AprilAire Partners Training - Unboxing and Installing the AprilAire Model 600 Whole-Home Evaporative Humidifier, designed and manufactured in the USA by AprilAire
Learn how to unbox and install the AprilAire Model 600 Whole-Home Evaporative Humidifier on site for your customers and provide humidity control for healthier air this year with AprilAire. With the Model 600, you’ll be providing these benefits for your customers’ homes.
FULL COVERAGE up to 4,000 square feet in tightly built homes with a capacity of 17 gallons per day
AUTOMATIC HUMIDIFIER with dual sensors to monitor and respond to both outdoor temperature and indoor relative humidity to deliver optimum humidity 24/7 throughout the home - your customers can simply set it and forget it
CONVENIENT DIGITAL CONTROL shows percent humidity while lights indicate humidifier is running, when to change the water panel, when service is needed, and the Blower Activation switch sets humidifier to run continually, or only when the furnace runs
HUMIDITY FOR HEALTH with AprilAire humidifiers can help you maintain optimal humidity in your customers' homes between 30% and 60% which has been shown to reduce the incidence of respiratory infections and symptoms related to allergies and asthma by minimizing the formation of bacteria and viruses, fungi, and dust mites. In addition, your customers will feel more comfortable while also preserving items in your home susceptible to damage from changing humidity or dry conditions
Included in the box: Installation instructions and template, humidifier with built-in bypass damper, 24 VAC transformer, automatic digital humidifier control with sensor, outdoor temperature sensor, saddle valve, solenoid valve, and water panel.
Visit www.aprilairep... to learn more or call us today at 1-800-334-6011.
Correction: The form number for the magnetic template mentioned at 4:19 is Form #272.
Disclaimer: This training video is intended for HVAC contractors, distributors, and home builders only, and should not be referenced by homeowners themselves.

Опубликовано:

 

14 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 135   
@KamoNova
@KamoNova 3 года назад
Make sure your control device is level. Don’t worry about hooking up the water supply or wiring up for power.
@ChronicKPOP
@ChronicKPOP 2 года назад
we don't want power, we just want a good level control panel. Not too much to ask.
@claudea79
@claudea79 2 года назад
One of the best pro videos that I have seen; very well explained and narrated!
@aprilaireco
@aprilaireco 2 года назад
Thank you for your feedback, Claude!
@jonlynch6821
@jonlynch6821 4 года назад
I thankfully found this video while looking for how to videos for my new Aprilaire 500. We decided 20 years was a good run for the previous 550 model. Installation was very simple, since I had a previous setup. Thanks for posting!
@garywebster8476
@garywebster8476 2 года назад
Yea
@duarterodrigues5185
@duarterodrigues5185 Год назад
Well done thank you so much
@peanutbutterisfu
@peanutbutterisfu 3 года назад
To the people I’ve seen leave negative reviews because this system doesn’t come with everything to install it this is just like most everything you buy for a house it’s a universal fit there is no was they could possibly know what parts are needed to install it in your house. No 2 houses are the same. If they did give you every possible part you need to install this kit you would be paying hundreds of dollars more. On average you should plan on spending 100 bucks to buy the parts you need to install this kit. Don’t blame the company because you didn’t do any research and not for nothing with you tube it takes 10 minutes to figure out what you need.
@bazaf3andimangoul-iy7dy
@bazaf3andimangoul-iy7dy 7 месяцев назад
👍 Thank you so mutch
@richardmitchell5129
@richardmitchell5129 4 года назад
Would be nice to have someone that used the snips correctly and didn't leave a wavy edge and meat hooks, I know that is knit picking sorry. Also it would be nice if you actually wired it. I know there are a lot of ways to do this old equipment versus new equipment. love the magnetic template. love Aprilaire products.
@aprilaireco
@aprilaireco 4 года назад
We appreciate your feedback, Richard - thank you for your comment. We're glad to hear you love Aprilaire!
