@HVACTIME 4 месяца назад
Finish your chiller course understanding chiller systems and terminology at your pace to advance your career! chilleracademy.com
@JiyavudeenAsif
@JiyavudeenAsif 4 месяца назад
More yk chiller operation coming sir video I already subscribed
@MauriceVandenberg-c8j
@MauriceVandenberg-c8j 4 месяца назад
GREAT VIDEO SIR
@garypoplin4599
@garypoplin4599 Месяц назад
5:33 - It’s ok. I knew what you meant! Some people say _eXpecially_ instead of especially and _nucUlar_ instead of nuclear at times, too. As long as the concept you want to communicate is understood, you’re good! Thanks for being willing to share your experience and knowledge with us.
@ritesaidme
@ritesaidme 4 месяца назад
Thank you for another informative vid
@reyrodriguez1005
@reyrodriguez1005 4 месяца назад
Appreciate all the content dude!
@jmoney_638
@jmoney_638 4 месяца назад
Awesome. Thank you
@jasonjohnsonHVAC
@jasonjohnsonHVAC 2 месяца назад
Good stuff my man
@symbionese2348
@symbionese2348 4 месяца назад
Superheat means to me a condition in which a fluid has been heated to such a temperature under such a pressure as to make the vaporous state and liquid state of that fluid equal in weight. Is refrigerant increased to such a density after being pushed by the compressor? If so, how is that measured? How would a system have superheat in the low pressure side when the refrigerant is being suctioned, not pressurized?
@HVACTIME
@HVACTIME 4 месяца назад
Superheat is the sensible heat gained above saturation temperature.
@rthompson968
@rthompson968 4 месяца назад
Another good one, brother
@joshuaricks7730
@joshuaricks7730 4 месяца назад
Great job brother.
@stevencossaboon3237
@stevencossaboon3237 4 месяца назад
Another great video. Thank you for the knowledge.
@zekenzy6486
@zekenzy6486 4 месяца назад
Great video. Thank you for sharing
@kenfewell4200
@kenfewell4200 2 месяца назад
COMPRESSIVE....Sparkle Word of the Day...👍
@aleonyohan6745
@aleonyohan6745 4 месяца назад
Dude you are amazing. We built a custom 15 ton air-cooled chiller to go into a salt mine in Northern Canada. Ambient temperature in the mine will be about 115F they raised the load temperature from 80F to 105F I'm running a Bitzer scroll with 407c. My discharge pressure is 440 PSI my discharge line temperature is 225F my suction superheat is about 50F. My TXV is backed all the way out. I could handle the high ambient but the increase in high load is overwhelming my brazeplate evaporator. To top it off my condenser had to be sprayed with heresite and have a nylon screen over it. The compressor is so hot you can hardly hold your hand on the bottom side of it. I feel like the TXV is too small for this increase in load. This is the first I've heard of discharge superheat. Will definitely be getting that number in the morning. I wish we could just go to standard EEV valves. We're just having a hard time incorporating our Schneider plc with the Schnieder EEV driver. I have been pushing for engineering to oversized the EEV a little bit so that I don't starve the evaporator under these high load conditions. They seem to want to size the eev for set point or a low load situation. But then I am 100% open on the EEV but still starving my evaporator at high load. I feel like this EEV stepper motor would still be accurate at low load even if the valve was only say 12% open.
@HVACTIME
@HVACTIME 4 месяца назад
You could set it up with liquid injection for cooling the compressor a bit at peak loads because at those numbers your compressor won't last. If you'd like deeper support I have a Chiller Community where i offer troubleshooting support to those enrolled in an Academy course. chilleracademy.com
@aleonyohan6745
@aleonyohan6745 4 месяца назад
@@HVACTIME yeah I'm definitely going to enroll. Yeah the customer and our engineers want it to work, but the numbers don't lie. Compressor death for sure. I hate when they ask me what I think and I have to give them the bad news. I said do you want me to be optimistic or do you want me to be honest.
Далее
Secret to Master Tech & MY GAME
13:46
Просмотров 4,8 тыс.
Compression Ratio
39:40
Просмотров 25 тыс.
Вопрос Ребром - Серго
43:16
Просмотров 1,5 млн
Why Measure Compressor Discharge Line Temperature?
15:04
Chiller Tech Pay per $$Hr
9:56
Просмотров 3,8 тыс.
SCI Discharge Superheat English
3:41
Просмотров 6 тыс.
Chiller had high SUPERHEAT cause of this
17:27
Просмотров 15 тыс.
Prepping Chiller for Startup
19:01
Просмотров 14 тыс.
HVAC 066 Superheat notes
15:51
Просмотров 11 тыс.
Plate heat exchanger -  Vaillant 64kw
17:43
Просмотров 2,1 тыс.
Finding Target Superheat
15:58
Просмотров 20 тыс.
How SCR are used in Chillers
13:33
Просмотров 2,1 тыс.