WVC1200 Solar Micro Grid Tie Power Inverter Teardown & Repair 

How To Guys
Подписаться 127 тыс.
Просмотров 68 тыс.
50% 1

Опубликовано:

 

21 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 139   
@allinthefamiliy3122
@allinthefamiliy3122 3 года назад
I did repair mine I had a similar problem as you describe and discovered that all panels are in parallel including the MOSFET controls. If one MOSFET fails on the panel input side you measure that failure on four of the eight input MOSFET's. I removed two of them and found the faulty one. The HF SPWM mosfets at the bottom side of the inverter are also grouped I believe it is grouped in two H-briges each bridge having 8 Mosfet's. So every H-bridge switch is 2 parallel MOSFET's . One showed a failure and i removed that one to and again one MOSFET failed. At full power I don't feel any head from the H brige. The transformers however do get hot, I changed the four aluminum heat blocks on the frond plate inside of the inverter for a litle bit thicker aluminum strip for better contact between case and transformers. I'm planning to add extra external aluminum fins. it would be nice if WVC DK would change the input MOSFET's for better ones like the IRFB4110 that has only 3.7 mOhm@25°C and cost around 0.4USD instead of the IRF3710 23mOhm@25°C That would save around 30Watt of loss at full power and a lower operational temperature. What I dont know is if the gate drivers can handle the IRFB4110 double gate charge 160nC instead of the 80nC gate charge of the IRF3710. Overall with three panels each 300Watt the temperature of the case is hand warm at around 550Watt of power like a cup of tea and a quite low wind condition, at 4x300Watt with low wind the temperature at 800Watt power is too high in my opinion, you can touch it, but it will feel hot. I estimate the case is around 60°C, to hot in my opinion. I did measurements with NTC thermistors inside on the Transformers with a closed casing. With no airflow I measured 62°C between the transformers on two panels with around 400Watt of power. As soon as I added a mild airflow from a small fan the transformer temperature dropped to 52°C. I estimate for each panel connected makes the temperature inside the casing increasing with 8..10°C starting from 40°C with zero power. What I find strange is the way the STD13NM60ND are mounted on the PCB. This is a D2PAK and the cooling of the aluminum case connect on the topside of these MOSFETS. The Typical RDSon@25C is 110mOhm. So at 900Watts@125AC with a Junction of 120°C the RMS current is 7.2 going through 2 Mosfets 3.6A each. The power dispassion in each MOSFET is 3.6*3.6*110 *2/1000=2.8Watt Part of that heat goes away through the PCB but a large part needs to go through the topside of the package to the aluminum casing? I wonder if that is a problem. Fact is that the Hbrige of 16 MOSFET's lose 16x2.8=44 Watts of power. A better MOSFET with a lower RDSon would reduce that loss. The Quality in the inside looks quite good to me, I do believe that the transformers are to small for what they need to deliver and are not well-connected to the case to lose their heat. It does work however. I will add the layout of the inverter on the internet using this link www.holamex.nl/files/img/WVC1200_layout.jpg An other WVC link ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-AJE49QckhHA.html An other WVC link ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-KF0_ZFNhLIs.html An other WVC link ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-y5d93bAAD7Y.html Message to the manufacturer, change the input MOSFET's for better ones for example like the IRFB3077, show us some more detailed information about this inverter and improve your Quality processes because quite some people complain about DOA's when received
@FunnyFantasticFail
@FunnyFantasticFail 3 года назад
So did you change the shorted mosfet to another one? I found another alternative mosfet in the internet. But at this moment I am happy with a working wvc. Let's wait for the summer.
@allinthefamiliy3122
@allinthefamiliy3122 3 года назад
@@FunnyFantasticFail yes I did change it one in the 4x DC stepup brigde and on the SPWM high voltage side and its working now. There were no diodes damaged.
@laurvonavi
@laurvonavi 10 месяцев назад
I can connect a single panel to an inverter with 2 inputs or 4 inputs, for example if it has two inputs and is 600w, I can put a single 500w panel connected with a y connector to pull the inverter on both inputs from the same panel but without exceeding the total power?