@pavlo687
@pavlo687 4 года назад
I have a young man at Aprilaire today 2/12/20 tell me that I needed to cut out a square (about 4.3 x 2.5) for the control panel to mount into! Someone needs to talk to him and straighten him out! I see now (because I thought something wasn't right) that I only need a 3/4" hole for the sensor! Thank goodness my antenna were working today.
@independentmind1977
@independentmind1977 4 года назад
I've actually seen a couple of videos where the installer cut out the square. Personally I'm just doing the small hole for the sensor, no need for the extra work and chance air leaks.
@allanzakaria
@allanzakaria 3 года назад
I think thats only if you have the manual control
@mariemlina9900
@mariemlina9900 5 месяцев назад
bon produit mais, dommage je peu pas l'installer chez nous , parce que j'ai seulement des conduite d'échangeur d'air.
@rizwanrafeek3811
@rizwanrafeek3811 6 месяцев назад
I installed this in my home, I noticed airflow leaks out through edge of closing front panel, so I have to aluminum tape around it. And the water-drip grill does not stay in or lock in, it has tendency to lean to the front panel which will result in water leaking through the edges. The bottom water drain hole water leaks too. This thing has full of issues.
@aprilaireco
@aprilaireco 6 месяцев назад
Thank you for contacting AprilAire. We’re sorry to hear of the issues you have been having with your Model 600 Humidifier and would like to offer our assistance. Leaking can be caused by an obstruction of water flow or when the components within the humidifier are not firmly in place and level. If you would like to discuss this further over the phone, we can be reached at 800-334-6011, Monday through Friday, 7:00 a.m. to 5:00 p.m. CT. One of our technicians would be happy to discuss more with you over the phone. Thank you for the opportunity to be of assistance; AprilAire appreciates your business.
@cyberlando
@cyberlando 6 месяцев назад
What wire configuration should I use to make sure my humidifier doesn’t come on with the ac compressor? I just want it on with the furnace in the winter.
@aprilaireco
@aprilaireco 6 месяцев назад
Thank you for contacting AprilAire! Would you mind giving us a call at 800.334.6011? We would be happy to walk through this with you in detail. We will need to know which controller you are using. A team member is available at the number above Monday through Friday, 7:00 a.m. to 5:00 p.m. CT. Thanks again for contacting AprilAire!
@juno481
@juno481 6 месяцев назад
My humidifier green led light does not stay on. I have done reset several times, letting the led blink 60 times, then turning the dial to 4 or 5. Led stays on for half hour or so then turns off. It does not light up again when the heater turns on. What am I doing wrong here? Please help. Thank you
@aprilaireco
@aprilaireco 6 месяцев назад
Thank you for contacting AprilAire! Could you please give us a call so we can walk through possible causes and discuss further? We can be reached at 800.334.6011 Monday through Friday, 7:00 a.m. to 5:00 p.m. CT. Thanks again for contacting AprilAire.
@brikkman4700
@brikkman4700 4 года назад
WELLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLLL. you forgot a very important step that was listed on the sheet as step 9 and completely left out the video.... THE DRAIN LINE................. All that water dripping on your floor can not be a good thing... Should I get a reward or something? lol
@aprilaireco
@aprilaireco 4 года назад
Thank you @brikk man. The drain is extremely important and will be addressed.
@OscarHanzely
@OscarHanzely 3 года назад
Just call them, and laugh at them like they would laugh at you if you leave it in Test Reset mode ;-)
@andersod1060
@andersod1060 Год назад
The water into the pad is flowing continuously. I've removed the unit to replace the valve and removed the copper pipe going into the valve and also the plastic pipe going into the top of the water pad. I notice there is a small yellow restrictor plug in the end of the tube going into the valve. I assume this restrictor plug is to reduce the water flow to three gallons per hour. What would be the results of removing the restrictor plug to increase the water supply to the filter? Wouldn't removing the plug increase the humidity in the home?
