Welcome to PLC automation channel . Find out and learn about PLC programming with various videos. Also comment your queries if you are looking a video on a particular application.
Join the instagram channel to send your queries and help topics directly.
Visit the Collection list of various quality products at reasonable price with great reviews. amzn.to/3KHboOl
@@srpskisabor Hello friend, Check out the dataman software help section. Pdf is available there including tags excel sheet. You have to create the same in your program. After successful communication with your dataman. Same tags will be used for further operation. Note Addresses in the hardware and the tags sheet must be same. DM on instagram for further queries.
@@zackk_54544 i done it, it just need a little configuration, but right now i have another problem, my fc 302 drive cannot start, even though i can change the reference speed, no error occured.
I have 1 query here. Why are we creating UDT with 8-15 bits of Cw first then with 0-7 bits of Cw? Is there any reason for it ? I feel some data gets transferred in byte format ?
Siemens blocks has predefined bit structure for control/ status words. We have to follow stuructre to read /write the data if we using those blocks. For more queries connect on Instagram.
That's true. Definitely we have to assign the device in the hardware. We did the trial with only one drive and its working cause only one device is in the network so it has automatically assigned. It doesn't work when there are multiple devices in the network. We have to assign each them.
I'm new to the world of plc and I have a few questions in reference to the video which by the way is very good. why do we use the DPRD_DAT and DPWD_DAT blocks instead of the SINASPEED block, what is the difference? and are all these variables in the plc data types all really necessary to put? THANK YOUU🤍
Hello Friend, I have not used that SINASPEED block, but as per the block description mentioned in help section I guess we can use it instead of using DPRD_DAT & DPWR_DAT blocks. Main difference is only standard Telegram 1 can be used with SINASPEED. Also, No need to mention all variables in data types but make sure you use the right bit to turn on as per the bit addresses. You can check the help section of the SINASPEED block. Variables are necessary to be defined in the data types If you use DPRD_DAT, DPWRDAT.
If your application does not required much functions go for the SINASPEED and share your feedback. For more queries you can join the Instagram handle. Thank you
Profinet Gsd file is not available on Danfoss website. Either you should contact danfoss so they will provide you or provide mail id so that someone can share the file.
Hello Friend, No video has been uploaded on profibus till now. Will make it and upload soon. Meanwhile join the Instagram channel and send your application query on the DM. Thankyou
277 defined for telegram, 278 defined for parameter access point but to execute read and write operation words defined only at 279. Hope you got your answer.
It happens soemtimes. Check you cable connection. Check your laptops IP address series. Make sure IP address range should be as 192.168.6.0 series. Recycle the cognex power.