Тёмный
Matthew Yaney
Matthew Yaney
Matthew Yaney
Подписаться
Video inspection of a sewer line
10:35
6 лет назад
Mytee escape ETM
8:57
6 лет назад
Carpet cleaning Lima ohio
0:23
6 лет назад
Steam cleaning St. Mary's Ohio
1:19
6 лет назад
Sewer line repair lima ohio
0:18
7 лет назад
Sewer line repair lima ohio
0:12
7 лет назад
Lima Ohio water damage
0:54
7 лет назад
Sewer line repair lima ohio
0:41
7 лет назад
Sewer and drain cleaning Lima Ohio
1:20
7 лет назад
Lima ohio carpet cleaning
0:28
7 лет назад
Water damage lima ohio
0:16
7 лет назад
Sewer Cleaning Lima Ohio
0:29
7 лет назад
Drain Cleaning Lima Ohio
0:43
7 лет назад
Carpet Cleaning Wapakoneta Ohio
0:52
7 лет назад
Carpet Cleaning Lima Ohio
0:31
7 лет назад
Комментарии
@majesticcarpetcleaning4296
@majesticcarpetcleaning4296 Год назад
Is that the mytee twin turbo??
@matthewyaney1579
@matthewyaney1579 Год назад
Two regular hot turbos
@LoudStereoTINYDICK
@LoudStereoTINYDICK Год назад
The way you do it absolutely requires that you do dry strokes and youre still probably leaving the carpets soaked
@jeancarlossaxofonista8169
@jeancarlossaxofonista8169 Год назад
Cuanto te dura caliente el agua con el turbo hot
@chuckieward6077
@chuckieward6077 2 года назад
That seems like a waste of time. If you use a pro cam mount you won't have to add all that extra crap to do carpet cleaning. Also your truck looks like there's no room for anything
@darrennicholas860
@darrennicholas860 2 года назад
Looks like a fire hazard
@matthewyaney1579
@matthewyaney1579 2 года назад
Not at all. Make sure it's a 20 amp breaker and plug them all in separate rooms.
@darrennicholas860
@darrennicholas860 2 года назад
Lot of tanks
@ReinSman100
@ReinSman100 2 года назад
How would it do with one hot turbo.
@matthewyaney1579
@matthewyaney1579 2 года назад
Decent but you won't have heat long
@wecleanitall8333
@wecleanitall8333 2 года назад
What’s the secret to getting your mytee turbo hot? I run just one off my generator and the water turns Luke warm not 180 degrees. So, I just purchased a second mytee turbo recently and waiting on it to arrive. Will I notice a significant difference?
@CrackaSource
@CrackaSource 2 года назад
You're probably not getting enough power to your turbo. Try doing a test by plugging it into a home socket to see if it changes in heat. If not, you probably have a faulty unit and your new one should help!
@wecleanitall8333
@wecleanitall8333 2 года назад
@@CrackaSource you’re correct. I purchased a second mytee turbo . I now plug both sets into opposite sockets in peoples homes and boy I have never seen so much steam!
@wecleanitall8333
@wecleanitall8333 3 года назад
I am thinking about buying a etm mytee. Are the motors in series or parallel?
@matthewyaney1579
@matthewyaney1579 3 года назад
Not sure
@brijeshkumarpatel9581
@brijeshkumarpatel9581 3 года назад
Hi buddy just not understand why all this hadac when you have petrol truck mount available in market which use less space then this setup
@wecleanitall8333
@wecleanitall8333 3 года назад
What psi are you running in this video? These mytee can’t handle 500 psi consistently. By adding 2 more mytee turbos can the electric heaters keep up?
@wecleanitall8333
@wecleanitall8333 3 года назад
Wow 3 mytee turbos. Watching this is tempting me to purchase.
@matthewyaney1579
@matthewyaney1579 3 года назад
500psi
@clevelandchan
@clevelandchan 3 года назад
the heaters are the truth
@Jjournell1987
@Jjournell1987 3 года назад
Would you recommend buying this Mytee escape LX brand new or buying a used truckmount? I like the price for ETM and I live 30 minutes from Mytee in San Diego, just in case I need repairs
@matthewyaney1579
@matthewyaney1579 3 года назад
You can be down day's waiting on a truckmount to be repaired. Most of the issues I have had can be repaired in minutes with a pair of wire strippers and a flat head screw driver. Mytee is always quick to deliver parts. The only issue I have had is vac motors and that's after a year or two of everyday operation.
@runzization
@runzization 3 года назад
Mytee hot turbo? Good to have on hand no comparison to fuel fired though...
@Dinosdallas
@Dinosdallas 3 года назад
Just if he is using 3 or 4 hot turbo connected in line, because just 1 hot turbo it doesn't get so hot like that, just if the water is really hot in the solution thank. I have 2 hot turbo, just one with cold water it doesn't get hot.
