тыс.
How To Fix Thermo King APU High Coolant Temp
6:49
Просмотров 1 тыс.
THERMO KING "ACS" APU LIGHT CAME ON AND FIX