@wilhelm8347
@wilhelm8347 4 года назад
I have had the same issue (all 4 DC input shortcut) with the inverter and fixed it by replacing one of the 8 IRF3710 MOSFET, now the inverter is working again. Just measure with a multimeter the passthrough and you will find it.
@fengwei04
@fengwei04 7 лет назад
The mosfet pins you measured are not drain and source. They are gate and drain.
@MastercraftKARIGAR
@MastercraftKARIGAR 5 лет назад
Video quality is excellent.
@user-hx2hd1cu4q
@user-hx2hd1cu4q 4 месяца назад
Wow, great explanation!
@opera5714
@opera5714 6 лет назад
Thanks for the look inside. Always looking for another GTI which I can buy broken and fix. At least it doesn't have nasty potting like enphase. When you have multiple FET on the same DC buss which is shorted, I just connect to nice constant current power supply set to about 4A. Measuring voltage drop on each transformer winding, even though it is just a few mv, points me to the right FET. Very useful when it is not a bad FET but an over voltage protection diode which is shorted.
@williamvaughan1218
@williamvaughan1218 3 года назад
I would imagine you could just do temperature measurements to find the faulty components also.
@adilsonfernandesdias629
@adilsonfernandesdias629 4 года назад
To change the output from 230Vac to 120Vac, only PCB jumper modification is sufficient or other modifications are required?
@pero93ab83
@pero93ab83 3 года назад
I have a WVC1400. The input circuit is almost the same as the 1200. The difference is in the Mosfet. I replace the RF25 & RF26 and they break through. These are the KIA3510A. Something else is wrong. He could establish that with the scheme of the entrance part .
@johmemo
@johmemo 5 лет назад
Dear Kedar, thank you for posting the video. I bought this same inverter that did not work one day. The red LED is lit steadily. When it was replaced the new one worked perfectly which eliminates all doubts about the solar modules and the installation. What was the solution you adopted to repair your micro inverter? Do you have the electrical diagram. Thank you!
@BaconCola
@BaconCola 2 года назад
Mosfets are 99% the Problem
@easterndigital2691
@easterndigital2691 Год назад
This 1200W inverter is a design mistake. They use IRF3710 with power dissipation around 200W this means this inverter is for maximal 800W. The internal resistance of this IRF is 23mOhm, was better to use something like TK100E10N1 with 2.8 m (typ.)
@allinthefamiliy3122
@allinthefamiliy3122 7 лет назад
Hi Kendar, I have installed a WVC1200 and mine also died after 70KW/hr of work and a daily yield of around 5KW with 4x300Watt panels. The out side body temperature was around 45 degrees. With AC power and Panels connected the LED on the front is off. I'm planning to dissect it and do a post-mortem analysis on it.
@stephendsjones
@stephendsjones 5 лет назад
I have the same setup with 43 of the WVC-1200. 4 x 320w panels. Over half of the inverters are dead now
@BaconCola
@BaconCola 2 года назад
@@stephendsjones replace for better mosfets and modd the case add a small fan to blow the heat out
@ThiwankaWimalasuriya
@ThiwankaWimalasuriya 7 лет назад
Were you able to fix this inverter ?
@luiznicolau1857
@luiznicolau1857 4 года назад
How much maximum power one inverter like this can output from 4 330w 72 cell panels?! Thanks for video
@joseguzman-le9xw
@joseguzman-le9xw 3 года назад
1200 Watts
@jonathanvelazquez801
@jonathanvelazquez801 3 года назад
Thanks broth
@travisholmes360
@travisholmes360 7 лет назад
great VDO, I watched this VDO a few months ago and I bought the same inverter. I blew a capacitor 2 days ago, and I can not see the size of it anymore. So I was wondering if you can help me.
@laurvonavi
@laurvonavi 10 месяцев назад
I can connect a single panel to an inverter with 2 inputs or 4 inputs, for example if it has two inputs and is 600w, I can put a single 500w panel connected with a y connector to pull the inverter on both inputs from the same panel but without exceeding the total power?
