@Mboliaka 9 дней назад
Thank you very much. I have two Growatt ES 6000 plus, I want to put them in parallel now I wonder if I can connect the BMS to which Growatt?. Thank you in advance
@Mboliaka
@Mboliaka 9 дней назад
Thank you very much. I have two Growatt ES 6000 plus, I want to put them in parallel now I wonder if I can connect the BMS to which Growatt?. Thank you in advance
@golden4o
@golden4o 9 дней назад
@@Mboliaka It doesn't matter. If the inverters are in parallel you can connect the BMS to either of them.
@Mboliaka
@Mboliaka 9 дней назад
@@golden4o Thank you
@Mboliaka
@Mboliaka 9 дней назад
Hello Sir, when we put 3 Growatt in parallel. In which Growatt should we put the BMS as long as we do not have a Hub
@Mboliaka
@Mboliaka 9 дней назад
Thank you very much. I have two Growatt ES 6000 plus, I want to put them in parallel now I wonder if I can connect the BMS to which Growatt?. Thank you in advance
@Mboliaka
@Mboliaka 9 дней назад
Hello Sir, when we put 3 Growatt in parallel. In which Growatt should we put the BMS as long as we do not have a Hub
@golden4o
@golden4o 9 дней назад
Check the communication ports of each inverter. If you have the new version the ports will be BMS and RS485. In that case you connect the batterie to the Master inverter (Probably it doesn't matter in which one you connect them but I prefer the Master one). If the ports are CAN and RS485 you will need a Hub. (Or you can make your own cable.)
@Chand-c3o
@Chand-c3o 11 дней назад
Required a 5 kw 3 phase solar inverter send me contact details
@user-wb6qf7ht1v
@user-wb6qf7ht1v 14 дней назад
Hi, I have a question... I have a 3-phase 240 V system in my home and two Growatt SPF 6000+ inverters. Can I use those on the 2 phases of my system leaving the 3rd phase intact? I have seen diagrams for seting up and connecting 3 inverters (one on each phase) but no only 2. Would that cause any problems? Thank you!
@golden4o
@golden4o 13 дней назад
@@user-wb6qf7ht1v I think you can do that. Try setting them up like a 3 phase system (without the 3rd phase). If this doesn't work, you can install the inverters as they are in separate systems with only one phase. (Two single phase systems) And the third phase you leave it as it is now. I'm m not 100% sure if this will work. Pretty sure it will, but still, you have to test it...
@user-wb6qf7ht1v
@user-wb6qf7ht1v 12 дней назад
@@golden4o thank you!
@nikolarangelov4716
@nikolarangelov4716 23 дня назад
Тоя белия прелюд ми 'ареса най-много!
@ciprianpavia
@ciprianpavia 3 месяца назад
Can you limit the %charging (ex. limit to 80%) from the growatt app?
@golden4o
@golden4o 3 месяца назад
No, the limit has to be set on the car.
@angelkm2599
@angelkm2599 3 месяца назад
hello, I have an identical installation with 3 inverters 5 kW mounted in parallel with a total single-phase output of 45 kw but I have a three-phase public network subscription of 15A per phase, I would like to know if it is possible to make the network injection of the 3 phases with one phase per inverter
@golden4o
@golden4o 3 месяца назад
Yes, you can make the inverters work in 3 phases and connect each phase of the residential network to the inverters. You can check the manual on how exactly you can connect them. I'm planning to switch to 3 phases as well as I have 3 phases coming to my house. Before you do that please make sure to balance each phase in your house. Because with 3 inverters you will have 5KW on each phase. (Total 15KW on the 3 phases)
@angelkm2599
@angelkm2599 3 месяца назад
@@golden4o Thank you for your feedback but I want to stay in parallel mono and inject each phase in an inverter thank you
@golden4o
@golden4o 3 месяца назад
@@angelkm2599 If you want to stay on single phase with the inverters and inject, you can only do that with one of the 3 phases that are coming to your house. Just grab one of the phases and connect it to the input of each inverter.
@angelkm2599
@angelkm2599 3 месяца назад
​@@golden4o there is a risk of connecting the 3 phases if why, because each inverter normally sends its current, so I do not understand the risk and thank you again for your return
@golden4o
@golden4o 3 месяца назад
@@angelkm2599 The inverters cannot convert 3 phases into a single phase. No inverter can do that (as far as I know). So in order to use 3 phases, your inverters must be in 3 phase mode. If they are in single phase mode, you can only input single phase.
