Тёмный
MEP TECHNICAL WORLD
MEP TECHNICAL WORLD
MEP TECHNICAL WORLD
Подписаться
Hello Welcome to My Channel ,
In this channel you can learn all about Following:
Electrical Engineering
Plumbing & Sanitary Engineering
HVAC Engineering
AutoCAD Drafting
And many more engineering topics with Practical in English
Please Like , Share , Comments and Subscribe to get more videos
DO fuse Sizing and selection | Drop out fuse
10:07
7 месяцев назад
Electrical Modular Box | Modular Box  Sizes
8:15
8 месяцев назад
RCCB Working and Wiring | What is RCCB ?
9:10
10 месяцев назад
SPD Working and Wiring | Surge Protection Device
9:43
11 месяцев назад
Комментарии
@khansokha4097
@khansokha4097 День назад
excuse me Sir =10*33.3/100 = 33.3 why T.C.L = 366.3 kw
@israeltmachona510
@israeltmachona510 3 дня назад
What size of a contactor would you recommend for a borehole pump domestic users
@subramaniananbazhagan6103
@subramaniananbazhagan6103 3 дня назад
Sorry bro you are not right, Req cap bank is not only based on Connected load. must consider type of load is a capacitive load or inductive or resistance, so based on load the actual power factor will arive and based on actual PF and connected load we can select the bank value, thank you
@danielteyehuago1633
@danielteyehuago1633 3 дня назад
Please do you have a video on how to calculate cable size for three phase induction motor. 5:57
@danielteyehuago1633
@danielteyehuago1633 3 дня назад
I'm here again. Thanks for sharing this with us...
@rodneytedford
@rodneytedford 4 дня назад
Very bad English,can barely understand
@MuhammadQasim-sc5gn
@MuhammadQasim-sc5gn 5 дней назад
Ur info is not confirmed in this vd because u r concept not clear
@UvinduSenuj
@UvinduSenuj 6 дней назад
Thanks for ur guide lines
@pavandevara2503
@pavandevara2503 10 дней назад
Superb Explanation tnq sir..
@adnansafi2332
@adnansafi2332 12 дней назад
Final Total connected load is 366.3 kw then after converting maximum demand load in KVA we are getting same value as final total connected load 366.3 KVA thnen wht is the use for maximum demand load based on maximum demand factor we can directly take total connected load and then calculate tarnsformer capacity kindly let me know
@Maaran1234
@Maaran1234 18 дней назад
How to calculate derating factor for power cables underwater also how to calculate for DC supply
@salifukala2
@salifukala2 18 дней назад
very very educative
@danielteyehuago1633
@danielteyehuago1633 19 дней назад
Please can you refer me to your video on home to select cable size for a motor...
@briannnnnnnnnnnnnnnnnnnnnnnnn
@briannnnnnnnnnnnnnnnnnnnnnnnn 20 дней назад
Shouldn't the mcb breaking capacity be larger than the cable short circuit calculation?? So that it ca successfully interrupt the short circuit,,,
@rajeshwarisandilyan6215
@rajeshwarisandilyan6215 29 дней назад
It was well explained sir , thank you . I finally found the video clearly explaining the latching wiring
@msaadahashim6591
@msaadahashim6591 Месяц назад
Good info but explaination and video not good. Let make it shot and straight forward.
@neilcowen2831
@neilcowen2831 Месяц назад
Cheers mate superb 👌 ok 😉
@ManojKumar-s6v
@ManojKumar-s6v Месяц назад
Super explaination
@Bs987-ui1im
@Bs987-ui1im Месяц назад
😂😂😂bhai app hindhi me e video banao😂😂😂😂
@VijayKumar-gz5gu
@VijayKumar-gz5gu Месяц назад
Why you not done with motor efficiency for selecting MCB and contactor ??? Any reason behind that???
@fizzajaffery7057
@fizzajaffery7057 Месяц назад
SIR I have written text by using single line text in my electrical drawing the text is once written correctly in sequence when I exit from the txt command all the texts that I had written shift to the right side 😢Plz tell me why it's happening
@SamarthDwivedi-tl6hm
@SamarthDwivedi-tl6hm Месяц назад
60 milli seconds me 0.6 seconds lols.
@iqbalkhan-yu1ie
@iqbalkhan-yu1ie Месяц назад
good
@lakhdeepsharma1985
@lakhdeepsharma1985 Месяц назад
Sir 2000amp ke liye LT mein kitne ki cable 3 core lage gi..??
@sachinlandge6401
@sachinlandge6401 Месяц назад
Make videos on external lv and main incoming line. Pipes chembers
@SonuHiwale-ro9dx
@SonuHiwale-ro9dx Месяц назад
Helpful
@anuj5084
@anuj5084 Месяц назад
Wrong
@rajbirsingh2020
@rajbirsingh2020 Месяц назад
Rough video bna diya
@Infonewsentertainment
@Infonewsentertainment Месяц назад
Where to learn mep complete operations and maintenance
@P.a.itachi_
@P.a.itachi_ Месяц назад
Bhai aap Hindi hi bol lo but achese samjhaao and yaa you are using mouse too much if you make proper lines then it will be easier to learn more
@thebreakdowntv6828
@thebreakdowntv6828 Месяц назад
Please more videos on MEP.... Thank you ❤
@AnnaHaro-ls9hi
@AnnaHaro-ls9hi 2 месяца назад
Show me a master switch controlling 4way switching please😅😅😅
@biswaranjan501
@biswaranjan501 2 месяца назад
Thank you sir
@bhalsingh985
@bhalsingh985 2 месяца назад
Very useful thanks Brother
@ninaa3162
@ninaa3162 2 месяца назад
If is possible please show us practically step bey step for better understanding
@dr.gireeshgnanadhas7743
@dr.gireeshgnanadhas7743 2 месяца назад
Simple but very informative with a lot of calculation and real examples. I love your channel.
@anilkamboj9779
@anilkamboj9779 2 месяца назад
Good
@karampudisrihari6781
@karampudisrihari6781 2 месяца назад
please share the clause for point of supply for public and private as per NEC
@nishantharanjith
@nishantharanjith 2 месяца назад
Wonderful explanation
@sankarasubramanian6682
@sankarasubramanian6682 2 месяца назад
Will the selection process change if you have large Induction Motors are connected?
@kumneger-ed9xx
@kumneger-ed9xx 2 месяца назад
thank you for your support ,it is good
@user-bd2mg8qe9v
@user-bd2mg8qe9v 2 месяца назад
1 sq mm Copper Cable Current Carrying Capacity: Copper cables with a cross-sectional area of 1 sq mm exhibit an impressive current carrying capacity of up to 30A, making them ideal components for electrical wiring
@user-bd2mg8qe9v
@user-bd2mg8qe9v 2 месяца назад
nice one
@sujithsurendran1241
@sujithsurendran1241 2 месяца назад
Does high rise society flat have LDB,Eldb etc?
@creativeprem7844
@creativeprem7844 2 месяца назад
Thankyou sir
@mehmoodhussain-zc3wc
@mehmoodhussain-zc3wc 2 месяца назад
Nice information
@phubtshering2639
@phubtshering2639 3 месяца назад
how did you get 366 KVA when you divide 293.04 Kw/ 0.8 ( power factor) , it should be 366 VA
@saddamhossain3504
@saddamhossain3504 3 месяца назад
Thank you sir, you have explained very well, I can gain a lot of knowledge by watching the whole video
@MerjiAqeel
@MerjiAqeel 3 месяца назад
10:00
@user-gf2ze8ur7w
@user-gf2ze8ur7w 3 месяца назад
Thanks you