@gregorybolin4672
@gregorybolin4672 6 месяцев назад
Mine had a 10k resistor near a control module labeled 110v with the jumper
@arunkrajendrapretheesh9433
@arunkrajendrapretheesh9433 5 лет назад
It's supports pmdc dynamo source without shunt resistance
@16vastraturbo
@16vastraturbo 4 года назад
I thought u was repairing this as the title suggests.
@ekiskaliburnirvana9047
@ekiskaliburnirvana9047 3 года назад
irf3710 or other 100v mosfets are not enough for this inverter. At least 150v Best is to use 200v mosfets. Mine have had 150v mosfets and still blown because of high voltage spikes. Try irfb4227
@rtos
@rtos 5 лет назад
Nice explanation
@miguelsanz2483
@miguelsanz2483 Год назад
Do you know why this??? Ac Volt 5.1v... and I have 220v. And PV actual is 0.00a Too. Where is the error?? WVC 350 Life. My inverter marks a fixed red led. The socket where it is connected and checked is 220v. But it doesn't detect. I've read somewhere it could be just one piece. The 14D471K that has been due to a power surge. what do you think?
@johnbeattie9561
@johnbeattie9561 6 лет назад
Hi Kedar, i bought one of these inverters a few week ago and tested it with 2 x 260w panels, it looked to be working fine, i decided to try each panel on their own to see how close they were so i turned off the AC power and unplugged one of the panels after turning on the AC power i noticed there was nothing on the watt meter, when i looked at the inverter there was no red/flashing green or solid green light, the whole thing is just dead, any ideas what may have gone wrong and how it may be fixed ? Take care john
@danroberts2055
@danroberts2055 6 лет назад
I had same problem, Blew out 4 of these wvc1200's Contacted KaiDeng and am sending them back for repair. It appears that they mosfets blew out after i disconnected the through cable from one inverter to the next. I was able to recreate the same behavior. I had 4 240w solar panels connected. Was disconnecting the through cable to test voltage and it blew. Also noticed that my AC voltage increases up to 263v AC then resets the inverter so it just keeps cycling on and off. Any idea's i would appreciate it.
@cimorelos
@cimorelos 5 лет назад
NEVER NEVER disconnect any solar inverter under load from AC ! The load rejection will produce an overvoltage surge that can easily Kill the output MOSFETs or the protection MOVs, before the Inverter can control it's power output. I installed a socket between the inverter and the switch, and before disconnecting the Inverter I plug in a dummy load in it ( Old electric heater, 1500W ). Plug in heater, open switch, wait 5 seconds, unplug. The load is bigger than the capacity of my solar panels (4 x 235W) and then The Inverter "Feels" the synchrony loss and the voltage drop, shutting itself down in a second. The resultant overcurrent is much less harmful than an overvoltage. This was installed after I toasted several Enphase inverters, "protecting" them from lighting storms and other issues. Cheers.
@textolite
@textolite Месяц назад
Good afternoon, can you tell me how to reset a micro-inverter WVC-800W-Life to factory settings? Reset WIFI settings? There is no reset button and I can’t log into the app.
@SureshKumar-nk2ok
@SureshKumar-nk2ok 4 года назад
always u can suspect MOSFET.in one of my circuit found fake components ,not bearing high voltages
@siddharthchand8691
@siddharthchand8691 7 лет назад
please ,, give some idea about simole design of the inverter which shares power of solar and grid simultaneously to load
@alvarobermudez7557
@alvarobermudez7557 7 лет назад
Hello Kedar. I have a problem with a WVC1200. When I connect the 4 solar panels of 300 Watts the red light bulb lights up. I just connect the output to the 220 Volt mains, the computer synchronizes and changes the led to green, but it only lasts a second and returns to the red and does not synchronize again. Which may be happening, check out the Mosfet and all are well. Thank you.
@FunnyFantasticFail
@FunnyFantasticFail 3 года назад
Are you sure that the dc input is in the range from 20-50v
@mattikhan5478
@mattikhan5478 Год назад
Hello sir how are you , you can tell the general fault of the grid tie inverter.
@mrcsalmeida
@mrcsalmeida 3 года назад
Hi, you can tell me what is the value of the fuse used in this inverter on the AC side and the Varistor. Best Regards
@oz93666
@oz93666 7 лет назад
Great video , Kedar ... I have one of these inverters , but my panels don't match , they're 100W 21V open circuit , I have to put 2 in series for the inverter to work ... so do I put 200W on each input , or would 400W be OK?