@LouisWilen
@LouisWilen Год назад
The yellow plug is a a metering orifice. If you remove it, the humidifier will immediately overflow and leak. Also, never try to clean the hole in the orifice with anything other than water. Enlarging the hole by even a few microns will cause the humidifier to overflow and leak.
@Sunsettrails1
@Sunsettrails1 4 месяца назад
is it ok to use the "W" and "c" terminals on the control board for power?
@aprilaireco
@aprilaireco 4 месяца назад
Thank you for contacting AprilAire! The control needs 24 Volts when the heat is running. We advise connecting to the hum and C terminals as those are outputting 24 Volts specifically for a humidifier. W and C are technically not outputting it for the function of the humidifier and more for the furnace operation. We would be happy to discuss this further and can be reached at 800.334.6011 Monday through Friday, 7:00 a.m. to 5:00 p.m. CT.
@charlieheath8342
@charlieheath8342 4 года назад
I have a two wire thermostat and the wires in the oil burner blower are not well labeled. I can get access to the two thermostat wires, and can run the outdoor sensor for automatic thermostat, and wire the transformer. If necessary I can get a current sensor ( wow, those things are expensive! ). I do have access to screw terminals in the fan controller though they are unlabeled. Can you give instructions for how to approach this? This is for an automatic control ( manual is for model 60 & 62) with a new Aprilaire 400. Thanks
@aprilaireco
@aprilaireco 4 года назад
Hi Charlie - If you could give us a call directly at 1-800-334-6011 at your earliest convenience, we'll be able to assist you with this. Thank you!
@davidlewis7348
@davidlewis7348 3 года назад
Can it be installed on the return air side ? If the water panel gets plugged water intrusion would be less likely to damage the furnace.
@aprilaireco
@aprilaireco 3 года назад
Hi David - Thank you for contacting Aprilaire! The Model 600 humidifier can be installed on either the supply plenum or cold air return of a forced air handling system with right-hand or left-hand bypass duct connections. If you have any additional questions, we'd be happy to assist.
@murc111
@murc111 4 года назад
This unit comes with a transformer...Why? Don't you just get the 24v from the furnace?
@aprilaireco
@aprilaireco 4 года назад
Great question. This is included for situations where you can not connect into the furnace.
@ptg01
@ptg01 4 года назад
@@aprilaireco Curious... under what circumstances would you not connect the 24V from furnace control board to the humidifier ?
@aprilaireco
@aprilaireco 4 года назад
@@ptg01 If you could give our Healthy Air team a call directly at 1-800-334-6011, we'd be happy to help you with this. Thank you!
@Practicing_HVACR
@Practicing_HVACR 3 года назад
Transformers have a VA rating to them. They’ll fail if they have too much current moving through them. It’s possible that your current transformer is unable to support the extra equipment.
@avetsuper6272
@avetsuper6272 3 года назад
what about how to connect wires to furnce electric panel ?????
@aprilaireco
@aprilaireco 3 года назад
Hello! Thank you for contacting Aprilaire. If you could give us a call directly at 1-800-334-6011, we'd be happy to address your questions.
@davidkettell1073
@davidkettell1073 8 месяцев назад
What size cutout do i need to put in my plenum to install this unit ?
@aprilaireco
@aprilaireco 8 месяцев назад
Thank you for contacting AprilAire! The Model 600 uses a 10”W x 12-3/4”H plenum opening. If you have any additional questions, we would be happy to assist.
@minhducvo2635
@minhducvo2635 2 года назад
For the ADHC input G terminal, the instruction it says I need to connect to thermostat G but my thermostat G connects to my Furnace G so it is ok to connect ADHC input G terminal and ADHC output Gf terminal directly to my Furnace G ?
@aprilaireco
@aprilaireco 2 года назад
Thank you for contacting Aprilaire! Would you mind giving us a call to discuss wiring? We would be happy to talk through this and point you in the right direction. We can be reached at 1-800-334-6011 Monday through Friday, 7:00 a.m. to 5:00 p.m. CT.
@georgegrace7907
@georgegrace7907 4 года назад
It looks like the connection to the water line was left out either hot or cold and drain line.
