This site is for those of you who are passionate and intrigued by electricity. If you read books, Google videos, read magazines, talk to engineers, join forums, and sit at home and tinker on your time off. This site is for you. If you want to know how this stuff works, why it acts the way it does, and how to experiment with it on your own time to learn a more profound understanding of it. This site is for you.
Electrical Boxes You Never Knew You Needed!
20:26
4 месяца назад
Where Do We Need Exit Signs & Emergency Lights?
10:26
5 месяцев назад
Different Types of Disconnecting Means
21:14
10 месяцев назад
How Does An Uninterruptible Power Supply Work?
10:58
10 месяцев назад
What is a Short? What Causes Them?
16:40
10 месяцев назад
Electricity Takes the Path of Least Resistance
13:50
11 месяцев назад
Can 120 Volts Kill You?
17:12
11 месяцев назад
How to Bend a 4 Point Saddle in Conduit
14:53
11 месяцев назад
Комментарии
@dekingcharles5222
@dekingcharles5222 17 часов назад
Goog one
@jaclynwolf-realtor8107
@jaclynwolf-realtor8107 18 часов назад
Dewalt drill tip, Milwaukee impact driver. your life is out of control.
@jaclynwolf-realtor8107
@jaclynwolf-realtor8107 18 часов назад
How much do you charge for the spd
@benslimen7001
@benslimen7001 19 часов назад
Doesn't the coiling add an effect that sways the measured value? Like wouldn't you get different results if the cable was straightened out ? Or is there not enough coiling effect there?
@shimes424
@shimes424 19 часов назад
I've never bought THHN without foot-markings every 2 feet. Just read the lettering it tells you right on the wire
@user-iq3rs1ut6n
@user-iq3rs1ut6n 20 часов назад
Hey a faster way is to look at the number on the wire. ... I didn't need a tester, and guide book , or the old guy at the company to tell me about it..
@theoblablankenstein8038
@theoblablankenstein8038 21 час назад
Wasbenzine, aceton, terpentine?
@UrbanGardeningWithD.A.Hanks14
@UrbanGardeningWithD.A.Hanks14 21 час назад
Good info, thanks! This house was built in 1953. Any guess as to what AWG it is, 14 maybe?
@artszabo1015
@artszabo1015 23 часа назад
Where did you get ALUMINUM conduit????? Art from Ohio
@NathenaLopez
@NathenaLopez День назад
Thank you 👏👏
@johannsen4171
@johannsen4171 День назад
I built a new garage, I put a pad with a ground rod in one corner, wished I put it in the other corner, (installing a mini split a/c heat) is there a way to move the rod that's in concrete to the other side? Jumper or ground strap is that code? Thanks, love the channel keep the vid's coming! p.s. 200-amp panel from electric company junction box going in.
@johannsen4171
@johannsen4171 День назад
Best electrical channel ever Thanks Proud Dad !
@lordjazen
@lordjazen День назад
I remember I had about 30 offsets in a pile with doglegs(pipe going off to the side instead of straight) My boss came in right before I added another to the pile asked what I was doing and showed me how to fix a dog leg. He left and never saw my pile so after that he just thought I was getting really fast. I did however bend 2 1/4 inch offsets in 1” emt thinking that big pipe meant big voltage. (It was for Ethernet. I was green crackerjack tools no experience boss needed an electrician and tossed me in the deep end showed me how to bend a 90 and an offset and to read the prints. Expected me to quit I didn’t and learned my craft.
@Toonbarmyarmy83
@Toonbarmyarmy83 День назад
Cheers I tried this on my wife's face while she was asleep and the scribble got bigger and bigger and now she's black
@Jason-gk8jl
@Jason-gk8jl День назад
This reminds me of fire alarm guys trying to bend emt. 😆 I didn't know resi electricians ran conduit. 🤔🤣
@sentfromdaniel
@sentfromdaniel День назад
I got the Makita one. It’s small as heck and cheaper than millwaukee
@ryantracey8574
@ryantracey8574 День назад
All these new breakers are overpriced and fail after a few trips, its pathetic price gouging, just another code that's unnecessary and costs homeowners a lot more
@stirlingholloway8112
@stirlingholloway8112 День назад
Thanks - lots of really great info. One suggestion - deliver the info in several passes, making the first pass really short with just the basic central ideas, and then proceed to a couple more levels of telling the story with increasing detail - increasing the amount of special cases and circumstances that could arise. I'm thinking of how newspaper stories are written in "pyramid style."
@juanperla1199
@juanperla1199 День назад
Over all, I guess the main focus here should be always safety first.
@juanperla1199
@juanperla1199 День назад
How about square D and Cutler Humer brakers, they don't make that brand anymore?
