£280 for a worthless piece of paper? Electrician 

Подписаться
Просмотров 67 тыс.
% 1 085

hrservices.uk/ if you need real electricians.
Today we discover not all expensive eicr are good.
www.consumerunitworld.co.uk/fusebox-389-c.asp
CJR10 for 10% off at consumer unit world for all things fusebox plus any accessories.
If you need any sort of website design, hosting or support. Give Kip a messages he’s a great guy.
ru-vid.com
kiphakes?igshid=1j4x6kg8pndi5
www.kiphakes.com/
👇 Want to get you hands on some epic tools.👇
www.electoolsaway.com/
Because we don’t do patreon!!
This video is for entertainment purposes only please dont try to copy or recreate this video in anyway. Do so at your own peril!!!

Хобби

Опубликовано:

 

14 апр 2021

Поделиться:

Ссылка:

Скачать:

Готовим ссылку...

Добавить в:

Мой плейлист
Посмотреть позже
Комментарии : 190   
@russellshaw485
@russellshaw485 3 года назад
EICRS !!! For me to say it’s disappointing is an understatement. There are so many varying opinions between electricians . As a managing agent seeing over 150 EICR reports come in in the last year it’s so worrying to see clearly the some of the people we are meant to trust don’t do what they should . What you have found in this video clearly shows this is a major issue . How do any of us know which reports we can rely on? The biggest thing I have noticed are the number of electricians that seem to box clever to get a satisfactory result . In the rental Sector the governments idea was to make testing mandatory to make rented accommodation safer. How can this be working when a property with no RCD protection be deemed satisfactory. On the research online I’ve seen provision of RCD protection is a potential lifesaver so why not mandatory for rented homes ? It just doesn’t seem to make any sense. Some electricians are saying they can do three / four EICR reports in a day and some saying you can only do one or two if done properly ? there seems to be so many different views . We have had clients get a second opinion after receiving an unsatisfactory report then to get a satisfactory one from the second guy ? How is all this possible when the regs are supposedly clear? Anyway sorry for the rant 😂😂 I love your videos . You clearly know your stuff and back it up with hard evidence, thank fully I found two guys to help with all our reports and remedial who are like you and do it right. 🙂
@AndyK.1
@AndyK.1 3 года назад
Nice to hear a different perspective
@effervescence5664
@effervescence5664 3 года назад
So I have had a full day EICR and done 2-3 in a day, it depends on property size/if you've worked on it before so you're familiar with the system etc. Also RCD is great but you can't force people to have RCD protection when it wasn't needed to previous versions of BS 7671 it is not retrospective yet most companies will test to the new regs not what complied when it was first installed (any alterations have to meet with their respective versions at the time of install though). At the end of the day just find a company that won't bend the truth, sometimes items need replacing and work needs to be carried out but it should not be a given. I once had to attend a lovely country rental for a unsatisfactory EICR due to a shower that a young lad from another company picked up - he stated IP rating of the electric shower compromised due to the plumber cutting out the top left hand side to bring the water supply and the cable into the shower Via trunking mastiked in. When I attended could not see an issue with that at all, done properly and used the correct cut outs so it didn't affect the IP rating of the shower - the issue that I found was the shower was 10.5kw on a 6mm cable 15 meters from the consumer unit and way over sized for the cable so the shower needed changing to a 7.5kw and the cable partially replacing. I called up the governor of the company an forwarded the photos just so he could inform the young lad that did the report for better future knowledge. So TLDR; experience and training makes a massive difference between EICR's unlike the very exacting standards of Gas where it always gets upgraded or disconnected if unsafe.
@KH-bs2bz
@KH-bs2bz 3 года назад
As a managing agent how much do you pay electricians to complete a EICR?
@russellshaw485
@russellshaw485 3 года назад
@@KH-bs2bz we were quoted 155 plus VAT as we had large numbers
@russellshaw485
@russellshaw485 3 года назад
@Mark Sesum I agree and I am spending lots of my time trying to explain to landlords that even with C3’s and a satisfactory result on the report if anything was to happen and they had ignored the recommendations to improve they’re still open to possible prosecution because the legislation for landlords is that they must use all due diligence to ensure the property is safe for rental purposes. We want all the properties we manage to be totally safe in all aspects including gas and electric’s. I thought the legislation coming in was to help with this but clearly it just seems that some people are trying to get a satisfactory report and then just ignore any C3s raised . Thankfully almost all of our landlords are listening to the advice and have instructed any relevant upgrades.
