ICM Furnace Control Board Review and Install
10:35
4 месяца назад
Комментарии
@lincolnloggedon
@lincolnloggedon 19 часов назад
I am curious if having just a hvac career certificate from a local college will be enough to have a long and lucrative career? Potentially even starting my own business one day. I am 28 and deciding to go back to school for HVAC. The school I am applying to only offers a 12 month certificate program. I will be applying for an apprenticeship while completing the program. As I develop my skills I am open to relocating to other states for better pay. More so interested in commercial than residential. I know this career will be tough and come with many pros and cons however I am excited to transition into a reliable career that will allow me to become financially stable. Any advice is appreciated.
@camolance
@camolance 20 часов назад
I'm a black service tech and I practice to let it be known whenever I'm moving from one area to the next by saying sir or mam I'm going to the van or I'm going upstairs just to let them aware of my movements without having to wondering where I'm at, one of the worst feeling is to catch a customer searching for you .
@jbouchard667
@jbouchard667 22 часа назад
You had 100 psi on your low side and 161 on hi side. Not 31 psi and 56 like you said in video.
@tedlahm5740
@tedlahm5740 2 дня назад
Why did we take the handles off?
@crisb94
@crisb94 2 дня назад
Loved it. Didn’t have someone tell me every week for a tool check. Your own tools make you do the job better. Especially when all yo shit was brand new. Plus Everyman needs his full set of tools for his own side work. One good job leads to the next
@VRCM_Skywarn_XUSA
@VRCM_Skywarn_XUSA 3 дня назад
Just ordered one, can't wait. Thanks for posting.
@bradsautomotiveandmarinellc
@bradsautomotiveandmarinellc 4 дня назад
Let's say I want to use the refrigerant. I use the filter drier inline with where the refrigerant is being discharged, I go through the same steps you just mentioned. Is the tank going to have enough pressure to reuse the refrigerant?
@Jackofallmasterofnone94
@Jackofallmasterofnone94 4 дня назад
TP LD for the win. I started with the tech pac, it’s too big for attics and crawls. I gotta carry two small bags but it’s better for attics and crawls. Liked having everything in one bag but too big.
@omarjuarez3812
@omarjuarez3812 4 дня назад
🫡
@firesprk
@firesprk 4 дня назад
Did I miss it, how did you carry your drill?
@k-laus9435
@k-laus9435 5 дней назад
How long have you been doing HVAC btw.
@k-laus9435
@k-laus9435 5 дней назад
You need to inform people of the merv ratings of these filters. Btw if you have a single filter grill on a return it’s always going to get sucked up like that. Appreciate the video but static should be taken as a total. Impossible to determine high static by pulling on a filter. Too many other factors involved.
@trevmint5615
@trevmint5615 6 дней назад
Feet a 4 inch pleat
@JoeB3
@JoeB3 6 дней назад
I love the 680, had my whole bag with the meter stolen 🤬 just got a new 680 this week. lol just noticed the comments are from 2y ago, shorts without dates, smh.
@HobbyTalk
@HobbyTalk 7 дней назад
Let me speak to the engineer, I just want to speak to them… 😂
@NY-DIYMECH
@NY-DIYMECH 7 дней назад
Well Done!! Cheers.
@YTsux24-7
@YTsux24-7 8 дней назад
I read somewhere where using distilled water and store bought ice bags was recommended over tap water. Stir the ice water vigorously before submerging the probes. Good video sir!
@martinberkovics9194
@martinberkovics9194 8 дней назад
What's the app you use to check your pressure and sub cooling/superheat ? Thanks!
@aschiavello07
@aschiavello07 8 дней назад
Looks so easy. As far as the water spilled, I'm sure you know the temperature up there. It drys fast!
@Matt-d8m
@Matt-d8m 11 дней назад
Install a lower merv filter and change or clean more often
@sheepdog3828
@sheepdog3828 11 дней назад
400 bucks for a retired guy not so much, whew! nice but over my pay grade...
@mackmaaly84
@mackmaaly84 11 дней назад
Good stuff bro 💯
@iig2310
@iig2310 14 дней назад
Very nice tutorial on a PSC Blower Motor Replacement. Thanks for sharing KNOWLEDGE... MUCH RESPECT.
@danielwhite8148
@danielwhite8148 14 дней назад
Same issue, annoying as hell
@kenthomas4668
@kenthomas4668 15 дней назад
I just kept an old wire harness and cut off one end and kept those wires attached to the 1,3,12,and 15 positions. I then added a red and blue wire as required to bundle those pairs of wires. Now we just plug it into motor and connect at r and c terminals.
@edgarguerrero8242
@edgarguerrero8242 15 дней назад
I’ve seen this before after a maintenance guy left capacitor wire loose touching metal too and grounded compressor
@TheCherokeeKidd
@TheCherokeeKidd 16 дней назад
Like your load out, you need to check out the cobra auto adjust pliers
@denuslevine210
@denuslevine210 16 дней назад
Interesting didnt know their woz a strainer in indoor liquid line flare section Youve a good understanding 😀
@frackncylons5737
@frackncylons5737 16 дней назад
Hey man, I wish you could work on my system! Do you have that link you mentioned around 5:55?
@kevinward9565
@kevinward9565 16 дней назад
I just turned 36 today. I start airconditioning Technology august 19th. Im nervous as I can be. Im tired of working crappy jobs that pay little. Im just really nervous that Im gonnna crash and burn.