@exploretech_ng
@exploretech_ng 4 месяца назад
Please can I parrelle SPH 10000 growatts?
@golden4o
@golden4o 4 месяца назад
I'm not sure. You should check the manual for your exact model.
@zoumanatraore972
@zoumanatraore972 4 месяца назад
C'est génial et bon boulot ❤ mais 6 convertisseur en parallèle comment faire cet programmation.
@eddywouters3044
@eddywouters3044 4 месяца назад
Setting 23? When you are using single phase with 3 inverters in parallel the manual says to set it to PAL instead of SIG. But then it gives me a fault. What is your opinion? I am using exactly the same combination as your system...
@golden4o
@golden4o 4 месяца назад
I cannot access Setting 23, from 21 it jumps to 28. My guess is that the communication between the inverters is not properly connected.
@venceslavuzunov1370
@venceslavuzunov1370 4 месяца назад
Добра работа!
@goodwhiskyjerome3902
@goodwhiskyjerome3902 5 месяцев назад
Hello, super video ! You have 4 ROSEN SOLAR batteries and what are the 3 others? Thanks. Jerome.
@golden4o
@golden4o 5 месяцев назад
The other 3 are made from a local company.
@valentinvsk4621
@valentinvsk4621 Месяц назад
@@golden4o can you bank different Ah battery in the same bank? or how are you doing it?
@golden4o
@golden4o Месяц назад
@@valentinvsk4621 What do you mean with bank? You can connect different Ah packs (batteries) in one system. But you cannot connect different Ah cells in one pack (battery). I have 4 batteries that are 200Ah and 3 that are 230Ah
@valentinvsk4621
@valentinvsk4621 Месяц назад
@@golden4o so I have an 85Ah battery and a 200Ah battery,both are from the same brand, but the seller said I cannot parrallel them because of the different capacities.I would like to use both on them on my system.Would it be possible? Thanks
@golden4o
@golden4o Месяц назад
@@valentinvsk4621 Technically you can parrallel them, but one of the batteries will be depleted long before the other and if you have a big load the BMS of the other might shut off the power. That is why it is not recommended to parrallel them.
@senogamoses5319
@senogamoses5319 5 месяцев назад
Where can i get those busbars ?
@golden4o
@golden4o 5 месяцев назад
I was able to purchase the last two in stock from Amazon UK.
@senogamoses5319
@senogamoses5319 5 месяцев назад
Link ?
@golden4o
@golden4o 5 месяцев назад
Gloaso 600 Amp Bus Bar 300V AC /... www.amazon.co.uk/dp/B0B2JQR4VP?ref=ppx_pop_mob_ap_share
@freshia2008
@freshia2008 5 месяцев назад
Sir what is the Max. PV input current of this inverter ?
@golden4o
@golden4o 5 месяцев назад
18 Amps
@poleznoszdrave
@poleznoszdrave 7 месяцев назад
Браво! Много полезно видео!
@LX777
@LX777 7 месяцев назад
Very useful and well done. Thank you
@nutterknoll69
@nutterknoll69 7 месяцев назад
Thanks for your efforts. You are doing a good job explaining things, especially considering English is not your native language. You are easy to understand. Greetings from Australia. I have 2 of those inverters, still in their boxes. The cost of batteries is the real killer!
@marcinbabowicz341
@marcinbabowicz341 8 месяцев назад
Hi, can you tell me how to set up BMS protocol with lifepo4 baterry?
@golden4o
@golden4o 7 месяцев назад
I will try to make another video for that.
@kirkdis
@kirkdis 8 месяцев назад
Nice video, well done and beautifully explained about the good practices and also the bad ones. Keep the work going on for your off grid setup, by the way how much battery capacity are you using?
@golden4o
@golden4o 8 месяцев назад
Thank you. My batteries are about 70KWh (7x200-230ah)
@andrewluke1974
@andrewluke1974 10 месяцев назад
I need ur complete video of the installation of the 3 grow watt inverter
@golden4o
@golden4o 10 месяцев назад
Next week I will be reinstalling them. I will try to make more informative video.
@sanitarcho
@sanitarcho 11 месяцев назад
Би ли пуснал една снимка на буксата с 3-те кабелчета и в кой порт я вкарваш на инвертора. BMS или RS-485
@SurvivingWithFanty
@SurvivingWithFanty Год назад
Are you happy with the charger? Is it any good?
