Aap ek banaye jisme pure plant ka information ho jaise kitne tr ka water chillar hai cooling tower kis capacity ka hai kitne hp ki motor Lage hai kittne pump hai matlab ek plant room ka full informatic video banaye. Sukriya....
dost hamne aor bhi vidio upload kiya hua hai jisme plant details hai .. description me link hai aap dekh sakte hai...baaki kuch doubt ho to aap pooch sakte hai Sukriya 👍
Ji agar apke cooling towers ka COC 3.5 to 5 ke beech me hai to apko 200 ml ya 300 ml tak chemical add karna rahta hai .. around 40000 liter se 80000 liter water me .... Aor agar apke cooling tower ka COC 5 se ooper ja raha hai to apko chemcal ki capecity badhani hogi ... Aor uske sath sath apko 👉cooling tower ka water bhi kuch drain karna padega ....
Ji agar apke cooling tower ka COC level 5 ke andur hai... to apko chcemical 200 ml add hoga ... Aor agar 5 ke ooper coc hai to chcemical ki dosing jyada hogi
Agar apka tds ppm aor ph level under coc rahega yani ki sab kuch theek rahega to weekly ya phir har teesre din ..aor agar tds,ppm,ph jyada rahega to daily padega ...sukriya ji apka 💐
dost ...ye condenser ki capecity pe depend karta hai ....uske GPM ko nikalalne ke baad ....aor phir hight pipe length.....👉 aor agar only apko .. cooling tower ke tank ka water capecity nikalna hai ..to pahle us cooling tower ke tank ki depth and width nikalo phir aap direct liter nikal sakte hai aap .......👍
Ji hamne already ph,ppm,tds,tools par vidio upload kiya hua hai ..aap channel pe jaake dekh sakte hai .. aor bhi agar kisi cheej ki jaankri chahiye to ham jarur apke liye vidio upload kar denge ...💐💐🙏🙏
Depend on water parameters..if parameters high mean PH and hardness and TDS so chemical amount will be increase and if parameters in average so .. 200 ML chemical dosing in cooling towers
Sir, let's say l have checked ph, ppm and tds, found these are not as per standard requirements. Please make a video on dosage calculation with examples for a better understanding.
केमिकल कितनी कितनी मात्रा में डालना है कूलिंग टावर में वह अपने बताया नहीं वह आप बताओगे तो काम थोड़ा आसान हो जाएगा इस पर आपने वीडियो डाली है नहीं डाली है तो डाल दो तो बड़ी मेहरबानी हागी सर
Ji iska bhi ...PH TDS PPM ( haardness) hota hai ..but ye parameter hamesha under maintain rahta hai qki ye chilled line ka watar poori tarh se pack rahta hai ...kahi se bhi dhool mitti jaane ka chance nahi rahta hai.......isme bus 2 cheej badhti hai wo bhi 1 ya 2 saal me ..chloride and nitryt ..ye parameter valve ke jung ke lagne ki vajah se badhte hai ..jo jung lagta hai wo paani me mil jaata hai ...iske liye ham 1 saal me 25 ltr corrosion inhibitor chemical daal dete hai chilled line me ....sukriya
Only drain water .. Tds agar badh raha hai to apko 👉condenser line se water drain karna padega ... Uske liye koi chemical nahi hai ... .👉. COC ke hisab se apko water parameters maintain karke rakhna padta hai ।।। COC Ki vidio main upload ki hui hai aap link pe dekh sakte hai apko aor achee se samjh aa jayega ...👍 Sukriya
depend on your coc level ...mean agar apke cooling tower ka parameter yaani ph .tds .and hardness sahi level pe hai to 300 ml 300 ml add hota hai .aor agar water parameter high ja raha hai to quantity badha di jaati hai .. chemical name👉 ..anti scaler , corrosion inhibitor,and alkaline reducer
aor kahi kahi par dosing pump lage hote hai wo auto pe work karte hai ..jitne chemical ki required hoti pump usi ke according dosing karta rahta hai ..