@illiniwood
@illiniwood 16 дней назад
Without this video and since you were the last to touch this unit, they would have blamed you for this, as they always do. Good thing you shoot video for this channel. It just saved your rear.
@MrSmoothstrings
@MrSmoothstrings 17 дней назад
Thanks that is a good remedy and alternative. As soon as my parts arrive I will have to do the same thing to my badly corroded screws in my bath tub faucets. Thanks!!
@seangriffon6502
@seangriffon6502 17 дней назад
I have a feeling that the compressor had been running hot for sometime due to the darkening of the label on the compressor. I was told by a emerson copeland rep that if the label is discolored, and looks crinkled and coming off compressor then that is a sign of compressor overheating or running hot. Label should be white in color and completely adheared to the compressor housing. This looks like a heat pump, and looks to be in good shape and not too old plus its a lennox. Heat pumps are way more expensive than a straight cool unit so most definitely worth putting in a new compressor. I would check everything over before hand. I feel the run cap had nothing to do with it. If wired wtong compresdor wont start, if you get fan and herm backwards fan will take off like a rocket and overheat and either go off on thermal overload or burn up. If the mfd is too big for compressor it will overheat and trip the thermal. You need to check the mfd rating on the capacitor and verify it with the copeland app or contact lennox directly. My thought is maybe someone tried to savatage this unit by installing a cap that had a much bigger mfd rating than it calls for. I have seen this a few times. Compressor going off on thermal because the last tech installed one of a bigger value.
@rcinfla9017
@rcinfla9017 17 дней назад
With hardstart kit you can have a bad Run cap and compressor will startup and appear to run normally, just run current will be high and power factor will be low. Run cap has little contribution to startup when there is a large start capacitor with hardstart kit. Electrolytic start capacitor and potential relay have poor reliability. Suspect them first. I would also have given it a new start capacitor just because they have limited lifespan with their fluid electrolyte drying out over time. Capacitance drops as electrolyte dries out from capacitor heating over time.
@justincummings4775
@justincummings4775 17 дней назад
Yep I’ve started going straight to the high pressure switch when leak searching this unit
@realSamAndrew
@realSamAndrew 18 дней назад
I believe what happened here is the herm wire was sandwiched between the frame of the condenser and the edge of the capacitor, which is all grounded, which means the start wire had a direct short to ground. Turn on the power and BOOM 💥💥.
@precisionfishingsouthernin8680
@precisionfishingsouthernin8680 18 дней назад
Man I just learned so much about my unit
@eastcoast186
@eastcoast186 18 дней назад
So who eats the compressor the company or home owner????????
@HAWKTUAIT2024
@HAWKTUAIT2024 18 дней назад
Maintenance guy
@DS-fb9te
@DS-fb9te 13 дней назад
@@HAWKTUAIT2024❤I’m glad wasn’t the home owner
@thisisyourcaptainspeaking2259
@thisisyourcaptainspeaking2259 18 дней назад
It's not very clear to me how a tech caused this failure, was an incorrect capacitor installed or not?
@realSamAndrew
@realSamAndrew 18 дней назад
It's not incorrect capacitor, it's incorrect INSTALLATION
@thisisyourcaptainspeaking2259
@thisisyourcaptainspeaking2259 18 дней назад
@@realSamAndrew Oh, so the compressor damage occured as a result of failure to connect capacitor.
@realSamAndrew
@realSamAndrew 18 дней назад
@@thisisyourcaptainspeaking2259 sort of, yes. See my recent comment above for the explanation.
@syncedsatoshi
@syncedsatoshi 19 дней назад
Seen this before on a service call, quite amazing how the harness comes off. I'd like to witness this happen!
@andrewveres8914
@andrewveres8914 17 дней назад
No you don’t it’s very scary and very dangerous to
@mariusm3595
@mariusm3595 19 дней назад
Awesome video !
@NATHANFREDERICK-rs7yb
@NATHANFREDERICK-rs7yb 21 день назад
NO crawl space, SEWAGE IN CRAWL SPACE. NOPE!
@qsm1334
@qsm1334 23 дня назад
Ive heard a lot of their meters go bad if you store them with the leads connected🤔good thing they have good warranty tho
@drah9955
@drah9955 23 дня назад
Yes, a reminder, filter … You had me laughing when you caught the filter & said, idiot !!! Little mistakes we have in common 😂
@bmobley1
@bmobley1 23 дня назад
Whats the model of the fieldpiece bluetooth thermo couples your using?
@peterrivas2064
@peterrivas2064 24 дня назад
Nope...
@AdamCraig-ir6yl
@AdamCraig-ir6yl 24 дня назад
Was that a cooling maint or a break down call?
@GoSuM23
@GoSuM23 24 дня назад
Honestly I dont recomend crappy filters. I would do a static test , adjust the fan speeds, record delta T differences.
@GoSuM23
@GoSuM23 24 дня назад
personnaly air quality is also important. Nobody uses the 24 bolt electronic filter that does use fiber glass, it also filters 90%
@GoSuM23
@GoSuM23 24 дня назад
I had a sattelite dish I backed up into not realizing it had a huge asian hornet nest on it. It was like thw craziest camoflouge nice find.
@Neto-1984
@Neto-1984 24 дня назад
Exposed live wires, and now this?! WTH!