Тёмный
Slic-Rock
Slic-Rock
Slic-Rock
Подписаться
Комментарии
@connes5805
@connes5805 Месяц назад
Hallo, ich habe jetzt auch das gleiche Problem, haben Sie selber repariert? Bitte melden Sie sich
@Slic-Rock
@Slic-Rock Месяц назад
Ich ziehe die Handbremse auf dem Stellplatz nicht mehr so stark an
@BrokeLifeEU
@BrokeLifeEU 6 месяцев назад
This is a very cool project!
@m.g.4581
@m.g.4581 Год назад
was war es habe das gleiche problem
@Slic-Rock
@Slic-Rock Год назад
Fehlkonstruktion Fiat
@filipesantos7407
@filipesantos7407 Год назад
I have same problem Resolution?
@Tobia-qy9ph
@Tobia-qy9ph 7 месяцев назад
yes, vent.
@jarus72
@jarus72 Год назад
Ja w moim VU+ duo mam napięcie tylko 5v reszta nie ma.
@technomama1
@technomama1 2 года назад
fantastic. Could you please guess KW or Hp power? And, how many rpm max?
@robbiebouchart1551
@robbiebouchart1551 2 года назад
How many ponies??
@sabrinakonig6988
@sabrinakonig6988 2 года назад
Ich bitte um Hilfe wir haben auch das Problem
@ca.3369
@ca.3369 2 года назад
Can I handle 60V or 72V?
@MarcosElias
@MarcosElias 3 года назад
the 3 possible positions for placing hall sensors for an 8-pole alternator is every 15 degrees, or every 30 degrees, or every 60 degrees exactly. Depending on the chosen position, it generates a different code sequence. But in all these positions they generate 6 codes for the module
@Slic-Rock
@Slic-Rock 3 года назад
Do you think I can confirm the theory to add 3 resistors 1R 10 W In the 3phases to see if the current drops and the controller don't cut out?
@Slic-Rock
@Slic-Rock 3 года назад
ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-LnO_8D1NlPE.html Here a link how I have tested the sensor system
@MarcosElias
@MarcosElias 3 года назад
You need to make sure that when the pole aligns with each of the six combinations of the phases it generates a different code. Example: +u-v = 011 -v+w = ​​010 +w-u = 110 -u+v = 100 +v-w = 101 -w+u = 001 You also need to make sure that the string of wires, usually yellow, green and blue are in the same sequence as the wires of the sensors
@MarcosElias
@MarcosElias 3 года назад
i have a chance. Its reduction is still small, the motor needs to apply too much force to start then the protection of the controller stops the operation.
@cristearodinel
@cristearodinel 3 года назад
Salut...Date tehnice despre cum se face ,poți să dai? Multumesc frumos .
@azertaieb442
@azertaieb442 3 года назад
Is that work without hall sensor ?
@Slic-Rock
@Slic-Rock 3 года назад
Yes it works without hall, on EMF Feedback. But your controller has to be able to support sensorless motors.
@azertaieb442
@azertaieb442 3 года назад
@@Slic-Rock thank you so muche
@Slic-Rock
@Slic-Rock 3 года назад
Ordentlich Entlüften. Steht die Therme auf dem Dach ist das Entlüften immer problematisch. Dann Wasserdruck auf 2Bar stellen. Fehlercode 2 Temperatur Fehler. Wenn alle Heizkörper geschlossen sind ist der Temperaturunterschied zu klein zwischen Vor und Rücklauf. Das ist wohl eine Macke dieser Gerate
@jurgenjanke4848
@jurgenjanke4848 Год назад
Danke
@Andreas-sb8wb
@Andreas-sb8wb 3 года назад
buderus logamax plus gb112. Bei mir genau dasselbe. Gibts da eine Lösung?
@Slic-Rock
@Slic-Rock 4 года назад
Ja Therme hatte zu wenig Wasserdruck und richtig entlüften
@MichaelKean
@MichaelKean 5 лет назад
How did you resolve this?