@shhallsa
@shhallsa 4 года назад
can use hot or cold, Aprilaire claims hot water is better. d Drain it to floor drain or condensate pump
@soltannorozi6784
@soltannorozi6784 4 года назад
You are great!
@pnull
@pnull 3 года назад
This video is all about the installation. That's fine, but my question is: What about the results when you start using it. I've heard these whole home humidifiers help a little when using a forced hot air heating system, but they don't make a big difference. I would love to get some opinions on this. I can't take that dry air in the winter that emanates from forced hot air heating systems. Thanks.
@aprilaireco
@aprilaireco 3 года назад
Hi Peter - Thank you for contacting Aprilaire! An Aprilaire whole-home humidifier will help with the dry air you reference experiencing as it introduces moist air into the home with the help of the heating system. The Model 600 can service very loose homes up to 1,000 square feet, average homes up to 2,000 square feet, and tight homes up to 4,000 square feet. These numbers are based on the following conditions for your reference: (1) 20°F and 70% RH Outside Air; (2) 70°F and 35% RH Room Air; (3) Internal Moisture Gain of 1 lb/hr; (4) 70% Blower Operation; and (5) 8-foot Ceiling Height. We would be happy to discuss this further and can be reached at 1-800-334-6011 Monday through Friday, 7:00 a.m. to 5:00 p.m. CT.
@eugeneshcherba1613
@eugeneshcherba1613 2 года назад
Where can I find any video about maintenance of Aprilaire Model 240 ? It is quite old unit and I could not find any video about it on youtube.
@aprilaireco
@aprilaireco 2 года назад
Hi Eugene - Thank you for contacting Aprilaire! Would you mind giving us a call at 1-800-334-6011 or reaching out to us via email at support@aprilaire.com? We would be happy to assist with maintenance instructions for your unit.
@eugeneshcherba1613
@eugeneshcherba1613 2 года назад
@@aprilaireco Thank you. I sent email. Perhaps somebody can give me helping hand. Especially how to open it.
@chadcurrent1645
@chadcurrent1645 4 года назад
My furnace has a A/C coil box on top of it. On top of the coil box It's L shaped plenum turning to the left. It's 14" high and 14" wide 24" deep. It has an 8" duct leaving the back to feed a bathroom and bedroom. The main plenum runs along the floor to feed the rest of the house. Return is right next to it. Do you think it would work properly in the 14x14 area above the A/C coil box?
@chadcurrent1645
@chadcurrent1645 4 года назад
Oh yea I installed my furnace myself back in 1999 then installed the Air conditioner and coil box in 2000. I just had a friend solder and vacuum check the lines as I didn't have those tools. So I do have mechanical abilities.
@aprilaireco
@aprilaireco 4 года назад
Hi Chad - If you could give our Healthy Air team a call directly at 1-800-334-6011, that would be great. We'd be happy to address this with you. Thank you!
@DblClkThatShi
@DblClkThatShi 3 года назад
i think i have a bad transformer, the water solenoid is not operating, everything else seems to be working fine, is there a work around?
@aprilaireco
@aprilaireco 3 года назад
Thank you for contacting Aprilaire. Would you mind giving us a call to discuss this? We can be reached at 1-800-334-6011.
@DuyDepTraiPhoBaTrieu
@DuyDepTraiPhoBaTrieu Год назад
I am here because I am more worried about the power connecting part. Video did not show that part at all.
@aprilaireco
@aprilaireco Год назад
Thank you for contacting AprilAire! Would you mind giving us a call at 800-334-6011? We would be happy to assist you with this.
@gageihm52
@gageihm52 2 года назад
I recently had a new hvac system installed but after seeing this video, I noticed that my Aprilaire humidifier is installed in the return duct and not the supply duct, as well as the control. Is that an acceptable placement or should it be relocated?
@christobar
@christobar 2 года назад
It's fine on the return, it's just slightly less efficient. Control should be on the return.
