Blueprints Deciphered: How to Read Commercial Plans (For Electricians) 

Electrician U
Подписаться 750 тыс.
Просмотров 67 тыс.
50% 1

If it weren’t for drawings, most of us in the construction industry wouldn’t have as much of a grasp on exactly what we were to build. The bulk of the building trades would be running amok haphazardly building things across the jobsite with no rhyme or reason! In today’s episode of Electrician U, Dustin walks us through how to read a set of Commercial Blueprints.
🤘⚡️EU Learning System⚡️🤘
For Individuals --- electricianu.c...
For Businesses --- electricianu.c...
-Video courses on every side of the electrical trade (theory, code, safety, wiring, install, troubleshooting, leadership, and more)
-Practice exams for 2017, 2020, 2023 code
-RU-vid videos categorized and searchable
-Audio lessons
-Forum
-Business version has admin portal and ability to assign learning to technicians and monitor progress
-Any business size from 2 techs to 2,000!
🎓💡CONTINUING EDUCATION💡🎓
Sign up here --- electricianu.c...
-State Approved
-Video Based
✍📝PRACTICE EXAMS📝✍
Get them here --- www.electricia...
-2017, 2020, and 2023 NEC versions
-Online Residential Wireman Exam
-Online Journeyman Exam
-Online Master Exam
-300 Question Online Code Cannon (not license specific, all code)
-Take as many times as you want
-All of the above come with printable PDFs
🎤🎧PODCAST🎧🎤
Spotify:
open.spotify.c...
Apple Podcast:
podcasts.apple...
📱👍SOCIALS👍📱
TikTok - / electricianu
Instagram - / electrician_u
Facebook - / theelectricianu
Reddit - / electricianu
Rumble - rumble.com/c/E...
Discord - / discord
🎧🎹Music, Editing, and Videography by Drake Descant and Rob LeBlanc🎹🎧
#electrician #electrical #electricity
The biggest difference between a Residential set of drawings and a Commercial set of drawings is the engineering. Residential plans are drawn primarily from an architectural standpoint as there is much less going on. A commercial set of drawings is much larger and more complex and requires engineering (on top of the architectural) to design ALL the systems to work together to perform what the end customer needs. The architectural set of drawings for commercial looks much the same as in a residential set, just a larger scope. You will have overall views, elevations, and details but will also have things like roof plans and reflected ceiling plans. The RCP’s will show LAYOUT of light fixtures, but not the circuitry, and are a good resource to check vs. the electrical set to make sure everything is cohesive. There will also generally be structural drawings (which show the buildings structure) and maybe even a civil set (which covers the major utilities underground and the site itself).
The Mechanical and Plumbing sets show the buildings systems for these two trades. Always check the mechanical and plumbing schedules vs. what is shown on the electrical sheets to make sure you are roughing in the appropriate conduit and wire as well as from the proper voltage panels. The drawings don’t always line up and it’s good to identify issues early on. Also worth note for these two sets are the larger ducts/pipes. It will show general locations for these so you can see where NOT to install something electrical that conflicts with the location.
The electrical set is much larger and has more detail for a commercial set of drawings. The front electrical sheet usually contains notes and symbols. This will help us navigate what is shown on the rest of the sheets. There will be a lighting page showing all the different fixtures as well as the switches, dimmers, and sensors that control them. It may be helpful to mark up the sheet with colors to help you identify circuitry/fixture/switch types easier. The power sheet will show the locations of all the power type devices along with the panels they are being fed from. Many power drawings will also show you how many wires and what size to run for each circuit. Again, these are drawn by an engineer and are usually very thorough. You may even see a kitchen drawing that will show the electrical rough in for the kitchen equipment if there is one on your project.
Also within the electrical set of drawings there will be a one-line diagram. This diagrammatically shows the panels, transformers (if there are any), and large switchgear. This drawing will show us what panels are being fed from what along with conduit and wire sizes. A grounding plan is usually available as well to guide us through what size grounding conductors to put where. Most commercial buildings have more than one panel in them, and a panel schedule sheet will also be available to us.

Опубликовано:

 

29 сен 2024

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 101   
@illumiNelz
@illumiNelz Год назад
3rd year apprentice for an electric company. Most don't really take the time to let you even LOOK at the prints, this video does so much help for someone like myself. Thank you!
@oculophilia918
@oculophilia918 Год назад
Leave that company immediately. They care more about their position than proper training the future.
@slickwilly6868
@slickwilly6868 10 месяцев назад
Go to your boss and ask for a set of old blueprints from a job that's been completed.
