Founded in 1957, Meier Supply is an employee-owned wholesale distribution business with a rich history and family culture. With 17 locations including a state-of-the-art distribution center, our core values (Excellence, Trust, People, and Respect) align strongly with our Mission Statement, “Customer Satisfaction Guaranteed”.
With five distinct divisions, we provide service and support throughout the HVACR community in NY and Pennsylvania. Our divisions include Commercial Refrigeration, HVAC, Technical/Training, Controls, and Applied Products, and we have partnered with the absolute best vendors and manufacturers in the industry.
Poised for continued growth, Meier Supply continues to be proactive in identifying market trends and maintaining our position at the leading edge of HVACR distribution. We provide expert technical knowledge and are relentless in supporting the needs of our customers.
We graciously look forward to earning your business.
Where is mode 25 and 27? to set the fan in standby in heating and cooling. Mine is constantly running at low speed, which is not needed in my setting with the remote thermister being used in the room, not in the air mover.
Thank you! I could not determine how to change which temperature sensor was used for reading room temperature on the TAR-40MAAU controller/thermostat. As recently installed, it was using the unit/air handler sensor, and the the room temperature reading was very inaccurate. Even with the heat setting set as low as it would go to 63 F (Which is another problem, why can't I set the heat any lower than that?), the unit was heating to 74 F or more. Now that the room temp is using the sensor in the controller, the room temperature reading is accurate, and the system is heating to the correct temperature. None of the manuals helped. This was such a simple fix to get it working correctly, I am so glad I stumbled on this video.
hi sr im working on lg vrf 4 with three outdoor unit and three hidro kit and three diht indoor unit.Diht unit i dont used ,but when i use hidrokit from outdoor unit work onli one and i dont see error. have some solution thanks
Thank you so much for this video. My thermostat was pulling room temp from somewhere else and myself and the technician who installed couldn't figure it out (not thrilled about THAT). This video saved the day!
I been researching, the s3 connection has 120v ac but conducts DC voltage like power line communicating. There is two capacitors at the S3 connector where the DC signals is send from one end and stop at the other end and is collected for capacitor read the pulsation signals and passes the AC signal flowing with no interference