@busman2000
@busman2000 3 года назад
You're both so lucky to have three professional stress relief counselors on hand at all time whilst you were working.
@mrgfromoxford8644
@mrgfromoxford8644 3 года назад
I love that james doesn’t know where lock off kit is and Chris forgets which way it goes on every time 😂. Not hinting at anything honest 😂.
@georgelelliott7950
@georgelelliott7950 3 года назад
Chris always carry’s out safe isolation procedures don’t you Chris 😉 nah jsut joking love the videos keep them coming Chris take care mate 👍👍👍
@15isto2
@15isto2 3 года назад
Loved the cat action
@JanSilins
@JanSilins Год назад
Just could I get your learned opinion on the separation of the consumer unit and the gas meter. The relevant regulation reads as follows…. “BS6891-2005 8.16.2 Separation of installation pipework from other services. Where installation pipes are not separated by electrical insulating material, they shall be spaced as follows: a) at least 150 mm away from electricity meters and associated excess current controls, electrical switches or sockets, distribution boards or consumer units;” So this would suggest a non conductive separating material such as plastic rather than a fireproof one as you seem to be suggesting. However I am not clear myself as to what the exact risk is. Should a fire develop in the consumer unit, it would get very hot so a fireproof barrier, not a plastic one would make sense. Therefore I can’t quite figure out why the regulation mentions electrical insulation material.
@joesouthgate
@joesouthgate 3 года назад
150mm separation between gas pipe/meter and consumer unit 👍
@we-are-electric1445
@we-are-electric1445 3 года назад
From the On site Guide 150 mm - S 2.3 suggest insulating material rated to 230 v over pipe or insulating material interposed
@aktelectricalaktelectrical4
@aktelectricalaktelectrical4 3 года назад
Thanks for the discount code Chris. It works a treat. As far as apprentices go, I think they should do a bit more than unpack the consumer unit 🤣
@spookyboo3164
@spookyboo3164 3 года назад
It looks a lot neater then some of the boards I've worked which were an absolute mess
@carforumwanker
@carforumwanker 3 года назад
Pimlico plumbers would have wanted 2 x guys at £800 per day plus VAT and about 400% on all parts fitted
@dangranet7621
@dangranet7621 3 года назад
Cheap .
@computeraddic675
@computeraddic675 2 года назад
And then they went on a holiday for two weeks in the Caribbean Islands??Paid by the customer?
@ollydearden
@ollydearden 3 года назад
Glad you avoided any gaping holes
@ped0000
@ped0000 3 года назад
Get that lad doing some work. Chuck him in at the deep end and let him figure out things himself. Build up his confidence and bring him out of his shell. He should have had the bonding done before you had the board on. Look how far batman's boy has come. Not being nasty just an observation.
@Romeworld95
@Romeworld95 3 года назад
Definitely agree. Chris just does all the work and has James sitting around faffing
@davecowan9466
@davecowan9466 3 года назад
You’ll never progress stood watching constantly, not in the long run anyway.....get him in at the deep end and he’ll learn quicker/gain confidence and start earning you money! Will also keep him interested 👍🏼
@NapierNimbus
@NapierNimbus 3 года назад
Love the cats. Am not a sparky but I can see how very thorough and neat. James lucky to be apprenticed to you to see how it should be done.
@ctb1690
@ctb1690 3 года назад
Hi , correct me if I’m wrong with my input on this consumer unit in the customers premises cupboard ... I’m seeing three things in one cupboard that shouldn’t be together/ not putting the blame in your direction. I guess this was a lazy way from the former installers? Constructive criticism to the chat 💬 on the previous installers - not on this video (CJR) please be kind
@jaycee1980
@jaycee1980 3 года назад
Whoever did that previous EICR should be made to resit his certification!