@iamelectrictn3147
@iamelectrictn3147 10 месяцев назад
Honestly a 3rd year apprentice has no business looking at the prints other than maybe to see where lights are going. The foreman or lead should be handling those. You will get there however
@zhumusic-ng9tr
@zhumusic-ng9tr 9 месяцев назад
Bro I can't even get in A company. I went to school too lol
@iamelectrictn3147
@iamelectrictn3147 9 месяцев назад
@@zhumusic-ng9tr find a legit company that does commercial/industrial. There is ZERO shortages of work only qualified people
@hydrochris
@hydrochris Год назад
Industrial plans next? That would be great to see the differences
@kevinsadowy5602
@kevinsadowy5602 Год назад
Industrial is just commercial with more cowboys 😂
@jakerasp
@jakerasp Год назад
Maybe he can just do a how to read video??
@Daisyvaladez8106
@Daisyvaladez8106 Год назад
You’ll deal with a lot of contactors and relays and motors that’s the difference
@ThreePhase470
@ThreePhase470 Год назад
​@andr3w_496yes
@joshs1555
@joshs1555 Год назад
The plans for commercial and industrial are the same. The difference is what the building is going to have in it. I do Fire Sprinklers, I'm a pipe fitter. I have done many industrial buildings that do not have any horns and strobes on the fire alarm system and their system is there just to monitor mine. It's because only the people that work in that building will ever be in that building. The Sprinkler system is there to allow time for them to egress and they know their planed escape route. Where as commercial buildings are going to have employees and customers in them essentially at all times so they will have more signage and horns and strobes. But as far as the plans go they look the same well save for like if it's a office with grid ceiling then you will see the ceiling on a reflected ceiling plan print, where as if it's a open warehouse you will see little lines for the bar joist and columns.
@nwil2003
@nwil2003 Год назад
Kill the distracting background music.
@edwinhn22
@edwinhn22 2 месяца назад
It’s really hard to concentrate with that music
@PsalmCourier
@PsalmCourier 2 месяца назад
I could understand if its obnoxious or loud but i didnt mine it at all..
@PsalmCourier
@PsalmCourier 2 месяца назад
*mind
@ElectricRob
@ElectricRob Год назад
Great overview of a set of commercial plans! - as a commercial electrical engineer who has been on the other side of these prints for decades, I appreciate seeing this overview from your position as the installing electrician. Kudo's for reviewing ALL of the prints, including Architectural, Mechanical and Plumbing - a great point to make for new electricians (and on larger projects you will even have Civil and Landscaping and even Structural plans to review). Buildings are a lot of interconnected/intertwined systems from many trades, so it's great that you emphasize getting that overall feel for the whole building. I would also add that these types of projects are many times designed to what is called a "basis of design" - a term meaning that much of the equipment is just selected as a "placeholder" for the final equipment, which could be from a number of different manufacturers, so the plans end up being a bit generic. And you nicely showed how you take this "diagrammatic" set of plans and carefully add your installation details such as the j-boxes, actual routing, etc. to allow you to build it, and present an accurate set of as-built or "record" drawings for the building owner. Finally, I do appreciate your comment about engineers making mistakes - I'm the first to admit that I have never produced a "perfect" set of prints, and have always felt that building buildings takes close teamwork between designers and installers. Well done sir!
@kweidhaas57
@kweidhaas57 Год назад
The background music is distracting from your excellent content.
@brandonkeefe7106
@brandonkeefe7106 7 месяцев назад
Noob here. Your videos have helped me so much when it comes to knowing how and why and when it comes to tools what to use when and where. I work with a buddy of mine who has been an electrician for 4 years and I’m a noob but he said he is surprised I know as much as I do because he has had some guys who are just ignorant when it comes to the process but I credit you for a lot of the things I’ve learned
@michaelhinchey
@michaelhinchey Год назад
How do you handle prints with junction boxes when someone else is running a certain area? Seems like everyone just wants to throw a junction box where ever they want.
@BBarbeito14
@BBarbeito14 Год назад
If you put a junction box somewhere it should be added and drawn into the prints with pencil or highlighter
@tonydyer5073
@tonydyer5073 Год назад
Great job explaining commercial blueprints, D. I admire your passion and dedication to electrical education.
@NoAlvarez
@NoAlvarez Год назад
interesting take. I was curious about the low voltage systems. In my state, the electrician provides pathways for the low voltage systems (data, cameras, fire alarm, etc). The low voltage tech installs the wires and devices. Did your plans not include any of these systems or you are not responsible for them?
