GREENSUN SOLAR is China manufacturer of Solar PV Panels and Storage Lithum Ion Batteries and also the professional provider of complete Solar Energy Storage System, ESS, HESS.
The most advanced PV technology: 166mm 182mm 210mm Large wafer solar modules 420W 460W 550W 620W 685W for Residential and C&I application.
Lithium Iron Phosphate Battery: 48V Powerwall home Battery
High Voltage Lithium battery for Commercial Application.

Комментарии
@markb3787
@markb3787 25 дней назад
So this has not helped at all In fact it is blatantly confusing My friends deye is connected to his house At night to force the inverter to use his very expensive battery to run the house he has to manually turn off his grid supply Then turn it back on when the battery runs flat Why does he have to do this ? Why does the inverter not use battery first and then grid automatically ? There is no setting I can find to tell it to do this My green banks inverter is as simple as selecting the mode that does that, if deye is better why is it so confusing ? Would love some help with this ❤
@markb3787
@markb3787 25 дней назад
P.s he never wants to sell to the grid EVER and he is not connected in that way to be able to do that
@iulseyer
@iulseyer 27 дней назад
When and when not to use CT?
@honarkhalil9759
@honarkhalil9759 2 месяца назад
Price??
@st11985
@st11985 3 месяца назад
Hi, nice job! Looking at 6:04 for example: Is there a way to limit the inverters connection to the LOAD (Home Load + Grid) connection (for example to 2000W) in total? And this while not limiting the the Backup Load connection (3.6 KW, 5KW, 10KW whatever the inverter can max). I would like to use all the possible power at Backup Load port. And additionally I would like to do "Zero export to CT" (not selling anything). But my setup only allows to use a wire from inverter to grid direction that cannot handle the max. power of the inverter. So my Home Load can and should only be supported to the 2000W. Also taking from Grid to Backup Load (or battery charging) has to be limited to the 2000W in total. Is this possible somehow? Thank you.
@manjulabw
@manjulabw 3 месяца назад
what happen grid power lost in 80%? it will continue battery?
@THEZEST1357
@THEZEST1357 2 месяца назад
you can only supply the backup load with the battery power. So your home would need a cutover switch and so your switchboard could be reverse fed by the "load/backup" output instead of the "grid" output.
@GiftedInspOanimation
@GiftedInspOanimation 6 месяцев назад
Am having issue with hybrid inverter using 10kwn greensun lithium battery. Can you help me
@GREENSUNSOLARENERGYTECHCOLIMIT
@GREENSUNSOLARENERGYTECHCOLIMIT 6 месяцев назад
My whatsapp or wechat: +8615855110194
@geodyleemiculob-zd3mz
@geodyleemiculob-zd3mz 9 месяцев назад
Hi how to order this battery pack
@GREENSUNSOLARENERGYTECHCOLIMIT
@GREENSUNSOLARENERGYTECHCOLIMIT 9 месяцев назад
hi friend, this is our e-mail: info@greensunpv.com and whatsapp: +8615855110194 or you can give us your e-mail, we will send e-mail to you.
@GREENSUNSOLARENERGYTECHCOLIMIT
@GREENSUNSOLARENERGYTECHCOLIMIT 8 месяцев назад
hi, this is Jessica from Greensun Solar. My e-mail is info@greensunpv.com whatsapp or wechat: +8615855110194 You can contact us and order from us
@RyanBautista
@RyanBautista 9 месяцев назад
Hi, i do have a CH150ah (changhong brand) lifepo4 battery but the CAN port is disabled. Any solution or way to ENABLE it. Hope you can help
@ramilnaciongayo6455
@ramilnaciongayo6455 9 месяцев назад
Same problem here. My Deye hybrid inverter cannot communicate with Changhong lifepo4 battery pack BMS.
@RyanBautista
@RyanBautista 9 месяцев назад
@@ramilnaciongayo6455 i think theres a correct pin assign to each wire as I did some reasearch. I’m gonna try it
@ramilnaciongayo6455
@ramilnaciongayo6455 9 месяцев назад
@@RyanBautista i hope you can help us find a way to fix the problem of Changhong CH48150 lifepo4 battery module connecting with Deye hybrid inverter. thanks in advance brother.
@RyanBautista
@RyanBautista 9 месяцев назад
@@ramilnaciongayo6455 yes i’ll update you. I did some deep research about this issue. I’ll try to crimp the cable for this type of battery
@ramilnaciongayo6455
@ramilnaciongayo6455 9 месяцев назад
@@RyanBautistaif you noticed, the menus in the display of these battery modules are similar to the Changhong CH48150. but Changhong BMS has a problem communicating with Deye hybrid inverters.
@Bobsyourunclereally
@Bobsyourunclereally 10 месяцев назад
Could this work with a vehicle to load (V2L) enabled electric car instead of a generator? If so could the inverter be programmed to switch to charging the house battery e.g. so say at night (or whenever) plug in the v2l enabled vehicle to the inverter (say before going to bed) and when the house battery goes under a certain amount of charge e.g. 50% the inverter starts using the charge in the v2l vehicle to top up the house battery?
@tommyleesue
@tommyleesue 11 месяцев назад
Can U expand this and explain how to use "time of use" in "seling first" mode, please. Especialy what exacly meens "power" column in "time of use". It is realy good job you have done :)
@lua-nya
@lua-nya 6 месяцев назад
Any luck searching for these answers? I think selling first exports up to max export power before charging battery from PV or GEN. On time slots with GRID charge on, I believe it doesn't export.
@lua-nya
@lua-nya 6 месяцев назад
On regards of the Power in the time of use, I think it's total load power or inverter power, whichever is higher.