@ajbacon2626
@ajbacon2626 2 года назад
@@Dinosdallas Hook up to heat in buildin and use one Hot turbo, much easier
@Dinosdallas
@Dinosdallas 2 года назад
@@ajbacon2626 i use a 1600psi pressure washer cold water with a regulator, i can not use hot water to boost the heater.
@NotTooExtreme
@NotTooExtreme 3 года назад
I think he is using the new 3 LX vac escape with a heat exchanger.
@extremesteamcarpet
@extremesteamcarpet 3 года назад
What’s the black line between each stroke ?
@icleangrout
@icleangrout 3 года назад
it's now 2020 -two years later. update? hows it working for ya? what was your setup cost? great video!
@matthewyaney1579
@matthewyaney1579 3 года назад
Working great set up cost was not very expensive. Plus no long term downtime as you sometimes have with a truckmount unit. Most issues can be repaired within a hour if you can get access to parts.
@jonescleaningservicellc8076
@jonescleaningservicellc8076 3 года назад
What psi are you cleaning with
@matthewyaney1579
@matthewyaney1579 3 года назад
450 to 500
@cliftonbell53
@cliftonbell53 4 года назад
How do you keep the heat I have one and run a 50ft and it dont steam like that? I have the vortex lite
@matthewyaney1579
@matthewyaney1579 4 года назад
I am using multiple
@thespeedjunkieo2904
@thespeedjunkieo2904 4 года назад
to much equipment. you spends your whole day setting up things.
@rkvantiflin
@rkvantiflin 4 года назад
I have seen your videos and really like your work! Especially using the turbo water heaters the way you do. Is this video with 2 or 3 heaters?
@matthewyaney1579
@matthewyaney1579 4 года назад
This is 2 I believe
@rkvantiflin
@rkvantiflin 4 года назад
@@matthewyaney1579 thanks for the reply, were you using normal cold water as well?
@methodcleaningsystems4784
@methodcleaningsystems4784 4 года назад
I noticed you have 3 mytee turbo heat boosters. Check out my Heat Saber hose insulation tests. Saved me about 25-35F at the wand. Doesn't need any fuel or electricity. Might be able to ditch one of those mytee's.
@methodcleaningsystems4784
@methodcleaningsystems4784 4 года назад
How did you ground the generator?
@matthewyaney1579
@matthewyaney1579 4 года назад
12 volt Battery is grounded to body on generator. Generator itself is not grounded.
@FirstClassFloorCare
@FirstClassFloorCare 4 года назад
Great set up! Have you 3 Mytee heaters on at once to get that heat?
@matthewyaney1579
@matthewyaney1579 4 года назад
Tried 3 but not much better than 2 so mostly two now
@FirstClassFloorCare
@FirstClassFloorCare 4 года назад
@@matthewyaney1579 Great, how do you situate them, one at the machine and one in the house or 2 in the house?
@matthewyaney1579
@matthewyaney1579 4 года назад
@@FirstClassFloorCare 2 in the house 50' from wand
@FirstClassFloorCare
@FirstClassFloorCare 4 года назад
@@matthewyaney1579 Thanks dude, I have a Magma heater atm, So gona get a Mytee and try both at once 👌😎 Thanks for uploading!
@carpetcleaning999
@carpetcleaning999 4 года назад
Overall I love it, you did a great job. Are you still with this setup? Highly recommend you to buy the little giant, will be easier for you to set up.
@matthewyaney1579
@matthewyaney1579 4 года назад
I like the little giants but quit using fuel powered heat after a van fire
@carpetcleaning999
@carpetcleaning999 4 года назад
@@matthewyaney1579 ohh wow that sounds Scarry. No issues with me since I have started 6 years ago with my Etm set up.
@carpetcleaning999
@carpetcleaning999 4 года назад
@@matthewyaney1579 I am really afraid to run a generator to power my Etm. Currently I am 100% plugging to customer's outlets but some jobs I park little further and I use a longer extension cords which is not fun, I am thinking of putting a generator this season, how safe do you think it is?
@matthewyaney1579
@matthewyaney1579 4 года назад
@@carpetcleaning999 I would be confident and running a generator in your truck but I would build a rack so you can slide it in and out
@carpetcleaning999
@carpetcleaning999 4 года назад
@@matthewyaney1579 I am thinking of getting a dual fuel generator and mostly run it with propane cleaner burn and place the generator close to the back door just like yours.
@fdt281
@fdt281 4 года назад
Probably no heat in the restaurant that winter day ;)
@matthewyaney1579
@matthewyaney1579 4 года назад
It was 69° in there.
@runzization
@runzization 3 года назад
@@matthewyaney1579 was the heat a diesel "hot link?"
@miguelteran-raful2718
@miguelteran-raful2718 4 года назад
how do you like your mytee hot turbo?