@bradh2066
@bradh2066 3 года назад
Exactly how I do up the terminals in the board. Lowest setting get it all in then finish with the tourqe
@paultipton743
@paultipton743 3 года назад
I had a callout on Saturday which I arrived at 12am after travelling 70 miles( I was asked if I could cover the weekend) with electrics tripping (Ringmain socket fault),neutral to earth fault, it had a test date sticker of just a few years ago I found a few metal flush boxes no grommets, cables tight to get the socket fronts off , the actual fault was a back to back socket wired in 1.0mm flex off an existing lounge socket to a adjoining shed that had overloaded the cable when a tumble dryer and a new hot tub were both used in it,tenant said they were like that when they moved in. didn't get home until 4am, didn't look a good eicr
@farmerdave7965
@farmerdave7965 3 года назад
Apprentices are worth their weight in gold. Please treat them accordingly.
@pietkaify
@pietkaify 3 года назад
So when your torque screwdriver is set to 2.5nm an click straight away. Does that mean your cordless screwdriver could have potentially over tightened the terminal prior?
@Cjrelectrical
@Cjrelectrical 3 года назад
No there’s still resistance to torque it up.
@marymadigan9707
@marymadigan9707 2 года назад
What a difference in the board super work as always 👏🇮🇪😎
@GrenPara
@GrenPara 3 года назад
I like your videos so thanks for making them. Here only one wire per breaker in the panel is allowed by code.
@tazdevil875
@tazdevil875 3 года назад
@cjrelectrical .. careful Chris, name showing at around 11.55 - 12:00 .....
@gordonm2821
@gordonm2821 3 года назад
Has been blurred out now
@train4905
@train4905 Год назад
Fantastic job chris and james
@kiphakes
@kiphakes 3 года назад
Cheers for the shout! 👍
@8inary
@8inary 3 года назад
Nagy was a milwaukee fan boy, but something changed and he went full on bosch. Me I like DeWalt and of course theres others, milwaukee sometimes has the speed edge ....sometimes except the new DeWalts drills which are faster at drilling.....just sayiin!! but when you compare that against pricing, I find it hard to justify. But lets face it, when you get to DeWalt, Milwaukee or Bosch etc your going to get a decent tool that will work when you pick it up. Theres always a contests, like back in school with computers, atari vs commodore, cameras, Nikon vs Cannon or even saga vs Nintendo, the war continues, just go with your budget and be happy :)
@amarcy5369
@amarcy5369 3 года назад
Yes Chris it does sound like a drive by test sheet , one thing I would say to people when you use crock clips make sure there tight . It’s amazing the difference it can make to your readings , also the person who filled the test sheet in is as you said totally confused about cat 1,2, and 3 . And all in a complete waste of time and money. Still the cavalry road over the hill to save the day . 🤣👍👍👍
@Ragnar8504
@Ragnar8504 3 года назад
A surprisingly thorough drive-by though, if he bothered to scribble the made-up test results on the bus bar covers! The lengths some people go to just to do something wrong.
@Fishbait075
@Fishbait075 3 года назад
Asking out of interest... would Nottinghamshire be too far away for a EICR and board replacement, for you to consider?
@Cjrelectrical
@Cjrelectrical 3 года назад
👎🏼
@Fishbait075
@Fishbait075 3 года назад
@@Cjrelectrical Awwww. I would have showered you in cookies :P
@nw5835
@nw5835 3 года назад
@@Fishbait075 Excuse the intrusion, what was Chris's reply to your Q or is it those marks under his name, are they internet speak meaning something, I'm an oldie so don't know all the shortcuts. Thanks in advance if you can explain.
@Fishbait075
@Fishbait075 3 года назад
@@nw5835 He gave it a thumbs down. Which I read as "no way buddy, Nottingham is WAY outa my way" :)
@jimsters1234
@jimsters1234 3 года назад
Hi. Keep up the good work. What camera do you use and what headmount do you have on some of your videos? Thanks
@ashmanelectricalservices4318
@ashmanelectricalservices4318 3 года назад
One look at the IR readings would have told me everything I need to know about the previous EICR. Complete and utter fabrication, my guess is he took a few Zs readings and made-up the rest.
@Geeraffe
@Geeraffe 3 года назад
owner supplies biscuits and cats - I think he wants a discount? Great job and very informative as always cheers!
@keithbrown339
@keithbrown339 3 года назад
Those earth bonding clip were widely used on Crest Homes built late 60s to mid 70s.