@HowToGuys
@HowToGuys 7 лет назад
+oz93666 I think 400watt will be OK .
@viptecvip1416
@viptecvip1416 8 лет назад
Friend you know say whether the inverter regulators can adjust the frequency to 60Hz AC 230? The place of the board where does this fit?
@gormgambahansen4732
@gormgambahansen4732 5 лет назад
Hi Kedar. Great video and help me a lot. My 3 pcs. WVC1200 all MosFet burns after only 5 month use and some of the cobber on the PCB also. I need a wiring schematic but the China company will or cannot give it to me. No support and just selling. :( Ps. the panels are right so must be bad quality inverters. .Anyone can help me ?.
@calimanmancali
@calimanmancali 6 лет назад
is it possible to change the input volt from 24v into 36v to match with solar panel. thanks
@miltdaugherty6965
@miltdaugherty6965 6 лет назад
I noticed the ac power wires are red, yellow, black. Is red hot, black neutral and yellow ground?
@tanimashraf
@tanimashraf 5 лет назад
Same thing happened to my GT inverter. DC terminals shorted for no reason. Now it won't display any LED. Were you able to repair this?
@rohanpujari4140
@rohanpujari4140 4 года назад
Heavy Price Competition and Technology upgrades has resulted into the compromise of components quality used in GTI... 99% the culprit is the Power Devices and the Diodes which get Shorted otherwise there is some problem with the Driver Ckt... if you can replace the Mosfets/IGBT and the Diodes and check the Driver ckt once maybe the Inverter can work fine again.
@renerivera2898
@renerivera2898 6 лет назад
Hi Kedar my name is Rene, i have this microinverter and before was working but now the green led permanent on, looks to be the microinverter is not synchronizing with the AC commercial network , what do you recommend to check?
@BrunoOliveiraBastos
@BrunoOliveiraBastos 4 года назад
Hi, i have this version, but i cant connect using the KDM System, but i think the rest its work fine, because i connect in others 2 one without problem, what can i do to solve the problem in microinverter to connect again ?
@vanbavt08ct
@vanbavt08ct 11 месяцев назад
Dear friend. I have microinverter 110v i can change it to 220v
@allinthefamiliy3122
@allinthefamiliy3122 7 лет назад
Hi Kedar, So the real reason that ruined your inverter is not know. Are you planning to buy a new one?.
@velascomike5800
@velascomike5800 6 лет назад
how can you say that the inverter is good but you bought it a couple of months ago and now its broken? so it's not last a year? how could it be? please reply sir I want to buy this kind of model
@DiYei
@DiYei 6 лет назад
do you have the value for the varistor on the lower left corner? marked as GND, on the left of the capacitors? my inverter has it missing!
@jaeinlee5879
@jaeinlee5879 7 лет назад
Does the wvc-1200 have the diode for preventing reverse current from solar pannel? I wonder if I need a distribution pannel to pass the electrical safety check
@johmemo
@johmemo 5 лет назад
Normally the diode is in the photovoltaic module. Make sure your module has the reverse current diode.
@tomasramirez2416
@tomasramirez2416 7 лет назад
Hi. K. Nimbalkar. I have the green light but it´s not energy produce. What happened?
@dacaolina
@dacaolina 8 лет назад
Hello , I hear a little noise, vibration looks like a transformer, is this normal? Thanks .
@jerryreyes345
@jerryreyes345 3 года назад
How to replace 15a fuse F2,, could be front, or the back side,,they are tiny.
5 лет назад
Dear, I have WVC-1200 and the operation is intermitate. The microinverter power on for some seconds and after disconect and restarting, all the time. How i can fix this?
@ansonguo8735
@ansonguo8735 4 года назад
I can help you find out why, ansonguo2355@gmail.com
@michaeldawson6309
@michaeldawson6309 5 лет назад
What is the alternative to using the WVC range ? Has anyone found an alternative that is more reliable ?
