HT Cable Size Calculation | Cable Sizing and Selection | Part 1 

MEP TECHNICAL WORLD
Подписаться 20 тыс.
Просмотров 18 тыс.
50% 1

In this Video, I have discussed about HT Cable Sizing Step by Step .
Current Carrying Capacity Methods .
As per NEC Standard
#cable_Size
To know More About Cable Please follow Links :
• Types of cable as per ...
• Types of Power Cable ...
• Types of Cable as per ...
• Type of Cable Part 1 ...
• Introduction to Cable ...
MEP TECHNICAL WORLD

Опубликовано:

 

22 фев 2023

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 19   
@sudarshanpobbati3947
@sudarshanpobbati3947 10 месяцев назад
👌
@healingmeditation5970
@healingmeditation5970 11 месяцев назад
pleaee make part2 of HT side cable selection
@mohamedkhalif1686
@mohamedkhalif1686 Год назад
salam which table is in bs7671 its similar to table 4h4a
@karampudisrihari6781
@karampudisrihari6781 2 месяца назад
please share the clause for point of supply for public and private as per NEC
@nadim606
@nadim606 8 месяцев назад
seen
@shivlok20143
@shivlok20143 Год назад
Can you give nec ref code for 11 kV cable size
@amarnathmishra1461
@amarnathmishra1461 Год назад
You are speaking of 100kva , but displayed as 1000kva.I am confused
@adilraza3645
@adilraza3645 10 месяцев назад
If the 25mmsq of cable arrivlved from table then why you moved to 240
@sujitmorbale5043
@sujitmorbale5043 6 месяцев назад
HT SIDE YOU DISPLAYED IN DRAWING 100 KVA TRANSFORMER ,IS IT 1000 KVA OR 100 KVA ?
@noelfaithfulkari2857
@noelfaithfulkari2857 Год назад
Why is power factor not considered?
@prlove3845
@prlove3845 Год назад
Why we take 100kva transformer
@bagumaderick5491
@bagumaderick5491 Год назад
sizing simplified
@mitech_mep
@mitech_mep 4 месяца назад
Wrong! there is no cable under 35 mm2 in HT line,3 core...
@salmananwar8370
@salmananwar8370 7 месяцев назад
Cable sizing information is wrong. If u consider 1000 kva that's amp capacity is 52 amp Let's move further Include derating factor 0.65 This is value of soil resistivity , depth of laying and temp factor 52/0.65 = 87 amps Available size is 50 sqmm 3core xlpe / PVC swa/PVC 1000 kva trafo short circuit is 0.85 ka another hand 50 mm cable short circuit rating is 7.5 ka Hence it's proof 50 mm square z sufficient. For safer side u can go for 70 sqmm
@ashokkumar-mk5uo
@ashokkumar-mk5uo 3 месяца назад
Sir please give me your number sir I have lot of Dout give me ur number sir it's very helpful for me
@Mohde666
@Mohde666 10 месяцев назад
voice is confusing voice 100kVA,written 1000kVA?
@MuhammadQasim-sc5gn
@MuhammadQasim-sc5gn 5 дней назад
Ur info is not confirmed in this vd because u r concept not clear
@abssakib2784
@abssakib2784 Год назад
False information
Далее
OG Buda -  Лазерный
02:27
Просмотров 130 тыс.
What is going on? 😂 (via haechii_br/IG) #shorts
00:15
BREAKER AND CABLE SIZES FOR ELECTRICAL CIRCUITS.
11:39
Просмотров 170 тыс.
Cable sizing and selection - Electrical Designing
8:29
Easy Guide to Cable Sizing and Cable Calculations
22:01
Cable Selection Method | Cable size calculation
13:08
Просмотров 3,3 тыс.
240.4  &  T-310.16  Conductor Protection and Ampacity
22:48