@ethanrushing2190
@ethanrushing2190 Год назад
I thought he said he was from Austin and in Houston where I work normally the low voltage would be a separate contract from the electrical contract but, we still usually install part of the contract like raceways and pull strings
@BenGates101
@BenGates101 Год назад
Question. I have a light in a pantry . The size of a closet. The light is a bulb in a switched socket. I’m told that is against code. Can I replace it with a recessed led light?
@zacharybob4336
@zacharybob4336 Год назад
What you can do is hire an electrician instead of trying to get things for free from people who invested years of their life to acquire the knowledge to safely do electrical.
@Enlightn76
@Enlightn76 Год назад
Great summary for such a short video, plan reading could be an entire series. You do a great job putting a lot into a small package. •When "speaking with engineers" get it in writing or I guarantee you any verbal directive that ends up not working out will be conveniently "forgotten." at the end of the job your stuck holding the bag. •Consult with shop drawings from equipment manufacturers if they call for circuitry or other extras beyond original scope of work you're due a change order. The contract was signed on the engineered plans not company X's shop drawings. •Once you have more than 10 guys under your supervision it's unlikley you'll have any tools in you hands other than a tape measure pencil and phone. Keeping the crew going with materials,info, and guidance is full time job.
@frstgear
@frstgear Год назад
great video, I love the overhead view. What I think might be more beneficial is if you took the dwg files showed them on a computer versus an overhead shot.
@--JohnDoe
@--JohnDoe Год назад
You installed 3 phase delta high leg system? 240v?
@zhumusic-ng9tr
@zhumusic-ng9tr Месяц назад
😮
@BrianFo
@BrianFo Год назад
Ever do any stage theatres? I feel like I'm always helping the electricians learn the unique stuff of Theatrical lighting systems.
@chrisf7119
@chrisf7119 Год назад
Thank you 2 years in commercial and still working on blue print familiarty. some foreman try to help out and want us to use blue prints but the two foreman ive worked with the most hate it when guys look at the blueprints they want it done how they say which I get. and also with rfi's and updated plans they keep on their ipads and you never see those. But trying to get more familiar and be able to read and interpret plans thanks for the help!
@paulhalverson4398
@paulhalverson4398 Год назад
Image looks considerably improved- new camera? Set looks great too. As usual, great teaching video. Thanks so much!
@jacques-michaeloosthuizen1235
Thank you for the video. I am a graduate electrical engineer and have designed a few of these comercial plans in the 13 months I have been doing this. I have made some mistakes but always try to correct them asap and it does help when the contractors just ask the question if they are not sure about something on the plans. Some times the mistakes just come from the drafters not understanding the engineers markups and they just slip through the cracks unnoticed. It was ingeresting to see the difference in the style the plans are presented in the US vs here in Australia as the symbols used are very different from what I am use to.
@martf1061
@martf1061 Год назад
Is it true that engineers never assume their mistakes, when the electrical worker points them out??
@jolyonwelsh9834
@jolyonwelsh9834 Месяц назад
Half the time the architects don't give you enough information or they give you inaccurate information. They usually leave it up to the contractor to figure out what goes where.
@albduke
@albduke Год назад
How go about running coduits?
@besttopplayer5235
@besttopplayer5235 16 дней назад
2.5 years apprentice now this videos help me alot thank you
@briansiebert8242
@briansiebert8242 Год назад
Would you recommend, as an apprentice, obtaining a set of plans to review/study while at home?
@Bluecollarrealtor
@Bluecollarrealtor Год назад
Yes
@abdulqadir150
@abdulqadir150 2 месяца назад
Good
@Richard_Murphy_Mortgage_Guy
@Richard_Murphy_Mortgage_Guy 3 месяца назад
Great video! Where can I get that super cool whiteboard??
@elvizhernandez4305
@elvizhernandez4305 5 месяцев назад
So are the conduit runs not pre planned? Meaning these need to be drawn in by the electricians as the job goes on?
@billymendoza7053
@billymendoza7053 Год назад
My brother my prayers have been answered thank you
@jake-rz2fk
@jake-rz2fk 6 месяцев назад
im like 6/7 months in and this made no sense
@jwhoosh7451
@jwhoosh7451 Месяц назад
you just have to get more hands on in the field. Won’t really make a lot of sense just based off a youtube video.
@FENTANYLJET
@FENTANYLJET 3 месяца назад
Shouldn’t the 3 phase panels take 4 4/0 not 3..