@mattkhomsi
@mattkhomsi 3 года назад
Thank you for this video. My 600 control panel looks older. Inside it has a bypass / power switch. It’s currently set to bypass, should that be flipped to power? I can’t find anything in the manual. Thanks!!
@aprilaireco
@aprilaireco 3 года назад
Thank you for contacting Aprilaire! Would you mind giving us a call directly to discuss this? We'd be happy to help. We can be reached at 1-800-334-6011.
@absolute7250
@absolute7250 6 месяцев назад
Does anyone know the width of the box minus the round duct opening
@aprilaireco
@aprilaireco 6 месяцев назад
Thank you for contacting AprilAire! The product dimensions are 15.38" (width) x 15.75" (height) x 10.25" (depth). These dimensions are the Model 600 itself only and do not reflect the box it comes in. Does this answer your question? If you have any further needs, we would be happy to assist.
@absolute7250
@absolute7250 6 месяцев назад
@@aprilaireco I’m looking for the width of the base of the humidifier. Not including the round part to the attachment of the round duct.
@aprilaireco
@aprilaireco 6 месяцев назад
@@absolute7250 Thank you for your follow up. The base will use a plenum opening of 10” x 12.75." The base itself is roughly 12" wide and 17" in length. If you have any further questions, feel free to contact us at support@aprilaire.com or by calling 800-334-6011. Thank you for the opportunity to be of assistance; AprilAire appreciates your business.
@victorvek5227
@victorvek5227 3 года назад
Is it true that the manual version is more robust and lasts longer than the automatic version of the 600?
@aprilaireco
@aprilaireco 3 года назад
Hi Victor - Thank you for contacting Aprilaire! The manual control is a much simpler humidistat, but it has more restrictions on it. This control will only operate the humidifier when the furnace is producing heat, which limits how often the humidifier can run. The automatic control has more features for optimal control over the humidity in your home. This control will allow the humidifier to operate the furnace fan if there is a need for humidity. If you have any additional questions, we'd be happy to assist.
@fortunatedad7695
@fortunatedad7695 Год назад
Does the unit have to be installed on the return duct or the supply? In theory it shouldn't matter should it? Thanks
@aprilaireco
@aprilaireco Год назад
Thank you for contacting AprilAire! The Model 600 can be installed on either the supply plenum or cold air return of a forced air handling system with right-hand or left-hand bypass duct connections. The humidifier dimensions and serviceability must be considered when selecting the best location for the humidifier. Find an AprilAire Healthy Air Professional nearest you to get started at www.aprilaire.com/find-a-pro. If you have any questions, we can be reached at 1-800-334-6011 Monday through Friday, 7:00 a.m. to 5:00 p.m. CT.
@pilotdog68
@pilotdog68 Год назад
@@aprilaireco does this apply to the 500m as well?
@aprilaireco
@aprilaireco Год назад
@@pilotdog68 Thank you for contacting AprilAire. Yes, that is correct. The Model 500 and 500M can be installed on either the supply plenum or cold air return of a forced air handling system with right-hand or left-hand bypass duct connections. If you have any additional questions, we would be happy to assist.
@user-ho1wl1fg8v
@user-ho1wl1fg8v 8 месяцев назад
Where is the R & C in the furnace?
@aprilaireco
@aprilaireco 8 месяцев назад
Thank you for contacting AprilAire! The R and C would be located in your HVAC system near your other wiring terminals. Industry standard wiring terminals would utilize R,C,W,Y and G. You may need to contact your HVAC company to determine where they are located. Thanks again for contacting AprilAire.
@scottbadgley3718
@scottbadgley3718 3 года назад
Do you have any videos showing how to connect to an Ecobee4 and NOT use your control panel/sensor?
@aprilaireco
@aprilaireco 3 года назад
Hi Scott - We'd be happy to talk through any questions you may have on installation. Would you mind giving us a call directly at 1-800-334-6011? Thank you!
@markreyes2354
@markreyes2354 3 года назад
What if you don’t have humidifier at your furnace. What will happen to you your home?
