Hello my name is Chris and I will be posting videos about the cool stuff I see out in the field of HVACR. A little bit about my self, I've been involved in the trade for over 15 years and I will tell you right now that I do not know it all, this trade is constantly evolving and new technology is coming out every day. I am based out of Southern California and I mainly work in restaurants. If you have any questions or even suggestions for videos please don't hesitate to email me at HVACRVIDEOS@GMAIL.COM.
To support my channel please visit Patreon at www.patreon.com/Hvacrvideos
For Optimizing my videos I use Tube Buddy www.tubebuddy.com/HVACRVIDEOS
About the conversion to 407c. Thought that was the solution for r22 systems that people dont want to replace, but doesn't work qith fixed orifice vs changing txvs?
To protect the solenoid Valve and head pressure control valve from getting hot when braising, you could bolt them on like the liquid line dryer and then no more Wet rag.
I think all refrigeration condensing units should anti short cycle timer put in when the system is on a pump down and auto reset head pressure switches 💯
Having Y1 & Y2 jumpered can totally explain why the original fuses were blowing - both compressors starting at the same time is a huge inrush current and the circuit was never sized for concurrent startup on those motors
Here in germany the law! says, you have to usw for non solid copper wire these 'nuts' (google says: "wire nuts" -lol ) (you have to crimp on ) - cable shoes?
I didn't see if you test the fan motor amp if this consuming more amp or running low , maybe the speed of those fan can be changed , i think the Air flow issue is because the fan motor is was running low like a have to be .., the package was Cooling properly before so why to blame the duct ??
I not expert but I’m handyman some times I recibe a Coll s from local restaurants I have fix many tings to them I did change a motor on. One exhaust fan on the kitchen but I have tink that I under charge for all I do Like you said they Coll on emergency so I like to know how moch to charge I did all you just did there check for any problems on wires or sensors or bad contacts took me like 5 hrs to do it because it the shaft on the motor was very stock and it was 100 degree temperature on the roof So can you give me one idea of charging. Price on hrs Im in Texas I will very tankful
Someday your channel is going to have millions of subscribers! Keep doing what your doing and your going to get there. You are my #1 favorite channel to watch and you are amazing!
The fan blade with the set screw that wouldn't tighten. Could abandon the set screw and drill and tap a new hole new set screw. Probably a 1/4 20 tap and a37 drill bit. But you got it thats what counts
@ 2:44 Ahhh Chris, my dude, you forgot to thaw out a little “ice” on that beard bud. Lol😅 😂 Big picture diagnoses might include some Just For Men aka soy sauce on the old face fuzz. I tease bud, I tease…. Thanks for all the great vids
Question. I have a Goodman 2.5 Ton, 13.4 SEER2 Self-Contained Packaged Air Conditioner . If i use the ac portion to cool the house ( 1,450 square feet ) and then dont use for a day or two . It snells horrible when i use it again. It smells like rotten fish . Any idea what causes this ?
Yeah the compressor had been in the wars that scroll looked well cooked looking at the black paint work it was like a matt finish instead of a nice shiny finish 🥵
It didn't pick up trough the contactor because u had system off which you would then press the contactor manually to know you had a down control fault on that compressor I think chris
Wow. I worked at a certain red head’s and had similar where dudes climbed the outside of the building on top of roof and stole copper everywhere visible and even the exhaust fans they tore off and I guess scrapped. Crazy how they’d probably get paid more if they rough demo’d as a job lol. Like the amount of work put in to… what couple hundred max?