This week, Mike explains the basics of unloaders and how to set an unloader to optimize the performance of your gas pressure washer.
Subscribe | bit.ly/VPPSubscribe
Watch More here | bit.ly/VPPVideos
Follow Veloci Performance & MTM Hydro:
Facebook | bit.ly/poweredbyvelociFB
Instagram | bit.ly/poweredbyveloci
Shop Veloci Performance & MTM Hydro
www.mtmhydroparts.com
Become a Dealer
www.vppdealers.com/become-a-d...
At Veloci Performance™ Products, we go to work for businesses that hold themselves to a higher standard. We are the premier provider of performance equipment. Our products are more intelligently engineered, made from higher-quality components and precision tested, to ensure hard-working teams can deliver unrivaled work results that build a positive reputation and move business forward.

Авто/Мото

Опубликовано:

 

5 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 32   
@EazzyBeezie
@EazzyBeezie 2 месяца назад
Awesome video coming from a Pressure/Softwasher! Subbed
@freestonsfinest4002
@freestonsfinest4002 Год назад
Great quality video! Super informative! And exactly what I was looking for, keep it up!
@franciscoguerra8192
@franciscoguerra8192 Год назад
Great explanation! Thanks
@dlsimes
@dlsimes 5 месяцев назад
Thank you for this very informative video. We have a Simpson 4400 psi pressure washer that has a built in (part of the pump) unloader. As far as I can tell it does not have a bypass like the machine you show in your video. It only has a pressure relief valve and then a small (possibly) another relief valve on the bottom of the unloader. There does not appear to be any extra inlets of outlets to install a bypass hose to. Would we have to install a secondary unloader in order to install a bypass hose to run out on the ground or recapture in a tank?
@erhelitruck
@erhelitruck Год назад
Thanks for sharing, great information. Could you please let me know any idea how to bypass my Predrator 4400psi, 4gpm?
@Jackhole_Cat
@Jackhole_Cat Год назад
Is the ball bearing that is on the end of the unloader needle supposed to come out?
@user-gy3xi3pi4i
@user-gy3xi3pi4i 11 месяцев назад
Very nice tut, How to choose the right unloader and where i can buy ?
@Z-Ack
@Z-Ack 9 месяцев назад
What does it mean when it suddenly kicks into bypass while pulling the trigger.. it will be fine than randomly just stop the pressure.. just cleaned the valves so dont think it then, changed the bearings botg roller and ball..and changed oil..
@handymangamer238
@handymangamer238 Год назад
I can't seem to find this unloader on your website to buy, is this discontinued?
@philliphall5198
@philliphall5198 Год назад
I have my handle zipped tie open and i tie it down when i start it at low speed It’s 12/13 years old and no problem at all
@marknye51.thefixitguy
@marknye51.thefixitguy Год назад
Good Explanation but what about these Ryobi pressure washer 3000s with Honda GCV160 engines and runs great with trigger on wand fully depressed but surges when idle. How do I set my unloader valve on it
@PoweredbyVeloci
@PoweredbyVeloci Год назад
That surging sound is the unloader operating and pushing water into bypass. You will need to refer to the Ryobi manual to properly adjust.
@erhelitruck
@erhelitruck Год назад
Thanks for sharing, great information. Could you please let me know how can I bypass my Predator 4400 psi 4gpm?
@PoweredbyVeloci
@PoweredbyVeloci Год назад
All complete pressure washers will come with an unloader installed.
@erhelitruck
@erhelitruck Год назад
​@@PoweredbyVelocimine has it's unloader, but it doesn't have that black hose
@herbertstephenson3923
@herbertstephenson3923 Год назад
Why is my pressure washer building pressure while I’m trying to crank it. I have to hold the trigger for it to come on
@PoweredbyVeloci
@PoweredbyVeloci Год назад
Prior to starting, always run water through the pressure washer to release any built up pressure. This is especially important after a failed start as the actuated pump will have built up pressure in the system making it difficult to crank.
@philliphall5198
@philliphall5198 Год назад
I just zipped tie my handle open with zip ties and tie it down while starting at ideal
@joaquinsuarez6090
@joaquinsuarez6090 Год назад
I have the same problem. If I don't open trigger to release pressure first, the machine won't start. You can put anything in trigger as well while starting it, like a small ball, soda can, folded towel, etc.
@TruthOverLies
@TruthOverLies Год назад
Your unloader valve may be dirty/clogged. Take it off and thoroughly clean it.
@fushion999
@fushion999 2 года назад
Could anyone tell me how to spot the difference between a trap pressure unloader and flow? I've looked at mine and cannot tell.