@صيادكفرالشيخ_مسير
السلام عليكم أنا اختكم صاحبه قناه طبخ ومفيش عندى تفاعل ومشاهده ممكن تنصحوني ب حل المشكلة ازى وشكرا لحضرتك
@EchoTangoSuitcase
@EchoTangoSuitcase Год назад
I wish 3 things: 1. That all prints had comprehensive legends. 2. That people would remember it's a 2D representation of a 3D space. 3. That it be illegal for anyone to use BIM without at least a year bending conduit, installing water/sewer/gas/HVAC, and reading paper prints. Punishable by 30 days of watching The View on a continual 24-hr loop.
@iamelectrictn3147
@iamelectrictn3147 10 месяцев назад
I think what your doing is great to attract people into the trade. Let me however help you out with a couple things. For L1-51, L1-53, L1-55 The prints are showing you those three receptacles to pull together. 3 hots, three neutrals, and one ground. They are all 120v single phase, not three phase. You could normally get away with a old school full boat (3 hots and one neutral, using breaker ties of course), except obviously its speced out here for separate neutrals. It looks like someone changed that up by the scribbling out of the original ciruit for whatever reason so that may not still apply. That part is irrelevant. Shit changes as thats fine as long as the panel schedule reflects this. The 42" on the print for that receptacle is 42" AFF (above finsihed floor) for that kitchen receptacle. On the riser disagram 4 and 5 are disconnects, not panels. Obviously from the CT cabinet they leave and then hit disconnects before feeding the low voltage panels. The other "prints" your referring to on the details of the equip to be installed those are called submittals. They are your friend and very nice especially now with the modern technology. Good prints go a long way
@spadeninja9
@spadeninja9 10 месяцев назад
so you had 3 phase voltage coming in, as that 208v? how did the engineers get 240v panels without a transformer?
@Info.isfree.openmind
@Info.isfree.openmind 5 месяцев назад
The reflected ceiling plan also show with shades of black/white or dots if the ceiling is hard lid or drop tile or concrete. This is important for rough-in of back boxes and mounting of devices, the RCP will help giving and idea to know what type of hardware is needed for mounting devices, lighting,fans, etc.
@Shawn_G_
@Shawn_G_ 5 месяцев назад
As a beginner is this the right video to start with?
@ericfransen1309
@ericfransen1309 Год назад
Heads up for anyone installing/bidding AV infrastructure for a Performing Arts Theater, Concert Space, or an AV intense Multipurpose gym etc, the conduit required always takes those who haven't done one by surprise. There is a boat load of it and AV signal separation issues as well. Look for pathways especially in building shells or existing buildings. In these venues there is often an AV technical transformer and Isolated Grounding system. For coordination, we just went through a Navisworks exercise to coordinate with all trade in 3d for pathways etc. Seems to be going well.
@HunterRichey-w4w
@HunterRichey-w4w 11 месяцев назад
Keep it up bro I've learned so much from you! Getting my License down here in South Tampa Florida!
@brianmcdermott1718
@brianmcdermott1718 Год назад
Great info. well explained, Thank you Dustin. 👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍👍
@rylegaming2903
@rylegaming2903 8 месяцев назад
As a 3rd year Electrical Engineering Student, I always wanted to learn how I can do what electrician do like practical not just by solving theory. I love solving thats why I enter i electrical engineering course but I thought it is more good if I have a knowledge about what electrician do so that we have a good understanding about what will to do.
@paulanthony6763
@paulanthony6763 9 месяцев назад
Red, Black, Blue is insane! What about your BOY 277v?
@curtw8827
@curtw8827 Год назад
I was the design engineer of record on a manufacturing plant before I retired. Electrical plans had 250 sheets. Good presentation.
@camdendexter
@camdendexter Год назад
I know some businesses are moving to planning stuff in things like Autodesk Revit in 3D to make visualizing easier. Have you see any of this in your trade yet?
@albduke
@albduke 7 месяцев назад
How do you figure the actual layout of Panels,conduits, wire inside the conduits to the different loads?
@joshstuckey9977
@joshstuckey9977 5 месяцев назад
Do a oilfield prints please
@supercadet111
@supercadet111 Год назад
Love that Junction box layout. Always thought something like that would make sense.
@jaredmoglia711
@jaredmoglia711 Год назад
Can you do a lengthy like 3 hour version of this and go into detail along with attaching a pdf so we can actually see it closer up ourselves
@Neil-ym8vy
@Neil-ym8vy Год назад
The JM Electricians shouldn't be looking at the plan alot. That is the supervisor or leads job. Usually they have people team up in the morning and give the Journeyman a smaller copy of the plan if he really needs to look at them.