@aprilaireco
@aprilaireco 3 года назад
Hi Mark - Thank you for contacting Aprilaire. Could you give us a call directly at 1-800-334-6011? We'd be happy to address your questions!
@perrylund4889
@perrylund4889 2 года назад
Do you need an outdoor sensor for Aprilaire to work properly? Also, does it matter what side you install the unit on? ( Return or Heat side?
@aprilaireco
@aprilaireco 2 года назад
Thank you for contacting Aprilaire! The Model 60 and 62 automatic humidifier controls need an outdoor sensor to run in automatic mode. Without one, they will run in manual mode. Automatic mode will just automatically adjust the called for humidity level based on the outside temperature to keep moisture from forming on the windows. Bypass humidifiers (Models 400, 500, and 600) can be installed on the return or supply. With the Model 700, we prefer it to be installed on the supply, but it can be installed on the return if hooked up to hot water. The Model 800 can be installed on either side. If you have any additional questions, we would be happy to assist!
@perrylund4889
@perrylund4889 2 года назад
@@aprilaireco ok, here is another question? If it is hooked up to the return side, does the ( mist/moisture) go through the furnace filter? If so, don't that restrict the flow of the mist? And does the filter get a shorter life span?
@aprilaireco
@aprilaireco 2 года назад
@@perrylund4889 Thank you for your patience here! The humidity does flow through the filter, but it does not affect the filter or impede the moisture in any way. Since the water is actually evaporated rather than throwing water droplets into the air, it does not affect any filters. If you have any further questions, we are happy to assist.
@deathntaxeset
@deathntaxeset 3 года назад
So my customers units are in the attic, along with them having flex duct. He wants 2 installed. 10,000 square foot home. How many square feet of indoor home can 1 unit satisfy? Will i need to create hard-duct to mount this? T-stat wire will now go to this rather than to the air handler, and then from the aprilaire stat to the Air handler? Is the damper able to be controlled by the aprilaire stat? Seems you toggled it manually. You said H H is the solenoid control output, where does the wire travel from and to for H H?
@aprilaireco
@aprilaireco 3 года назад
Thank you for contacting Aprilaire. Would you mind giving us a call directly to talk through these questions? We'd be happy to assist. We can be reached at 1-800-334-6011.
@deathntaxeset
@deathntaxeset 3 года назад
@@aprilaireco i did. Scheduled a call back even. When you called me it was an automated vm asking to Schedule another call back lol
@aprilaireco
@aprilaireco 3 года назад
@@deathntaxeset We will be back in touch with you over the phone as soon as possible. Thank you!
@deathntaxeset
@deathntaxeset 3 года назад
Ok its been over a week now. I've left voice-mail, scheduled call backs, emailed you,... Are you people even a real company???
@aprilaireco
@aprilaireco 3 года назад
@@deathntaxeset Thank you for circling back to us here. We are incredibly sorry for the delay. We are reconnecting with our support team now on this end to get this resolved. We want to ensure that they have the correct contact information for you as well. Would you mind sending us a private message on either Facebook or Instagram with your telephone number? We can be reached on Facebook at facebook.com/aprilaire or on Instagram at instagram.com/aprilaireco/.
@EugeneEstavillo
@EugeneEstavillo 2 года назад
Hi, do you need to connect the ODT wires to enable automatic mode. My humidifier has been installed in manual mode but it is the 600 model not 600M. Can I simply switch it to automatic mode via the internal switch?
@aprilaireco
@aprilaireco 2 года назад
Thank you for contacting AprilAire! You do need to connect the ODT sensor to the ODT terminals in order for the unit to run in Automatic Mode. If you were to switch it to the Automatic Mode without the ODT, you would receive an E3 error code, which means no ODT. The humidifier control does not function while in an error. For clarification, Automatic Mode does not affect anything in the humidifier's operation. It just adjusts the set point we are trying to reach based on outdoor temperature, hopefully to prevent condensation from occurring on your windows. If you have any further questions on how the humidifier control functions, please don’t hesitate to reach out to us at 1-800-334-6011. We would be happy to assist. Thanks again for contacting AprilAire.