@simonabbott7323
@simonabbott7323 3 года назад
Not just Crest Homes, but many others in that period. FYI, by the end of 1977, G/Y colours were mandatory.
@jacobedmonds305
@jacobedmonds305 3 года назад
Chris - did you take the old board away? And if so do you have a use for the contactum breakers? I’m having a mate trying to get hold of some?
@thomascoles779
@thomascoles779 3 года назад
Hi mate, love the content. I’m not a sparky but looking at a career change and your videos are definitely steering me. I’ve seen on a few of your other videos you have ‘pablo’ in to do the work on the tails for you? What’s the reason behind that? Is it a certification/qualification thing or? Cheers
@Cjrelectrical
@Cjrelectrical 3 года назад
Pablo might be a figure of my imagination 🤷🏻‍♂️
@aktelectricalaktelectrical4
@aktelectricalaktelectrical4 3 года назад
Nice job again Chris. EICRs are a good opportunity for good electricians to do good work and make good money. Unfortunately they are also a good opportunity for con artists to rip people off as well. If the house owner doesn't bother to check the requirements then it's their fault. We can only do it right when we get a chance to and sleep well at night knowing we have made a property safer.
@jabx1231
@jabx1231 3 года назад
Why isn’t there a need for testers to rechecked and calibrated periodically, I worked in telecommunications most of our testers and meters needed annual calibration
@Cjrelectrical
@Cjrelectrical 3 года назад
There is.
@daxw2460
@daxw2460 3 года назад
There is of course...
@pauledwards9493
@pauledwards9493 3 года назад
Who used the cat litter tray then? Top stuff as always!
@lucivarsadiablo4191
@lucivarsadiablo4191 3 года назад
I don’t have a cat.. well who’s kitty litter did I just shit in?
@deano6188
@deano6188 3 года назад
All that silicon to stop fires! AND gives the next sparky a head ache when adding a circuit. Use Intermittent pads on back of fuse box if your rear entry and running down wall. no mess unless theres a fire. (Use a label on inside of box to state you've padded the back so next sparky knows your actions and doesn't become a silcon twit!)😂👍 Great vids.... keep them socks pulled up!💥🧦
@Cjrelectrical
@Cjrelectrical 3 года назад
Could always gland into the top bottom or sides if they can’t enter the rear easily.
@davidhooper6532
@davidhooper6532 3 года назад
Purrfect video Chris! Love the cat action. Only go to clients that have cats from now on🤣🤣
@ShadowzGSD
@ShadowzGSD 3 года назад
about f'ing time James had some proper socks on.
@rosstrent8595
@rosstrent8595 3 года назад
Loving the vlogs but.... the ginger cat wasn’t waiting for its owner to come home when it was pining at the door it simply wanted to go out..🤣
@daviesswanseaboy7158
@daviesswanseaboy7158 Год назад
How much did you charge for that job ?
@Swa33er
@Swa33er 3 года назад
What screwdriver bit are you using in the Draper Torque driver to tighten the breakers?
@mark123655
@mark123655 3 года назад
Ignoring the poor bonding work and EICR, Why did the customer want a new board? it at least appeared relatively new, albeit didn't have many spare ways
@ADF-js9vi
@ADF-js9vi 3 года назад
If you do 3 EICR's in a day, is the 3rd one as good as the 1st?
@simonabbott7323
@simonabbott7323 3 года назад
Cat is not waiting for James! Cat wants out!
@petermaidment1175
@petermaidment1175 2 года назад
Great deduction 'this has not been out since it was put in!!' :)
@g.williamswilliams8442
@g.williamswilliams8442 3 года назад
Great video,.. entertaining,. As usual
@haydenuk02
@haydenuk02 3 года назад
Excellent work and thanks for sharing this with us take care
@Fifury161
@Fifury161 3 года назад
5:50 - when you said that it made me think that the electrician was in a rush to sign of the electrics *cough*
@carforumwanker
@carforumwanker 3 года назад
How do you prefer the Kewtechs to Meggers/Di-logs etc ?
@Cjrelectrical
@Cjrelectrical 3 года назад
Kewtech is not over complicated for my tiny brain.
@razer192
@razer192 3 года назад
Why do you loop the meter tails ?
