Sir, is it possible you make a chart for all the requirements for beams and columns, their size, spacing, steel dia, number of steel bars, size of footing etc.. for domestic and commercial buildings from G+1 up to G+10? It will be very helpful and we will appreciate.
salam im planing to build my house and it has ground flr 1st flr 2nd flr then roofdeck and im planing to use in my footing size 1.30x0.40hight and then the column is 4 16mm and 4 12mm rods vertical rebars with 2double ring or diamond lateral ties size 0.30 ty i just want to to know if it can hold the weigth of the roofdeck size house plan is 118sqm and all foundation is 12 pcs
Sir 1200 sq ft m ghar bnana h mujhe..3 manjil building bnane k liye pillar ka size 10"x10" de skte h with 6 rods of 12 mm. Distance between two pillars is 10 feet.. Please mera reply kre ❤💯🙏🏼🙏🏼🙏🏼🙏🏼
Im Emgineer but not CIvil Engineer Hi Sir just want to ask ,regarding foundation of bungalow house with 100 sq.meter. we want to renovate with mezzanine design or second floor...whatbis the size of footing and column...and can we still use the existing column.
The ground condition differs from location to location. Therefore, it is too risky to say three-storey house can have 2x2 m pad foundation. Please advise anyone constructing a house to get a structural engineer instead of guessing foundation needed for their house.
Hello sir. What if the distance of the column is 2.5 meters and we used 8 pcs 16mm but the footing is only 1 meter. The 2 center combine footing is 1.5x3.5 and we used 8 pcs 20mm for each center column. Is it ok for 3 storey?
Khan g mara house load bearing h os m koye column beam nhe h or ha b single story to m os m cloumn nd beam dna chata ho os k koye tarika btay existing building m
Dear Civil Engineer, Please can you explain what will be Length, Width and also the Depth of Footing because for footing Calculation this is very important for 3 Story Building and also you explain Volume of Concrete, Shuttering Area
Sir, please make video or explain , the footing and size colum , reenforcement steel size for G+ 4 story building. Of 1000 sq ft corner House. Please reply and make a video please 🙏🙏 🙏
For that, you should contact with structure engineer. It comes in highrise buildings so that's , why you have contact with structural engineer instead of this.40/50 story building, is very hard to design because it will include the seismic loads, wind loads etc.you can't decide by self or by experience. That need a specific design of each member.
@@saeednegar709 Sir, matlab pehle aisi Building ke liye Column, Beam, Brick work and Slab ka Self weight and Dead load, Live load, Floor load, wind load calculate hoga, Phir load bearing capacity ke check ki jayegi Pu= 0.4 fck Asc + 0.67 fy Asc iss formule se. Thik hena Sir?
@@shamsheralirana3127 yes but you have to follow the code formulas like IS code,ACI ETC..for all those things you just need to design that in a software.software will follow the code then will calculate all the things.so you need to put loads from codes in software.after running analysis and design you have to calculate the total weight and load of a building in a softwares..then you have to use CSI safe software for footing design.
How about the Live Load, this must be included also. You just stated the load but not explaining if the load includes Live Load. Because in a design, Dead Load and Live Load are specified.
Sir I request you to make next video for ""How todesign the complete building"" .or upload pdf file design and analysis of building at least 2 storey building sir. Plz do sir