@JB-hn6qw
@JB-hn6qw 3 года назад
What if I don't have a W in my furnace block?
@aprilaireco
@aprilaireco 3 года назад
Hi Jason - Thank you for contacting Aprilaire. If you could give us a call directly at 1-800-334-6011 at your earliest convenience, we'd be happy to address your questions.
@Skinnerinnovations
@Skinnerinnovations 3 года назад
Does the (summer-winter-summer) inlet side connect to the return duct?
@aprilaireco
@aprilaireco 3 года назад
Hello! Thank you for contacting Aprilaire. If you could give us a call directly at 1-800-334-6011, we'd be happy to address your questions.
@dawnchasse4598
@dawnchasse4598 8 месяцев назад
How much water does this use?
@aprilaireco
@aprilaireco 8 месяцев назад
Thank you for contacting AprilAire! The Model 600 uses 3 gallons per hour. If you have any additional questions, we would be happy to assist.
@trentlarm30
@trentlarm30 4 года назад
What if you live in a place with low humidity in the summer? Can I leave the damper open on winter all year?
@aprilaireco
@aprilaireco 4 года назад
Hi Trent - Yes, you can leave the damper on winter year round. We’d like to point out that if you run an AC unit, the evaporative humidifier will work less efficiently. Please give our Healthy Air team a call directly at 1-800-334-6011. Thank you!
@gregsnyder2704
@gregsnyder2704 3 года назад
So I’ve read some say put on supply some say put on return 🤷‍♂️also hot water or cold water 🤷‍♂️
@ptg01
@ptg01 4 года назад
I am curious why Aprilaire provides saddle valves ? My 30+ years of experience with them is they deteriorate over time and causes a mess. Isn't it better to use a ball valve ?
@aprilaireco
@aprilaireco 4 года назад
The work, time and cost associated with a ball valve can sometimes be prohibitive to some customers, so we include a cheaper option as well that in most cases works perfectly fine. If you have further questions, please give us a call at 1-800-334-6011. Thank you!
@ptg01
@ptg01 4 года назад
@@aprilaireco This makes sense.....but with saddle valves (primarily for refrigerator ice/water and humidifier) all of mine went bad on me after 10 or so years (and I have very high quality water here). The humidifier saddle valve that we shut off every season went bad sooner. It seizes up and the rubber basket also deteriorates and seal no longer works.. Professional plumbers refuse to use saddle valves. I've had mine replaced with ball valves several years ago and it's been trouble free so far. Yes, it costs more up front but the possible mess it can create down several years is significantly more than the $150 or so you pay a plumber to install saddle valves. I suppose it all depends your time horizon..
@rkaraidos
@rkaraidos 3 года назад
Saddle valves are the norm on most ice makers I've replaced a few that were over 25 years old and didn't leak I have had shut off valves leak at the packing nut
@ptg01
@ptg01 3 года назад
@@rkaraidos Thanks for your info.. I am a firm believer in ball valves though... Saddle valves are simply bad news based upon my over 20+ years of experience. It will leak or seize.
@ignacio8597
@ignacio8597 3 года назад
@@ptg01 the humidifier is only active during calls for heat, so there isn't a need to shut it off after every season. But you are right and most places around me it is code to use ball valve and some require an arrestor as well.
@ORIGINALJRL
@ORIGINALJRL 3 года назад
Do you have to use the April aire control board that gets mounted to the duct? Or can you have the humidifier wired to a wall humidistat in your home?
@aprilaireco
@aprilaireco 3 года назад
Hi Julian - Thank you for contacting Aprilaire! You do not need to use the Model 60 Automatic Digital Control. You can have it wired to the wall humidistat - just make sure you are using a transformer in that circuit to provide 24V directly to the solenoid. If you have any additional questions, we'd be happy to help. We can be reached at 1-800-334-6011.