@davidwinch57
@davidwinch57 3 года назад
Hi Chris What grommet strip and glue do you use Thanks
@David_11111
@David_11111 3 года назад
yay .. love the CU mounting detail :)
@camperchris
@camperchris 3 года назад
The irony of the previous sparks name :)
@leewillelectrical5413
@leewillelectrical5413 3 года назад
😂
@blazeapolloz3851
@blazeapolloz3851 3 года назад
Rush Electrics... seems like the man to go to
@darrenthompson6046
@darrenthompson6046 3 года назад
Looks like you ad so much fun with the cats 🐱 😜
@nigellewis804
@nigellewis804 3 года назад
Why don't you let James do a board
@PHealey1981
@PHealey1981 3 года назад
Real word jobs! Lovely stuff.👏🏼👏🏼👏🏼👏🏼
@roydowling2542
@roydowling2542 3 года назад
When you were tightening the buzz bar with the small compact where did lock off kit on the main isolator switch disappear to?
@gkbailey540
@gkbailey540 3 года назад
He's at a point of tightening things up and leaving. Plus there's only him and James there, so I'm pretty sure that lock off not being on at this point isn't really an issue is it 😂
@roydowling2542
@roydowling2542 3 года назад
@@gkbailey540 I know. But he went through the whole thing of showing us that he locked off to work safely. Then when it comes to doing the buzz bar the lock is gone. Kinda defeats the purpose of showing us locked off no?
@Cjrelectrical
@Cjrelectrical 3 года назад
Main switch was also off bud we were ready to energize. It also got in the way of me tightening up the main switch with my Allen key. I didn’t leave the board unattended at this point and the house was empty.
@roydowling2542
@roydowling2542 3 года назад
@@Cjrelectrical 👍
@K3ndallUK
@K3ndallUK 3 года назад
He did put the outgoing cables pigtailed into the isolator 🙈. Bit of a no no. Easy to snag/pull that way.
@DavidWood-rz4vh
@DavidWood-rz4vh 3 года назад
James has some funky socks on 😂
@ryanallen3704
@ryanallen3704 3 года назад
There is no real reason a board can't be mounted sideways, as a 3 phase board has the MCBs/RCBOs mounted sideways. The only concern would be the lid not being able to self close i suppose?..
@farmersteve129
@farmersteve129 3 года назад
Probably not in accordance with manufacturer instructions...... The certification was almost certainly done in horizontal orientation, plus the lid should be top hinged etc.
@ryanallen3704
@ryanallen3704 3 года назад
@@farmersteve129 I did mention the lid...
@janeweedon6335
@janeweedon6335 3 года назад
Looks like they must have been in a rush to get it done...
@ggbalze06
@ggbalze06 3 года назад
I havnt used those flexi tails yet, are they multicore like flex? If so do they need a ferrule?
@stupot_64
@stupot_64 3 года назад
They have 19 strands rather than the 7 strands that standard tails have. You do not have ferrules on the end (just like on standard tails).
@ggbalze06
@ggbalze06 3 года назад
@@stupot_64 thank you
@APHEXHEAD
@APHEXHEAD 3 года назад
I've used them on many occasions and haven't used ferrules. They don't compress like Tri rated because the strands aren't as fine. They just have more slightly thinner strands than standard tails.
@asamitchell7948
@asamitchell7948 3 года назад
Cut down the length of 32mm conduit and clip it over the gas pipe sleeves the pipe if its close to cable or consumer units was taught it off a gas lad who uses waste pipe with duct tape but I use 32mm conduit or small waste pipe
@andyjones7836
@andyjones7836 3 года назад
That's a great idea 👍
@HeathenGeek
@HeathenGeek 3 года назад
17:30 get the laser level out 😁
@thedon7536
@thedon7536 3 года назад
If you use lock off ? Haw come you always put them upside down or fluff around like a rookie ? Another great video, keep them coming
@timg6850
@timg6850 3 года назад
From what I seen in previous videos, rarely do the Tails from the meter have an isolator. That means he usually has to call "Pablo" in to pull the Main fuse so he can do a board change.
@imtrue2132
@imtrue2132 3 года назад
A shame that he did make all the numbers up. Perhaps he was in an rush ! 😁 😂🤫
@markpunt9638
@markpunt9638 3 года назад
That was lovely for someone to do your website for you - there are some very kind people out there.
