I created this video for my Motors and Drives class at CPTC.
Sorry that the explanation isn't clear in some places, I was trying to get through it in one take without a script. Here are some points I could have explained better:
Motor Function:
Coil (A) wraps down to the bottom of the rotor and backs up. The eddy currents going down the stator spin in the opposite direction of the wire returning relative to the rotor. This is what creates (A) and (!A), which is why they're always opposite.
Feel free to post questions in the comments!

Опубликовано:

 

6 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 6   
@user-mr8my2vs9f
@user-mr8my2vs9f Год назад
Is there any way to identify the leads in a 12 lead motor? How do you figure out which are 10, 11, 12 without markings? I can't find any videos showing how to identify 12 lead motors. There are several showing 9 lead motors. Thanks
@ajlajl2992
@ajlajl2992 9 месяцев назад
U made tgis so complicated 🤯
@gritpump
@gritpump Год назад
What would happen if you connect 7 to 5 and 8 to 4?
@davidcolson1900
@davidcolson1900 Год назад
This would create an invalid sequence. Since the second set of coils connected to 7 and 8 run directly next to to the first set connected to 4 and 5, they would create contradicting eddy currents. The stator is supposed to alternate between positive and negative moving in a circular pattern in order to move the rotor. With that configuration, the stator wouldn't create the pattern the motor needs intorder to move in a circle. When you throw the power switch, the rotor would either vibrate back and forth or lock in one position. In that state, the motor is fighting it's self, so it would draw a high amperage> which means heat> which means eventual burnout.
@snakeplissken8620
@snakeplissken8620 3 месяца назад
Yeah, like everyone has an oscilloscope in their hip pocket.
@JamesJoseph-te3jm
@JamesJoseph-te3jm 5 месяцев назад
im lost after 20 seconds it dont make sense
Далее
Wye Motor Lead ID - 9 Lead Dual Voltage
20:14
Просмотров 10 тыс.
Motor Connection Diagrams (Full Lecture)
29:50
Просмотров 15 тыс.
Friends
00:32
Просмотров 824 тыс.
Identifying Untagged Wires of 9 Lead Motor
41:35
Просмотров 3,9 тыс.
3 phase motor test
10:58
Просмотров 1,6 млн
Delta Motor Lead ID - 9 Lead Dual Voltage
13:59
Просмотров 10 тыс.
HVAC 3-Phase Motors / 9 and 12 Lead Motors
9:14
Просмотров 16 тыс.
Dual Voltage, 3 Phase, 9 Lead Wye Motor Connections #1
24:15
Checking Windings in a 9 Lead 3 Phase Motor
7:55
Просмотров 293 тыс.