In the video we are going through my 3x Growatt inverter settings.
The system is with 3x Growatt SPF5000ES inverters working in parallel in a single phase with 7 batteries.
#SPF5000ES #growattsettings #diysolar

Опубликовано:

 

28 авг 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 16   
@LX777
@LX777 7 месяцев назад
Very useful and well done. Thank you
@poleznoszdrave
@poleznoszdrave 7 месяцев назад
Браво! Много полезно видео!
@user-wb6qf7ht1v
@user-wb6qf7ht1v 14 дней назад
Hi, I have a question... I have a 3-phase 240 V system in my home and two Growatt SPF 6000+ inverters. Can I use those on the 2 phases of my system leaving the 3rd phase intact? I have seen diagrams for seting up and connecting 3 inverters (one on each phase) but no only 2. Would that cause any problems? Thank you!
@golden4o
@golden4o 13 дней назад
@@user-wb6qf7ht1v I think you can do that. Try setting them up like a 3 phase system (without the 3rd phase). If this doesn't work, you can install the inverters as they are in separate systems with only one phase. (Two single phase systems) And the third phase you leave it as it is now. I'm m not 100% sure if this will work. Pretty sure it will, but still, you have to test it...
@user-wb6qf7ht1v
@user-wb6qf7ht1v 12 дней назад
@@golden4o thank you!
@eddywouters3044
@eddywouters3044 4 месяца назад
Setting 23? When you are using single phase with 3 inverters in parallel the manual says to set it to PAL instead of SIG. But then it gives me a fault. What is your opinion? I am using exactly the same combination as your system...
@golden4o
@golden4o 4 месяца назад
I cannot access Setting 23, from 21 it jumps to 28. My guess is that the communication between the inverters is not properly connected.
@angelkm2599
@angelkm2599 3 месяца назад
hello, I have an identical installation with 3 inverters 5 kW mounted in parallel with a total single-phase output of 45 kw but I have a three-phase public network subscription of 15A per phase, I would like to know if it is possible to make the network injection of the 3 phases with one phase per inverter
@golden4o
@golden4o 3 месяца назад
Yes, you can make the inverters work in 3 phases and connect each phase of the residential network to the inverters. You can check the manual on how exactly you can connect them. I'm planning to switch to 3 phases as well as I have 3 phases coming to my house. Before you do that please make sure to balance each phase in your house. Because with 3 inverters you will have 5KW on each phase. (Total 15KW on the 3 phases)
@angelkm2599
@angelkm2599 3 месяца назад
@@golden4o Thank you for your feedback but I want to stay in parallel mono and inject each phase in an inverter thank you
@golden4o
@golden4o 3 месяца назад
@@angelkm2599 If you want to stay on single phase with the inverters and inject, you can only do that with one of the 3 phases that are coming to your house. Just grab one of the phases and connect it to the input of each inverter.
@angelkm2599
@angelkm2599 3 месяца назад
​@@golden4o there is a risk of connecting the 3 phases if why, because each inverter normally sends its current, so I do not understand the risk and thank you again for your return
@golden4o
@golden4o 3 месяца назад
@@angelkm2599 The inverters cannot convert 3 phases into a single phase. No inverter can do that (as far as I know). So in order to use 3 phases, your inverters must be in 3 phase mode. If they are in single phase mode, you can only input single phase.
@freshia2008
@freshia2008 5 месяцев назад
Sir what is the Max. PV input current of this inverter ?
@golden4o
@golden4o 5 месяцев назад
18 Amps