@883daim
@883daim 3 года назад
Your so perfect ,never done a bodge in your life, well done you.
@grumpygit447
@grumpygit447 3 года назад
That rest report just shows what a joke test certificates can be Just because some people are registered does not mean they test properly It should not be all about registration but about doing the testing properly
@daxw2460
@daxw2460 3 года назад
Please we really appreciate your time. We Require type of insulation fire mastic please. And torque screwdriver?
@Cjrelectrical
@Cjrelectrical 3 года назад
Everflex Draper and wiha
@greenyamo1321
@greenyamo1321 3 года назад
Rush Electrics by name, Rush Electrics by nature 😂😂😂
@HappilyHomicidalHooligan
@HappilyHomicidalHooligan 3 года назад
If you really want to play with/distract the cats, go to the Dollar Store and get a LASER Pointer... I have yet to find a cat that won't chase the red/green (depends on LASER Pointer) dot around...
@rowanNClangley
@rowanNClangley 3 года назад
Sleeving is one of the best cat toys invented
@johnoreilly7052
@johnoreilly7052 3 года назад
Can you please send me the consumer unit not the new one the old one please Chris and thanks for sharing your video with me and I would love to see a lot more of your videos
@bernardcharlesworth9860
@bernardcharlesworth9860 2 года назад
Always use an electric screwdriver quicker and less rsi even though manufacturers state no power tools.
@kevinpickett7249
@kevinpickett7249 3 года назад
The best one I've had is an approved Niceic spark completed a full test then failed it saying crossed polarity ( main switch incorrectly connected ( bus bar is neutral and neutral block live ) 😜 when all it was is the main switch had been changed and just because live was in the N TERMINAL AND THE neutral in the L TERMINAL BUT BEING A DP SWITCH IT DID NOT MATTER IT STILL FED THE BOARD CORRECTLY 😷 so he condemn it and said dangerous installation yet apparently his tester still carried out tests on what he said was crossed polarity installation ? Money making exercise and a blatant lie ( all in print for the world to see ) it worries me is 1 he has not got a clue or 2 he just ripping people off.
@jonathanlove5545
@jonathanlove5545 3 года назад
150mm to consumer units and unswitched sockets
@ChristmasCrustacean1
@ChristmasCrustacean1 3 года назад
electricians joking about the copper they pull out being their apprentices wages has been a classic joke that will never die and will always be funny, may James do it to his apprentices.
@jongmassey
@jongmassey 3 года назад
I'm guessing that EICR was a bit of a rush job?
@spookyboo3164
@spookyboo3164 3 года назад
Trouble is they don't pay them the money they used to get for testing per ccu
@Malandrin
@Malandrin 3 года назад
that "electrician" had probably a fake license 😂😂
@dc-sd3gd
@dc-sd3gd 3 года назад
If he didnt nul leads he couldve had higher readings
@thdreefie
@thdreefie 2 года назад
I do like watching your videos but can scarcely understand you because of your accent. I’m sure you would have the same problem trying to understand me, since I am from the southern US. The thing you refer to as a “Consumer Unit”. Is what we call a sub panel or load center here. I am a bit confused as to what test you are running on the existing wiring, prior to the replacement of the consumer unit. Oh well…I’ll just keep watching and try to figure it all out.
@johncoles
@johncoles 3 года назад
I guess that’s what happens when you’re in a Rush...
@ramvekaria4079
@ramvekaria4079 3 года назад
One of the four people who know who truly messed up!
@jameswoods7276
@jameswoods7276 3 года назад
Every job is better when you have some cats to play with. Just remember the cat treats next time. 😁
@petertallowin6406
@petertallowin6406 3 года назад
With the price of copper these days mate I would take that bus bar and run to the scrap man..... haha Seems like that EICR is worm food.
@MartynSmith
@MartynSmith 3 года назад
Confused - Why would you say Satisfactory overall if parts are unsatisfactory, - Aren't you doing yourself out of the probable business of fixing stuff. The only reason I can think of is you can make more money on EICR's than the work ?
@HappilyHomicidalHooligan
@HappilyHomicidalHooligan 3 года назад
It's crap like this that's the reason Electricians in Canada are NOT allowed to Self-Inspect their work, that's what the City/County Government Inspectors are for...to (try and*) prevent stuff like this... * I say try because the Inspectors are still Human and not all of them are good at their jobs and miss stuff they really shouldn't...