@briekhnaa
@briekhnaa 11 месяцев назад
Still i dont understand zero export to load and zero export to load ❤️🤔
@tommyleesue
@tommyleesue 11 месяцев назад
zero export to load meens zero export to home load - just delivers energy to backup load zero export to CT meens zero export to grid - delivers energy to home load and to backup load
@briekhnaa
@briekhnaa 11 месяцев назад
@@tommyleesue thank you.
@aalemsyed2145
@aalemsyed2145 10 месяцев назад
I've been searching for this answer for the last few weeks...seen tens of RU-vid videos and read dozens of articles on solar system....but nowhere has this been explained as clearly as you have done. For the first time I have actually understood what the terms zero expert to load and zero export to CT mean. Thank you
@THEZEST1357
@THEZEST1357 2 месяца назад
@@aalemsyed2145 CT just measures power in or out to the grid. Basically CT mode is for those tied to the grid, zero to load is for people using off grid systems with generators etc or alternatively if they have an existing solar system with micro inverters etc..
@PrezesPL
@PrezesPL 29 дней назад
@@tommyleesue and if the battery is 100% charged and there is surplus power from PV, is it possible to block export to the grid network? (4:46 film)
@baby333
@baby333 11 месяцев назад
I love your Deye videos! I have a question, Say I have 01:00 - 4:00 to drop battery to 60%, NO Charging, and I just want it to use the battery not grid to save bills. What if at 3:00 I already reached 60%? what will happen since i still got 1 hour to go? will the system shut down since I dont have charging enabled? or will it allow it to go lower? 1. I am guessing if I reached 60%, and I had GRID on, it would use grid and not shut down, correct? 2. If I did not have grid, and it reached 60%, and i still got 1 hour to go, no charging enabled what would it do? Any recommendation? thanks!
@lungbernd
@lungbernd 4 месяца назад
Hi there, at least you can set up the timetable. Normally you can use LiFePo batteries quite in a good range. Discharge until 20 % is ok. So let the batteries work at night until they reach 20 %, then Grid will "jump in" until the production of your panels starts.
@baby333
@baby333 4 месяца назад
@@lungbernd Thank you yep got it figured out <3 love Deye system, 10000x better than Growatt
@willdatsun
@willdatsun Год назад
on the diagram it says Gird
@Nexett1
@Nexett1 Год назад
hello friend, I have the same inverter with battery sku11523 vtac, connected with bms via cable and it is detected, but when it reaches 80%, it stops and takes everything from the network, if set as voltage battery it works, if set lithium and yes connect to the bms the soc does not reach more than 80 , can you help me ?
@estebansanchez9543
@estebansanchez9543 11 месяцев назад
System Work Mode -> activate "time of use" -> Change "Batt" from 80% to whatever You want to. The Inverter does what You tell it to. You told it to Stop unloading the battery at 80% 😅 But that's the Standard setting, I had the same problem with my deye.
@GREENSUNSOLARENERGYTECHCOLIMIT
@GREENSUNSOLARENERGYTECHCOLIMIT 10 месяцев назад
hello, we can try to help you. Here is my e-mail and whatsapp: info@greensunpv.com +8615855110194
@Doing_Life
@Doing_Life Год назад
Great little video .... been searching the web for specific Deye Hybrid settings
@SimplyTek1969
@SimplyTek1969 Год назад
Hi Whats the BMS brand?
@saonicom8821
@saonicom8821 Год назад
We have purchased 3 of these 10Kwh batteries, after 2 months 1 battery had a dead BMS, Greensun refused to replace it, A few months after one connector not well attached at the factory on a second battery got burnt, no replacement done by greensun, 2 years later 4 cells dead on the third battery, Greensun did not even be polite to answer !!! They claim 12 years warranty, it's just lies, Greensunpv is very low quality, greensunpv is just very bad, don't waste your money with them
@ewartbain5463
@ewartbain5463 Год назад
I have a brand new one which is not powering up my inverter and I can get them to answer my calls, emails, and whatsApp messages. I can believe that.
@coenraadloubser5768
@coenraadloubser5768 Год назад
Wow. 340W panels. Almost 300 of them.
@user-vg2fq4jk2d
@user-vg2fq4jk2d 2 года назад
how to order
@GREENSUNSOLARENERGYTECHCOLIMIT
@GREENSUNSOLARENERGYTECHCOLIMIT 9 месяцев назад
hello, we have official website and also have Alibaba website. here is our contact: info@greensunpv.com whatsapp or wechat: +861585510194
@AshokKumar-nn6sd
@AshokKumar-nn6sd 2 года назад
Is this battery available in india?
@GREENSUNSOLARENERGYTECHCOLIMIT
@GREENSUNSOLARENERGYTECHCOLIMIT 9 месяцев назад
we ship from China
@zainkhawar4564
@zainkhawar4564 2 года назад
You can choose for one of the above gifts
@nelsonomhan5401
@nelsonomhan5401 2 года назад
It looks very good and effective
@GREENSUNSOLARENERGYTECHCOLIMIT
@GREENSUNSOLARENERGYTECHCOLIMIT 9 месяцев назад
YES, our products are very high quality and nice
@ricke3154
@ricke3154 2 года назад
Greetings, I have that inveter and lead acid batteries, how can I program to see the% that remains of the battery?
@ricke3154
@ricke3154 2 года назад
Greetings, serial Well a video with its functions and programming.
@GREENSUNSOLARENERGYTECHCOLIMIT
@GREENSUNSOLARENERGYTECHCOLIMIT 2 года назад
YES, it is multi-functional and can be programmed
@ricke3154
@ricke3154 2 года назад
Saludos, serial Bueno un video con sus funciones y programacion.