@salicosta5582
@salicosta5582 Год назад
This converter has a terrible construction. Why it has 50V capacitors when it should work with up to 60V. Build to fail. Mine worked 2 days at 50V and was burned.
@stonegold6992
@stonegold6992 7 месяцев назад
How can I reset wvc micro inverter
@Roadrunner48
@Roadrunner48 4 года назад
@ Kedar Nimbalkar, hello nice interesting video. Please can you tell me what kind of N-Channel Mosfet at the 230V side are used. I have the same inverter, but suddenly it stopped working and 8 of this Mosfet`s have a short. But I can`t read the type because the manufacturer cut away the lettering. Hope to hear from you soon !
@HowToGuys
@HowToGuys 4 года назад
Please check the description for details of mosfet.
@Roadrunner48
@Roadrunner48 4 года назад
@@HowToGuys How can I check the description if I don`t know the type of these Mosfet`s. For this reason I asked you !! If I don`t know the type I have to change all of these Mosfet`s because all of them must have the same specification. Always two of them are in parallel !
@lcwluthier1736
@lcwluthier1736 5 лет назад
This micro inverters do not have efficient surge protection in the both side of a FV System . Only fuses and sometimes insufficient components to suppress very short atmospheric outbreaks. Especially In the DC side as well AC surges arriving from the utility grid. Even in small projects when, is more practical using this kind of inverters, we have to include better protections in both side. Sometimes supposed savings can be a great loss. I love micro inverters but I always keep my eyes on this frailties.
@rosendoalmeida
@rosendoalmeida 5 лет назад
Luiz, há algo que possamos fazer para amenizar esses possíveis problemas de surtos que tanto danificam esses micro inversores WVC? Quando você diz que há um possível surtos que advêm do lado AC para o lado DC, o que gera isso?
@lcwluthier1736
@lcwluthier1736 5 лет назад
@@rosendoalmeida Podem ser de várias origens. Os surtos mais comuns são provocados por entradas de cargas de grande potência constantemente em toda a rede de distribuição da concessionária. Um exemplo bem nítido é quando um quarteirão todo fica sem energia quando um transformador de rua queima ou seus fusíveis se rompem. Quando esses problemas são resolvidos, ao retornar a energia elétrica para esse quarteirão, uma imensa carga entra ao mesmo tempo, surgindo um pico de tensão de elevada amplitude e de curta duração, que trafega pelos cabos que vão até os consumidores. Esses picos danificam eletrodésticos mais sensíveis, causando prejuízos aos consumidores. Surtos mais raros mas não menos destrutivos, são os surtos causados por descargas atmosféricas (raios). Essas descargas são de imensa intensidade e se induzem na rede de alta e baixa tensão, atingindo uma área muito maior que os anteriores citados. Para minimizar esses surtos, é importantíssimo que em suas instalações elétricas, não só as fotovoltaicas, você instale um bom aterramento (não confundir com o neutro da concessionária). No quadro de distribuição você terá, além das fases, um barramento onde o neutro será ligado (para tensões de 127 volts) e mais um outro barramento onde o cabo que sairá do aterramento que você deve construir, também será ligado. Inclua dispositivos de proteção de surtos (classe I e II) para serem ligados nas fases, no neutro e conectados nesse barramento de terra. Com isso você estará se protegendo dos surtos provenientes da rede AC nessas duas classes (surtos sistêmicos e por descarga atmosférica). Do lado DC a mesma coisa. Os módulos FV devem todos serem interligados no seu aterramento e instalados dois DPS's em cada polaridade no lado DC. Da mesma forma, conectar os terminais desses DPS's no mesmo aterramento. Isso pode reduzir muito os efeitos de todos os tipos de surtos, mas nunca eliminá-los 100%. Surtos provocados por descargas atmosféricas são de grande intensidade e em cerca de 25% deles, mesmo assim, o esquema de proteção pode falhar. A grande maioria é drenada pelo seu sistema de proteção contra surtos se o seu aterramento for eficiente (com resistência de terra menor que 10 ohms) e seus supressores de surtos forem de boa qualidade. Espero ter te ajudado.