@PoweredbyVeloci
@PoweredbyVeloci 2 года назад
A trapped pressure unloader is the full formal name for an unloader.
@Jennifer-007
@Jennifer-007 Год назад
This video should be titled "How an unloader works" not "How to set one"
@Brad.W
@Brad.W Год назад
Now see this is confusing to me pretty sure my machine needs a new unloader valve and whats bad it's a brand new machine. I've already contacted the manufacturer and they're sending me a new one. Now my confusion is somebody clarify this for me my machine is rated for 3600 PSI with a 0° red nozzle or a turbo nozzle on my wand when I pull the trigger on the gun im barely getting 2200 psi but when I let go thr head pressure jumps all the way to 4200 psi and then settles at around 4000. Funny thing is adjusting the unloader does nothing for the pressure but when I tighten it down the head pressure increases instead of the outbound pressure including where it settles for example tightening it almost all the way down at the manufacturer's full stop idle head pressure jumps all the way to 5000 psi and then settles at around 4800 psi and the engine definitely does not like it because it's strains like crazy to get it there but what's weird is when I pull the trigger no matter where the unloaders is set on the gun pressure drops all the way to 2200psi or lower depending on what nozzle im using like the 40° nozzle when it's installed pressure barely goes to 1200 psi and then skyrockets to 4000 psi as soon as i let go of the trigger. Surely that is a sign of a failed or malfunctioning unloader valve?
@PoweredbyVeloci
@PoweredbyVeloci Год назад
Where are you measuring the pressure from? Also, keep in mind that the operating pressure will not change between a 0º and 40º nozzle. The spray pattern only changes the fan, not the orifice of the nozzle. And if your nozzle size is too big you would experience a pressure drop. Use this calculator to double check your orifice size requirement based on your pressure washer PSI and GPM: www.mtmhydroparts.com/pages/nozzle-size-calculator
@Brad.W
@Brad.W Год назад
@@PoweredbyVeloci that could very well be my issue because all the nozzles that came with the machine for example the 0° tip says 00027, 15027, 25027 and so on. each tip starts with its pattern size and then ends in 027 so I'm going to assume that all the tips that came withe the machine are 2.7. but what's confusing to me is I have tested in a 5 gallon bucket it takes nearly four full minutes to fill it so I'm definitely getting half the GPM as well as only 3/4 of the rated pressure My pump has a pressure gauge right at the outlet set up is like so it goes pump outlet, female to male threaded pressure adapter with 1/4-inch inlet threads that the pressure gauge is in then to a threaded female quick connect so I'm getting head pressure readings I don't have a pressure gauge for the end of the hose yet so no idea exactly what the pressure is at the end of the hose. All I know is I'm getting a massive swing when pulling the goes from 4,000 PSI all the way down to 2200psi when spraying when I let off it rockets up to 4200psi and then settles at around 4000 adjusting the unloader down does nothing but lower the idling psi does nothing for the operating psi which stays at 2200 no matter where the unloader gets set.
@PoweredbyVeloci
@PoweredbyVeloci Год назад
It's very possible that the pump is not operating correctly. Could be debris in the system or bad valve. If you're still experiencing issues once the unloader is replaced, the next step would be servicing the pump.
@Brad.W
@Brad.W Год назад
@@PoweredbyVeloci it's a brand new machine had it less than a week if there's a problem such as that going on it's going back to Simpson or at the very least I'm sure they will just warranty the pump.
@JackWorkz
@JackWorkz 9 месяцев назад
Check valves not closing, probably has some debris in it, or it's failed completely
@1stFlyingeagle
@1stFlyingeagle Год назад
I have a Dewalt direct drive I believe 4000 psi 3.5 or 4 gph. Can I make it discharge to the ground or a tank?
@PoweredbyVeloci
@PoweredbyVeloci Год назад
Yes, you would simply plumb it to dump to a tank instead of back into the water supply inlet. We recommend capturing the water wherever possible.
Далее
Unloaders Part 2: How to Install an Unloader
4:42
Просмотров 19 тыс.
Unloaders Part 3: Diagnosing and Repairing Your Pump
17:02
Мой инстаграм: v1.ann
00:13
Просмотров 51 тыс.
ELA NÃO ESPERAVA POR ISSO 🥶 ATTITUDE #shorts
00:20
How to Set an Unloader Valve (Pressure Regulator)
5:12
How to Adjust a Pilot Valve
5:24
Просмотров 297 тыс.
ВЫХЛОП КАК У АХМЕДА WENGALLBI
0:59
Котенок застрял в дне машины
0:29