Hi How you can use special characters as a variable for engraving cycle for ex i want to use 160(0%) as a variable and i want to use that variable in engraving program
hello, do you now, how to change a level to parameter MD13200 $MN_MEAS_PROBE_LOW_ACTIVE[0] by command REDEF in mode 4(between servise level)? in manual do not write in whitch file do this and how its activated... so we need that this parameter will changed in level mode 4 (red key to 3 position), because $MN_MEAS_PROBE_LOW_ACTIVE=1 use for touch probe and $MN_MEAS_PROBE_LOW_ACTIVE=0 - to laser blum... so how to change APW 4 only for this parameter?
are you able to manufacture password in? I would be surprised if the issues has anything to do with the access level. It may have more to do with the activation mode (e.g. CF , NC reset , PO reset, etc.)
refer to this application guide. www.industry.siemens.com/topics/global/en/cnc4you/tips_and_tricks/Pages/vibration-control-turning-workpieces-with-sinumerik.aspx
If you want to call up a sub-program in the Sinumerik it is as simple as entering the name of the file. for example if you wanted to call up a program called cube.mpf it would look like this. When the system sees the name in will automatically look for a file with that same name. N1 G54N2 CUBEN3 G55N4 CUBE