@anthonymartinez8347
@anthonymartinez8347 Год назад
I just barely past my jm exam last month, they just gave me the blueprints to a dominos witch starts next week,, not sure how to approach this
@aaronboggs7152
@aaronboggs7152 11 месяцев назад
how did it go?@@anthonymartinez8347
@ryelleija7580
@ryelleija7580 20 часов назад
@@anthonymartinez8347 hey 1 year later I know but I’m switching from residential to commercial and I wanted to know if you understood the blueprints then vs now. Also how was your experience in commercial .
@fusion772
@fusion772 Год назад
When do you find the time on site to read the plans in detail? It would take hours to go over the whole electrical section let alone the mechanical etc
@krytera3154
@krytera3154 Год назад
We just looked over some Commercial plans today in my electrical course too so now I get to watch this too
@mariotorres5133
@mariotorres5133 19 дней назад
Videos too long
@joseavila2076
@joseavila2076 10 месяцев назад
What state are you located at? I need to work for someone like you
@vince6829
@vince6829 3 месяца назад
Thank you for sharing your knowledge.
@rubenrios9649
@rubenrios9649 Год назад
Really loving your vids bro thanks
@RaviSingh-yo3jt
@RaviSingh-yo3jt Год назад
Would like to see industrial machines plans next
@travissmith383
@travissmith383 5 месяцев назад
Get to the point
@aerodynamic2685
@aerodynamic2685 Год назад
Need an in-depth course for us premium members
@loganocchionero6621
@loganocchionero6621 10 месяцев назад
Wow. This was really helpful
@josefschubert9401
@josefschubert9401 11 месяцев назад
The content is great but The music sounds like you are in a funeral home.
@PsalmCourier
@PsalmCourier 2 месяца назад
Dang guys is it that bad? Lol. Funeral home? Reminds me of the show how its made.
@wheatstonebridge
@wheatstonebridge Год назад
Im a woman looking to get into the trades. Im excited as I want to work as an electrician. I love the highlighting idea, I cannot wait to use my highlighters.
@DrEw-cx9pt
@DrEw-cx9pt Год назад
A ground for each phase on 3 phase power?
@Enlightn76
@Enlightn76 Год назад
Not required. Grounding conductor can be shared with multiple phase conductors so long as ground size is suitable for largest current carrying conductor in raceway.
@DrEw-cx9pt
@DrEw-cx9pt Год назад
@Sicilian switchblade that's how I have always done it, but Dustin mentioned a marking for 3 phase with 3 grounds, and that would be a new one for me.
@curtw8827
@curtw8827 Год назад
I think that was three phase conductors, three neutrals, one ground in that homerun. Probably 3 120v circuits going back to GFCI Cb's since it was a kitchen.
@Penguin545
@Penguin545 Год назад
I can’t tell you how many journeymen we have had on our job site from temp staffing that can’t even read a panel schedule- they pulled in neutrals on every 208 circuit and wasted 500’ of white per PDU (transformer/panel all in 1 unit)- we have 7 pdus in a row over a 1,500 long floor and they did it on almost every one- wasted thousands of dollars of wire on that single mistake. They also kept referring to 208 as 240 😒.
@Enlightn76
@Enlightn76 Год назад
I'll go ahead and say it. Those aren't journeymen...
@zacharybob4336
@zacharybob4336 Год назад
Journeyman thru temp staffing? TF kind of contractor are you working for?
@Penguin545
@Penguin545 Год назад
@@Enlightn76 unbelievably they passed the state exam but certainly not in spirit no
@Penguin545
@Penguin545 Год назад
@@zacharybob4336 currently building a DC for a major retailer out of state, the job has been staffed at times with 3-5x more guys from temp staffing than employees of the actual company that is running the job. It’s a a case of we need warm bodies that can run miles of pipe (albeit not very well). It’s a 4 million square foot 3 story DC- we have been working on it for 12 months nonstop with 8-27 guys. At least 100% + turnover rate, with plenty of that turnover being people invited to leave.
@zacharybob4336
@zacharybob4336 Год назад
@@Penguin545 sounds like a shitty company to take on a 4 million square foot distribution center and not have 8-27 electricians to man it.
@TheTrumpmancometh2024
@TheTrumpmancometh2024 Год назад
Most contractors keep their prints on an Ipad so if you dont know how to use an IPad you’re stuck like chuck!
Далее
Understanding Blueprints: Electrical Symbols Explained
19:22
Qalpoq - Amakivachcha (hajviy ko'rsatuv)
41:44
Просмотров 400 тыс.
How To: Reading Construction Blueprints & Plans | #1
21:41
Learn Blueprint Reading - Symbols - Part 1
4:32
Просмотров 2 тыс.
Day in the life of commercial electrician
19:50
Просмотров 144 тыс.
How to read Electrical Blueprints!
18:13
Просмотров 32 тыс.