@bunnylove273
@bunnylove273 3 года назад
Hi bud l am no spark but l do like your vids and on this occasion you are the professional and the other was a cow person 😉
@jimmydemetriou7847
@jimmydemetriou7847 3 года назад
What can customers do if those working in the industry are not willing to report bad practice when they come across it? The whole industry needs to be overhauled. There are good electricians, and then there are ones that should lose their certification.
@AndyK.1
@AndyK.1 3 года назад
Cat sitter too
@christopherhulse8385
@christopherhulse8385 3 года назад
Lovely cats!
@vincentguidi8997
@vincentguidi8997 3 года назад
Nice video. New side channel of cat videos ??? 🙂
@TheColinputer
@TheColinputer 3 года назад
I say the previous guy spent the entire time playing with the cats and so had to make it all up
@RichardArblaster
@RichardArblaster 3 года назад
Nice job 😎
@HappilyHomicidalHooligan
@HappilyHomicidalHooligan 3 года назад
If it's allowed by UK Law, I'd recommend that your Client Sue the Moron that did the "Testing" for Fraud and get his money back... I'd also suggest you report him to the Licensing Agency for Fraud and try getting him investigated with an eye towards a License Revocation... With what this guy didn't look at/faked, what did he miss that could either fry the homeowner or burn down the house?
@ramvekaria4079
@ramvekaria4079 3 года назад
Chris, you have to work on your pixelation!!!
@BobSmith-ui4qu
@BobSmith-ui4qu 2 года назад
I wish you could number , in order, or date your videos. I am in Canada and have been watching for a while now. Big thumbs up. March 2022.
@emsservices6090
@emsservices6090 3 года назад
The chap who did the eicr should be ashamed. I don't think I would RUSH to use him for his ELECTRICS, especially from HIGH WYCOMBE, BUCKS.
@8inary
@8inary 3 года назад
lol as soon as I saw those buzz bars, I thought of Nick, then you said batman, I was like haha and yes, he will expect the shipment soon. When we have ww3 and money becomes useless, good old Nick will be living the life of luxury with his copper bars.
@effervescence5664
@effervescence5664 3 года назад
Chris it's 150mm from a Gas meter and it's non-conductive/combustible material. Also it's not suprising to see a satisfactory report with boiler installation wiring like that as it's deemed "part of the appliance". C3 on the bonding sure as it's improvement recommended, but those C2's... WTH. Edit: bone idle on the bonding the bloke was aye.
@Graham_Langley
@Graham_Langley 3 года назад
Looked into this when I changed the CU here. Lots of refs. to a non-conductive and non-combustable barrier if less than 150mm but not one example given of a suitable material or a picture of one in situ. Asked the commissioning sparks and he said he'd never fitted one so I didn't bother.
@effervescence5664
@effervescence5664 3 года назад
@@Graham_Langley Cement board is normally my go to as it's what my local college and my GasSafe assessor/ NICEIC assessor both agreed on. I just use metal L brackets to bolt it to the wall.
@Graham_Langley
@Graham_Langley 3 года назад
@@effervescence5664 That's something I'd thought of but didn't have any to hand. The use of metal brackets raises an interesting point how to you fit it? Metal brackets are conductive and a block of wood is combustible, plus any screws will be metal and will go through the barrier if it's something like cement board. Also does this reg. take into account metal-cased CUs?
@effervescence5664
@effervescence5664 3 года назад
@@Graham_Langley Normally use 10mm board and just make a slot in the bottom and top for the board to slide over the bracket. Then drill them into the wall with screw fixings on the gas meter side away from potential conductors. You can use plasterboard too but I found it a little flimsy. Edit: No the reg does not take into account metal CU's - it's written as any CU due to being a Gas regulation copied into the Electrical regs and not the other way around.
@Graham_Langley
@Graham_Langley 3 года назад
@@effervescence5664 Thank you. Looks like I''ll have to have a look at it again if only to score brownie points should the installation ever have to be checked in the future. [Edit] FWIW I was going to use the 4mm fibre cement board used for roof undercloaking and soffits.
Далее