@lcwluthier1736
@lcwluthier1736 5 лет назад
@@rosendoalmeida Desculpe se fui por demais extenso, mas vou simplificar um pouco mais. São dois tipos de surto: 1) Os provocados por descargas atmosféricas; 2) Os provocados pelos pelos próprios consumidores quando ocorre inturrupções e injeções abruptas de energia elétrica na rede de distribuição no momento da normalização do fornecimento. Você tem sempre que utilizar um aterramento elétrico confiável e construir dois quadros de proteção. Um para o lado AC e outro para o lado DC. Tem que utilizar DPS's específicos para essas duas classes de surto (Classe I e II). No lado AC se for uma instalação trifásica, utilizará 4 DPS's Classe II). Um dos lados dos 4 DPS's você conecta às fases e neutro e os outros lados desses mesmos DPS's, você conecta ao barramento onde o seu aterramento foi conectado. Da mesma forma do lado DC, você terá um outro barramento onde o seu aterramento será conectado. O cabo positivo ligado num dos DPS's e o negativo, ligado no outro DPS. Os terminais que restam desses DPS's, você liga no aterramento. Lembrar que do lado DC, você no caso do micro inversor desse vídeo, deverá ter uma tensão de no máximo 36 volts. Os DPS's para corrente contínua são específicos para essa aplicação. Em casos de associações de módulos FV em strings, você estará lidando com tensões que podem chegar a 500 volts ou mais. Nesses casos, consulte o fabricante dos DPS's para utilizar os modelos corretos. As tensões geradas pelas associações são naturalmente altas em função da potência de sua usina fotovoltaica e as descargas indiretas podem ultrapassar alguns kilovolts por intervalos de tempo curtíssimos, mas devastadores. Apesar do chinês ter dito que não sabe o que avariou os EXFET's do micro inversor, certamente o surto veio do lado DC (descarga atmosférica).
@dhadumia
@dhadumia 5 лет назад
Good explanation. Thank you.
@desmonddaniels4584
@desmonddaniels4584 3 года назад
Dear, I bought micro inverters 127V , but I need 220V. I cannot return these micro inverters. Do you know how these micro inverters can be changed into 220V?
@HowToGuys
@HowToGuys 3 года назад
if you need to change the inverter voltage you also need to switch the Transformers and other power handling components so I would rather not touch anything
@jaeinlee5879
@jaeinlee5879 7 лет назад
i have some question for youi use wvc-600 220v/50hzbut my country(korea) use 220v/60hz AC PWRso, i'm afraid that it make a trouble with my equipment(refrigator, tv, etc..)how can i change frequency from 50hz to 60hzor, it's ok to use wvc-600 continuous.
@HowToGuys
@HowToGuys 7 лет назад
+jaein lee inverter changes frequency automatically, you don't need to do anything.
@hollywoodj500
@hollywoodj500 8 лет назад
Hi Kedar, how do you connect this inverter here into 240 volts system with 2 hot lines, neutral and a ground line. This inverter here only has 3 wires one is hot line and neutral and a ground wire. Please right back. This is Hollywood here.
@johnd01
@johnd01 7 лет назад
You have leg1 and leg2 + ground/neutral In the United States Leg1 and Leg2 have 120 votes to neutral but 240 volts Leg to leg. A 240 vote circuit is from leg to leg while 120 volts leg to neutral.
@donaldwelker1952
@donaldwelker1952 7 лет назад
Carl J can you possibly help me out here I am trying to figure out the same thing on these inverters I actually ordered one that is stamped on it 240-volt but it's still only three wire they're not showing me to hotlines
@johnd01
@johnd01 7 лет назад
One wire is connected to the case it is ground not neutral. 240 does not need neutral. 2 wires connect across your 240 volt connection to your panel.
@AbhishekKumar1902
@AbhishekKumar1902 6 лет назад
is it fixed, what was the fix?