@johnrushing4957
@johnrushing4957 День назад
I can't say much about using it on single stand aluminum wiring since we never used that in our plant. We use multi starnd copper wire up to 750mcm and most of our lugs are aluminum. Anytime you mix to metals like aluminum and copper it will oxidize like crazy if you don't use something like Noalox. I have seen copper wires with huge balls of green oxidation on them when some of the hard headed ones here didn't add noalox. A lot of our conductors are handling 200 to 800 amps so a little different from residential wiring.
@leowcr
@leowcr День назад
What happens when you get a short in one of those 14-gauge light circuits on the 20 Amp breaker? Possibility of 14-gauge wiring melting / fire before the breaker reacts?
@jmrandom194
@jmrandom194 День назад
Umm if one hand touches the live wire, on an open circuit, unless you are floating you don't need to have current jump out of your other hand. By standing, you are already grounded. So yes, touching the live wire on an open circuit will indeed shock, and.possibly kill you.
@BullittAutomotive
@BullittAutomotive День назад
Im still going to say nip-ex. This is the same as porsche/porshuh. Bet you pronounce it as karatee
@JamesHollinger-lt8qx
@JamesHollinger-lt8qx День назад
Experience
@GeneralNickles
@GeneralNickles День назад
I stayed at a beach house in Florida that my dad's boss owned once, and it had a fuse panel. This was around 2005 or so. 2 of the fuses were blown and we had to search the whole house and about half of Panama City to find replacements. Glad these things are gone.
@thetrumpeter2054
@thetrumpeter2054 День назад
lazy people, why does it have to be lazy people?
@TheJensss
@TheJensss День назад
Why not use plastic as the rest of the world?
@KevinPerezTheElectrician
@KevinPerezTheElectrician День назад
Lmfo 😂
@KevinPerezTheElectrician
@KevinPerezTheElectrician День назад
You’ve been doing your videos as long as I’ve been an electrician. Im learning a lot from you, man appreciate every video you make.
@KevinPerezTheElectrician
@KevinPerezTheElectrician День назад
Man I need a set like that!!!
@KevinPerezTheElectrician
@KevinPerezTheElectrician День назад
I do as well. I always have guys looking at me saying “you know you don’t have to do that with stranded” and I’d’ just stare at them.
@KevinPerezTheElectrician
@KevinPerezTheElectrician День назад
👂 I like that a lot lol I’m a use that
@landmine5610
@landmine5610 День назад
Did a panel swap for one of those the other day. Had never even seen one irl before.
@ajubation
@ajubation День назад
Any one please provide voltage drop calculation for mm³
@Falcrist
@Falcrist 2 дня назад
Forgot to zero the meter out. Youll be off by about 0.3 ohms
@Mr_RD-1876
@Mr_RD-1876 2 дня назад
The theory of electrons flowing is false! Wires are actually micro tubes filled with smoke. The smoke flows and things work. This explains why things stop working when the smoke escapes 😂
@michaeltristan86
@michaeltristan86 2 дня назад
That's a nice installation and equipment.
@JakeJAZ
@JakeJAZ 2 дня назад
You could also hit it with the Lysol
@MyUnquenchableThirst
@MyUnquenchableThirst 2 дня назад
Same with dry erase
@heretoserve5023
@heretoserve5023 2 дня назад
really?😮
@adilla7423
@adilla7423 2 дня назад
people who get shocked and have tingle sensation from your nerves, by ALA ( Alpha LIpioc Acid) there two types of ALA make sure its the one i said and Its R-ALA. and buy Benfotiamine , take 600 mg of Benfotiamine and 1800 mg of R-ALA . these are antioxiandants especially for your nerves and nerve repair , depending on your case of severity will affect the amount of time to heal. take on empty stomachs. Soon as you take it you defiantly feel better and no side effects.
@Ni5ei
@Ni5ei 2 дня назад
Very informative video! A question though: assuming you had all 3 types of lamps in the same wattage, what's the difference between the ballasts? You couldn't use a 250W mercury vapor lamp on a 250W metal halide ballast? Or is the voltage different?
@bryanst.martin7134
@bryanst.martin7134 2 дня назад
And I just used spit and thumb... What's wrong with me? ;-)
@saullopez3780
@saullopez3780 2 дня назад
i’m so glad these videos are still up on here
@christenecela6424
@christenecela6424 2 дня назад
You should make a video of how journeyman’s don’t like to teach. Those are the worst. Anything you do is bad. If your apprentice is bad then your journeyman is bad
@arthurcruz1662
@arthurcruz1662 2 дня назад
Damn
@JamesHollinger-lt8qx
@JamesHollinger-lt8qx 2 дня назад
Seen the pennies
@BenGates101
@BenGates101 2 дня назад
Question! What type of recessed light can I add to a ceiling that has blown insulation in it?
@mjrussell89
@mjrussell89 2 дня назад
There are 3-way switch loops in like all the units I maintain and it's a real pisser