@jodywen4932
@jodywen4932 3 года назад
Does it work on the model Max Air 100e furnace?
@aprilaireco
@aprilaireco 3 года назад
Hi Jody - Thank you for contacting Aprilaire. If the furnace has a variable speed motor in the unit then the slower fan speed would affect the amount of evaporation occurring off of the water panel. The amount of humidity being evaporated on the Model 600 is reduced with the slower fan speed. We would recommend our Model 700 or 800 humidifier as they would be better options with that furnace. If you have any additional questions, please let us know. Thank you!
@TISINLI2
@TISINLI2 Год назад
Does the product come with hole saw?
@aprilaireco
@aprilaireco Год назад
Thank you for contacting AprilAire. It does not. If you have any further questions, we would be happy to assist.
@MyEyesBled
@MyEyesBled 3 года назад
Play at 1.5x speed... thank me later...
@TheReedsofEnki
@TheReedsofEnki 3 года назад
Good thing I know how to flip the badge. That is the most important step.
@mercimerci7286
@mercimerci7286 4 года назад
How much is that
@aprilaireco
@aprilaireco 4 года назад
Go to www.aprilaire.com/find-a-pro to find an Aprilaire professional in your area.
@abudeissa7204
@abudeissa7204 3 года назад
Wiring is not clear
@aprilaireco
@aprilaireco 3 года назад
Thank you for contacting Aprilaire. We would be happy to assist with any questions you may have. Would you mind giving us a call at 1-800-334-6011?
@flashmedia8953
@flashmedia8953 3 года назад
$300 bucks for this basic product? Omg, I could easily build this
@m.p7227
@m.p7227 3 года назад
The only thing I see getting complicated for you is with the control unit and the sensor with all of the electronics within that. There is a bit of computer engineering that goes into the electronics.
@flashmedia8953
@flashmedia8953 3 года назад
@@m.p7227 of course, sensors are easy to get same with control board. I could easily program a microcontroller for input/output using C++. Humidity sensor is what I need to control the output. Solenoid valve is simple to find which will open and close water supply from main water copper line. ASCO solenoid makes ton of these. There are other brands out there as well. I could even make this so that it works through my phone app. It is the 21st century, these things are not hard to implement. Internet of things.
@WiCapitalco
@WiCapitalco 3 года назад
Yea but its more efficient to just buy this thing. The time to get all your parts and putting them all together will surpass the time to just make a few bucks lol
@yoyomurph9613
@yoyomurph9613 3 года назад
Hope that's the install price, these units are only $175.
@s2s_parrotfan236
@s2s_parrotfan236 4 года назад
We, we, we, we, we, our our our YOU are opening the box... not we, YOU are YOU are doing it. Get your pronouns right.... very annoying. n That drain "spud" needs a better seal. without a ridge, the drain hose can fall off, resulting in water flowing onto the floor... PLUS you failed to include a step to attack an overflow drain hose.
@brikkman4700
@brikkman4700 4 года назад
aw, you beat me to it.
@abcdefghijklmnop5777
@abcdefghijklmnop5777 3 года назад
@s2s_Parrot Fan, your punctuation, proofing, and capitalization needs improvement. Hope you don't live in a glass house. Your critique is unhelpful.
@rkwoodruff9
@rkwoodruff9 3 года назад
Is it necessary to connect the outside temperature sensor?
@aprilaireco
@aprilaireco 3 года назад
Hi Randy - Thank you for contacting Aprilaire! It is only necessary to install the outdoor temperature sensor if you wish to run it in automatic mode. If you have any additional questions, we'd be happy to help.
Далее
Unboxing & Install | AprilAire Model 700 Humidifier
12:19
Aprilaire 600M Humidifier Installation Walkthrough
14:46
Будзек и рецепт🐝
00:25
Просмотров 59 тыс.
Do YOU Need A Home DEHUMIDIFIER? How to know
10:00
Просмотров 30 тыс.
Humidifiers: Simpler is better?
28:34
Просмотров 2,2 млн