@hrushikeshkuwlekar5301
@hrushikeshkuwlekar5301 6 лет назад
We imported enphase and sma grid tie micro inverter from USA to India it is not working showing frequency not matching
@mdumar9149
@mdumar9149 7 лет назад
hello my friends you in India where can I buy grid tie inveterate just replying me thanks
@chandhrenb335
@chandhrenb335 3 года назад
Trying reaching out for loom solar dealers... Near your locality.... They will install
@WallyboisWoodworking
@WallyboisWoodworking 6 лет назад
Nice vid.. i have the same inverters but one is flashing red/green continuously do you have any idea why? Xx
@truthexposed9916
@truthexposed9916 6 лет назад
Yeah, because its CHEAP SHIT.
@hrushikeshkuwlekar5301
@hrushikeshkuwlekar5301 6 лет назад
Can u tell how to adjust the output ac frequency from 60 hz to 50 hz
@HowToGuys
@HowToGuys 6 лет назад
+HRUSHIKESH KUWLEKAR its automatic you don't need to do anything.
@dominik8040
@dominik8040 8 лет назад
Can You write the all names of ic with more than 2 legs? You can also post macro pictures. It will be helpful for reverse engineering of this converter. I am mainly interested in current measurement, DC converter control, sinewave controller, mosfet drivers.
@HowToGuys
@HowToGuys 8 лет назад
please check most of the parts listed in the description below , I will upload pictures soon.
@dominik8040
@dominik8040 8 лет назад
+Kedar Nimbalkar there is nothing more than main uC and mosfets and diode. I am interested in logic part of this converter.
@dominik8040
@dominik8040 8 лет назад
+Против Глобал I am interested in designing converters. I know this documents. I am interested how it was designed in real consumer electronics. Which ics they used.
@dominik8040
@dominik8040 8 лет назад
+Против Глобал I am interested in designing converters. I know this documents. I am interested how it was designed in real consumer electronics. Which ics they used.
@user-zf4uq7eh1i
@user-zf4uq7eh1i 3 года назад
I have micro inverter 1400w one component is damage can you tell me what is this i don't know much on pcb
@jerryreyes345
@jerryreyes345 3 года назад
Check the tiny 15a integrated fuse, they have 4 for each Input
@franciscodias2584
@franciscodias2584 6 лет назад
Hi, my name is Francisco, I'm from Brazil. I bought an inverter of the same model as yours on eBay, my inverter is of a newer model (with small differences), but I think that the MosFet are the same. When I connected the inverter to test with a solar panel of 330W, it worked only about 15min. Then the same fault occurred as your inverter, short on the 4 DC inputs and no AC voltage. Do you fix your inverter? Do you have the electronic schematic of this inverter? Can you help me? Tks...
@cassiobraga1758
@cassiobraga1758 6 лет назад
Hi Francisco, have you solved the problem? I too have the similar microinverter and experiencied this behavior. I was observing the issue and concluded, at some level of certainty, that these microvinverter can not work with hi power PV, in my case they are of 325w. When the sun is at high peak, microinverter becomes very hot and stop to work. Now I´m looking for a new one capable to manage my PV set, but I have not found it.
@rosendoalmeida
@rosendoalmeida 5 лет назад
Olá Francisco. Você conseguiu solucionar o problema do teu inversor?
@ismurdegus
@ismurdegus 7 лет назад
Hi guys my inverter just fail yesterday.
@jessecates5091
@jessecates5091 6 лет назад
Can someone direct me to a company that I can send my WRC inverters for repair. I have two that my solar provider cannot repair because they were burned by high or low voltage and I have two more that are working but not efficiently , the green light is constantly flickering and never locks into solid green. Thanks. Shipping to another country shouldn't be a problem if necessary. Thanks
@Patrick-kt8em
@Patrick-kt8em 2 года назад
Does anyone know if these Chinese inverters actually feature four separate mppts or is it simply configured in parallel internally?
@HowToGuys
@HowToGuys 2 года назад
Just parellel internally
@Patrick-kt8em
@Patrick-kt8em 2 года назад
@@HowToGuys are you aware of any micro inverters with individual mppts? I know hoymiles and huayu, but both are very expensive and/or hard to get these days
@PRESLEYVENDA
@PRESLEYVENDA 6 лет назад
PDF Maysun 1200Kwp drive.google.com/file/d/185Mqi7tu3GDq7NjytniDdnBKxY3zgw7v/view?usp=drivesdk
@motokista
@motokista 4 года назад
fix this inverter ?
