नमस्कार सर, हमारा घर 4 मंजिला का है, घर के बेसमेंट की उंचाई 4ft है, जमीन से 4ft के उपर हमने plinth beam दिया है ground beam दिया ही नहीं, और column के लिये जमीन में 5ft गड्डा लिया है, 4 मंजिला घर के लिये ये सब बराबर है की नही ?
Next question related to plinth. What is plinth protection? How can we take precautions so that water doesn't "touch" the periphery of the building, and it just flows off, thus there is no water seepage. If we have a plinth beam, is there a need for DPC ? Will the plinth beam act as a DPC ? IF the plinth is a bit lower - say just about 1 ft from internal road level, then is there a need for additional DPC ?
Placing empty bags of cement between the soil and the plinth beam can cause any damage ? the plinth top level is about 1 feet down from the road level and contractor doing this...plz suggest
Sir plinth beam v dala hai, door level par v two sariya daal ke concrete ki hai,plinth beam ke neeche v bricks work kiya hai or devar ke dono Corner par beam lagge hai 6-(12mm)ke sariye ke daale hain par fir v devar ke crack a gya hai uska kya karan hai, kya dewar settle huyi hai,sare makan mein 15 beam Dale hai or sabko plinth beam se joda hai or door level par v joda hai, kya iske baad v settlement issue a sakte hai.
Sir mera GL ka beam existing ground level se 1 foot niche hai aur floor level existing ground level se 3 foot upar hai . Yane dono me 4 feet ka antar hai isme dono Beam GL and PL dene se achha hoga ? Please batayen
Sir mera plinth beam road se 1 feet uper he aur outer plenth beam k niche 5 feet 9 inch wall karayi h but inner plenth beam k niche 1 eit lagakar plenth beam dala h...koi problem to nahi hogi?
Sir, Can we use stones or AAC blocks in place of bricks in column based house structure and if yes, how and how much more stronger foundation it will become? And is using AAC blocks for full house in Delhi will give more strength and will our house becomes more cool in summers compared to fly ash bricks?
Brick wall below the plinth beam - on periphery? Brick wall will also merge with soile over years - due to water. Why not have SSM on periphery walls below the plinth beam?
1. What alternative can be used below Plinth beam apart from red brick ? 2. Can we use AAC blocks below plinth level ? 3. Can CLC Blocks be used below plinth level ? 4. Any other material that can be used in replacement of red brick below plinth ?
big size stone peices. in Rajasthan people use stone for underground structure. it is water resistant. bricks below soil will loose strenght as time passes due to water soil and dampness but same is not with stone.
Hi Sir, my plinth level from road is 1.5 ft. My site engineer is planning to do pcc of 6 inches and on that plinth beam. Is this the correct process and will there be any issue in future if I don't do brick work below plinth beam ? Thank you.
Sir, if road is ready and Road s plot slop me hai...aur ground level p shop hai to road s kitna upar plinth height lena hoga.... Aur me n Ground level s 4 inch below plinth beam diya hu....aur us k upar 3 feet 6 inch heights ka bricks work kiya hu...road s 18 inch level lekar.....to kya ye sahe hai...but filling coast morum ka jada jaa rha hai.... Please make 1 video on this sir