@golden4o
@golden4o Год назад
Yes. The charger is great. The only downside is for Teslas. There is no unlock button on the handle and I have to unlock the port from my phone or the car.
@SurvivingWithFanty
@SurvivingWithFanty Год назад
Alright thanks! I've ordered mine yesterday so wish me luck :D
@ruslanbezushko9448
@ruslanbezushko9448 Год назад
Інформації нуль... Щось якось і через щось Клятий інвертор не хоче з батареєю працювати... Хоч би десь знайти інформацію про режими пункта 36...
@jarrettvick4571
@jarrettvick4571 Год назад
Show how you connect it to the battery! All I learned is cut your cable into and hook it to the inverter and battery.
@EduardoRodriguezRocks
@EduardoRodriguezRocks Год назад
I am pretty sure you only connect to master of course is good to connect the 3 just because you. Don’t need to worry about startup order
@nicolaspanzarella2833
@nicolaspanzarella2833 Год назад
Good morning, Sir, I am contacting you because I am really lost in the commissioning of a Growatt Thor 22 as-p... I am an engineer in Belgium and I have a small renewable energy company! I have no answer from the Growatt technical department. I have already spent hours on ShinePhone and ShineTools but I cannot add and make the commissioning of this E-V Charger! LinkdIn is my last hope to contact Growatt and try to get help... I hope you can help me or direct me to someone who can help me. In advance I would like to thank you. Sincerely yours.
@CHloras
@CHloras Год назад
Can you show cable pin out?
@sujeewae6599
@sujeewae6599 Год назад
Great info. I just need to know whats the pin order 4th pin CAN H , 5th pin CAN L 6th pin Ground in the Growatt 5000es side. Is ground pin matters? My battery ground pins are PIN 2, PIN 7 CAN L and CAN H are correctly aligned
@robbyrock-drummer
@robbyrock-drummer Год назад
Can you explain how you connected 3 inverters to 4 batteries? Someone told me: Growatt SPF 5000 ES in parallel its only need to connect the main inverter to batteries in parallel. The Growatt SPF 5000 ES parallel cable will get the needed data from the slave inverters.
@ketiow09
@ketiow09 Год назад
how did you connect the pins in the plug on both sides?
@samago20
@samago20 Год назад
Do you have the link for the CT meter?
@golden4o
@golden4o Год назад
Unfortunately no. I got the Charget and the clamp in one package and I cannot see any markings on it. But, I'm pretty sure that you can use any CT clamp for AC.
@paolonocco7861
@paolonocco7861 Месяц назад
@@golden4o tc 2000:1
@komjazz
@komjazz Год назад
Hello, I got the Thor EV charger like yours now. My question is what is the spec of the CT that you use?
@juanpablolongo
@juanpablolongo Год назад
Hi, nice video. The clam you are showing on the minute 3:49 to check the power consume from the house, come by default with the charger, or do you need to buy that apart?can you send me the model of that?
@golden4o
@golden4o Год назад
You have to buy that separately. Any AC clamp should work (for the rated AMPs)
@sephassimiyu433
@sephassimiyu433 Год назад
Hi
@juanpablolongo
@juanpablolongo Год назад
Hi, thanks for your videos. The EC charger works without wifi? This have Bluetooth too? I need to install the charger in a parking with no internet. Regards.
@mjmj-xj6jh
@mjmj-xj6jh Год назад
Thanks for the video! Is it possible to setup 3-phase system from the same 3 growatt inverters?
@golden4o
@golden4o Год назад
Yes. You can do that by changing the settings of the inverters.
@mjmj-xj6jh
@mjmj-xj6jh Год назад
@@golden4o thank you!
@joergmargraf4290
@joergmargraf4290 Год назад
Zero Information here.
@allanstrand638
@allanstrand638 Год назад
What order in the cable then aka Color order? Close picture on the cable head to see the colour order= Null modem? RJ45 head Write colour to the left nr2 colour etc due to missing the cable !
@alexddumitru
@alexddumitru 2 года назад
Hi, how does PV linkage work? Also load balancing, did it happen to shut down your fuzes?
@golden4o
@golden4o Год назад
I was unable to test the PV linkage. I need to get more sensors for 3 phase system. My main fuses are 63A and the one going to the charger is 50A so no issues there.
@komjazz
@komjazz Год назад
Thank you for your video, did you use 1 phase 7kw? Why 3 phases?
@golden4o
@golden4o Год назад
@@komjazz I have only one phase but it is splited on three conductors. No idea why I don't have 3phase input. So that's why I use single phase charger. In order to use pv linkage I have to monitor those three conductors.
