Тёмный

Why Isn't My Electric Fence Working? - Troubleshooting Tips Every Farmer Should Know 

Plane View Farm
Подписаться 3,9 тыс.
Просмотров 11 тыс.
50% 1

An electric fence that isn't working right can be frustrating. However, most problems with electric fencing are not as complicated as one might think. In this video I cover some basic troubleshooting tips that every farmer should know whether you have electric fencing on your farm, or are planning to build electric fencing.
Check out our website: planeview.farm
• Electric Fencing/Fence...

Опубликовано:

 

28 июл 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 17   
@johnleden1909
@johnleden1909 10 месяцев назад
Very good information - thanks for posting. Love the t-shirt!
@maoqu3238
@maoqu3238 Месяц назад
Best video ever!!!!❤❤❤
@myragrapa6973
@myragrapa6973 23 дня назад
Nice video
@lustysteve1420
@lustysteve1420 4 месяца назад
Can I wrap the electric wire around a wood post or do I have to buy a insulator
@PlaneViewFarm
@PlaneViewFarm 4 месяца назад
A bare wire will ground out on the wood post, especially when it gets wet. You can use wrap around insulator tubing instead. It's a little bit cheaper than individual termination insulators. kencove.com/fence/detail.php?code=I40-100
@leroygooding6954
@leroygooding6954 4 месяца назад
can you touch tester to electric wire and steel post to test the fence
@PlaneViewFarm
@PlaneViewFarm 4 месяца назад
Yes
@theBakersonafewacres
@theBakersonafewacres 10 месяцев назад
9:10 can you elaborate more on that? I've never heard or thought of that. I'm planning on getting a much larger than currently needed charger, but I'm also adding on a lot of fencing, but in stages. I don't want to damage an expensive unit.
@PlaneViewFarm
@PlaneViewFarm 10 месяцев назад
I probably should have done that in the video. 🤦‍♂️ Being oversized for the fence system can be hard on the internals of some of the cheaper equipment. If you buy a high quality charger, you'll likely be ok.
@mjohnson4185
@mjohnson4185 10 месяцев назад
I bought a really powerful energizer and it has worked out pretty good. I do think that being oversized causes it to "find" weaknesses in your system. For example, I've had it burn through some of my cheap tubing insulators. But the advantage of the powerful system is that it burns the weeds / kills the grass and weeds so that you don't have to trim as much. For me, it's worth it to have the big joules.
@solschwartz7119
@solschwartz7119 8 месяцев назад
​@@PlaneViewFarmcan a cracked insulated cause it to ground out. Even if the wire is not completely against the post
@PlaneViewFarm
@PlaneViewFarm 8 месяцев назад
@@solschwartz7119 Yes it can! It can arc across and ground out. That's a really good question. I wish I had included that in the video.
@solschwartz7119
@solschwartz7119 8 месяцев назад
@@PlaneViewFarm thank you
@tomcopeland6424
@tomcopeland6424 2 месяца назад
I bought a 26 Joule energize and currently have it hooked up to 830 ft of poultry netting. I know that is more joules than needed but I’m planning on fencing off about 30 acres with additional cross fencing. Right now, the netting is touching grass in several area and I hear a lot of clicking. I’m concerned it might catch the grass on fire. Is that something I need to be concerned about? Will adding more ground rods reduce the risk?
@PlaneViewFarm
@PlaneViewFarm 2 месяца назад
Fire really isn't an issue with modern energizers because the current is pulsing. Older energizers had an issue with fire because the current was continuously flowing. The only real risk might be if the grass is extremely dry and the wire contacts something that might cause it to throw a spark. Even then, the risk is low because that spark isn't likely to be hot enough to start a fire. I hope this helps.
@CEGEN2P
@CEGEN2P Месяц назад
I noticed your ground wire was attached straight to tpost with clip does this help ground
@PlaneViewFarm
@PlaneViewFarm Месяц назад
Good question! It does provide some grounding for the system, but not much for a couple of reasons. The posts don't get deep enough to provide much ground contact, while a grounding rod will be at least 6 feet deep, if not more. Also, the wires are not fixed tight to the posts with the clips. They are just loose enough to expand and contract. That allows for breaks in the flow of current back to the energizer through the ground. I hope that helps.
Далее
Electric Fencing Ep. 3: Ground Systems
6:56
Просмотров 28 тыс.
Why I'll NEVER Build Another Barbed Wire Fence - Still
24:37
Наше обычное утро 💕
00:42
Просмотров 1,4 млн
Воскресный утренний стрим!
1:00:16
How does an Electric Fence system work?
2:44
Просмотров 43 тыс.
Electric Fence Problems Solved!
5:50
Просмотров 177 тыс.
Avoid These Common Small Farm Mistakes
13:34
Просмотров 8 тыс.
Finding faults in your electric fence system
5:47
Просмотров 92 тыс.
Say Goodbye to Hassle; Electric Farm Fencing Tips
5:31
We just fixed the biggest problem with our fence!
8:49
WHY I REMOVE SOLAR
14:10
Просмотров 28 тыс.
Наше обычное утро 💕
00:42
Просмотров 1,4 млн