@matthewyaney1579
@matthewyaney1579 4 года назад
Love them I feel they are way safer than fuel powered heaters
@FirstClassFloorCare
@FirstClassFloorCare 4 года назад
Nice set up, Have you 3 Mytee heaters connected at once?
@RonRivet
@RonRivet 4 года назад
Thanks so much for posting!
@RonRivet
@RonRivet 4 года назад
Nice!!
@justina3126
@justina3126 5 лет назад
What’s your heat source
@Zled1
@Zled1 5 лет назад
What an epic waste of money...Just buy yourself a regular truckmount unit and save yourself that hassle. It is set up well though.
@matthewyaney1579
@matthewyaney1579 5 лет назад
You have way less maintenance with the escape and you can also have a backup and pull one out and put another 1 in instead of waiting for a week for a truck to be repaired
@Zled1
@Zled1 5 лет назад
@@matthewyaney1579 Ok i see what your saying...Maybe im looking at it on my current small business scale and two escapes alone would be pushing my budget. Thanks for the reply! I will not take away all the thought and care that went into this set up bc I was impressed.
@ronbowski72
@ronbowski72 5 лет назад
Nice, what are you using for heat?
@Fredthehead2
@Fredthehead2 5 лет назад
Wow a setup . Budget cleaner . Get a real TM to clean carpets . Probably a budget cleaner in the cleaning bussiness
@zeromoldchicago2221
@zeromoldchicago2221 5 лет назад
Hey Matt hows the Maintence on the ETM? Going to get one soon. Anyway you can talk to me? 847-630-3837 Shoot me a text
@zeromoldchicago2221
@zeromoldchicago2221 5 лет назад
I have to get this! Who did your instal and where did you buy from so I can ask for advice
@matthewyaney1579
@matthewyaney1579 5 лет назад
I did the installation
@larrycobb7073
@larrycobb7073 5 лет назад
With the power & heat you have; you might consider a 14" wand. www.cobbcarpet.com/zen/images/wand14as.jpg
@tomd720
@tomd720 5 лет назад
Save yourself all the expense, setup time and hassle with hoses and use an oscillating pad machine with a peroxide boosted encapsulating product. It does a great job, especially on berber !
@DariuszKrak
@DariuszKrak 5 лет назад
What power generator you're running please?
@matthewyaney1579
@matthewyaney1579 5 лет назад
8500
@Enfermito421966
@Enfermito421966 5 лет назад
if you are only running say 50 foot hose a hot turbo will be enough to keep it steaming
@hotshot3d
@hotshot3d 6 лет назад
I had ordered the Jaguar 8.4 , but ended up returning it it due to so many issues with it. Bad layout IMO, excessive use of defoamer, bad pump, bad vacuum motor. All within the first 40 hrs of use. I returned it and got the Escape! Huge difference! Amazing layout! Impressive pump out system, a real ETM all around! doesn’t even seem to need defoamer! Love my Mytee ETM.
@matthewyaney1579
@matthewyaney1579 5 лет назад
@@inGodtrust5hmkj4 I will try and let you know
@Jjournell1987
@Jjournell1987 3 года назад
Sam, I bought a Jaguar Cub and that thing broke down on me the first two jobs! It also looked like a ice cream cart.
@bodystomp5302
@bodystomp5302 6 лет назад
Can you hook up a hose and run water directly from that, circumventing the clean water/solution tank?
@cleanritecarpetcleaning7091
@cleanritecarpetcleaning7091 6 лет назад
Glad your liking your new Escape, i got one about a month ago and like mine as well, like your set up with the on board fresh water tank and larger waste tanks, I plan on adding an onboard fresh water tank as well, I run mine off a generator as well unless i'm close enough to use the dryer outlet. Only difference is I have a little giant propane heater instead of the hot turbo heaters, you should seriously consider getting the little giant propane heater and thank me later. If nothing else it'll be less to set up and break down, and you'll never run out of hot water, I had a hot turbo, it slowed me down, you have to adjust how you clean so it can keep up, not the case with a little giant heater, if we were side by side and keyed our wands and held them open spraying water, you'd run out of hot water way way before me, in fact i'd probably not run out at all, trust me on this. you could have just about had one for the money you spent on 3 hot turbos
@carpetcleaning999
@carpetcleaning999 4 года назад
@Eric Thompson if you haven't already got the little giant highly recommend it.
@matthewyaney1579
@matthewyaney1579 4 года назад
Yeah but after a van fire we went to different heat options to reduce extra fuel in the trucks
@runzization
@runzization 3 года назад
@@matthewyaney1579 for just over $2k you can have 150+ft of "OuickHeat" A diesel system that doubles as a Powerwasher. Runs off 15amp using extractor with generator @3circuits, uses only a little diesel and No heat loss when wand is closed. I think it's an upgrade over little giant.