Where we Can Provide Lapping in Beam and Slab ? Best Zone for Lapping in Beam 

Civil Engineers
Подписаться 900 тыс.
Просмотров 38 тыс.
50% 1

1) Construction cost of 1000 square feet House 2019? Cost of House Construction per square foot 2019
• Construction cost of 1...
2) Grade Of Concrete and water Cement Ratio
• Grade Of Concrete and ...
3) How to calculate Cement, Sand, and Aggregate for M20 concrete
• How to calculate Cemen...
4) Depth of Footing/Foundation and Reinforcement details in Foundation
• Depth of Footing/Found...
5) Maximum distance between two RCC columns?
• Maximum distance betwe...
6) Big Mistakes in RCC Slab - Lapping Mistakes
• Big Mistakes in RCC Sl...
play Lists :
Construction Videos :
• How to Chose Good Qual...
Construction Site Visit :
• New Exterior Design fo...
House Planning Play List :
• How to Study Column wi...
#CivilEngineers #CivilEngineering

Опубликовано:

 

1 янв 2021

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 34   
@PatrickInCayman
@PatrickInCayman 3 года назад
Excellent, thank you!
@burtreynolds4917
@burtreynolds4917 2 года назад
Thank u sir for this video continue your work... god bless u
@phyohtetkoko929
@phyohtetkoko929 2 года назад
Thanks For Teaching Sir
@keshavamurthymn2939
@keshavamurthymn2939 3 года назад
Excellent explain sir
@md.mizanurrahmanaru3128
@md.mizanurrahmanaru3128 3 года назад
Sir love u,,,,,,,From Bangladesh,,,,,,,
@abdurrahim3605
@abdurrahim3605 2 года назад
Thanks
@MasterCivilEngineering
@MasterCivilEngineering 3 года назад
Master your civil engineering knowledge here📖📖📖
@maberikinstink9407
@maberikinstink9407 2 года назад
You are contardicting yourself Mr. Engineer because in your video titled LAPPING FORMULA FOR BEAM COLUMN AND SLAB uploaded on 2-15-21 you said that lapping in a continuous beam should be done at the support but in this video you are saying you cannot do lapping at the support. What is true? Will wait for your reply on this because i am confused. Been an avid follower of your videos. Thank you.
@devsouting5695
@devsouting5695 2 года назад
I also have the same question
@agiti
@agiti Год назад
good for students & some pro
@jeyakumar9194
@jeyakumar9194 3 года назад
Thanks sir pls explain the best laping for colum Jone
@h.alhaidre9020
@h.alhaidre9020 3 года назад
Excellent from iraq
@shashangkipgen6065
@shashangkipgen6065 3 года назад
professionalism is 1000
@handsam5
@handsam5 2 года назад
Compression zone is the best place for lapping length.
@BA-kl6bv
@BA-kl6bv 2 года назад
Pls. lap location for raft and swimming pool and grade slab connect with tie beam / with out connect with beam
@paklahisap2646
@paklahisap2646 3 года назад
In the other Video you said for Compression Zone lapping length 24D.
@mjk568
@mjk568 2 года назад
It is minimum
@mohammedafsal5876
@mohammedafsal5876 11 месяцев назад
What about plinth beam. Is there is any change in compression and tension zones
@armyofficermanishsharma5039
@armyofficermanishsharma5039 3 года назад
From india
@armyofficermanishsharma5039
@armyofficermanishsharma5039 3 года назад
Good morning sir
@lismanpermana8218
@lismanpermana8218 2 года назад
sir.. where is lapping zone for distribution bar/side face bar.. ?
@nikkofebryanto1486
@nikkofebryanto1486 2 года назад
What happen when you didn't put leaping on top sir?
@petermapp5988
@petermapp5988 2 года назад
Born to teach
@sgpfamilysgpfamily844
@sgpfamilysgpfamily844 Год назад
Sir people are telling the beam lapping should given in column middle . Which is correct
@anishanishkt5284
@anishanishkt5284 3 года назад
Your previous video the lapping zone given at support why
@orangkota4010
@orangkota4010 3 года назад
Yea thats what i want to know too
@shivamurthykattennavar8233
@shivamurthykattennavar8233 3 года назад
which one is correct sir this or either previous video?
@gsaulakh9893
@gsaulakh9893 3 года назад
Sound or video alg alg chl rhe h
@shivamurthykattennavar8233
@shivamurthykattennavar8233 3 года назад
What happened sir ur left hand..
@irfanullah6540
@irfanullah6540 3 года назад
Sir tabyat mo snga dy
@xaviahmad6368
@xaviahmad6368 3 года назад
What is 2d mean?
@EngNoora-tc2rb
@EngNoora-tc2rb 2 года назад
It's mean 2 times the effective depth of beam . In another way = 2 × effective depth for beam (d). .Noora from Iraq 🇮🇶
@najibaibrahim3097
@najibaibrahim3097 3 года назад
That means l/4 not true???? That is just for stirupp ….After l/3 is suitable for lapping the top
@engrasgharbadshah9247
@engrasgharbadshah9247 Год назад
You living in Pakistan and using or referring IS code strange, you should be referring ACI rather than IS.
Далее
МЕГА ФОКУС С КАЛЬКУЛЯТОРОМ
00:33
The actual reason for using stirrups explained
9:01
Просмотров 772 тыс.
Lapping zone in Beam
11:32
Просмотров 46 тыс.