Vertical Screw Chiller Commissioning Issues 

HVACTIME
Подписаться 45 тыс.
Просмотров 2,5 тыс.
50% 1

I take you through a commissioning follow-up of a vertical screw chiller. Quality commissioning is a major part of being a chiller technician. It requires a proper understanding of equipment and operating principles.
Don't want to be a Chiller Tech and Be One at chilleracademy.com
CSG
Jake Little
jake@csgcompressors.com

Опубликовано:

 

8 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 18   
@destronger5313
@destronger5313 Месяц назад
HVAC Manufacture: “Here’s the unit you ordered.” HVAC Tech: “It’s not working correctly.” HVAC Manufacture: “Sounds right, and it’s your fault.” HVAC Tech: “…”
@ChrisHarsh-bt2rq
@ChrisHarsh-bt2rq Месяц назад
It is nice when you can run a system fully loaded long enough to tune and adjust it properly.
@angrybeavers1175
@angrybeavers1175 Месяц назад
The startup guys around here turn it on and for the hills. That's for all equipment, boilers, chillers, etc. Good times.
@Erikmiles87
@Erikmiles87 Месяц назад
Bro, we had DB come to a site of ours for startup. A property group subbed us to do the install of just the chiller. The controls in the plant were toast. DB signed off on the startup for the property management group and released it w no tower fan control, no condenser pump control, and no condenser head pressure control for low ambient. Lost that machine in tree weeks. Oil logged and locked rotor on compressor one.
@sij2218
@sij2218 Месяц назад
Have you ever experienced air cooled screw chiller got low suction pressure when it switching to next chiller. There is more than 10 chillers and got same alarm when we try to switching to next chiller. I am assuming water flow problem. Cuz i can see water differential pressure down but never goes to under limit. It’s kind of commissioning for data center chiller. They want to test chiller on as rough as possible environment
@HVACChillin
@HVACChillin Месяц назад
On-the-fly tuning doesn't give me all the warm and fuzzy feelings when I'm starting up a chiller. I
@HVACTIME
@HVACTIME Месяц назад
There's a lot to tune on these at startup
@HVACChillin
@HVACChillin Месяц назад
Shouldnt that be done at the factory?
@HVACTIME
@HVACTIME Месяц назад
They teach doing it in the field at startup
@zekenzy6486
@zekenzy6486 Месяц назад
Great video. Thank you for sharing
@albertmontilla7954
@albertmontilla7954 Месяц назад
Good stuff !!
@jeanbaptisteacsystem3092
@jeanbaptisteacsystem3092 Месяц назад
Good
@TrueMetalJake
@TrueMetalJake Месяц назад
Why would you risk voiiding the warranty by messing with the settings? You could have just called back the factory rep to do it for free.
@HVACTIME
@HVACTIME Месяц назад
We are the factory rep. Part of commissioning.
@TrueMetalJake
@TrueMetalJake Месяц назад
Oh ok. You said the factory guy lowered the liquid level to 25%​@@HVACTIME
@HVACTIME
@HVACTIME Месяц назад
Sorry they recommended setting it to 25% as a default in training. But also state it needs to be calibrated.
@technomakealam
@technomakealam Месяц назад
Hello sir my Trane compressor Overlord error coming why I m technician what to do
@kevinmithnick9993
@kevinmithnick9993 Месяц назад
Pray Trane gp2 gods for help
Далее
First 5 Steps to Troubleshoot Chillers
12:57
Просмотров 4,7 тыс.
YK Surge Troubleshooting: Chiller Training
13:56
Просмотров 1,6 тыс.
Я ЖЕ БЕРЕМЕННА#cat
00:13
Просмотров 543 тыс.
YK Overview Centrifugal Chiller York HVAC Training
27:47
Daikin / McQuay Chiller Surging After Rebuild
10:18
Просмотров 2,7 тыс.
TRANE RTAC Chiller compressor oil filter replacement
3:02
Tripping Low Pressure York Air Cooled Chiller Down
26:01
York Chiller Refrigeration Cycle - YCIV & YVAA AC
30:38
How IGBT in Chillers Work
4:34
Просмотров 2,9 тыс.
How Trane Screw Chillers Loaders Work
6:04
Просмотров 15 тыс.
YK IGBT Test Procedure: Chiller Training
11:46
Просмотров 2,2 тыс.