i just hope you stayed with all white theme for the inverter, now the new look is same with other brands but I'm hoping there is lot of great updates 😁
Hi, could you also make a video with communication to generator ATS (automation ON/OFF) as this will help for long power outage during typhoon. Complete circuit diagram would be helpful. Thanks
What does lithium mode do? My battery was set to lithium and I changed it to use battery % and now I can't switch it back. I hope it's not destroyed 😢 would it still charge once there's sun?
Hi! What if there is no power supply from grid (blackout) during 10:00 to 15:00, does the hybrid inverter capable of providing power to home and back up load and charge the battery simultaneously in case the PV power is sufficient?
Weiß jemand wie der Generator betrieb bei 2 3-phasigen Hochvolt-Geräten im Master- Slave betrieb aussieht. Können die Generatoreingänge einfach parallel geschalten werden?
hello, I can't find the answer in the manual: for connecting a SM Eastron SDM230, which colors from rs485 / inverter go to A and B / 5 and 6 from SM? possibly the grounding... thank you very much! my invertor: DEYE 6 kW, hybrid...and is mandatory if already CT installed and works?
Iniciei a migração mas nada aparece na aplicação e está a informar apenas que está com a migração em progressão há mais de 30min. É normal? I started the migration but nothing appears in the application and you are only informing that you have had the migration in progress for more than 30 minutes. Is it normal?
Já conclui a migração! A aplicação tem dados novos e aparenta ser muito melhor que a SOLARMAN. No entanto não permite a migração de outras fontes de energia como a SOLARMAN. Por exemplo tenho um inversor de outro fabricante por causa de um Aerogerador e não fez a migração, que pena!😢 The migration has already been completed! The application has new data and seems to be much better than SOLARMAN. However, it does not allow the migration of other energy sources such as SOLARMAN. For example, I have an inverter from another manufacturer because of a wind turbine and did not make the migration!😢
Nice presentation, I have a 6 kW Deye inverter equipped with a Eastron smart meter.....but I can't set zero export power to grid.... during a normal day I still export more than 5 kW... that is not good... Can you tell me what do I have to do for it? It's about Eastron SDM230 Thanks
Hi! I have a DEYE SUN-10k-G (grid tie), how many strings of PVs this inverter can hold? currently i have 2 strings connected of 5-550w panels each. I plan to add another 2 strings to max the harvest. If i can still add 2 strings, can I use higher capacity rating PV, like 680w 0r 720w? my roof cant hold many more PVs that's why. thanks!