@komjazz
@komjazz Год назад
Hi, thank you for your reply, i have SPF5000 like yours, would love to see how it works. So little information on the internet now. 🙏
@christiankulmann3325
@christiankulmann3325 2 года назад
Small hint: Energy cannot be saved. So if I want to boil my water, I always have to use the same amount of energy for one liter. Christian's method relies on a longer period of time with less power in order to be able to use the power provided by the PV as efficiently as possible - so consumption peaks are intercepted. In the end, the energy consumption should even be (slightly) higher due to the interposition of the dimmer, but it doesn't matter, since more efficient coverage by the PV system and therefore better use of the self-generated energy .......... .... 🌞 ................ Solar Mini PV Tip ... Winter & Camping. A boiler and other hungry electricity consumers can be infinitely dimmed using the "5000W dimmer". Ebay €7. I run 5 dimmers in parallel on an 850W inverter. Kettle 2.2KW at 150W runs 12 hours a day, so the water is always hot. The room is also nicely heated. 2.5KW washing machine runs in parallel with dimmed to 200...400W. Iron, dishwasher, oven, electric heater, coffee machine, all internal heating are throttled with me. Videos on my channel ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-eC2olbCBhh0.html The inverter stays cool, quiet and the MOSFETs + (battery) remain intact because no extreme current peaks arrive at the inverter. Now every Mini PV Inverter is enough to sell large devices. So, with the dimmer, all internal heaters/devices can be converted into base load devices that stay almost permanently ON, drawing very little current directly from the PV. With a wattmeter / energy cost measuring device you can then measure this perfectly in order to optimally set the dimmer. With the dimmer, self-sufficiency will now increase from 20% to almost 95% in summer, which means a huge breakthrough. The prerequisite is that you have at least a small balcony power station, and you don’t need an expensive battery either. Example of a kettle: Without a dimmer, the 2500W - 600W PV system needs = 1900W, which you have to pay more for. If I turn the kettle down to 600W with a dimmer, then every weak PV system can now supply each consumer independently and independently, because the 2500W kettle becomes a 600W kettle thanks to the dimmer. Magic... The 2000W e-heater becomes a 500W e-heater with a dimmer, which can run 12 hours a day free of charge via PV. ru-vid.com/video/%D0%B2%D0%B8%D0%B4%D0%B5%D0%BE-QbLWDbJi6ew.html . The 4000W oven is also tamed. Not the solar systems have to grow, but the consumers just have to drop by 75%, which is sooo easy with the dimmer. are you convinced now I have already switched my entire household to dimmers. Please have a look at my channel. LG, Christian ................................
@gabriellavine3227
@gabriellavine3227 2 года назад
Hello: I have 16 model: 3.2 v 280 Ah batteries along with “Overkill Solar” battery management system. I have cut the wood that I will be using to construct the bottom of my wooden frame to hold all 16 batteries. I would like to purchase battery tape to provide support to all 16 batteries and to secure the battery terminals. After I’ve connected each one of the BMS leads to the positive terminals which includes the black lead to the negative terminal and the red lead to the positive terminal, I’m not sure what battery wires and devices should I use to connect two Growatts 3,000 kilo watt inverters to the 16 batteries. Would you do a video on this or provide an answer on this? Regards, Gabriel L.
@LX777
@LX777 2 года назад
Those t-shirt change faster than the car :D
@EduardoRodriguezRocks
@EduardoRodriguezRocks 2 года назад
I am pretty sure is the same cable than the regular utp patch panels.
@LX777
@LX777 2 года назад
Whole 2 videos this year. Calm down a little 😃
@khalilsalam1500
@khalilsalam1500 2 года назад
in order do not cut the cable can i use a lan hub thank you
@golden4o
@golden4o 2 года назад
I haven't tried with a lan hub. But I don't think It will work.
@martinusstrydom8518
@martinusstrydom8518 2 года назад
Show us the cable pinouts
@adeebhaddad7618
@adeebhaddad7618 2 года назад
Hello sir I've the same problem 6 rosen lithium battery with 2 growatt in parallel Could you please inform me the way you have connected the batteries with the inverters? How did you connect the rj45 connector?
@omegaart
@omegaart 2 года назад
Ще пуснеш ли настройките за паралел и за батериите които си сложил на инверторите , правя подобна система само че с 2 инвертора в паралел и 10kw lifepo4. Благодаря