@GOWTHAMKRISHGowthamShanmugaraj
what's the difference between ground and earth ground??
@HowToGuys
@HowToGuys 7 лет назад
+GOWTHAM SHANMUGARAJ (Gowtham krish) earth ground is ac ground, ground is DC negative .
@GOWTHAMKRISHGowthamShanmugaraj
Ok...now I understand
@------country-boy-------
@------country-boy------- 2 года назад
Thankyou for this video. I almost bought one of those pieces of shit.
@ogmm
@ogmm 7 лет назад
I saw that all the negative wires are connected together(black ones). Can someone confirm if positive(red ones) also are connected together. I need to know due i will attach 250w panels (5 pieces) so i will need to connect 2 panels in one port and 1 on each other.total 1250w
@stephendsjones
@stephendsjones 5 лет назад
The positives are separate
@cimorelos
@cimorelos 4 года назад
In the WVC 600 the 2 positives are connected together internally (Not at the same point but by the motherboard). I think that in the WVC 1200 the 4 inputs are together also. Check with an ohmmeter.
@easterndigital2691
@easterndigital2691 Год назад
The positive are connected together, with a fuse to the common positive.
@allinthefamiliy3122
@allinthefamiliy3122 3 года назад
Question: does the WVC has a timeout when switching in again after a timeout. Question: does the WVC has Voltage High and low protection when grid voltage go outside the voltage thresholds Question: my WVC has a poweline interface, does anyone has an idea what PLC module I need to communicate with it and what the API Command are to request for data. I want to connect it to an Arduino type controller Question: can anyone with a modem show a picture from what is inside and identify the power line modem used. Question: there are other 4channel Chinese CCP cheep inverters for sale is there anyone who has experience with these. Question: Does anyone know a good economic replacement for this STD13NM60ND to cut the power loss and reduce the case temperature?
@CHARTMOTOR
@CHARTMOTOR 7 лет назад
How much?
@frankboddeke
@frankboddeke 8 лет назад
any idea how the power line communication is done?
@HowToGuys
@HowToGuys 8 лет назад
+Frank Boddeke Inside inverter there is a dedicated wireless chip ,which sends measured voltage and current to the wvc modem .
@frankboddeke
@frankboddeke 8 лет назад
thanks. do you know what part number or detail picture?
@binhengzhou7610
@binhengzhou7610 8 лет назад
i know
@pietdepad4103
@pietdepad4103 8 лет назад
Hi frank are you dutch?. I'm interested in the API of the WVC do you have information about that
@frankboddeke
@frankboddeke 8 лет назад
yes i am. i did get a bare power-line transceiver (BW-EP09), same as in the wvc, but have not hooked it up yet...
@2002dilip
@2002dilip 8 лет назад
sandip
@arunkrajendrapretheesh9433
@arunkrajendrapretheesh9433 5 лет назад
?
@andyinskintown
@andyinskintown 9 месяцев назад
I have WVC-1600 grid tie solar micro inverters it’s works for one day then red light the next not getting much help from china
@user-cn4ti1du8n
@user-cn4ti1du8n Год назад
this inverter is use less. do not boy it. there are better at a similar price on the marked. It is lausy designed. A 1 year electro mecanic studed can do it better.
@SatyajitRoy2048
@SatyajitRoy2048 6 лет назад
Is that fuse or current sense resistor? Thumbs down. You need to check gate of the mosfet. Seems like you're beginner in this domain.
Далее
Lab Update #78: Repairing Solar Micro Inverters
10:29
Просмотров 2,9 тыс.
Failed Enecsys 360w solar microinverter teardown (018)
15:54
СЛАДКОЕЖКИ ПОЙМУТ😁@andrey.grechka
00:11
How to repair grid tie inverter 1000W
6:50
Просмотров 35 тыс.
A LOOK INSIDE A 100KW 3 PHASE SOLAR GRID TIE INVERTER
10:29
GRID TIE INVERTERS | ECOWORTHY WVC-600
25:20
Просмотров 105 тыс.
How to Repair 2000W Sine Inverter
21:23
Просмотров 473 тыс.